Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to redu...Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.展开更多
In order to investigate fan performance in fan-ventilated greenhouses(Urbana,USA),the effects of guard screen and loose belts on fan ventilation airflow and power consumption in greenhouse operations were examined wit...In order to investigate fan performance in fan-ventilated greenhouses(Urbana,USA),the effects of guard screen and loose belts on fan ventilation airflow and power consumption in greenhouse operations were examined with four belt-driven fans as trial subjects.The Fans Assessment Numeration System was used to measure the airflow rate.Temperature,relative humidity and power consumption were also monitored.Results show there were significant differences in the airflow rate between the fans with a cleaned and uncleaned guard screen(P<0.05).Power consumption also differed significantly even with the same cooling effect in greenhouse.When fan belts were adjusted to the proper tension,the fan speed and airflow rate were 13.1% and 30.1% higher than those of original belts,respectively.The daily average power consumption for the fan with the original loose belts was 20.4% higher than that with the adjusted belts when the pad was not working and 24.2% higher with pad working.The ventilation performance of fans with identical specifications showed a variation by up to 13.0% in terms of the ventilating efficiency ratio.These results demonstrated that fans should be cleaned routinely,and belt tension should be checked to ensure that fan performance meets specifications.This can reduce the power consumption in greenhouses for environmental control.Moreover,reordering fan staging,so that the most efficient fans are used in areas of greatest demand,can also reduce ventilation energy costs.展开更多
文摘Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.
基金financially support by the Public Welfare Trade(Agriculture)Research Project,China(201203002)the Technology Co-ordination Innovation Project of Shaanxi.Province,China(2011KTDZ02-03-02).
文摘In order to investigate fan performance in fan-ventilated greenhouses(Urbana,USA),the effects of guard screen and loose belts on fan ventilation airflow and power consumption in greenhouse operations were examined with four belt-driven fans as trial subjects.The Fans Assessment Numeration System was used to measure the airflow rate.Temperature,relative humidity and power consumption were also monitored.Results show there were significant differences in the airflow rate between the fans with a cleaned and uncleaned guard screen(P<0.05).Power consumption also differed significantly even with the same cooling effect in greenhouse.When fan belts were adjusted to the proper tension,the fan speed and airflow rate were 13.1% and 30.1% higher than those of original belts,respectively.The daily average power consumption for the fan with the original loose belts was 20.4% higher than that with the adjusted belts when the pad was not working and 24.2% higher with pad working.The ventilation performance of fans with identical specifications showed a variation by up to 13.0% in terms of the ventilating efficiency ratio.These results demonstrated that fans should be cleaned routinely,and belt tension should be checked to ensure that fan performance meets specifications.This can reduce the power consumption in greenhouses for environmental control.Moreover,reordering fan staging,so that the most efficient fans are used in areas of greatest demand,can also reduce ventilation energy costs.