This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V proces...This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.展开更多
A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t...A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.展开更多
Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for t...Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for the transformer manufacturer. In this paper an effective and novel method is proposed to determine all components of the iron core losses applying a combination of the empirical and numerical techniques. In this method at the first stage all computable components of the core losses are calculated, using Finite Element Method (FEM) modeling and analysis of the transformer iron core. This method takes into account magnetic sheets anisotropy, joint losses and stacking holes. Next, a Quadratic Programming (QP) optimization technique is employed to estimate the incomputable components of the core losses. This method provides a chance for improvement of the core loss estimation over the time when more measured data become available. The optimization process handles the singular deviations caused by different manufacturing machineries and labor during the transformer manufacturing and overhaul process. Therefore, application of this method enables different companies to obtain different results for the same designs and materials employed, using their historical data. Effectiveness of this method is verified by inspection of 54 full size distribution transformer measurement data.展开更多
xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asym...xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asymmetric three-phase induction motor,supplied by a single-phase source.In this system,capacitor switching is applied during operation,while theoretical and practical results are presented for the application of this switching in a three-phase asymmetric induction motor of 20 hp.展开更多
According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order...According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order to fulfill different dimensional tolerances in the system,adopting 2kfactor design and using the eccentricity ratio corresponding to the stability critical curve,the effects of the friction power loss brought by the dimensional tolerances of the dynamic viscosity,bearing width,bearing diameter and journal diameter were analyzed. The effect on dynamic characteristics of the hydrodynamic journal bearing system was quantitatively analyzed,and the nonlinear dynamic analysis, modeling and calculation methods were studied while considering the manufacturing tolerances. The results show that in contrast to the impacts of the tolerances in journal diameter,dynamic viscosity and bearing width,the bearing diameter tolerance would lead to the rise in the power loss, and the dimensional tolerances have different degrees of impacts on the journal bearing system. The friction power loss decreased as the eccentricity ratio increased, and when the eccentricity ratio was 0. 695 the power loss came to the minimum.The investigation would find the best solution and reduce energy consumption,then control varieties of nonlinear dynamical behavior effectively,and provide a theoretical basis for hydrodynamic journal bearing system in parameter design.展开更多
This paper proposes a novel implementation strategy for soft switching PFC whose circuit is simple and can achieve low voltage output directly. The main circuit adopts current mode full-bridge converter and all the po...This paper proposes a novel implementation strategy for soft switching PFC whose circuit is simple and can achieve low voltage output directly. The main circuit adopts current mode full-bridge converter and all the power switches can realize ZCS or ZVS in the way of phase-shlfted control, using the leakage inductance of the transformer, the junction capacitor of the switches and the stored energy of the output capacitor. The problems such as the function of phase-shlfted link in control circuit, the implementation conditions of soft switching and bias restrained are analyzed. The adoption of constant frequency PWM control makes the design of the input and output filter link and the high frequency transformer simple. The transformation ratio regulation so as to achieve low voltage output and electrical insulation can be realized by using high frequency transformer.展开更多
The energy loss of the power grid is one of the key factors affecting the economic operation of power systems. How to calculate the electric energy consumption accurately will have a great influence on the planning, o...The energy loss of the power grid is one of the key factors affecting the economic operation of power systems. How to calculate the electric energy consumption accurately will have a great influence on the planning, operation and management of the power grid. Currently there is a mountain of theoretical methods to calculate the line loss of the power system. However, these methods have some limitation, such as less considering the volatility of wind power resources. This paper presents an improved method to calculate the energy loss of wind power generation, considering the fluctuations of wind power generation. First, data are collected to obtain the curve of the typical daily expected output of wind farms for one month. Second, the curve of the typical daily expected output are corrected by the average electricity and the shape factor to obtain the curve of the typical daily equivalent output of wind farms for one month. Finally, the power flow is calculated by using typical daily equivalent output curve to describe the energy loss for one month. The results in the 110 kV main network show that the method is feasible.展开更多
The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or...The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or stabi-lity of power in any electric circuit,there are many circuit models are discussed in literature.However,they suffer to maintain the output voltage and not capable of maintaining power stability.To improve the performance in power stabilization,an efficient IC pattern based power factor maximization model(ICPFMM)in this article.The model is focused on improving the power stability with the use of IC(Inductor and Conductor)towards identifying most efficient circuit for the current duty cycle according to the input voltage,voltage in capacitor and output voltage required.The model with boost converter diverts the incoming voltage through number of conductors and inductors.By triggering specific inductor,a specific capacitor gets charged and a particular circuit gets on.The model maintains num-ber of IC(Inductor and Conductor)patterns through which the powerflow occurs.According to that,the pattern available,the mofset controls the level of power to be regulated through any circuit.From the pattern,the model computes the Cir-cuits Switching Loss and Circuits Conduction Loss for various circuits.Accord-ing to the input voltage,the model estimates Circuit Power Stabilization Support(CPSS)according to the voltage available in any capacitor and input voltage.Using the value of CPSS,the model trigger optimal number of circuits to maintain voltage stability.In this approach,more than one circuit has been triggered to maintain output voltage and to get charged.The proposed model not only main-tains power stability but also reduces the wastage in voltage which is not utilized.The proposed model improves the performance in voltage stability with less switching loss.展开更多
The paper dwells on the unified power quality indexes characterizing the phenomenon of voltage unbalance in three-phase systems. Voltage unbalance is one of the commonest occurrences in the town mains of 0.38 kV volta...The paper dwells on the unified power quality indexes characterizing the phenomenon of voltage unbalance in three-phase systems. Voltage unbalance is one of the commonest occurrences in the town mains of 0.38 kV voltage. The phenomenon describes as inequality of vector magnitude of phase voltage and shearing angle between them. Causes and consequences of the voltage unbalance in distribution networks have been considered. The algorithm, which allows switching one-phase load, has been developed as one of the methods of reducing the unbalance level. The algorithm is written in the function block diagram programming language. For determining the duration and magnitude of the unbalance level it is proposed to introduce the forecasting algorithm. The necessary data for forecasting are accumulated in the course of the algorithm based on the Function Block Diagram. The algorithm example is given for transforming substation of the urban electrical power supply system. The results of the economic efficiency assessment of the algorithm implementation are shown in conclusion. The use of automatic switching of the one-phase load for explored substation allows reducing energy losses (active electric energy by 7.63%;reactive energy by 8.37%). It also allows improving supply quality to a consumer. For explored substation the average zero-sequence unbalance factor has dropped from 3.59% to 2.13%, and the negative-sequence unbalance factor has dropped from 0.61% to 0.36%.展开更多
This paper describes the principles of operation and the physical model of an advanced AC-DC converter generator (with the electronic converter acting as an AC-DC rectifier with reverse-conducting MOSFETs (metal-oxi...This paper describes the principles of operation and the physical model of an advanced AC-DC converter generator (with the electronic converter acting as an AC-DC rectifier with reverse-conducting MOSFETs (metal-oxide semiconductor field-effect transistors) as fast-electronic switches with a relatively low ON-state voltage drop) for HSVs. An AC-DC converter, when seen as an AC-DC rectifier, can be used in many fields, e.g., for multi-functional AC-DC/DC-AC convener generator^starter and conventional DC-AC convener motors and AC-DC converter generators or generator sets, welding machines, etc. The paper also describes a novel AC-DC convener, with reverse-conducting transistors and without the use of optoelectronic separation (which does not require a separate power supply), which may be easily realized in IC (integrated-circuit) technology. Computer simulation allows for waveform evaluation for timing analysis of all components of the AC-DC-converter's physical model, both during normal operation as well as in some states of emergency. The paper also presents the results of bench experimental studies where the MOSFETs were used as fast-electronic switches with a relatively low ON-state voltage drop. For experimental studies, a novel AC-DC converter has been put together on the Mitsubishi FM600TU-3A module. The AC-DC converter with reverse-conducting transistors in a double-way connection has a lot of advantages compared to the conventional AC-DC convener acting as a diode rectifier, such as higher energy efficiency and greater reliability resulting from the lower temperature of electronic switches.展开更多
A single-stage single-switch high- frequency electronic ballast topology is presented. The circuit topology is the integration of a buck power- factor-correction (PFC) converter and a class E resonant inverter with ...A single-stage single-switch high- frequency electronic ballast topology is presented. The circuit topology is the integration of a buck power- factor-correction (PFC) converter and a class E resonant inverter with only one active power switch. The buck converter is operated in discontinuous conduction mode and at a fixed switching frequency, and constant duty cycle to achieve high power factor and it can be controlled easily. Detailed analysis of the operation and characteristics of the circuit is provided. Simulation results satisfy present standard requirements.展开更多
文摘This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load.
文摘A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.
文摘Estimation of power transformer no-load loss is a critical issue in the design of distribution transformers. Any deviation in estimation of the core losses during the design stage can lead to a financial penalty for the transformer manufacturer. In this paper an effective and novel method is proposed to determine all components of the iron core losses applying a combination of the empirical and numerical techniques. In this method at the first stage all computable components of the core losses are calculated, using Finite Element Method (FEM) modeling and analysis of the transformer iron core. This method takes into account magnetic sheets anisotropy, joint losses and stacking holes. Next, a Quadratic Programming (QP) optimization technique is employed to estimate the incomputable components of the core losses. This method provides a chance for improvement of the core loss estimation over the time when more measured data become available. The optimization process handles the singular deviations caused by different manufacturing machineries and labor during the transformer manufacturing and overhaul process. Therefore, application of this method enables different companies to obtain different results for the same designs and materials employed, using their historical data. Effectiveness of this method is verified by inspection of 54 full size distribution transformer measurement data.
文摘xThis study has as its objective to collaborate with the expansion in the market of electric energy in rural areas,offering as such an innovative prospect to the solution of associated problems through use of the asymmetric three-phase induction motor,supplied by a single-phase source.In this system,capacitor switching is applied during operation,while theoretical and practical results are presented for the application of this switching in a three-phase asymmetric induction motor of 20 hp.
基金National Natural Science Foundations of China(No.11272100,No.50865001)
文摘According to the dimensional tolerances on hydrodynamic journal bearing system, a nonlinear oil film force model was established,and the Reynolds' equation was solved by adopting finite difference method. In order to fulfill different dimensional tolerances in the system,adopting 2kfactor design and using the eccentricity ratio corresponding to the stability critical curve,the effects of the friction power loss brought by the dimensional tolerances of the dynamic viscosity,bearing width,bearing diameter and journal diameter were analyzed. The effect on dynamic characteristics of the hydrodynamic journal bearing system was quantitatively analyzed,and the nonlinear dynamic analysis, modeling and calculation methods were studied while considering the manufacturing tolerances. The results show that in contrast to the impacts of the tolerances in journal diameter,dynamic viscosity and bearing width,the bearing diameter tolerance would lead to the rise in the power loss, and the dimensional tolerances have different degrees of impacts on the journal bearing system. The friction power loss decreased as the eccentricity ratio increased, and when the eccentricity ratio was 0. 695 the power loss came to the minimum.The investigation would find the best solution and reduce energy consumption,then control varieties of nonlinear dynamical behavior effectively,and provide a theoretical basis for hydrodynamic journal bearing system in parameter design.
基金Sponsored by the Power Electronics Science and Education Development Program of Delta Environmental & Educational Foundation ( Grant No.DREO2006010).
文摘This paper proposes a novel implementation strategy for soft switching PFC whose circuit is simple and can achieve low voltage output directly. The main circuit adopts current mode full-bridge converter and all the power switches can realize ZCS or ZVS in the way of phase-shlfted control, using the leakage inductance of the transformer, the junction capacitor of the switches and the stored energy of the output capacitor. The problems such as the function of phase-shlfted link in control circuit, the implementation conditions of soft switching and bias restrained are analyzed. The adoption of constant frequency PWM control makes the design of the input and output filter link and the high frequency transformer simple. The transformation ratio regulation so as to achieve low voltage output and electrical insulation can be realized by using high frequency transformer.
文摘The energy loss of the power grid is one of the key factors affecting the economic operation of power systems. How to calculate the electric energy consumption accurately will have a great influence on the planning, operation and management of the power grid. Currently there is a mountain of theoretical methods to calculate the line loss of the power system. However, these methods have some limitation, such as less considering the volatility of wind power resources. This paper presents an improved method to calculate the energy loss of wind power generation, considering the fluctuations of wind power generation. First, data are collected to obtain the curve of the typical daily expected output of wind farms for one month. Second, the curve of the typical daily expected output are corrected by the average electricity and the shape factor to obtain the curve of the typical daily equivalent output of wind farms for one month. Finally, the power flow is calculated by using typical daily equivalent output curve to describe the energy loss for one month. The results in the 110 kV main network show that the method is feasible.
文摘The voltagefluctuation in electric circuits has been identified as key issue in different electric systems.As the usage of electricity growing in rapid way,there exist higherfluctuations in powerflow.To maintain theflow or stabi-lity of power in any electric circuit,there are many circuit models are discussed in literature.However,they suffer to maintain the output voltage and not capable of maintaining power stability.To improve the performance in power stabilization,an efficient IC pattern based power factor maximization model(ICPFMM)in this article.The model is focused on improving the power stability with the use of IC(Inductor and Conductor)towards identifying most efficient circuit for the current duty cycle according to the input voltage,voltage in capacitor and output voltage required.The model with boost converter diverts the incoming voltage through number of conductors and inductors.By triggering specific inductor,a specific capacitor gets charged and a particular circuit gets on.The model maintains num-ber of IC(Inductor and Conductor)patterns through which the powerflow occurs.According to that,the pattern available,the mofset controls the level of power to be regulated through any circuit.From the pattern,the model computes the Cir-cuits Switching Loss and Circuits Conduction Loss for various circuits.Accord-ing to the input voltage,the model estimates Circuit Power Stabilization Support(CPSS)according to the voltage available in any capacitor and input voltage.Using the value of CPSS,the model trigger optimal number of circuits to maintain voltage stability.In this approach,more than one circuit has been triggered to maintain output voltage and to get charged.The proposed model not only main-tains power stability but also reduces the wastage in voltage which is not utilized.The proposed model improves the performance in voltage stability with less switching loss.
文摘The paper dwells on the unified power quality indexes characterizing the phenomenon of voltage unbalance in three-phase systems. Voltage unbalance is one of the commonest occurrences in the town mains of 0.38 kV voltage. The phenomenon describes as inequality of vector magnitude of phase voltage and shearing angle between them. Causes and consequences of the voltage unbalance in distribution networks have been considered. The algorithm, which allows switching one-phase load, has been developed as one of the methods of reducing the unbalance level. The algorithm is written in the function block diagram programming language. For determining the duration and magnitude of the unbalance level it is proposed to introduce the forecasting algorithm. The necessary data for forecasting are accumulated in the course of the algorithm based on the Function Block Diagram. The algorithm example is given for transforming substation of the urban electrical power supply system. The results of the economic efficiency assessment of the algorithm implementation are shown in conclusion. The use of automatic switching of the one-phase load for explored substation allows reducing energy losses (active electric energy by 7.63%;reactive energy by 8.37%). It also allows improving supply quality to a consumer. For explored substation the average zero-sequence unbalance factor has dropped from 3.59% to 2.13%, and the negative-sequence unbalance factor has dropped from 0.61% to 0.36%.
文摘This paper describes the principles of operation and the physical model of an advanced AC-DC converter generator (with the electronic converter acting as an AC-DC rectifier with reverse-conducting MOSFETs (metal-oxide semiconductor field-effect transistors) as fast-electronic switches with a relatively low ON-state voltage drop) for HSVs. An AC-DC converter, when seen as an AC-DC rectifier, can be used in many fields, e.g., for multi-functional AC-DC/DC-AC convener generator^starter and conventional DC-AC convener motors and AC-DC converter generators or generator sets, welding machines, etc. The paper also describes a novel AC-DC convener, with reverse-conducting transistors and without the use of optoelectronic separation (which does not require a separate power supply), which may be easily realized in IC (integrated-circuit) technology. Computer simulation allows for waveform evaluation for timing analysis of all components of the AC-DC-converter's physical model, both during normal operation as well as in some states of emergency. The paper also presents the results of bench experimental studies where the MOSFETs were used as fast-electronic switches with a relatively low ON-state voltage drop. For experimental studies, a novel AC-DC converter has been put together on the Mitsubishi FM600TU-3A module. The AC-DC converter with reverse-conducting transistors in a double-way connection has a lot of advantages compared to the conventional AC-DC convener acting as a diode rectifier, such as higher energy efficiency and greater reliability resulting from the lower temperature of electronic switches.
文摘A single-stage single-switch high- frequency electronic ballast topology is presented. The circuit topology is the integration of a buck power- factor-correction (PFC) converter and a class E resonant inverter with only one active power switch. The buck converter is operated in discontinuous conduction mode and at a fixed switching frequency, and constant duty cycle to achieve high power factor and it can be controlled easily. Detailed analysis of the operation and characteristics of the circuit is provided. Simulation results satisfy present standard requirements.