期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Mechanical performance of the mixed post-installed connection in low-strength concrete
1
作者 王永泉 陈天骄 景剑 《Journal of Southeast University(English Edition)》 EI CAS 2017年第2期203-208,共6页
Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials toget... Due to inadequate bearing capacity of the chemically-planted steel bar in low-strength concrete, a new mixed post-installed connection is proposed using small diameter anchoring steel bars and grouting materials together to anchor the main steel bar. To investigate the feasibility of the proposed post-installed connections, a series of pull-out tests with different anchors were conducted for comparison,including fully adhesive anchors, partially adhesive anchors,grouting material anchoring connection and the new mixed post-installed connection. The experimental results of the single steel bar pull-out test show that the mixed post-installed connection can effectively enhance the bearing capacity of post-installed steel bars in low-strength concrete. The bearing capacity is increased by nearly two times with no cone-type concrete failure compared with the fully adhesive anchor. The results show that adopting the new mixed post-installed connection can ensure that joint performance meets the requirements if the space dimension is available. 展开更多
关键词 low-strength concrete post-installed connection chemically-planted steel bars bearing capacity failure pattern
下载PDF
Experimental Research on Seismic Performance of Storey-Adding Frame Structures
2
作者 丁红岩 郭耀华 +1 位作者 梁玉国 张浦阳 《Transactions of Tianjin University》 EI CAS 2016年第1期43-49,共7页
The seismic behaviors of an integral concreting frame, a light steel storey-adding frame and a storeyadding frame strengthened with carbon fiber reinforced polymer(CFRP)were investigated under low-cycle and repeated l... The seismic behaviors of an integral concreting frame, a light steel storey-adding frame and a storeyadding frame strengthened with carbon fiber reinforced polymer(CFRP)were investigated under low-cycle and repeated load(scale 1∶3). The failure characteristics, hysteretic behavior, rigidity degeneracy, deflection ductility and energy-dissipation capacity of the three specimens were compared. The test results reveal that chemicallybonded rebar technique can meet the requirements of storey-adding engineering. The carrying capacity, the deflection ductility, the energy-dissipating capacity and seismic performance of the light steel storey-adding frame are higher than those of the integral concreting frame, and they are the highest in the storey-adding frame strengthened with CFRP. 展开更多
关键词 storey-adding frame post-installing rebar technique pseudo-static test seismic performance
下载PDF
Seismic retrofi tting of RC columns with RC jackets and wing walls with different structural details 被引量:2
3
作者 Shuenn-Yih Chang Ting-Wei Chen +1 位作者 Ngoc-Cuong Tran Wen-I Liao 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第2期279-292,共14页
An original reinforced concrete(RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older(pre-19... An original reinforced concrete(RC) column and four strengthened specimens, two with RC jackets and two with wing walls, were tested in this study. The original column specimen was designed to comply with older(pre-1999) design standards so that the usual detailing defi ciencies in existing school buildings in Taiwan could be simulated. Two different structural details were chosen to fabricate the full-scale specimens for each retrofi tting technique. The study confi rmed that either RC jacketing or the installation of wing walls with two different structural details can effectively improve the stiffness and strength of an existing column. RC jacketing shows a better improvement in energy dissipation and ductility when compared to the columns with wing walls installed. This is because the two RC jacketed columns experienced a fl exural failure, while a shear failure was found in the two columns with the wing walls installed, and thus led to a drastic decrease of the maximum lateral strengths and ductility. Since many factors may affect the installation of a post-installed anchor, it is better to use standard hooks to replace post-installed anchors in some specifi c points when using RC jacketing or installing wing walls. 展开更多
关键词 RC jacketing installing wing wall seismic retrofi t non-ductile details post-installed anchors
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部