Thickness effects of thin La0.7Sr0.3MnO3 (LSMO) films on (LaAlOa)0.3(Sr2AlTaO6)0.7 substrates were examined by a slow positron beam technique. Doppler-broadening line shape parameter S was measured as a function...Thickness effects of thin La0.7Sr0.3MnO3 (LSMO) films on (LaAlOa)0.3(Sr2AlTaO6)0.7 substrates were examined by a slow positron beam technique. Doppler-broadening line shape parameter S was measured as a function of thickness and differnt annealing conditions. Results reveal there could be more than one mechanism to induce vacancy-like defects. It was found that strain-induced defects mainly influence the S value of the in situ oxygenambience annealing LSMO thin films and the strain could vanish still faster along with the increase of thickness, and the oxygen-deficient induced defects mainly affect the S value of post-annealing LSMO films.展开更多
Simulate anneal arithmetic has been used to settle the problem of time bunching on a pulsed slow-positron beam device. This paper has searched for the parameters of the device in a large scope and achieved the time re...Simulate anneal arithmetic has been used to settle the problem of time bunching on a pulsed slow-positron beam device. This paper has searched for the parameters of the device in a large scope and achieved the time resolution within 150ps at the target with accelerating voltage in a range of 0.5-30kV.展开更多
Slow positron beam was applied to study the depth profile structure of the virgin and the aged high-temperature vulcanized silicone rubber(HTV). Scanning electron microscope(SEM) images show that the surface of virgin...Slow positron beam was applied to study the depth profile structure of the virgin and the aged high-temperature vulcanized silicone rubber(HTV). Scanning electron microscope(SEM) images show that the surface of virgin sample is smooth, while the outdoor aged samples are all rough. According to the S(E) curves obtained by slow positron beam, in a depth of more than 1 μm, the S parameter of the sample aged at low-potential side keeps the same value with the virgin one;while the S values of the highpotential side aged sample remain rather low in a depth of about 5 μm. Thermo gravimetric analysis(TGA) results show that the sample in high potential side contains more inorganic constituents than that of other samples. The results are attributed to the strong electric field induced corona aging at high potential side of the composite insulator.展开更多
The Beijing intense slow positron beam facility is based on the 1.3 GeV linac of Beijing ElectronPositron Collider (BEPC) aiming to produce mono-energetic intense slow positron beam for material science investigatio...The Beijing intense slow positron beam facility is based on the 1.3 GeV linac of Beijing ElectronPositron Collider (BEPC) aiming to produce mono-energetic intense slow positron beam for material science investigation. The plugged-in 22Na based slow positron beam section has been newly constructed to supply continuous beam time for the debugging of positron annihilation measurement stations and improve the Beijing intense slow positron beam time using efficiency. Performance testing result of the plugged-in 22Na based slow positron beam facility are reviewed in this paper, with the measurement of the beam transport efficiency, the view of beam spot, the adjustment of beam position, the measurement of beam intensity and energy spread etc. included.展开更多
A new slow pulsed positron beam, including a positron source, a moderator, a chopper, a prebuncher, a main-buneher and a sample chamber, etc, has been installed and tested. It is necessary to simulate the acceleration...A new slow pulsed positron beam, including a positron source, a moderator, a chopper, a prebuncher, a main-buneher and a sample chamber, etc, has been installed and tested. It is necessary to simulate the acceleration, transportation and space focusing of positrons to meet the needs of beam debugging and further positron annihilation experiments. The result from SIMION simulations shows that the radius of the focused positron beam is less than 5 mm, which is further confirmed in our practical debugging process.展开更多
For the proper interpretation of the experimental data produced in slow positron beam technique, the positron implantation properties are studied carefully using the latest Geant4 code. The simulated backscattering co...For the proper interpretation of the experimental data produced in slow positron beam technique, the positron implantation properties are studied carefully using the latest Geant4 code. The simulated backscattering coefficients, the implantation profiles, and the median implantation depths for mono-energetic positrons with energy range from 1 keV to 50 keV normally incident on different crystals are reported. Compared with the previous experimental results, our simulation backscattering coefficients are in reasonable agreement, and we think that the accuracy may be related to the structures of the host materials in the Geant4 code. Based on the reasonable simulated backscattering coefficients, the adjustable parameters of the implantation profiles which are dependent on materials and implantation energies are obtained. The most important point is that we calculate the positron backscattering coefficients and median implantation depths in amorphous polymers for the first time and our simulations are in fairly good agreement with the previous experimental results.展开更多
Two types of porous metal moderators (i.e. porous nickel layer and multi-wire tungsten layer) are proposed and tested on a slow positron beam line. A moderation efficiency of about 2×10-4 has been achieved, which...Two types of porous metal moderators (i.e. porous nickel layer and multi-wire tungsten layer) are proposed and tested on a slow positron beam line. A moderation efficiency of about 2×10-4 has been achieved, which is higher than that for W vane geometry moderator by a factor of 4.展开更多
In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to no...In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to normal tissues along the beam path is thus greatly reduced.In-beam PET provides a way to monitor dose distribution inside human body since several kinds of positron-emitting nuclei are produced through the interaction between 12C beam and body matters.In this work,we study the quantitative relationship between the spatial location of the Bragg peak and the spatial distribution of positrons produced by positron-emitting nuclei.Monte Carlo package GATE is used to simulate the interactions between the incident 12C beam of different energies(337.5,270.0 and 195.0 MeV/u) and various target matters(water,muscle and spine bone).Several data post-processing operations are performed on the simulated positron-emitting nuclei distribution data to mimic the impacts of positron generation and finite spatial resolution of a typical PET imaging system.Simulation results are compared to published experimental data for verification.In all the simulation cases,we find that 10C and 11C are two dominant positron-emitting nuclei,and there exists a significant correlation between the spatial distributions of deposited energy and positrons.Therefore,we conclude that it is possible to determine the location of Bragg peak with 1 mm accuracy using current PET imaging systems by detecting the falling edge of the positron distribution map in depth direction.展开更多
High chromium (Cr: 16% - 19%) iron alloy with 5% and 10% manganese (Mn) fabricated in metal and sand moulds by induction melting technique were investigated for defects microstructure both in the as-cast and heat trea...High chromium (Cr: 16% - 19%) iron alloy with 5% and 10% manganese (Mn) fabricated in metal and sand moulds by induction melting technique were investigated for defects microstructure both in the as-cast and heat treated conditions. Non-destructive techniques namely Positron Lifetime Spectroscopy and slow positron Doppler Broadening studies were employed to characterize the defects in the bulk as well as surface of the alloy and their influence of metallurgical parameters. The Positron Lifetime Spectroscopy data reveals that the defect concentration is higher for sand mould alloy samples compared to metal mould ones. The reasons for fewer defects in metal mould are attributed to faster heat transfer in the metal mould. Further, heat treatment yielded spherodization of carbides in the matrix resulting in reduced defects concentration. The S-parameter profiles from Doppler Broadening studies suggest defect concentration at the surface is less in 5% Manganese and near absence of any modification of defect structure following heat treatment in 10% Manganese sample closer to surface.展开更多
In a previous paper [1] we established the possibility of the advantage of using the bombardment of electron-positron beams to produce commercial electrical energy. We consider the design of such a prototype reactor u...In a previous paper [1] we established the possibility of the advantage of using the bombardment of electron-positron beams to produce commercial electrical energy. We consider the design of such a prototype reactor using 100 KJ laser beams to produce electron-positron beams that are sent to the reactor to release the 100 KJ of energy in the form of Xrays, which creates the high temperature and pressure needed to ignite the deuterium-tritium pellets for the fusion reaction.展开更多
文摘Thickness effects of thin La0.7Sr0.3MnO3 (LSMO) films on (LaAlOa)0.3(Sr2AlTaO6)0.7 substrates were examined by a slow positron beam technique. Doppler-broadening line shape parameter S was measured as a function of thickness and differnt annealing conditions. Results reveal there could be more than one mechanism to induce vacancy-like defects. It was found that strain-induced defects mainly influence the S value of the in situ oxygenambience annealing LSMO thin films and the strain could vanish still faster along with the increase of thickness, and the oxygen-deficient induced defects mainly affect the S value of post-annealing LSMO films.
基金Project supported by the National Natural Science Foundation of China (Grant Nos 10675114 and 10675115)
文摘Simulate anneal arithmetic has been used to settle the problem of time bunching on a pulsed slow-positron beam device. This paper has searched for the parameters of the device in a large scope and achieved the time resolution within 150ps at the target with accelerating voltage in a range of 0.5-30kV.
基金Funded by the National Natural Science Foundation of China(No.21174108)the Science and Technology Project of China Southern Power Grid Co,Ltd(No.GDKJQQ20161197)
文摘Slow positron beam was applied to study the depth profile structure of the virgin and the aged high-temperature vulcanized silicone rubber(HTV). Scanning electron microscope(SEM) images show that the surface of virgin sample is smooth, while the outdoor aged samples are all rough. According to the S(E) curves obtained by slow positron beam, in a depth of more than 1 μm, the S parameter of the sample aged at low-potential side keeps the same value with the virgin one;while the S values of the highpotential side aged sample remain rather low in a depth of about 5 μm. Thermo gravimetric analysis(TGA) results show that the sample in high potential side contains more inorganic constituents than that of other samples. The results are attributed to the strong electric field induced corona aging at high potential side of the composite insulator.
基金Supported by NSFC(10475096)Special Fund for Equipment of CAS(U-37)
文摘The Beijing intense slow positron beam facility is based on the 1.3 GeV linac of Beijing ElectronPositron Collider (BEPC) aiming to produce mono-energetic intense slow positron beam for material science investigation. The plugged-in 22Na based slow positron beam section has been newly constructed to supply continuous beam time for the debugging of positron annihilation measurement stations and improve the Beijing intense slow positron beam time using efficiency. Performance testing result of the plugged-in 22Na based slow positron beam facility are reviewed in this paper, with the measurement of the beam transport efficiency, the view of beam spot, the adjustment of beam position, the measurement of beam intensity and energy spread etc. included.
基金Supported by Major Program of National Natural Science Foundation of China (10835006)National Natural Science Foundation of China (10675114)
文摘A new slow pulsed positron beam, including a positron source, a moderator, a chopper, a prebuncher, a main-buneher and a sample chamber, etc, has been installed and tested. It is necessary to simulate the acceleration, transportation and space focusing of positrons to meet the needs of beam debugging and further positron annihilation experiments. The result from SIMION simulations shows that the radius of the focused positron beam is less than 5 mm, which is further confirmed in our practical debugging process.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11175171 and 11105139)
文摘For the proper interpretation of the experimental data produced in slow positron beam technique, the positron implantation properties are studied carefully using the latest Geant4 code. The simulated backscattering coefficients, the implantation profiles, and the median implantation depths for mono-energetic positrons with energy range from 1 keV to 50 keV normally incident on different crystals are reported. Compared with the previous experimental results, our simulation backscattering coefficients are in reasonable agreement, and we think that the accuracy may be related to the structures of the host materials in the Geant4 code. Based on the reasonable simulated backscattering coefficients, the adjustable parameters of the implantation profiles which are dependent on materials and implantation energies are obtained. The most important point is that we calculate the positron backscattering coefficients and median implantation depths in amorphous polymers for the first time and our simulations are in fairly good agreement with the previous experimental results.
基金Supported by the National Natural Science Foundation of China(No.19927001 and No.10275076)
文摘Two types of porous metal moderators (i.e. porous nickel layer and multi-wire tungsten layer) are proposed and tested on a slow positron beam line. A moderation efficiency of about 2×10-4 has been achieved, which is higher than that for W vane geometry moderator by a factor of 4.
基金supported in part by Specialized Research Fund for the Doctoral Program of Higher Education (SRFDP200800031071)National Natural Science Foundation of China (No. 10975086)the National High Technology Research and Development Program ("863" Program) of China (No. 2006AA020802)
文摘In comparison with conventional radiotherapy techniques,12C beam therapy has its significant advantage in cancer treatment because the radiation dose are mostly concentrated near the Bragg peak region and damage to normal tissues along the beam path is thus greatly reduced.In-beam PET provides a way to monitor dose distribution inside human body since several kinds of positron-emitting nuclei are produced through the interaction between 12C beam and body matters.In this work,we study the quantitative relationship between the spatial location of the Bragg peak and the spatial distribution of positrons produced by positron-emitting nuclei.Monte Carlo package GATE is used to simulate the interactions between the incident 12C beam of different energies(337.5,270.0 and 195.0 MeV/u) and various target matters(water,muscle and spine bone).Several data post-processing operations are performed on the simulated positron-emitting nuclei distribution data to mimic the impacts of positron generation and finite spatial resolution of a typical PET imaging system.Simulation results are compared to published experimental data for verification.In all the simulation cases,we find that 10C and 11C are two dominant positron-emitting nuclei,and there exists a significant correlation between the spatial distributions of deposited energy and positrons.Therefore,we conclude that it is possible to determine the location of Bragg peak with 1 mm accuracy using current PET imaging systems by detecting the falling edge of the positron distribution map in depth direction.
文摘High chromium (Cr: 16% - 19%) iron alloy with 5% and 10% manganese (Mn) fabricated in metal and sand moulds by induction melting technique were investigated for defects microstructure both in the as-cast and heat treated conditions. Non-destructive techniques namely Positron Lifetime Spectroscopy and slow positron Doppler Broadening studies were employed to characterize the defects in the bulk as well as surface of the alloy and their influence of metallurgical parameters. The Positron Lifetime Spectroscopy data reveals that the defect concentration is higher for sand mould alloy samples compared to metal mould ones. The reasons for fewer defects in metal mould are attributed to faster heat transfer in the metal mould. Further, heat treatment yielded spherodization of carbides in the matrix resulting in reduced defects concentration. The S-parameter profiles from Doppler Broadening studies suggest defect concentration at the surface is less in 5% Manganese and near absence of any modification of defect structure following heat treatment in 10% Manganese sample closer to surface.
文摘In a previous paper [1] we established the possibility of the advantage of using the bombardment of electron-positron beams to produce commercial electrical energy. We consider the design of such a prototype reactor using 100 KJ laser beams to produce electron-positron beams that are sent to the reactor to release the 100 KJ of energy in the form of Xrays, which creates the high temperature and pressure needed to ignite the deuterium-tritium pellets for the fusion reaction.