期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Corrosion resistance of powder injection moulded titanium in physiologic serum and artificial saliva
1
作者 S.Candan M.Turkmen +1 位作者 H.Ahlatci E.Candan 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2010年第3期197-205,共9页
Most of dental implants are made from titanium or titanium based alloys.However, one of the drawback of such implants is high cost due to the technological difficulties in casting method or machining.In this work, pow... Most of dental implants are made from titanium or titanium based alloys.However, one of the drawback of such implants is high cost due to the technological difficulties in casting method or machining.In this work, powder injection moulding(PIM) method has been used in order to explore lower cost implants without minimising the biocorrosion resistance of the titanium.Corrosion resistance of titanium specimens, produced by powder injection moulding method(PIM-Ti), in physiologic serum and artificial saliva was investigated.Commercially pure bulk Ti(CP-Ti) was used as control sample.Surface oxidation was also carried out to both PIMTi and CP-Ti samples.Microstructure and corrosion resistance were investigated using microhardness, X-ray diffraction(XRD), scanning electron microscopy(SEM) and potentiodynamic polarization experiments.Resulting microstructure of PIM-Ti samples contained porosity as compared to CP-Ti control samples.Microhardness of PIM-Ti samples varied with varying applied load whereas it was free from applied load for CP-Ti control samples.Polarisation measurements and SEM analysis revealed that corrosion behaviour of PIM-Ti was reasonably as good as CP-Ti both in as-produced and oxidized conditions in physiologic serum and artificial saliva in spite of its porous structure. 展开更多
关键词 TITANIUM powder injection moulding CORROSION OXIDATION
原文传递
Biocompatibility of MIM 316L stainless steel
2
作者 ZHU Shai-hong WANG Guo-hui +3 位作者 ZHAO Yan-zhong LI Yi-ming ZHOU Ke-chao HUANG Bai-yun 《Journal of Central South University of Technology》 2005年第z1期9-11,共3页
To evaluate the bioeompatibility of MIM 316L stainless steel,the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel,using titanium implant mat... To evaluate the bioeompatibility of MIM 316L stainless steel,the percentage of S-period cells were detected by flow cytometry after L929 incubated with extraction of MIM 316L stainless steel,using titanium implant materials of clinical application as the contrast.Both materials were implanted in animal and the histopathological evaluations were carried out.The statistical analyses show that there are no significant differences between two groups(P>0.05),which demonstrates that MIM 316L stainless steel has a good biocompatibility. 展开更多
关键词 316L stainless steel metal powder injection moulding BIOCOMPATIBILITY flow cytometry
下载PDF
上一页 1 下一页 到第