The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D...The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.展开更多
At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important i...At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important indicator of power electronic device designing,losses have always been the focus of attention.At present,the losses are generally measured through experiments,but it takes a lot of time and is difficult to quantitatively analyze the internal distribution of PET losses.To solve the above problems,this article first qualitatively analyzes the losses of power electronic devices and proposes a loss calculation method based on pure simulation.This method uses the Discrete State Event Driven(DSED)modeling method to solve the problem of slow simulation speed of large-capacity power electronic devices and uses a loss calculation method that considers the operating conditions of the device to improve the calculation accuracy.For the PET prototype in this article,a losses model of the PET is established.The comparison of experimental and simulation results verifies the feasibility of the losses model.Then the losses composition of PET was analyzed to provide reference opinions for actual operation.It can help pre-analyze the losses distribution of PET,thereby providing a potential method for improving system efficiency.展开更多
Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs prov...Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%.展开更多
At present, the widely applied mechanical on-load tap-changer is not suitable for the 10 kV power distribution network. Along with the development of power electronic technology, there has the report on on-load tap ch...At present, the widely applied mechanical on-load tap-changer is not suitable for the 10 kV power distribution network. Along with the development of power electronic technology, there has the report on on-load tap changing (OLTC) distributing transformer based on the power electronic technology. In this paper, the analysis on the characteristic of several kinds of non-contacts OLTC distributing transformer was carried on. The result indicates that OLTC distributing transformer based on the solid state relay has the broad applied prospect in the 10 kV medium distribution network.展开更多
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi...This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.展开更多
Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response...Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances.展开更多
As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this articl...As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this article, the device to protect transformer from DC magnetic bias is designed. On the basis of load DC current, a magnetic bias protection device is developed by combination of current sensor, electric information collection circuit, signal filtering circuit, signal modulating circuits, fault feature judging circuit, automatic range tracking circuit, intelligent logic synthesis unit and implementation output circuit. By operating in temperature-rise test equipment in the high power electronic lab, the device is proved with reliability, high sensitivity and worthy of promotion and application.展开更多
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads...A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.展开更多
Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power load...Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power loads and may cause low-frequency oscillation(LFO)to the train-network system.To solve this issue,a mathematical model of the PETT is firstly proposed and verified based on the extended describing function(EDF)method in this paper.In the proposed model,the LLC converter is simplified to an equivalent circuit consisting of a capacitor and a resistor in parallel.It is further demonstrated that the model can apply to various LLC converters with different topologies and controls.Particularly,when the parameter differences between cells are not obvious,the PETT can be simplified to a single-phase rectifier(i.e.,conventional train)by equivalent transformation.Based on the model of PETT,the system low-frequency stability and influential factors are analyzed by using the generalized Nyquist criterion.Lastly,the correctness and accuracy of theoretical analyses are validated by off-line and hardware-in-the-loop simulation results.展开更多
This paper presents a new topology for a High Voltage (HV) 50 kV, High Frequency (HF) 20 kHz, multi-cored transformer suitable for use in pulsed power application systems. The main requirements are: high voltage ...This paper presents a new topology for a High Voltage (HV) 50 kV, High Frequency (HF) 20 kHz, multi-cored transformer suitable for use in pulsed power application systems. The main requirements are: high voltage capability, small size and weight. The HV, HF transformer is the main critical block of a high frequency power converter system. The transformer must have high electrical efficiency and in the proposed approach has to be optimized by the number of the cores. The transformer concept has been investigated analytically and through software simulations and experiments. This paper introduces the transformer topology and discusses the design procedure. Experimental measurements to predict core losses are also presented. The losses of epoxy coated nanocrystalline are compared to the losses in a new uncoated core.展开更多
Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model ...Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model of PETs and applied it to the power flow calculation of AC-DC hybrid systems with PETs,considering the topology,power balance,loss,and control characteristics of multi-port PETs.To address new problems caused by the introduction of the PET port and control equations to the power flow calculation,this study proposes an iterative method of AC-DC mixed power flow decoupling based on step optimization,which can achieve AC-DC decoupling and effectively improve convergence.The results show that the proposed algorithm improves the iterative method and overcomes the overcorrection and initial value sensitivity problems of conventional iterative algorithms.展开更多
The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid moderniz...The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems.展开更多
基金supported by National Key Research and Development Program of China (2016YFB0900500,2017YFB0903100)the State Grid Science and Technology Project (SGRI-DL-F1-51-011)
文摘The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation.
基金the National Key Research and Development Program of China(2017YFB0903200).
文摘At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important indicator of power electronic device designing,losses have always been the focus of attention.At present,the losses are generally measured through experiments,but it takes a lot of time and is difficult to quantitatively analyze the internal distribution of PET losses.To solve the above problems,this article first qualitatively analyzes the losses of power electronic devices and proposes a loss calculation method based on pure simulation.This method uses the Discrete State Event Driven(DSED)modeling method to solve the problem of slow simulation speed of large-capacity power electronic devices and uses a loss calculation method that considers the operating conditions of the device to improve the calculation accuracy.For the PET prototype in this article,a losses model of the PET is established.The comparison of experimental and simulation results verifies the feasibility of the losses model.Then the losses composition of PET was analyzed to provide reference opinions for actual operation.It can help pre-analyze the losses distribution of PET,thereby providing a potential method for improving system efficiency.
文摘Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%.
文摘At present, the widely applied mechanical on-load tap-changer is not suitable for the 10 kV power distribution network. Along with the development of power electronic technology, there has the report on on-load tap changing (OLTC) distributing transformer based on the power electronic technology. In this paper, the analysis on the characteristic of several kinds of non-contacts OLTC distributing transformer was carried on. The result indicates that OLTC distributing transformer based on the solid state relay has the broad applied prospect in the 10 kV medium distribution network.
基金Project supported by the National Natural Science Foundation of China (Grant No.50447006)
文摘This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request.
基金This work was supported by the National Natural Science Foundation of China(51490680,51490683).
文摘Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances.
文摘As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this article, the device to protect transformer from DC magnetic bias is designed. On the basis of load DC current, a magnetic bias protection device is developed by combination of current sensor, electric information collection circuit, signal filtering circuit, signal modulating circuits, fault feature judging circuit, automatic range tracking circuit, intelligent logic synthesis unit and implementation output circuit. By operating in temperature-rise test equipment in the high power electronic lab, the device is proved with reliability, high sensitivity and worthy of promotion and application.
基金This project is financed by the New Century Outstanding Talents Supporting Program of Ministry of Education and Superior Young Teachers Supporting Program of Ministry of Education.
文摘A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads.
基金supported in part by the National Natural Science Foundation of China(52125705)in part by the Natural Science Foundation of Hunan Province(2022JJ40066)。
文摘Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power loads and may cause low-frequency oscillation(LFO)to the train-network system.To solve this issue,a mathematical model of the PETT is firstly proposed and verified based on the extended describing function(EDF)method in this paper.In the proposed model,the LLC converter is simplified to an equivalent circuit consisting of a capacitor and a resistor in parallel.It is further demonstrated that the model can apply to various LLC converters with different topologies and controls.Particularly,when the parameter differences between cells are not obvious,the PETT can be simplified to a single-phase rectifier(i.e.,conventional train)by equivalent transformation.Based on the model of PETT,the system low-frequency stability and influential factors are analyzed by using the generalized Nyquist criterion.Lastly,the correctness and accuracy of theoretical analyses are validated by off-line and hardware-in-the-loop simulation results.
文摘This paper presents a new topology for a High Voltage (HV) 50 kV, High Frequency (HF) 20 kHz, multi-cored transformer suitable for use in pulsed power application systems. The main requirements are: high voltage capability, small size and weight. The HV, HF transformer is the main critical block of a high frequency power converter system. The transformer must have high electrical efficiency and in the proposed approach has to be optimized by the number of the cores. The transformer concept has been investigated analytically and through software simulations and experiments. This paper introduces the transformer topology and discusses the design procedure. Experimental measurements to predict core losses are also presented. The losses of epoxy coated nanocrystalline are compared to the losses in a new uncoated core.
基金supported by the National Key Research and Development Program of China(2017YFB0903300).
文摘Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model of PETs and applied it to the power flow calculation of AC-DC hybrid systems with PETs,considering the topology,power balance,loss,and control characteristics of multi-port PETs.To address new problems caused by the introduction of the PET port and control equations to the power flow calculation,this study proposes an iterative method of AC-DC mixed power flow decoupling based on step optimization,which can achieve AC-DC decoupling and effectively improve convergence.The results show that the proposed algorithm improves the iterative method and overcomes the overcorrection and initial value sensitivity problems of conventional iterative algorithms.
文摘The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems.