In this paper,a multi-bus distributed Power Conditioning Unit(PCU)is proposed for the Space Solar Power Station with large scale photovoltaic(PV)array and power levels reaching MW level.In this unit,there are multiple...In this paper,a multi-bus distributed Power Conditioning Unit(PCU)is proposed for the Space Solar Power Station with large scale photovoltaic(PV)array and power levels reaching MW level.In this unit,there are multiple independent PV arrays.In each PV array,there are multiple independent PV subarrays.In this paper,a V-P droop control method with adaptive droop coefficient is proposed,which modifies the droop intercept based on the bus voltage deviation and the power per unit value of the PV array.This method ensures the accuracy of bus voltage and achieves proportional distribution of power between PV arrays based on the proposed topology structure in this paper.When the load changes or the output power of the PV array fluctuates,this method can ensure that power is distributed proportionally.The principle and control method of the proposed droop control method is analyzed in this paper.The effectiveness of the method is verified through MATLAB/Simulink simulation and experiment.Simulation and experimental results show that the proposed method can achieve power distributed proportionally when load changes and PV output power fluctuates,reduce bus voltage error caused by line impedance and differences in rated power of different PV arrays,and improve the performance of PV power generation system applied to space.展开更多
在先进飞机供电系统中,电源控制器PCU(Power Control Unit)负责对飞机供电系统进行监控和保护,并将供电系统的工作状态信息和PCU本身的工作状态信息传送给上位机,PCU在飞机供电系统的地位很重要;根据现实需要,设计了针对某型号飞机PCU...在先进飞机供电系统中,电源控制器PCU(Power Control Unit)负责对飞机供电系统进行监控和保护,并将供电系统的工作状态信息和PCU本身的工作状态信息传送给上位机,PCU在飞机供电系统的地位很重要;根据现实需要,设计了针对某型号飞机PCU的测试仪,对PCU工作状态进行测试,测试仪负责向PCU提供模拟飞机供电系统工作时的各种信号及飞机供电系统发生故障时的故障信号,即模拟PCU的各种输入信号。展开更多
With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30...With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30% of the maximum load in many cities during summer.This paper proposes a scheme of constructing a virtual peaking unit(VPU) by public buildings’ cool storage central AC(CSCAC) systems and non-CSCAC(NCSCAC)systems for the day-ahead power network dispatching(DAPND). Considering the accumulation effect of different meteorological parameters, a short term load forecasting method of public building’s central AC(CAC) baseline load is firstly discussed. Then, a second-order equivalent thermal parameters model is established for the public building’s CAC load. Moreover, the novel load reduction control strategies for the public building’s CSCAC system and the public building’s NCSCAC system are respectively presented. Furthermore, based on the multiple-rank control strategy, the model of the DAPND with the participation of a VPU is set up. The VPU is composed of large-scale regulated public building’s CAC loads. To demonstrate the effectiveness of the proposed strategy, results of a sample study on a region in Nanjing which involves 22 public buildings’ CAC loads are described in this paper. Simulated results show that, by adopting the proposed DAPND scheme, the power network peak load in the region obviously decreases with a small enough deviation between the regulated load value and the dispatching instruction of the VPU. The total electricity-saving amount accounts for7.78% of total electricity consumption of the VPU before regulation.展开更多
基金supported by the Civil Aerospace Technology Research Project,China(No.D010103)the National Natural Science Foundation of China(Nos.52022075 and U1937202)the National Key R&D Program of China(No.2021YFB3900300).
文摘In this paper,a multi-bus distributed Power Conditioning Unit(PCU)is proposed for the Space Solar Power Station with large scale photovoltaic(PV)array and power levels reaching MW level.In this unit,there are multiple independent PV arrays.In each PV array,there are multiple independent PV subarrays.In this paper,a V-P droop control method with adaptive droop coefficient is proposed,which modifies the droop intercept based on the bus voltage deviation and the power per unit value of the PV array.This method ensures the accuracy of bus voltage and achieves proportional distribution of power between PV arrays based on the proposed topology structure in this paper.When the load changes or the output power of the PV array fluctuates,this method can ensure that power is distributed proportionally.The principle and control method of the proposed droop control method is analyzed in this paper.The effectiveness of the method is verified through MATLAB/Simulink simulation and experiment.Simulation and experimental results show that the proposed method can achieve power distributed proportionally when load changes and PV output power fluctuates,reduce bus voltage error caused by line impedance and differences in rated power of different PV arrays,and improve the performance of PV power generation system applied to space.
文摘在先进飞机供电系统中,电源控制器PCU(Power Control Unit)负责对飞机供电系统进行监控和保护,并将供电系统的工作状态信息和PCU本身的工作状态信息传送给上位机,PCU在飞机供电系统的地位很重要;根据现实需要,设计了针对某型号飞机PCU的测试仪,对PCU工作状态进行测试,测试仪负责向PCU提供模拟飞机供电系统工作时的各种信号及飞机供电系统发生故障时的故障信号,即模拟PCU的各种输入信号。
基金supported by National Key Technology Support Program (No. 2013BAA01B00)National Natural Science Foundation of China (No. 51361130152, No. 51577028)
文摘With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30% of the maximum load in many cities during summer.This paper proposes a scheme of constructing a virtual peaking unit(VPU) by public buildings’ cool storage central AC(CSCAC) systems and non-CSCAC(NCSCAC)systems for the day-ahead power network dispatching(DAPND). Considering the accumulation effect of different meteorological parameters, a short term load forecasting method of public building’s central AC(CAC) baseline load is firstly discussed. Then, a second-order equivalent thermal parameters model is established for the public building’s CAC load. Moreover, the novel load reduction control strategies for the public building’s CSCAC system and the public building’s NCSCAC system are respectively presented. Furthermore, based on the multiple-rank control strategy, the model of the DAPND with the participation of a VPU is set up. The VPU is composed of large-scale regulated public building’s CAC loads. To demonstrate the effectiveness of the proposed strategy, results of a sample study on a region in Nanjing which involves 22 public buildings’ CAC loads are described in this paper. Simulated results show that, by adopting the proposed DAPND scheme, the power network peak load in the region obviously decreases with a small enough deviation between the regulated load value and the dispatching instruction of the VPU. The total electricity-saving amount accounts for7.78% of total electricity consumption of the VPU before regulation.