期刊文献+
共找到182篇文章
< 1 2 10 >
每页显示 20 50 100
Research on the longitudinal protection of a through-type cophase traction direct power supply system based on the empirical wavelet transform
1
作者 Lu Li Zeduan Zhang +5 位作者 Wang Cai Qikang Zhuang Guihong Bi Jian Deng Shilong Chen Xiaorui Kan 《Global Energy Interconnection》 EI CSCD 2024年第2期206-216,共11页
This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a disti... This paper proposes a longitudinal protection scheme utilizing empirical wavelet transform(EWT)for a through-type cophase traction direct power supply system,where both sides of a traction network line exhibit a distinctive boundary structure.This approach capitalizes on the boundary’s capacity to attenuate the high-frequency component of fault signals,resulting in a variation in the high-frequency transient energy ratio when faults occur inside or outside the line.During internal line faults,the high-frequency transient energy at the checkpoints located at both ends surpasses that of its neighboring lines.Conversely,for faults external to the line,the energy is lower compared to adjacent lines.EWT is employed to decompose the collected fault current signals,allowing access to the high-frequency transient energy.The longitudinal protection for the traction network line is established based on disparities between both ends of the traction network line and the high-frequency transient energy on either side of the boundary.Moreover,simulation verification through experimental results demonstrates the effectiveness of the proposed protection scheme across various initial fault angles,distances to faults,and fault transition resistances. 展开更多
关键词 Through-type Cophase traction direct power supply system Traction network Empirical wavelet transform(EWT) Longitudinal protection
下载PDF
Low-frequency oscillation of train-network system considering traction power supply mode
2
作者 Yuchen Liu Xiaoqin Lyu +1 位作者 Mingyuan Chang Qiqi Yang 《Railway Engineering Science》 EI 2024年第2期244-256,共13页
The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified ra... The low-frequency oscillation(LFO)has occurred in the train-network system due to the introduction of the power electronics of the trains.The modeling and analyzing method in current researches based on electrified railway unilateral power supply system are not suitable for the LFO analysis in a bilateral power supply system,where the trains are supplied by two traction substations.In this work,based on the single-input and single-output impedance model of China CRH5 trains,the node admittance matrices of the train-network system both in unilateral and bilateral power supply modes are established,including three-phase power grid,traction transformers and traction network.Then the modal analysis is used to study the oscillation modes and propagation characteristics of the unilateral and bilateral power supply systems.Moreover,the influence of the equivalent inductance of the power grid,the length of the transmission line,and the length of the traction network are analyzed on the critical oscillation mode of the bilateral power supply system.Finally,the theoretical analysis results are verified by the time-domain simulation model in MATLAB/Simulink. 展开更多
关键词 Low-frequency oscillation Train-network system Modal analysis Bilateral power supply Participation factor
下载PDF
Traction power systems for electrified railways:evolution,state of the art,and future trends
3
作者 Haitao Hu Yunjiang Liu +4 位作者 Yong Li Zhengyou He Shibin Gao Xiaojuan Zhu Haidong Tao 《Railway Engineering Science》 EI 2024年第1期1-19,共19页
Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified ... Traction power systems(TPSs)play a vital role in the operation of electrified railways.The transformation of conventional railway TPSs to novel structures is not only a trend to promote the development of electrified railways toward high-efficiency and resilience but also an inevitable requirement to achieve carbon neutrality target.On the basis of sorting out the power supply structures of conventional AC and DC modes,this paper first reviews the characteristics of the existing TPSs,such as weak power supply flexibility and low-energy efficiency.Furthermore,the power supply structures of various TPSs for future electrified railways are described in detail,which satisfy longer distance,low-carbon,high-efficiency,high-reliability and high-quality power supply requirements.Meanwhile,the application prospects of different traction modes are discussed from both technical and economic aspects.Eventually,this paper introduces the research progress of mixed-system electrified railways and traction power supply technologies without catenary system,speculates on the future development trends and challenges of TPSs and predicts that TPSs will be based on the continuous power supply mode,employing power electronic equipment and intelligent information technology to construct a railway comprehensive energy system with renewable energy. 展开更多
关键词 Railway traction power system Future electrified railway Flexible continuous power supply Renewable energy Integrated energy system
下载PDF
Wireless Power Supply Based on MNG-MNZ Metamaterial for Cardiac Pacemakers
4
作者 Weihua Chen Jingtao Jia +2 位作者 Xiaoheng Yan Yuhang Song Jiayi Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第1期103-112,共10页
To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-ne... To solve the low power transfer efficiency and magnetic field leakage problems of cardiac pacemaker wireless powering, we proposed a wireless power supply system suitable for implanted cardiac pacemaker based on mu-negative(MNG) and mu-nearzero(MNZ) metamaterials. First, a hybrid metamaterial consisted of central MNG unit for magnetic field concentration and surrounding MNZ units for magnetic leakage shielding was established by theoretical calculation. Afterwards, the magnetic field distribution of wireless power supply system with MNG-MNZ metamaterial slab was acquired via finite element simulation and verified to be better than the distribution with conventional MNG slab deployed. Finally, an experimental platform of wireless power supply system was established with which power transfer experiment and system temperature rise experiment were conducted.Simulation and experimental results showed that the power transfer efficiency was improved from 44.44%,19.42%, 8.63% and 6.19% to 55.77%, 62.39%, 20.81%and 14.52% at 9.6 mm, 20 mm, 30 mm and 50 mm,respectively. The maximum SAR acquired by SAR simulation under human body environment was-7.14 dbm and maximum reduction of the magnetic field strength around the receiving coil was 2.82 A/m. The maximum temperature rise during 30min charging test was 3.85℃,and the safety requirements of human bodies were met. 展开更多
关键词 Cardiac pacemaker MNG metamaterial MNZ metamaterial Wireless power supply system
下载PDF
Research on uninterruptable power supply technology for auxiliary winding of electric locomotive while passing the neutral section
5
作者 Yuliang Du 《Railway Sciences》 2024年第2期128-142,共15页
Purpose–Auxiliary power system is an indispensable part of the train;the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways,which are either from auxiliary windings of t... Purpose–Auxiliary power system is an indispensable part of the train;the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways,which are either from auxiliary windings of traction transformers or from DC-link voltage of traction converters.Powered by DC-link voltage of traction converters,the auxiliary systems were maintained of uninterruptable power supply with energy from electric braking.Meanwhile,powered by traction transformers,the auxiliary systems were always out of power while passing the neutral section of power supply grid and control system is powered by battery at this time.Design/methodology/approach–Uninterrupted power supply of auxiliary power system powered by auxiliary winding of traction transformer was studied.Failure reasons why previous solutions cannot be realized are analyzed.An uninterruptable power supply scheme for the auxiliary systems powered by auxiliary windings of traction transformers is proposed in this paper.The validity of the proposed scheme is verified by simulation and experimental results and on-site operation of an upgraded HXD3C type locomotive.This scheme is attractive for upgrading practical locomotives with the auxiliary systems powered by auxiliary windings of traction transformers.Findings–This scheme regenerates braking power supplied to auxiliary windings of traction transformers while a locomotive runs in the neutral section of the power supply grid.Control objectives of uninterrupted power supply technology are proposed,which are no overvoltage,no overcurrent and uninterrupted power supply.Originality/value–The control strategies of the scheme ensure both overvoltage free and inrush current free when a locomotive enters or leaves the neutral section.Furthermore,this scheme is cost low by employing updated control strategy of software and add both the two current sensors and two connection wires of hardware. 展开更多
关键词 Electric locomotive Auxiliary system Neutral section Uninterruptable power supply OVERVOLTAGE Inrush current
下载PDF
Electrical characteristics of new three-phase traction power supply system for rail transit 被引量:1
6
作者 Xiaohong Huang Hanlin Wang +4 位作者 Qunzhan Li Naiqi Yang Tao Ren You Peng Haoyang Li 《Railway Engineering Science》 2023年第1期75-88,共14页
A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.... A novel three-phase traction power supply system is proposed to eliminate the adverse effects caused by electric phase separation in catenary and accomplish a unifying manner of traction power supply for rail transit.With the application of two-stage three-phase continuous power supply structure,the electrical characteristics exhibit new features differing from the existing traction system.In this work,the principle for voltage levels determining two-stage network is dissected in accordance with the requirements of traction network and electric locomotive.The equivalent model of three-phase traction system is built for deducing the formula of current distribution and voltage losses.Based on the chain network model of the traction network,a simulation model is established to analyze the electrical characteristics such as traction current distribution,voltage losses,system equivalent impedance,voltage distribution,voltage unbalance and regenerative energy utilization.In a few words,quite a lot traction current of about 99%is undertaken by long-section cable network.The proportion of system voltage losses is small attributed to the two-stage three-phase power supply structure,and the voltage unbal-ance caused by impedance asymmetry of traction network is less than 1‰.In addition,the utilization rate of regenerative energy for locomotive achieves a significant promotion of over 97%. 展开更多
关键词 Three-phase AC power supply Two-stage power supply structure Electrical characteristics Current distribution Voltage losses Regenerative energy
下载PDF
Review of Power Supply and Distribution Construction Technology for Highway Electromechanical Engineering
7
作者 Li Liu 《Journal of Electronic Research and Application》 2024年第2期27-32,共6页
In recent years,China has made significant progress in the construction of highways,resulting in an improved highway network that has provided robust support for economic and social development.However,the rapid expan... In recent years,China has made significant progress in the construction of highways,resulting in an improved highway network that has provided robust support for economic and social development.However,the rapid expansion of highway construction,power supply,and distribution has led to several challenges in mechanical and electrical engineering technology.Ensuring the safe,stable,and cost-effective operation of the power supply and distribution system to meet the diverse requirements of highway operations has become a pressing issue.This article takes an example of a highway electromechanical engineering power supply and distribution construction project to provide insight into the construction process of highway electromechanical engineering power supply and distribution technology. 展开更多
关键词 HIGHWAY Mechanical and electrical engineering power supply and distribution construction technology Construction process
下载PDF
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
8
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
下载PDF
New generation traction power supply system and its key technologies for electrified railways 被引量:6
9
作者 Qunzhan Li 《Journal of Modern Transportation》 2015年第1期1-11,共11页
Unlike the traditional traction power supply system which enables the electrified railway traction sub- station to be connected to power grid in a way of phase rotation, a new generation traction power supply system w... Unlike the traditional traction power supply system which enables the electrified railway traction sub- station to be connected to power grid in a way of phase rotation, a new generation traction power supply system without phase splits is proposed in this paper. Three key techniques used in this system have been discussed. First, a combined co-phase traction power supply system is applied at traction substations for compensating negative sequence current and eliminating phase splits at exits of substations; design method and procedure for this system are presented. Second, a new bilateral traction power supply technology is proposed to eliminate the phase split at section post and reduce the influence of equalizing current on the power grid. Meanwhile, power factor should be adjusted to ensure a proper voltage level of the traction network. Third, a seg- mental power supply technology of traction network is used to divide the power supply arms into several segments, and the synchronous measurement and control technology is applied to diagnose faults and their locations quickly and accurately. Thus, the fault impact can be limited to a min- imum degree. In addition, the economy and reliability of the new generation traction power supply system are analyzed. 展开更多
关键词 New generation traction power supplysystem Combined co-phase power supply Bilateralpower supply Segmental power supply technology Synchronous measurement and control
下载PDF
The Power Supply System for HL-2A Tokamak's Magnetic Field 被引量:6
10
作者 宣伟民 姚列英 +2 位作者 陈宇红 邵葵 王英翘 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第2期211-215,共5页
The highpower pulsed power supply system for the magnetic field of the HL-2A Tokamak is described in this paper. The total output power of its eight magnetic field power supply units of nearly 250 MW. Their highest DC... The highpower pulsed power supply system for the magnetic field of the HL-2A Tokamak is described in this paper. The total output power of its eight magnetic field power supply units of nearly 250 MW. Their highest DC output voltage and current are 3510 V and 45 kA, respectively. All the units are operated in a pulsed mode. The pulse duration is 5 s, and the cyclic period is 15 min. The power supply system consists mainly of pulsed flywheel motor generators, rectifying transformers, thyristor converters, diode rectifiers and switches. The system incorporates many key technologies-supply equalization with two generators and four diode bridges, constant-angle phase triggers with a wide frequency range, current equalization, a status detector for the high current 6-phase converter, and advanced monitoring based on a programmable logic computer and engineering parameter measurement. The experimental results show that the performance of the power supply system satisfies the requirements of HL-2A experiments very well. 展开更多
关键词 high power HL-2A pulsed magnet power supply current equalization exact phase shift
下载PDF
The Power Supply System of Ion Source for NBI 被引量:7
11
作者 刘智民 刘小宁 +6 位作者 胡纯栋 胡立群 刘胜 宋士花 李军 韩筱璞 汪永军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第3期2819-2821,共3页
The power supply system of ion source for the Neutral Beam Injector (NBI) in the HT-7 superconducting tokamak is based on a single injector with one ion source that can deliver 700 kW of neutral beam power. Experiment... The power supply system of ion source for the Neutral Beam Injector (NBI) in the HT-7 superconducting tokamak is based on a single injector with one ion source that can deliver 700 kW of neutral beam power. Experiments and a discharges test on the ion source were successfully performed. In this paper, the circuit structures and features of every power supply are described and the results of the discharges test are presented. 展开更多
关键词 neutral beam injector (NBI) power supply electrical parameter acquisition
下载PDF
Power supply arm protection scheme of high-speed railway based on wide-area current differential
12
作者 Guosong Lin Bin Hong +1 位作者 Zefang Wu Xuguo Fu 《Railway Engineering Science》 2023年第3期281-292,共12页
When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads t... When fault occurs on cross-coupling autotransformer(AT)power supply traction network,the up-line and down-line feeder circuit breakers in the traction substation trip at the same time without selectivity,which leads to an extended power failure.Based on equivalent circuit and Kirchhoff’s current law,the feeder current characteristic in the substation,AT station and sectioning post when T-R fault,F-R fault,and T-F fault occur are analyzed and their expressions are obtained.When the traction power supply system is equipped with wide-area protection measurement and control system,the feeder protection device in each station collects the feeder currents in other two stations through the wide-area protection channel and a wide-area current differential protection scheme based on the feeder current characteristic is proposed.When a short-circuit fault occurs in the power supply arm,all the feeder protection devices in each station receive the feeder currents with time stamp in other two stations.After data synchronous processing and logic judgment,the fault line of the power supply arm can be identified and isolated quickly.The simulation result based on MATLAB/Simulink shows that the power supply arm protection scheme based on wide-area current differential has good fault discrimination ability under different fault positions,transition resistances,and fault types.The verification of measured data shows that the novel protection scheme will not be affected by the special working conditions of the electrical multiple unit(EMU),and reliability,selectivity,and rapidity of relay protection are all improved. 展开更多
关键词 Cross-coupling AT power supply Wide-area current differential power supply arm protection Equivalent circuit High-Speed railway
下载PDF
Coupling Effect between Equilibrium Field and Heating Field and Modification of the Power Supply System on SUNIST Spherical Tokamak 被引量:2
13
作者 何也熙 李晓燕 高喆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第1期2623-2625,共3页
Strong inductive coupling between the heating field and equilibrium field is confirmed to be responsible for the poor plasma equilibrium in initial discharges on the SUNIST spherical tokamak. A modification project fo... Strong inductive coupling between the heating field and equilibrium field is confirmed to be responsible for the poor plasma equilibrium in initial discharges on the SUNIST spherical tokamak. A modification project for the power supply system of equilibrium field coils is successfully performed to increase the duration time of plasma current flattop from much less than 1ms to about 2 ms. 展开更多
关键词 spherical tokamak equilibrium field mutual inductance power supply
下载PDF
Operation Control Method of Relay Protection in Flexible DC Distribution Network Compatible with Distributed Power Supply
14
作者 Zihan Qi 《Energy Engineering》 EI 2023年第11期2547-2563,共17页
A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to... A novel operation control method for relay protection in flexible DC distribution networks with distributed power supply is proposed to address the issue of inaccurate fault location during relay protection,leading to poor performance.The method combines a fault-tolerant fault location method based on long-term and short-term memory networks to accurately locate the fault section.Then,an operation control method for relay protection based on adaptive weight and whale optimization algorithm(WOA)is used to construct an objective function considering the shortest relay protection action time and the smallest impulse current.The adaptive weight and WOA are employed to obtain the optimal strategy for relay protection operation control,reducing the action time and impulse current.Experimental results demonstrate the effectiveness of the proposed method in accurately locating faults and improving relay protection performance.The longest operation time is reduced by 4.7023 s,and the maximum impulse current is limited to 0.3 A,effectively controlling the impact of large impulse currents and enhancing control efficiency. 展开更多
关键词 Compatible distributed power supply FLEXIBILITY DC distribution network relay protection operation control
下载PDF
Design and Simulation for the Pulse High-Voltage DC Power Supply (HVPS) of 1.2 MW/2.45 GHz HT-7U Lower Hybrid Current Drive System 被引量:2
15
作者 黄懿赟 匡光力 +5 位作者 徐伟华 刘保华 林建安 吴君闩 郑光华 杨春生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第6期537-548,共12页
The superconducting tokamak HT-7U [1] has been designed by the Institute of Plasma Physics since 1998 and will be set up before 2003. The 1.2 MW /2.45 GHz HT-7U LHCD (Lower hybrid current drive) system which being the... The superconducting tokamak HT-7U [1] has been designed by the Institute of Plasma Physics since 1998 and will be set up before 2003. The 1.2 MW /2.45 GHz HT-7U LHCD (Lower hybrid current drive) system which being the most efficient non-induction device can heat the plasma and drive the plasma current has been efficiently in operation 'owl and a particular design of the 2.8 MW/-35 kV high-voltage DC power supply has been already completed and will apply to the klystron of LHCD on HT-7 and the future HT-7U, and the project of the power supply has been examined and approved professionally by an authorized group of high-level specialist in the institute of Plasma Physics. The detailed design of the power supply and the simulation results are referred in the paper. 展开更多
关键词 of 1.2 MW/2.45 GHz HT-7U Lower Hybrid Current Drive system LHCD DC Design and Simulation for the Pulse High-Voltage DC power supply HVPS HT
下载PDF
Development of 8 MW Power Supply Based on Pulse Step Modulation Technique for Auxiliary Heating System on HL-2A 被引量:1
16
作者 徐伟东 宣伟民 +1 位作者 姚列英 王英翘 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第3期263-268,共6页
The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its out... The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 t*s. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A. 展开更多
关键词 PSM HV power supply control algorithm switch power supply module
下载PDF
Study on the Current-Sharing Control System of the TF Power Supply for a Superconducting Tokamak 被引量:1
17
作者 朱哲 朱银锋 +2 位作者 黄荣林 傅鹏 丁逸骁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第10期941-946,共6页
The superconducting toroidal field (TF) plays an important role in a superconducting tokamak, whose power supply was developed based on the feedback control principle. In this paper, superconducting tokamaks in diff... The superconducting toroidal field (TF) plays an important role in a superconducting tokamak, whose power supply was developed based on the feedback control principle. In this paper, superconducting tokamaks in different countries are described, and the TF power supply of the International Thermonuclear Experimental Reactor (ITER) is taken as an example to study the current-sharing characteristics in the current-stabilized stage. Firstly, the mathematical model of the TF power supply is established, and then the 3-loop control method is put forward for achieving the stability and reliability of current-stabilization and current-sharing. Furthermore, further studies indicate that the current-sharing controller has no influence on the current-stabilized control, and current-stabilizing and current-sharing can be realized at the same time. All the work done provides valuable references for the current-sharing design of the TF power supply for a superconducting tokamak, and all these studies lay a solid foundation for developing superconducting tokamaks. 展开更多
关键词 superconducting tokamak TF power supply current-sharing control system
下载PDF
Technical Design of Arc-Discharge and Deceleration Power Supply for MW Level NBI System on HL-2A Tokamak 被引量:1
18
作者 陈文光 饶军 +6 位作者 李波 雷光玖 曹建勇 王明伟 康自华 冯鲲 HL-2A NBI Group 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第10期936-940,共5页
Neutral beam injection (NBI) is one of the most effective ways to heat and drive plasma in a tokamak. The mega watt level neutral beam injector on the HL-2A tokamak consists of four high-power ion sources. Each sour... Neutral beam injection (NBI) is one of the most effective ways to heat and drive plasma in a tokamak. The mega watt level neutral beam injector on the HL-2A tokamak consists of four high-power ion sources. Each source is supplied by discharge, beam extraction and auxiliary power supplies. Some circuit topologies and control sequences designed for the system are presented in this paper. Some important technologies such as the notching circuit, insulated gate bipolar transistor (IGBT) series-connected switch, high-frequency switching power supply and control system based on a digital signal processor (DSP) have been used. The system can be effectively used for high current ion beam extraction, protection, ion optics and so on. The power system has been safely used in HL-2A high-parameter NBI experiments for three years. The power of NBI can be kept at higher than 0.75 MW for 1 second and the ion beam power extracted from the ion source is higher than 2 MW. The ion temperature of the plasma center is close to 2.0 keV. These results show that the design of this power system is reasonable and reliable, and it can fully meet the system requirements for NBI of the HL-2A tokamak. 展开更多
关键词 HL-2A neutral beam injector neutral beam injection power supply controlsequence
下载PDF
Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak 被引量:1
19
作者 陶骏 刘正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第1期629-635,共7页
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design... In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load. 展开更多
关键词 In Reactive power Compensation and Harmonic Suppression for power supply system of HT-7U Superconductive Tokamak APF HT
下载PDF
Design and Implementation of Smart Power Voltage and Frequency Synchroniser in Power Distribution System
20
作者 Isaac Kofi Mensah Prah Joseph Cudjoe Attachie 《Journal of Power and Energy Engineering》 2023年第4期1-16,共16页
Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact ... Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact on both voltage and frequency. This paper presents the opportunity for monitoring the distributed electrical energy by means of a system that monitors, controls, and provides a breakpoint based on high or low voltage and frequency tripping mechanism that avoids any damage to the load. The designed system comprised a switch mode power supply (SMPS), a direct digital synthesizer (DDS), and PIC16F876A microcontroller techniques for stable voltage and frequency outputs. Proteus design suite version 8.11 software and Benchcope SDS1102CN were used for modeling and simulation. The hardware prototype was implemented at a telecom cell site for data capturing and analysis. Test results showed that the implementation of the prototype provided stable and constant outputs of 222 V/50 Hz and 112 V/60 Hz which constituted 99% and 99.8% efficiency for voltage and frequency performance respectively. The paper also discusses different technologies that can be adopted by the system to mitigate voltage and frequency effects on customer appliances. 展开更多
关键词 Switch Mode power supply Direct Digital Synthesis Pulse Width Modulation H-Bridge Mosfet MICROCONTROLLER FILTERING and Rectification
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部