The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tension...The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability.展开更多
The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyc...The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone.展开更多
This study aimed to evaluate the influence of quartz fiber post placement on the fracture resistance of endodontically treated premolars with different dental defects under dynamic loading.Fifty extracted single-roote...This study aimed to evaluate the influence of quartz fiber post placement on the fracture resistance of endodontically treated premolars with different dental defects under dynamic loading.Fifty extracted single-rooted mandibular premolars were randomized into five groups.Each group was prepared according to numbers of residual walls ranged from 0 to 4.Then each group was divided into two subgroups with one restored with quartz fiber posts and the other without posts.In no-post groups,gutta percha point 2 mm below cemento-enamel junction was removed.Composite resin was adapted to the well and used to shape the core directly.Each tooth was restored with a complete metal crown.Dynamic loading was carried out in a masticatory simulator with a nominal load of 50 N at 2 Hz for 300 000 loading cycles.Then a quasi-statically load was applied in a universal testing machine 306 to the long axis with a crosshead speed of 1 mm?min21until fracture.Data were analyzed with one-way analysis of variance and pairwise comparison(P,0.05).No specimens failed during dynamic loading.The fracture resistance enhanced with the increase of numbers of coronal walls and the differences were significant(P,0.05).Placement of fiber posts had a significant effect when fewer than two walls remained(P,0.05),but it had no significant influence in groups with two,three or four walls(P.0.05).Fiber post did not change failure mode,and the fracture pattern was mainly favorable.More dentin walls need to be retained in clinic.When no less than two walls remained,a fiber post is not always necessary.展开更多
Steel shear wall(SSW) was properly determined using numerical and experimental approaches.The properties of SSW and LYP(low yield point) steel shear wall(LSSW) were measured.It is revealed that LSSW exhibits higher pr...Steel shear wall(SSW) was properly determined using numerical and experimental approaches.The properties of SSW and LYP(low yield point) steel shear wall(LSSW) were measured.It is revealed that LSSW exhibits higher properties compared to SSW in both elastic and inelastic zones.It is also concluded that the addition of CFRP(carbon fiber reinforced polymers) enhances the seismic parameters of LSSW(stiffness,energy absorption,shear capacity,over strength values).Also,stress values applied to boundary frames are lower due to post buckling forces.The effect of fiber angle was also studied and presented as a mathematical equation.展开更多
The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls ...The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.展开更多
Purpose: For post-mastectomy radiation therapy, skin dose must be accurately estimated to assess skin reactions, such as: erythema, desquamation, and necrosis. Even with advanced algorithms, planning systems do not al...Purpose: For post-mastectomy radiation therapy, skin dose must be accurately estimated to assess skin reactions, such as: erythema, desquamation, and necrosis. Even with advanced algorithms, planning systems do not always provide accurate dosimetry for target volumes distal to skin. Methods and Materials: In this study, a female anthropomorphic (ART) phantom and the newest generation of optically stimulated luminescence dosimeters (OSLD) (nanoDots, Landauer Inc.) were deployed to measure chest wall dose distribution. Since actual dose to patients’ lung and heart cannot be measured using in-vivo dosimetry, film was also used to verify the dose distribution to the left lung and heart. The treatment planning was performed using tolerance limits of 95% to 107% of prescription dose. The ART phantom was irradiated according to 3 three-dimensional (3D) conformal radiotherapy plans for 200 cGy dose per fraction using 6 MV medial and lateral tangential photon beams. The dose distribution provided by treatment planning was studied using nanoDots and film. Results: Results show that the largest surface dose difference between nanoDots measurement and prescribed dose for medial and lateral tangential beams, are 3.8% and 9.8%, respectively. This difference may be due to higher effective point of measurement and angular dependence of the nanoDots. The maximum differences in measured dose compared with prescribed dose, using film for heart and the left lung, were 6.2% and 7.5% respectively. Conclusions: Both nanoDots and film provided reasonable estimation of dose distribution in post-mastectomy radiation therapy.展开更多
An original reinforced concrete(RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older(pre-19...An original reinforced concrete(RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older(pre-1999) design standards so that the usual detailing defi ciencies in existing school buildings in Taiwan could be simulated. Two different structural details were chosen to fabricate the full-scale specimens for each retrofi tting technique. The study confi rmed that either RC jacketing or the installation of wing walls with two different structural details can effectively improve the stiffness and strength of an existing column. RC jacketing shows a better improvement in energy dissipation and ductility when compared to the columns with wing walls installed. This is because the two RC jacketed columns experienced a fl exural failure, while a shear failure was found in the two columns with the wing walls installed, and thus led to a drastic decrease of the maximum lateral strengths and ductility. Since many factors may affect the installation of a post-installed anchor, it is better to use standard hooks to replace post-installed anchors in some specifi c points when using RC jacketing or installing wing walls.展开更多
Intraparietal Hernias are hernias occurring in the anterior abdominal wall at different anatomical planes. An interparietal hernia has a hernial sac that passes between the layers of the anterior abdominal wall. Appen...Intraparietal Hernias are hernias occurring in the anterior abdominal wall at different anatomical planes. An interparietal hernia has a hernial sac that passes between the layers of the anterior abdominal wall. Appendectomy is a very common surgical procedure, and post appendectomy incisional hernia is a very rare complication. Here we present a case of a 24-year-old male with swelling in the right hypochondrium and lumbar region with an open appendectomy scar. He was diagnosed to have an interparietal hernia in the anterior abdominal wall. After obtaining consent patient was taken up for surgery. At surgery, the patient was found to have a defect in the transverse abdominis muscle with a medial leaf far from the incision site. Open repair of the defect along with double breasting of external oblique done. Interparietal hernias are rare in post appendectomy scar and this case is of significance since it Highlights a rare interstitial type incisional hernia, as a complication of post appendectomy scar, and not many cases reports are mentioned in literature.展开更多
文摘The unique features of jointed post-tensioned wall systems, which include minimum structural damage and re-centering capability when subjected to earthquake lateral loads, are the result of using unbonded post-tensioning to attach the walls to the foundation, along with employing energy dissipating shear connectors between the walls. Using acceptance criteria defined in terms of inter-story drift, residual drift, and floor acceleration, this study presents a multiplelevel performance-based seismic evaluation of two five-story unbonded post-tensioned jointed precast wall systems. The design and analysis of these two wall systems, established as the direct displacement-based and force-based solutions for a prototype building used in the PREcast Seismic Structural Systems (PRESSS) program, were performed at 60% scale so that the analysis model could be validated using the PRESSS test data. Both buildings satisfied the performance criteria at four levels of earthquake motions although the design base shear of the direct displacement-based jointed wall system was 50% of that demanded by the force-based design method. The study also investigated the feasibility of controlling the maximum transient inter-story drift in a jointed wall system by increasing the number of energy dissipating shear connectors between the walls but without significantly affecting its re-centering capability.
基金Project(200801410005) supported by Doctoral Foundation of Ministry of Education of China
文摘The effects of fire exposure,reinforcement ratio and the presence of axial load under fire on the seismic behavior of reinforced concrete(RC) shear walls were investigated.Five RC shear walls were tested under low cyclic loading.Prior to the cyclic test,three specimens were exposed to fire and two of them were also subjected to a constant axial load.Test results indicate that the ultimate load of the specimen with lower reinforcement ratio is reduced by 15.8%after exposure to elevated temperatures.While the reductions in the energy dissipation and initial stiffness are 59.2%and 51.8%,respectively,which are much higher than those in the ultimate load.However,this deterioration can be slowed down by properly increasing reinforcement due to the strength and stiffness recovery of steel bars after cooling.In addition,the combined action of elevated temperatures and axial load results in more energy dissipation than the action of fire exposure alone.
文摘This study aimed to evaluate the influence of quartz fiber post placement on the fracture resistance of endodontically treated premolars with different dental defects under dynamic loading.Fifty extracted single-rooted mandibular premolars were randomized into five groups.Each group was prepared according to numbers of residual walls ranged from 0 to 4.Then each group was divided into two subgroups with one restored with quartz fiber posts and the other without posts.In no-post groups,gutta percha point 2 mm below cemento-enamel junction was removed.Composite resin was adapted to the well and used to shape the core directly.Each tooth was restored with a complete metal crown.Dynamic loading was carried out in a masticatory simulator with a nominal load of 50 N at 2 Hz for 300 000 loading cycles.Then a quasi-statically load was applied in a universal testing machine 306 to the long axis with a crosshead speed of 1 mm?min21until fracture.Data were analyzed with one-way analysis of variance and pairwise comparison(P,0.05).No specimens failed during dynamic loading.The fracture resistance enhanced with the increase of numbers of coronal walls and the differences were significant(P,0.05).Placement of fiber posts had a significant effect when fewer than two walls remained(P,0.05),but it had no significant influence in groups with two,three or four walls(P.0.05).Fiber post did not change failure mode,and the fracture pattern was mainly favorable.More dentin walls need to be retained in clinic.When no less than two walls remained,a fiber post is not always necessary.
文摘Steel shear wall(SSW) was properly determined using numerical and experimental approaches.The properties of SSW and LYP(low yield point) steel shear wall(LSSW) were measured.It is revealed that LSSW exhibits higher properties compared to SSW in both elastic and inelastic zones.It is also concluded that the addition of CFRP(carbon fiber reinforced polymers) enhances the seismic parameters of LSSW(stiffness,energy absorption,shear capacity,over strength values).Also,stress values applied to boundary frames are lower due to post buckling forces.The effect of fiber angle was also studied and presented as a mathematical equation.
基金National Natural Science Foundation of China(NSFC)under Grant Nos.51638012 and 51578401
文摘The seismic performance of a self-centering precast reinforced concrete (RC) frame with shear walls was investigated in this paper. The lateral force resistance was provided by self-centering precast RC shear walls (SPCW), which utilize a combination ofunbonded prestressed post-tensioned (PT) tendons and mild steel reinforcing bars for flexural resistance across base joints. The structures concentrated deformations at the bottom joints and the unbonded PT tendons provided the self-centering restoring force. A 1/3-scale model of a five-story self-centering RC frame with shear walls was designed and tested on a shake-table under a series of bi-directional earthquake excitations with increasing intensity. The acceleration response, roof displacement, inter-story drifts, residual drifts, shear force ratios, hysteresis curves, and local behaviour of the test specimen were analysed and evaluated. The results demonstrated that seismic performance of the test specimen was satisfactory in the plane of the shear wall; however, the structure sustained inter-story drift levels up to 2.45%. Negligible residual drifts were recorded after all applied earthquake excitations. Based on the shake-table test results, it is feasible to apply and popularize a self-centering precast RC frame with shear walls as a structural system in seismic regions.
文摘Purpose: For post-mastectomy radiation therapy, skin dose must be accurately estimated to assess skin reactions, such as: erythema, desquamation, and necrosis. Even with advanced algorithms, planning systems do not always provide accurate dosimetry for target volumes distal to skin. Methods and Materials: In this study, a female anthropomorphic (ART) phantom and the newest generation of optically stimulated luminescence dosimeters (OSLD) (nanoDots, Landauer Inc.) were deployed to measure chest wall dose distribution. Since actual dose to patients’ lung and heart cannot be measured using in-vivo dosimetry, film was also used to verify the dose distribution to the left lung and heart. The treatment planning was performed using tolerance limits of 95% to 107% of prescription dose. The ART phantom was irradiated according to 3 three-dimensional (3D) conformal radiotherapy plans for 200 cGy dose per fraction using 6 MV medial and lateral tangential photon beams. The dose distribution provided by treatment planning was studied using nanoDots and film. Results: Results show that the largest surface dose difference between nanoDots measurement and prescribed dose for medial and lateral tangential beams, are 3.8% and 9.8%, respectively. This difference may be due to higher effective point of measurement and angular dependence of the nanoDots. The maximum differences in measured dose compared with prescribed dose, using film for heart and the left lung, were 6.2% and 7.5% respectively. Conclusions: Both nanoDots and film provided reasonable estimation of dose distribution in post-mastectomy radiation therapy.
基金the fi nancial support for this study from the Architecture and Building Research Institute,Chinese Taipei,under Grant No.099301070000G1005
文摘An original reinforced concrete(RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older(pre-1999) design standards so that the usual detailing defi ciencies in existing school buildings in Taiwan could be simulated. Two different structural details were chosen to fabricate the full-scale specimens for each retrofi tting technique. The study confi rmed that either RC jacketing or the installation of wing walls with two different structural details can effectively improve the stiffness and strength of an existing column. RC jacketing shows a better improvement in energy dissipation and ductility when compared to the columns with wing walls installed. This is because the two RC jacketed columns experienced a fl exural failure, while a shear failure was found in the two columns with the wing walls installed, and thus led to a drastic decrease of the maximum lateral strengths and ductility. Since many factors may affect the installation of a post-installed anchor, it is better to use standard hooks to replace post-installed anchors in some specifi c points when using RC jacketing or installing wing walls.
文摘Intraparietal Hernias are hernias occurring in the anterior abdominal wall at different anatomical planes. An interparietal hernia has a hernial sac that passes between the layers of the anterior abdominal wall. Appendectomy is a very common surgical procedure, and post appendectomy incisional hernia is a very rare complication. Here we present a case of a 24-year-old male with swelling in the right hypochondrium and lumbar region with an open appendectomy scar. He was diagnosed to have an interparietal hernia in the anterior abdominal wall. After obtaining consent patient was taken up for surgery. At surgery, the patient was found to have a defect in the transverse abdominis muscle with a medial leaf far from the incision site. Open repair of the defect along with double breasting of external oblique done. Interparietal hernias are rare in post appendectomy scar and this case is of significance since it Highlights a rare interstitial type incisional hernia, as a complication of post appendectomy scar, and not many cases reports are mentioned in literature.