期刊文献+
共找到79篇文章
< 1 2 4 >
每页显示 20 50 100
Two-dimensional particle-in-cell modeling of blow-off impulse by X-ray irradiation
1
作者 Ruibo Li Jin-Long Jiao +3 位作者 Hui Luo Dezhi Zhang Dengwang Wang Kai Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期53-69,共17页
Space objects such as spacecraft or missiles may be exposed to intense X-rays in outer space,leading to severe damage.The reinforcement of these objects to reduce the damage caused by X-ray irradiation is a significan... Space objects such as spacecraft or missiles may be exposed to intense X-rays in outer space,leading to severe damage.The reinforcement of these objects to reduce the damage caused by X-ray irradiation is a significant concern.The blow-off impulse(BOI)is a crucial physical quantity for investigating material damage induced by X-ray irradiation.However,the accurate calculation of BOI is challenging,particularly for large deformations of materials with complex configurations.In this study,we develop a novel two-dimensional particle-in-cell code,Xablation2D,to calculate BOIs under far-field X-ray irradiation.This significantly reduces the dependence of the numerical simulation on the grid shape.The reliability of this code is verified by simulation results from open-source codes,and the calculated BOIs are consistent with the experimental and analytical results. 展开更多
关键词 x-ray irradiation Energy deposition Blow-off impulse Particle in cells
下载PDF
Effects of Corticosterone, cAMP, cGMP, Ca^(2+), and Protein Kinase C on Apoptosis of Mouse Thymocytes Induced by X-ray Irradiation 被引量:4
2
作者 SHOU-LIANG GONG LI-HUA DONG +5 位作者 GUANG-WEI LIU PING-SHENG GONG WEN-TIAN LU HONG-GUANG ZHAO XIAO-JING JIA YONG ZHAO 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2008年第2期167-172,共6页
Objective To observe the effects of signal factors of corticosterone (CS), cAMP, cGMP, Ca^2+ and protein kinase C (PKC) on lymphocyte apoptosis in mouse thymus induced by X-rays of 4 Gy in vitro. Methods The DNA ... Objective To observe the effects of signal factors of corticosterone (CS), cAMP, cGMP, Ca^2+ and protein kinase C (PKC) on lymphocyte apoptosis in mouse thymus induced by X-rays of 4 Gy in vitro. Methods The DNA lyric rate for thymocytes was measured by fluomspectrophotometry. Results The DNA lyric rate for thymocytes 4-8 hours after irradiation with 2-8 Gy was significantly higher than that in the control (P〈0.01). As compared with the control, the DNA lyric rate for thymocytes treated with 0.01 μnol/L CS (P〈0.01), 50 ng/mL cAMP (P〈0.01), 0.05-0.4 μg/mL ionomycin (Iono, P〈0.05 or P〈0.01) or 0.05-0.4 ng/mL phorbol myristate acetate (PMA, P〈0.05 or P〈0.01), respectively, was significantly increased, while the rate for thymocytes treated with 50 ng/mL cGMP was not significantly increased. The DNA lyric rate for thymocytes treated with 0.01 μmol/L CS (P〈0.01), 50 ng/mL cAMP (P〈0.01), 0.2 and 0.4 μg/mL Iono (P〈0.05), and 0.2 and 0.4 ng/mL PMA (P〈0.05) plus 4-Gy irradiation, respectively, was significantly higher than that treated with single 4-Gy irradiation, while the rate for thymocytes treated with 50 ng/mL cGMP plus 4-Gy irradiation was not increased. When both 0.4 I.tg/mL Iono and 0.4 ng/mL PMA acted on the thymocytes, the DNA lyric rate for thymocytes was significantly higher than that in the control (P〈0.01), the DNA lytic rate for thymocytes treated with both 0.4 μg/mL Iono and 0.4 ng/mL PMA plus 4-Gy irradiation was significantly higher than that treated with single 4-Gy irradiation (P〈0.05), but was Iono plus 4-Gy irradiation or 0.4 ng/mL PMA plus 4-Gy irradiation. can promote thymocyte apoptosis induced by larger dose X-rays. not significantly higher than that treated with 0.4 μg/mL Conclusion CS, cAMP, Ca^2+, and PKC signal factors can promote thymocyte apoptosis induced by larger dose X-rays. 展开更多
关键词 CORTICOSTERONE CAMP CGMP Ca^2+ PKC x-ray irradiation LYMPHOCYTE APOPTOSIS
下载PDF
Effect of X-ray irradiation on threshold voltage of AlGaN/GaN HEMTs with p-GaN and MIS Gates 被引量:3
3
作者 Yongle Qi Denggui Wang +4 位作者 Jianjun Zhou Kai Zhang Yuechan Kong Suzhen Wu Tangsheng Chen 《Nanotechnology and Precision Engineering》 CAS CSCD 2020年第4期241-243,共3页
Commercially available AlGaN/GaN high-electron-mobility transistors(HEMTs)are beginning to enter the public scene froma range of suppliers.Based on previous studies,commercial GaN-based electronics are expected to be ... Commercially available AlGaN/GaN high-electron-mobility transistors(HEMTs)are beginning to enter the public scene froma range of suppliers.Based on previous studies,commercial GaN-based electronics are expected to be tolerant to different types of irradiation in space.To test this assumption,we compared the characteristic electrical curves obtained at different X-ray irradiation doses for GaN HEMT devices manufactured by Infineon and Transphorm.The p-GaN-based device was found to be more robust with a stable threshold voltage,whereas the threshold voltage of the device with ametal-insulator-semiconductor gatewas found to shift first in the negative and then the positive direction.This dynamic phenomenon is caused by the releasing and trapping effects of radiation-induced charges in the dielectric layer and at the interface of irradiated devices.As such,the p-GaNgate-based GaN HEMT provides a promising solution for use as an electric source in space. 展开更多
关键词 p-GaN gate GaN HEMTs x-ray irradiation Threshold voltage
下载PDF
Investigation on the hydrodynamics of slab x-ray laser plasma by nonuiform line focused laser irradiation
4
作者 程涛 李英骏 +1 位作者 孟立民 李希波 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第2期260-265,共6页
Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of ... Based on the two-dimensional model, this paper compares the hydrodynamics of slab x-ray laser plasma produced by different nonuniform line focused irradiations. It finds that the average intensity and the duration of laser pulse and the overall shape of the intensity distribution in the focal line have different influences on the plasma. Calculations show that the evolution of temperature variation is more sensitive to the pulse duration and the electron density variation is more sensitive to the pulse intensity. Pulses with duration of 200 ps to 500 ps and with intensity of 0.2 TW/cm2 to 1.0 TW/cm2 are proved acceptable in slab x-ray lasers. 展开更多
关键词 PLASMA slab x-ray laser nonuniform line focused laser irradiation HYDRODYNAMICS
下载PDF
POSTOPERATIVE IRRADIATION OF KELOIDS: ANALYSIS OF 125 PATIENTS
5
作者 孙洁 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1993年第1期59-62,共4页
Between October 1985 and June 1992 Postoperative kelolds of 125 Patients were treated with superficial X-ray (100-140 Kv) and electron beam (6 and 9 MeV ), in an attempt to prevent their recurrence, 100 patients with ... Between October 1985 and June 1992 Postoperative kelolds of 125 Patients were treated with superficial X-ray (100-140 Kv) and electron beam (6 and 9 MeV ), in an attempt to prevent their recurrence, 100 patients with 129 sites received a dose of 1200-4000 cGy at 200-300 cGy per fraction within one to four weeks and at intervals of one to three weeks between excision and irradiation. Rate of success In the prevention of kelold was only 28. 6% (37/ 129). However, 25 patients with 25 sites received a total dose of 1500 cGy at 500 cGy per fraction starting within one week after excision and at Intervals of 96 hours. The success rate was 84% (21/25). 展开更多
关键词 Superficial x-ray irradiation Keloida.
下载PDF
3-44 Effects of X-ray and Carbon-ion Irradiation on Hematopoietic Cell Counts in the Mice Model
6
作者 Liu Fang Wang Zhuanzi +2 位作者 Li Wenjian Wei Wei Dang Bingrong 《IMP & HIRFL Annual Report》 2015年第1期143-143,共1页
The hematological effects of space radiation contribute to the compromised immune defense in astronauts observed in the space environment as well as upon landing[1]. The complications associated with the hematopoietic... The hematological effects of space radiation contribute to the compromised immune defense in astronauts observed in the space environment as well as upon landing[1]. The complications associated with the hematopoietic syndrome include infection and internal hemorrhage. The decrease in peripheral blood cell counts after radiation serves not only as a marker for the severity of the exposure, but also as a marker for treatment and prognosis[2]. In the present research, we investigated the effects of whole-body heavy-ion (80 MeV/u carbon-ion) radiation and conventional X-ray (6 MV) radiation on peripheral blood cell counts in mice model. Time effects were determined to compare the effects of the different types of radiation. 展开更多
关键词 x-ray Carbon-ion irradiation
下载PDF
An Approach for Using of Poly Glycolic Acid (PGA) in Reference Standard Dosimetry: PGA/ESR Dosimetry System Response Curve and Post Irradiation Stability
7
作者 Arbi Mejri Haikel Jelassi +2 位作者 Khaled Farah Ahmad Hichem Hamzaoui Hichem Eleuch 《World Journal of Nuclear Science and Technology》 2012年第3期73-79,共7页
Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurem... Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications. 展开更多
关键词 DOSIMETRY Solid State Dosimeter (SSD) POLY Glycolic Acid (PGA) Electron Spin Resonance (ESR) Reference Standard Dosimetery post-irradiation Thermal Treatments Fading Behaviour
下载PDF
αB-crystallin malondialdehyde,superoxide dismutase, and lutathione peroxidase changes in X-ray irradiated rat lens 被引量:1
8
作者 Guo-Xu Xu, Guo-Tong Xu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第4期365-370,共6页
AIM: To evaluate αB-crystallin malondialdehyde (MDA), superoxide dismutase (SOD) and glutathione peroxidase (GPx) changes in X-ray irradiated rat lens. METHODS: Eight-week-old Sprague-Dawley male rats received X-ray ... AIM: To evaluate αB-crystallin malondialdehyde (MDA), superoxide dismutase (SOD) and glutathione peroxidase (GPx) changes in X-ray irradiated rat lens. METHODS: Eight-week-old Sprague-Dawley male rats received X-ray irradiation to the head with rest of the body protected. The exposure dose ranged from 2 to 25 Grays (Gy). The cataract status were examined by slit lamp and rated with 'four-grade systems' post-irradiation. The lens MDA level, and the activities of SOD and GPx were measured in a short-term experiment post-irradiation, and αB-crystallin protein levels were quantified. RESULTS: The lenses of normal control and the X-ray irradiated groups with the dose up to 10 Gy remained transparent throughout the experiment. The lens first appeared tiny scatters, and even lamellar opacities in the posterior capsule 45 days post-irradiation with the dose of 15 Gy, and progressed slowly to the advance stage of cataract; while, for the higher dose (25 Gy), the opacity of lens appeared much earlier, and progressed more rapidly to mature stage of cataract within 1 month. At the end of the observation (90 days post-irradiation), almost all lenses became complete opacity with the higher dose (25 Gy). The degree of lens opacity was rated accordingly. The lens MDA level was increased, and SOD and GPx activities were decreased with a dose-dependent manner post-irradiation. The αB-crystallin protein level was decreased dose-dependently at the end point of observation. CONCLUSION: Oxidative events and αB-crystallin may play important roles in the pathogenesis of cataract in X-ray irradiated rat lens. 展开更多
关键词 αB-crystallin malondialdehyde superoxide dismutase glutathione peroxidase x-ray irradiation CATARACT
下载PDF
Evaluation of the Effects of Irradiation of Peanut Grain by a Gamma-Ray Beam on Culture
9
作者 G. Mbaye M. Soumboundou +8 位作者 L. A. D. Diouf B. Ndong A. R. Djiboune P. M. Sy S. M. Dieng M. Diouf N. N. Diouf A. Barry M. Diarra 《Open Journal of Biophysics》 2017年第3期94-100,共7页
The problems of agriculture in Senegal result in a low yield per hectare and poor seed quality contributing strongly to the decline in productivity. Mutagenesis by X- or Y-ray irradiation makes it possible to obtain g... The problems of agriculture in Senegal result in a low yield per hectare and poor seed quality contributing strongly to the decline in productivity. Mutagenesis by X- or Y-ray irradiation makes it possible to obtain genetic mutants necessary to improve production. It is in this context that we undertook this study to evaluate the effects induced on the cultivation of peanut seeds irradiated by X-rays at low doses applied in radiotherapy. X-ray irradiation of four (2, 3, 4, 5) lots of peanuts are performed with respectively 0.5, 1.5, 2 and 4 Gray using the cobalt 60 therapy device (Alcyon II). The seeding of the seeds and then the following-up of the crops during 35 days allowed us to study the parameters of germination, growth and yield. The results obtained after monitoring revealed that the irradiation did not have any significant impact on germination and would appear to temporarily inhibit the growth rate compared to the control batch. However, the decrease in weight of the harvested seeds can be explained by the absence of fertilizer during the cultivation. 展开更多
关键词 Peanuts CULTURE irradiation x-rays
下载PDF
High-Efficiency Synthesis and Properties of Latent Pigment Red 272DPP-BOC by Microwave Irradiation
10
作者 Tomoji Ohishi Yu Kimura +2 位作者 Kiyohiko Nakajima Masayuki Watanabe Noboru Aoyagi 《Materials Sciences and Applications》 2020年第3期195-203,共9页
A high-efficiency synthesis method for a latent pigment of red pigment diketo-pyrrolo-pyrrole (Pig. Red 272:272DPP), which is important as a functional organic pigment, was investigated, and the investigation results ... A high-efficiency synthesis method for a latent pigment of red pigment diketo-pyrrolo-pyrrole (Pig. Red 272:272DPP), which is important as a functional organic pigment, was investigated, and the investigation results revealed that irradiation of microwaves (MWs) for several seconds to 272 DPP in NMP (N-methyl-2-pyrrolidone) solvent yielded DPP latent pigment (272DPP-BOC) at a high yield of 86.2%. Two kinds of latent-pigment crystals, namely, red and yellow, were obtained by recrystallization, and it was found that the fluorescence-emission properties of the two kinds differ significantly. Single-crystal X-ray structural analysis showed that the difference in the fluorescence-emission properties of the two types is derived from the difference in their crystal structures. 展开更多
关键词 LATENT PIGMENT Diketopyrrolopyrrol PIGMENT RED 272 High Efficiency SYNTHESIS Microwave irradiation SINGLE-CRYSTAL x-ray Analysis
下载PDF
Time-resolved K-shell x-ray spectra of nanosecond laser-produced titanium tracer in gold plasmas
11
作者 何贞岑 张继彦 +2 位作者 杨家敏 闫冰 胡智民 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第1期51-55,共5页
A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By co... A study of a nanosecond laser irradiation on the titanium-layer-buried gold planar target is presented. The timeresolved x-ray emission spectra of titanium tracer are measured by a streaked crystal spectrometer. By comparing the simulated spectra obtained by using the FLYCHK code with the measured titanium spectra, the temporal plasma states, i.e.,the electron temperatures and densities, are deduced. To evaluate the feasibility of using the method for the characterization of Au plasma states, the deduced plasma states from the measured titanium spectra are compared with the Multi-1D hydrodynamic simulations of laser-produced Au plasmas. By comparing the measured and simulated results, an overall agreement for the electron temperatures is found, whereas there are deviations in the electron densities. The experiment–theory discrepancy may suggest that the plasma state could not be well reproduced by the Multi-1D hydrodynamic simulation, in which the radial gradient is not taken into account. Further investigations on the spectral characterization and hydrodynamic simulations of the plasma states are needed. All the measured and FLYCHK simulated spectra are given in this paper as datasets. The datasets are openly available at http://www.doi.org/10.57760/sciencedb.j00113.00032. 展开更多
关键词 nanosecond laser irradiation time-resolved x-ray spectra characterization of plasma states Multi-1D hydrodynamic simulations
下载PDF
乏燃料棒M5锆合金包壳的透射电镜分析
12
作者 钱进 卞伟 +2 位作者 郭一帆 王鑫 梁政强 《原子能科学技术》 EI CSCD 北大核心 2024年第1期149-156,共8页
压水堆燃料元件的锆合金包壳,在服役期间会经受高中子注量辐照,其微观组织将发生很大变化,从而影响其宏观性能,因此锆合金包壳的中子辐照行为研究一直是核领域的研究重点。但由于材料经中子辐照后具有较强的放射性,相关的实验必须在热... 压水堆燃料元件的锆合金包壳,在服役期间会经受高中子注量辐照,其微观组织将发生很大变化,从而影响其宏观性能,因此锆合金包壳的中子辐照行为研究一直是核领域的研究重点。但由于材料经中子辐照后具有较强的放射性,相关的实验必须在热室内进行,因此针对辐照后燃料包壳微观组织的研究也一直是工作的难点。本文在中国原子能科学研究院热室设施上,通过透射电镜分析手段,研究了M5锆合金包壳材料中子辐照后的微观组织。样品来源于国内商业压水堆AFA3G型乏燃料棒,其燃耗分别为14 GW·d/tU和41 GW·d/tU。从燃料棒上截取长度约10 mm的包壳样品,在热室内完成去芯块与化学清洗,获得空包壳样品,然后通过机械制样方法,制备出?3 mm薄片状包壳基体样品,最后采用电解双喷减薄方法,制备出包壳透射电镜观察分析样品。另外,为对比锆包壳辐照后的组织变化,采用同样方法制备了相同材料的冷态观察分析样品。冷态样品与辐照样品的观察分析结果表明:冷态Zr合金包壳基体组织内部存在原生的第二相粒子,基体内部整体较为干净,纳米析出相稀少,未观察到明显的位错结构;辐照后,基体内原生的第二相粒子尺寸和分布与冷态样品差异不明显,但出现了明显的纳米析出相和高密度位错组织;随着燃耗的增加,纳米析出相尺寸有增加的现象;低燃耗与高燃耗样品位错组织具有相似性,表明在14 GW·d/tU燃耗下,锆合金包壳内由辐照产生的位错组织已基本趋于饱和状态;电子选取衍射结果表明,辐照后,基体内原生的第二相粒子虽存在一些非晶组织,但仍以bcc晶体结构为主,表明在41 GW·d/tU燃耗下,第二相粒子保持了一定的辐照稳定性;另外,第二相的EDS结果表明,随着燃耗的增加,Nb元素的含量有贫化趋势;分析认为,Zr合金经中子辐照,第二相粒子中的Nb原子扩展至Zr基体内,将促进Nb元素以纳米富Nb相形式在Zr基体中析出。 展开更多
关键词 辐照后检验 透射电镜 压水堆 锆合金 燃料棒 中子辐照 热室
下载PDF
300 MeV质子重离子加速器及电子器件单粒子效应试验研究
13
作者 沈志强 刘剑利 +3 位作者 陈启明 肖一平 刘超铭 王天琦 《现代应用物理》 2024年第4期130-136,共7页
300 MeV质子重离子加速器主要用于模拟空间环境中高能粒子辐照,探索高能粒子与材料、器件以及生命体的相互作用机理。该加速器主要由离子源、直线加速器、注入线、同步加速器、引出线和3个实验终端组成。自2022年11月验收以来,该加速器... 300 MeV质子重离子加速器主要用于模拟空间环境中高能粒子辐照,探索高能粒子与材料、器件以及生命体的相互作用机理。该加速器主要由离子源、直线加速器、注入线、同步加速器、引出线和3个实验终端组成。自2022年11月验收以来,该加速器已完成质子束、氦束、碳束、氪束、钽束、铋束、铀束等离子束的调试,相继开展了材料、电子器件、农作物种子、微生物、小鼠等样品的辐照试验,成为基础研究的实验平台。在基于该加速器的辐照试验平台中,开展了国产SiC功率MOSFET器件单粒子效应研究。300 MeV质子重离子加速器产生能量为1864.3 MeV的^(181)Ta^(31+)离子束,在经过钛窗和空气中传输后,达到SiC表面时LET值为80.7 MeV·cm^(2)·mg^(-1)。通过在SiC功率MOSFET器件漏极上施加不同偏置电压,对栅极和漏极泄漏电流检测分析,获取了在不同偏置条件下SiC MOSFET器件的漏电退化行为。 展开更多
关键词 质子重离子加速器 高能粒子辐照 SiC功率MOSFET器件 栅极潜损伤 泄漏电流永久退化 单粒子烧毁
下载PDF
Establishment of NaLuF_(4):15%Tb-based low dose X-PDT agent and its application on efficient antitumor therapy
14
作者 Yi Tian Zhiguang Fu +7 位作者 Xiaosheng Zhu Chunjing Zhan Jinwei Hu Li Fan Chaojun Song Qian Yang Yu Wang Mei Shi 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第3期599-610,共12页
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev... X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth. 展开更多
关键词 x-ray excited photodynamic therapy singlet oxygen low dose x-ray irradiation efficient antitumor therapy anti-tumor immunity
下载PDF
Enhanced removal of X-ray-induced carbon contamination using radio-frequency Ar/H_2 plasma
15
作者 Yi Wang Qi-Peng Lu +2 位作者 Yun-Guo Gao Xue-Peng Gong Yuan Song 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第2期61-69,共9页
Removal of X-ray-induced carbon contamination on beamline optics was studied using radio-frequency plasma with an argon/hydrogen(Ar/H_2) mixture. Experiments demonstrated that the carbon removal rate with Ar/H_2 plasm... Removal of X-ray-induced carbon contamination on beamline optics was studied using radio-frequency plasma with an argon/hydrogen(Ar/H_2) mixture. Experiments demonstrated that the carbon removal rate with Ar/H_2 plasma was higher than that with pure hydrogen or argon. The possible mechanism for this enhanced removal was discussed. The key working parameters for Ar/H_2 plasma removal were determined, including the optimal vacuum pressure, gas mixing ratio, and source power. The optimal process was performed on a carbon-coated multilayer, and the reflectivity was recovered. 展开更多
关键词 RADIO-FREQUENCY PLASMA x-ray irradiation Carbon CONTAMINATION
下载PDF
Proteomic analysis of energy metabolism and signal transduction in irradiated melanoma cells
16
作者 Lu-Bin Yan Kai Shi +2 位作者 Zhi-Tong Bing Yi-Lan Sun Yang Shen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第3期286-294,共9页
AIM: To analyze proteomic and signal transduction alterations in irradiated melanoma cells. METHODS: We combined stable isotope labeling with amino acids in cell culture (SILAC) with highly sensitive shotgun tandem ma... AIM: To analyze proteomic and signal transduction alterations in irradiated melanoma cells. METHODS: We combined stable isotope labeling with amino acids in cell culture (SILAC) with highly sensitive shotgun tandem mass spectrometry (MS) to create an efficient approach for protein quantification. Protein protein interaction was used to analyze relationships among proteins. RESULTS: Energy metabolism protein levels were significantly different in glycolysis and not significantly different in oxidative phosphorylation after irradiation. Conversely, tumor suppressor proteins related to cell growth and development were downregulated, and those related to cell death and cell cycle were upregulated in irradiated cells. CONCLUSION: Our results indicate that irradiation induces differential expression of the 29 identified proteins closely related to cell survival, cell cycle arrest, and growth inhibition. The data may provide new insights into the pathogenesis of uveal melanoma and guide appropriate radiotherapy. 展开更多
关键词 melanoma cell 2D-LC-MS/MS stable isotope labeling with amino acids proteomic analysis x-ray irradiation protein-protein interaction
下载PDF
重离子引起SiC MOSFET栅氧化物潜在损伤研究 被引量:2
17
作者 于庆奎 曹爽 +8 位作者 张琛睿 孙毅 梅博 王乾元 王贺 魏志超 张洪伟 张腾 柏松 《原子能科学技术》 EI CAS CSCD 北大核心 2023年第12期2254-2263,共10页
针对空间应用,开展SiC MOSFET单粒子效应试验研究。在加速器上用重离子辐照1200 V SiC MOSFET,离子线性能量传输(LET)在0.26~118 MeV·cm^(2)/mg之间,辐照中被试器件加50~600 V静态漏源偏置电压、栅源短接,实时测量电特性,进行辐照... 针对空间应用,开展SiC MOSFET单粒子效应试验研究。在加速器上用重离子辐照1200 V SiC MOSFET,离子线性能量传输(LET)在0.26~118 MeV·cm^(2)/mg之间,辐照中被试器件加50~600 V静态漏源偏置电压、栅源短接,实时测量电特性,进行辐照后栅应力(PIGS)测试。试验结果发现,50~100 V偏置电压下,离子引起瞬态电流,PIGS测试栅失效。分析认为离子引起栅氧化物潜在损伤,PIGS测试过程中,潜在损伤进一步退化导致栅失效。氧化物潜在损伤不仅与辐照偏置电压有关,还与入射离子LET和注量有关。PIGS测试需要的栅应力时间与潜在损伤程度有关,可超过300 s。并给出了电荷累积损伤模型。模型进行SiC MOSFET单粒子效应评估时,应考虑离子引起栅氧化物潜在损伤的影响,需根据轨道和任务周期确定试验离子注量,根据应用情况确定辐照偏置电压,并评估确定PIGS测试栅应力时间。 展开更多
关键词 SiC MOSFET 辐射效应 单粒子效应 单粒子烧毁 单粒子栅穿 潜在损伤 辐照后栅应力
下载PDF
压水堆乏燃料棒涡流探伤技术研究
18
作者 刘歆粤 罗曼 +1 位作者 王华才 朱欣欣 《科技资讯》 2023年第6期95-98,共4页
针对秦山一期核电站辐照后的乏燃料棒探伤检验,该文在热室中建立了一套可远程控制的涡流实验装置,对乏燃料棒进行了全尺寸涡流探伤;检查发现燃料棒包壳完整,无穿壁性缺陷和内外壁裂纹,仅在外表面出现了一些小的划伤;涡流探伤结果与外观... 针对秦山一期核电站辐照后的乏燃料棒探伤检验,该文在热室中建立了一套可远程控制的涡流实验装置,对乏燃料棒进行了全尺寸涡流探伤;检查发现燃料棒包壳完整,无穿壁性缺陷和内外壁裂纹,仅在外表面出现了一些小的划伤;涡流探伤结果与外观检验结果一致,这是首次在国内热室对全尺寸乏燃料棒进行的涡流探伤工作。 展开更多
关键词 涡流探伤 乏燃料棒 热室 压水堆 辐照后检验
下载PDF
高燃耗M5锆合金燃料棒辐照后氧化膜厚度测量技术研究
19
作者 刘歆粤 钱进 +1 位作者 王鑫 王星雨 《科技资讯》 2023年第7期56-59,73,共5页
燃料棒包壳管在堆内高温、高辐照环境中会发生氧化,在表面形成氧化膜。氧化膜会降低燃料组件的热交换能力,加快燃料棒腐蚀速度,使燃料性能恶化,是影响反应堆安全运行的重要因素。针对高燃耗M5锆合金燃料棒辐照后检验在国内罕见相关报道... 燃料棒包壳管在堆内高温、高辐照环境中会发生氧化,在表面形成氧化膜。氧化膜会降低燃料组件的热交换能力,加快燃料棒腐蚀速度,使燃料性能恶化,是影响反应堆安全运行的重要因素。针对高燃耗M5锆合金燃料棒辐照后检验在国内罕见相关报道的现状,开展国产商用压水堆燃料棒辐照性能研究,对改善和提高国产燃料元件的自主化水平具有重要意义。该文用涡流检测和金相检查两种方法对M5锆合金包壳的燃料棒进行了氧化膜厚度测量,并对测量结果进行比较,涡流检测方法结果准确。利用涡流的方法测量氧化膜能方便、准确地获取燃料棒全长范围的氧化膜厚度分布情况,该方法操作简单,测量效率高,为金相检查氧化膜的测量提供依据。适于燃料棒氧化膜轴向厚度分布的测量。 展开更多
关键词 氧化膜测厚 涡流技术 金相分析 热室 辐照后检验 高燃耗
下载PDF
Berberine potentizes apoptosis induced by X-rays irradiation probably through modulation of gap junctions 被引量:5
20
作者 LIU Bing WANG Qin YUAN Dong-dong HONG Xiao-ting TAO Liang 《Chinese Medical Journal》 SCIE CAS CSCD 2011年第8期1221-1228,共8页
Background Clinical combination of some traditional Chinese medical herbs, including berberine, with irradiation is demonstrated to improve efficacy of tumor radiotherapy, yet the mechanisms for such effect remain lar... Background Clinical combination of some traditional Chinese medical herbs, including berberine, with irradiation is demonstrated to improve efficacy of tumor radiotherapy, yet the mechanisms for such effect remain largely unknown. The present study investigated the effect of berberine on apoptosis induced by X-rays irradiation and the relation between this effect and gap junction intercellular communication (GJIC).Methods The role of gap junctions in the modulation of X-rays irradiation-induced apoptosis was explored by manipulation of connexin (Cx) expression, and gap junction function, using oleamide, a GJIC inhibitor, and berberine.Results In transfected HeLa cells, Cx32 expression increased apoptosis induced by X-rays irradiation, while inhibition of gap junction by oleamide reduced the irradiation responses, indicating the dependence of X-rays irradiation-induced apoptosis on GJIC. Berberine, at the concentrations without cytotoxicity, enhanced apoptosis induced by irradiation only in the presence of functional gap junctions.Conclusions These results suggest that berberine potentizes cell apoptosis induced by X-rays irradiation, probably through enhancement of gap junction activity. 展开更多
关键词 BERBERINE gap junctions x-rays irradiation APOPTOSIS
原文传递
上一页 1 2 4 下一页 到第
使用帮助 返回顶部