期刊文献+
共找到11,976篇文章
< 1 2 250 >
每页显示 20 50 100
The Optimal Power Flow Calculation of Power System Based on the Annealing Algorithm
1
作者 Xiaodong Yu 《Energy and Power Engineering》 2013年第4期797-802,共6页
The result of OPF whose task is to compute the voltage and angle of each node in power system is the basic of stability calculation and failure analysis in power system. For this goal, the idea of simulated annealing ... The result of OPF whose task is to compute the voltage and angle of each node in power system is the basic of stability calculation and failure analysis in power system. For this goal, the idea of simulated annealing method is introduced, mixed with the greedy randomized algorithm (GRASP), and then the hybrid SA algorithm is obtained. The algorithm is applied to the multi-objective optimal power flow calculation of power system, and the effectiveness of the algorithm given in this paper is verified by analysis of examples. 展开更多
关键词 ANNEALING ALGORITHM power system power flow calculation
下载PDF
Equivalent Method of Integrated Power Generation System of Wind, Photovoltaic and Energy Storage in Power Flow Calculation and Transient Simulation 被引量:10
2
作者 王皓怀 汤涌 +3 位作者 侯俊贤 刘楠 李碧辉 张宏宇 《中国电机工程学报》 EI CSCD 北大核心 2012年第1期I0001-I0026,共26页
针对工程实际开展风光储联合发电系统在潮流计算和机电暂态仿真中的等值方法研究,旨在为大容量风光储联合发电系统的并网仿真分析奠定基础。将潮流计算的等值分为单元机组和集电系统2部分来研究。单元机组等值采用根据不同控制模式选... 针对工程实际开展风光储联合发电系统在潮流计算和机电暂态仿真中的等值方法研究,旨在为大容量风光储联合发电系统的并网仿真分析奠定基础。将潮流计算的等值分为单元机组和集电系统2部分来研究。单元机组等值采用根据不同控制模式选取不同节点类型的方法,针对集电系统等值提出基于损耗不变原则的方法。等值模型和详细模型的算例结果表明,潮流计算等值方法具有较好的精度。在机电暂态仿真动态等值中,基于实际工程计算的最严重工况分析原则,提出运行在满出力点的单机“倍乘”等值模型,为工程计算中的风光储联合发电系统动态等值提供了一种解决方案。 展开更多
关键词 综合发电系统 暂态仿真 光伏发电 潮流计算 等效方法 电力系统 风能 功率
下载PDF
Power Flow Calculation Method of Large Shipboard Power System
3
作者 兰海 李久芳 张殿华 《Journal of Marine Science and Application》 2010年第1期93-98,共6页
The effect of line voltage drop is considered larger on loads, especially on asynchronous motor, transformers and other non-linear load parameters in power system of large ships. A novel power flow method based on imp... The effect of line voltage drop is considered larger on loads, especially on asynchronous motor, transformers and other non-linear load parameters in power system of large ships. A novel power flow method based on improved node voltage method is proposed, and a typical ship power system, which has 2 power stations and 10 nodes, with closed-loop design but open-loop operation, is taken as an example. Simulation results show that the improved power flow calculation method has achieved higher accuracy and better convergence. 展开更多
关键词 power flow method node voltage method asynchronous motor TRANSFORMER
下载PDF
An Augmented Jacobian Method for Power Flow Analysis of Weakly Looped Distribution Systems with PV Buses
4
作者 陈星莺 余昆 单渊达 《Journal of Southeast University(English Edition)》 EI CAS 2002年第3期216-220,共5页
A power flow analysis method for weakly looped distribution systems with PV buses is proposed in this paper. The proposed method is computationally more efficient and more robust compared with the conventional compens... A power flow analysis method for weakly looped distribution systems with PV buses is proposed in this paper. The proposed method is computationally more efficient and more robust compared with the conventional compensation methods. The robustness is achieved by embedding the boundary conditions of loops and PV buses into the Jacobian matrix. The computational efficiency is achieved by the carefully designed factorization of Jacobian matrix. Test results on a 33 bus system are presented. 展开更多
关键词 power flow radial distribution systems weakly loops PV bus
下载PDF
Effect of Types and Orders of Electromagnetic Field Finite Element Meshes on Power Communication Harmonic Parameters Calculation Results of Tubular Hydrogenerators
5
作者 Fan Zhennan Chen Jie +1 位作者 Zhou Zhiting Yang Yong 《China Communications》 SCIE CSCD 2024年第10期288-300,共13页
In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication q... In generator design field,waveform total harmonic distortion(THD)and telephone harmonic factor(THF)are parameters commonly used to measure the impact of generator no-load voltage harmonics on the power communication quality.Tubular hydrogenerators are considered the optimal generator for exploiting low-head,high-flow hydro resources,and they have seen increasingly widespread application in China's power systems recent years.However,owing to the compact and constrained internal space of such generators,their internal magnetic-field harmonics are pronounced.Therefore,accurate calculation of their THD and THF is crucial during the analysis and design stages to ensure the quality of power communication.Especially in the electromagnetic field finite element modeling analysis of such generators,the type and order of the finite element meshes may have a significant impact on the THD and THF calculation results,which warrants in-depth research.To address this,this study takes a real 34 MW large tubular hydrogenerator as an example,and establishes its electromagnetic field finite element model under no-load conditions.Two types of meshes,five mesh densities,and two mesh orders are analyzed to reveal the effect of electromagnetic field finite element mesh types and orders on the calculation results of THD and THF for such generators. 展开更多
关键词 calculation results electromagnetic field finite element meshes power communication harmonic parameters tubular hydrogenerator types and orders
下载PDF
Analysis of Maximum PowerPoint Tracking (MPPT) Adaptability in Inverters of the Three-Phase Photovoltaic Systems Integrated into the Electrical Grid of Congo-Brazzaville
6
作者 Rostand Martialy Davy Loembe Souamy Mavie Grace Mimiesse +4 位作者 Brel Levallois Ndzah Yombi Zonzolo   Guoping Jiang Wanghong Hua Xubao Wen 《Journal of Power and Energy Engineering》 2024年第11期125-152,共28页
This paper investigates the adaptability of Maximum Power Point Tracking (MPPT) algorithms in single-stage three-phase photovoltaic (PV) systems connected to the grid of Congo-Brazzaville and compares the attributes o... This paper investigates the adaptability of Maximum Power Point Tracking (MPPT) algorithms in single-stage three-phase photovoltaic (PV) systems connected to the grid of Congo-Brazzaville and compares the attributes of various conventional, significance and novelty of controller system of the proposed of method and improved Incremental Conductance algorithms, Perturbation and Observation Techniques, and other Maximum Power Point Tracking (MPPT) algorithms in normal and partial shading conditions. Performance evaluation techniques are discussed on the basis of the dynamic parameters of the PV system although the control of this structure is relatively advanced technology but the conversion efficiency is difficult to improve due to increase in transformation series. The single stage topology has a simple topology with high reliability and efficiency because of high power consumption, but control algorithm is more complex because of its power convert main circuit a new strategy is being developed. This paper describes a method for maximum power point tracking (MPPT) in the single-stage and three single-phase PV grid-connected system. In the paper, the nonlinear output characteristics of the PV including I-V & P-V are obtained in changed solar insulations or temperature based on MATLAB, and the MPPT algorithm which is based on the P & O algorithm method, compared with Incremental Conductance, is also described, a dimensioning of the impedance adapter for better stabilization. A comparison SPWM and SVPWM control methods in the case of a grid connection applied to the electrical grid of Republic of Congo and their influences on the dynamic performance of the system and their impact in reducing the harmonic rate for better injection into the grid. The simulation model of three single-phase PV grid-connected system is built, and simulation results show the MPPT algorithm has excellent dynamic and static performances, which verifies the Incremental Conductance is effective for MPPT in the single-stage and three single-phase PV grid-connected system. 展开更多
关键词 Photovoltaic Array CONGO Maximum power Point Tracking Perturbation Observation Incremental Conductance Partial Shading Conditions Performance Evaluation State flow
下载PDF
Mathematical Modeling and Control Algorithm Development for Bidirectional Power Flow in CCS-CNT System
7
作者 Sinqobile Wiseman Nene 《Journal of Power and Energy Engineering》 2024年第9期131-143,共12页
As the demand for more efficient and adaptable power distribution systems intensifies, especially in rural areas, innovative solutions like the Capacitor-Coupled Substation with a Controllable Network Transformer (CCS... As the demand for more efficient and adaptable power distribution systems intensifies, especially in rural areas, innovative solutions like the Capacitor-Coupled Substation with a Controllable Network Transformer (CCS-CNT) are becoming increasingly critical. Traditional power distribution networks, often limited by unidirectional flow capabilities and inflexibility, struggle to meet the complex demands of modern energy systems. The CCS-CNT system offers a transformative approach by enabling bidirectional power flow between high-voltage transmission lines and local distribution networks, a feature that is essential for integrating renewable energy sources and ensuring reliable electrification in underserved regions. This paper presents a detailed mathematical representation of power flow within the CCS-CNT system, emphasizing the control of both active and reactive power through the adjustment of voltage levels and phase angles. A control algorithm is developed to dynamically manage power flow, ensuring optimal performance by minimizing losses and maintaining voltage stability across the network. The proposed CCS-CNT system demonstrates significant potential in enhancing the efficiency and reliability of power distribution, making it particularly suited for rural electrification and other applications where traditional methods fall short. The findings underscore the system's capability to adapt to varying operational conditions, offering a robust solution for modern power distribution challenges. 展开更多
关键词 Capacitor Couple Substation Ferroresonance power flow Control Controllable Network Controller Capacitor-Coupled Substation Incorporating Controllable Network Transformer (CCS-CNT) system system Modeling
下载PDF
Analysis and management strategies for the low voltage problems of rural power grid based on the distribution network flow calculation method 被引量:2
8
作者 陈曦 何俊宏 HE Yu-cheng 《Journal of Chongqing University》 CAS 2015年第4期134-140,共7页
For a long time, because of the lack of investment capital and enough attentions, the overall constructions of rural power grid were far behind than the urban power grid in Chongqing Jiangbei Power Company. The low vo... For a long time, because of the lack of investment capital and enough attentions, the overall constructions of rural power grid were far behind than the urban power grid in Chongqing Jiangbei Power Company. The low voltage problems were highlighted in the rural power grid due to the characteristics of rural power grid. Using the distribution network flow calculation method, we evaluated the low voltage problems of the rural power grid which belongs to Chongqing Jiangbei Power Company. In addition, we collected the data of distribution transformers in electricity consumption peak period. Some practical management strategies were proposed by the analysis and evaluation of potential and appeared low voltage problems. 展开更多
关键词 RURAL power GRID flow calculation method low VOLTAGE PROBLEM management strategy
下载PDF
PASSIVE-ACTIVE CONTROL OF POWER FLOW IN AN ISOLATION SYSTEM MOUNTED ON FLEXIBLE FOUNDATIONS 被引量:2
9
作者 Huo Rui Shi Yin Institute of Naval Ship Equipment Noise & Vibration, Naval University of Engineering Song Kongjie Shandong University of Technology 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第2期111-115,共5页
A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function... A general model of flexible isolation systems which involves both the passive and active control factors is established by inserting actuators into an passive isolation system. And the power flow transmission function in such a system as with multi disturbance, multi mounts, passive isolators and actuators is deduced. By means of the numerical simulation method, the influence of actuators on power flow transmission characteristic is studied. And as a conclusion, the passive active synthetic control strategy of power flow is summarized. 展开更多
关键词 Vibration isolation power flow COUPLING Active control
下载PDF
Power flow calculation for a distribution system with multi-port PETs:an improved AC-DC decoupling iterative method 被引量:6
10
作者 Hang Yin Qiang Li +3 位作者 Youbo Liu Xianglong Liu Yue Xiang Junyong Liu 《Global Energy Interconnection》 2020年第4期313-323,共11页
Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model ... Recently,power electronic transformers(PETs)have received widespread attention owing to their flexible networking,diverse operating modes,and abundant control objects.In this study,we established a steady-state model of PETs and applied it to the power flow calculation of AC-DC hybrid systems with PETs,considering the topology,power balance,loss,and control characteristics of multi-port PETs.To address new problems caused by the introduction of the PET port and control equations to the power flow calculation,this study proposes an iterative method of AC-DC mixed power flow decoupling based on step optimization,which can achieve AC-DC decoupling and effectively improve convergence.The results show that the proposed algorithm improves the iterative method and overcomes the overcorrection and initial value sensitivity problems of conventional iterative algorithms. 展开更多
关键词 power electronic transformers AC-DC distribution systems AC-DC mixed power flow algorithm
下载PDF
Research and application of a power-flow-calculation method in multiterminal VSC-HVDC power grid 被引量:8
11
作者 Linlin Wu Xiaowei Fan +4 位作者 Man Xu Zhendong Li Xiao Wang Xiaofei Zhang Haiwang Jin 《Global Energy Interconnection》 2019年第1期37-44,共8页
For demonstrating a multiterminal voltage-source converter(VSC)-based high-voltage DC(HVDC)(VSCHVDC) project, this study puts forward a technical route for calculating the power flow in a 500-kV VSC-HVDC power grid in... For demonstrating a multiterminal voltage-source converter(VSC)-based high-voltage DC(HVDC)(VSCHVDC) project, this study puts forward a technical route for calculating the power flow in a 500-kV VSC-HVDC power grid in comparison with that of an AC power grid. The Jacobian matrix used in the power-flow calculation was deduced through methods such as Newton–Laphson iteration and Taylor series expansion. Further, the operation effect of powerflow calculation on a true bipolar VSC-HVDC power grid was analyzed briefly. The elements of the Jacobian matrix corresponding to VSC were studied under the mode of droop control and the control strategy of VSC-HVDC power grid was analyzed in detail. The power-flow calculation model for VSC-HVDC power grid of the master–slave control mode was simplified using the PQ decomposition method of the power-flow calculation of an AC power grid. Moreover, a four-terminal model of the Zhangbei VSC-HVDC demonstration project was established and tested on MATLAB. The simulation results under two kinds of operating conditions were analyzed and compared to the results of BPA; the deviation between the power-flow results was studied. The results show that the proposed calculation method can provide a feasible support for calculating the power flow in VSC-HVDC grids. 展开更多
关键词 VSC-HVDC grids power-flow calculation JACOBIAN MATRIX Droop control
下载PDF
Analysis of the Load Flow Problem in Power System Planning Studies 被引量:1
12
作者 Olukayode A. Afolabi Warsame H. Ali +3 位作者 Penrose Cofie John Fuller Pamela Obiomon Emmanuel S. Kolawole 《Energy and Power Engineering》 2015年第10期509-523,共15页
Load flow is an important tool used by power engineers for planning, to determine the best operation for a power system and exchange of power between utility companies. In order to have an efficient operating power sy... Load flow is an important tool used by power engineers for planning, to determine the best operation for a power system and exchange of power between utility companies. In order to have an efficient operating power system, it is necessary to determine which method is suitable and efficient for the system’s load flow analysis. A power flow analysis method may take a long time and therefore prevent achieving an accurate result to a power flow solution because of continuous changes in power demand and generations. This paper presents analysis of the load flow problem in power system planning studies. The numerical methods: Gauss-Seidel, Newton-Raphson and Fast Decoupled methods were compared for a power flow analysis solution. Simulation is carried out using Matlab for test cases of IEEE 9-Bus, IEEE 30-Bus and IEEE 57-Bus system. The simulation results were compared for number of iteration, computational time, tolerance value and convergence. The compared results show that Newton-Raphson is the most reliable method because it has the least number of iteration and converges faster. 展开更多
关键词 Load flow Bus GAUSS-SEIDEL NEWTON-RAPHSON Fast Decoupled VOLTAGE MAGNITUDE VOLTAGE Angle Active power Reactive power ITERATION Convergence
下载PDF
The Measuring System for Estimation of Power of Wind Flow Generated by Train Movement and Its Experimental Testing
13
作者 Oleksandr Mokin Borys Mokin Vadym Bazalytskyy 《Energy and Power Engineering》 2014年第11期333-339,共7页
The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and ... The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and easy build-up of channels, designed measuring system can be used for a wide range of technical problems. This paper describes the design process, validation and conducting the first field test of this measuring system. 展开更多
关键词 power Generation WIND TURBINE WIND flow Sensor Measurement
下载PDF
Design and Power Flow Analysis of Electrical System Using Electrical Transient and Program Software
14
作者 Raheel Muzzammel Ibrahim Khail +2 位作者 Muhammad Huzaifa Tariq Abubakar Muhammad Asghar Ali Hassan 《Energy and Power Engineering》 2019年第4期186-199,共14页
Power flow analysis is a numerical way of study of behavior of flow of electric power in an interconnected system. In order to meet the growing demands of electrical energy in an optimum way, there is a need to upgrad... Power flow analysis is a numerical way of study of behavior of flow of electric power in an interconnected system. In order to meet the growing demands of electrical energy in an optimum way, there is a need to upgrade existing systems or to install new systems. Therefore, planning of new installations and determination of best operating conditions of existing systems need power flow analysis. In this way, cost/benefit ratio for both suppliers and customers is maintained. This research involves the design and power flow analysis of IEEE-14 bus system. Newton Raphson method is applied for better efficiency and reduced computational time. Simulation analysis is conducted in ETAP software because of its excessive used in real life systems. 展开更多
关键词 power flow Analysis IEEE-14 BUS system NEWTON Raphson Method ETAP SofTWARE
下载PDF
A probabilistic power flow calculation method considering the uncertainty of the static frequency characteristic
15
作者 Yi Wang Xiufen Shen Zemei Dai 《Global Energy Interconnection》 2019年第1期45-53,共9页
In a power system, power generation and load have frequency response characteristics, which randomly fluctuate with changes in operating status. This study investigates a probabilistic power flow method that considers... In a power system, power generation and load have frequency response characteristics, which randomly fluctuate with changes in operating status. This study investigates a probabilistic power flow method that considers the unit and load uncertainty of the static frequency characteristic. Firstly, a calculation model is established on the basis of the characteristics of the frequency modulation performance of the unit and load. Then a calculation method is developed using the concept of dynamic power flow in order to determine the probability distribution of the active power flow of each line under the occurrence of a fault in the system. In the method, Monte Carlo sampling with the semi-invariant method is applied for analysis and calculation. The IEEE-30-buses system is taken as an example to analyze the impact of different responses of units on the power flow distribution of various branches. The method discussed herein is compared with the Monte Carlo simulation method to verify its effectiveness. 展开更多
关键词 UNCERTAINTY of frequency characteristics PROBABILISTIC power flow CUMULANT method Quasi-steady STATE sen sitivity formatting
下载PDF
Security Constrained Distributed Optimal Power Flow of Interconnected Power Systems
16
作者 哈比比 余贻鑫 《Transactions of Tianjin University》 EI CAS 2008年第3期208-216,共9页
The security constrained distributed optimal power flow (DOPF) of interconnected power systems is presented. The centralized OPF problem of the multi-area power systems is decomposed into independent DOPF subproblem... The security constrained distributed optimal power flow (DOPF) of interconnected power systems is presented. The centralized OPF problem of the multi-area power systems is decomposed into independent DOPF subproblems, one for each area. The dynamic security region (DSR) to guarantee the transient stability constraints and static voltage stability region (SVSR) constraints, and line current limits are included as constraints. The solutions to the DOPF subproblems of the different areas are coordinated through a pricing mechanism until they converge to the centralized OPF solution. The nonlinear DOPF subproblem is solved by predictor-corrector interior point method (PClPM). The IEEE three-area RTS-96 system is worked out in order to demonstrate the effectiveness of the proposed method. 展开更多
关键词 distributed optimal power flow interior point method predictor-corrector method security region
下载PDF
Solving Load Flow Problems of Power System by Explicit Pseudo-Transient Continuation (E-ψtc) Method
17
作者 Tianmin Han Yuhuan Han 《Energy and Power Engineering》 2016年第2期99-115,共17页
This paper is a further study of two papers [1] and [2], which were related to Ill-Conditioned Load Flow Problems and were published by IEEE Trans. PAS. The authors of this paper have some different opinions, for exam... This paper is a further study of two papers [1] and [2], which were related to Ill-Conditioned Load Flow Problems and were published by IEEE Trans. PAS. The authors of this paper have some different opinions, for example, the 11-bus system is not an ill-conditioned system. In addition, a new approach to solve Load Flow Problems, E-&psi;tc, is introduced. It is an explicit method;solving linear equations is not needed. It can handle very tough and very large systems. The advantage of this method has been fully proved by two examples. The authors give this new method a detailed description of how to use it to solve Load Flow Problems and successfully apply it to the 43-bus and the 11-bus systems. The authors also propose a strategy to test the reliability, and by solving gradient equations, this new method can answer if the solution exists or not. 展开更多
关键词 Load flow Problems of power system Ill-Conditioned system Normal Newton Method Optimal Multiplier Method Brown Method Explicit Pseudo-Transient Continuation (E-ψtc) 11-Bus and 43-Bus systems Reliability Gradient Equation
下载PDF
A NEW MODELING METHOD FOR MACHINE-FOUNDATION COUPLING SYSTEM AND ITS APPLICATION TO THE CONTROL OF POWER FLOW 被引量:3
18
作者 Xiong Yeping Shandong University of Technology 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1999年第2期44-50,共7页
A new concept, namely, the equivalent mobility matrix of coupling subsystem is proposed, and the corresponding threesubsystem coupling progressive approach is explored. With the new efficient approach presented, the c... A new concept, namely, the equivalent mobility matrix of coupling subsystem is proposed, and the corresponding threesubsystem coupling progressive approach is explored. With the new efficient approach presented, the complexity in dealing with a more complicated dynamic coupling system is greatly reduced. The new modeling method is then combined with the theory of power flow to investigate the dynamics of the overall non rigid isolation system from the viewpoint of energy. The interaction between the resilient machine of its main modes and the resonant behavior of the flexible foundation on power flow transmission is studied. Taking a machine tool mounted on a multi story working plant as an example, the dynamic characteristics of the machine foundation coupling system are analyzed, and their effects on power flow transmission are revealed under various service frequency bands. Some advisable control strategies and the design principle for machinery mounted on flexible structure are proposed. 展开更多
关键词 Modeling method power flow Resilient machine Flexible foundation Subsystem Vibration control
全文增补中
Three-Phase Optimal Power Flow for Study of PV Plant Distributed Impact on Distribution Systems
19
作者 Malinwo E. Ayikpa Katia C. de Almeida Guilherme C. Danielski 《Journal of Electrical Engineering》 2017年第1期47-56,共10页
This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or abs... This paper presents a TOPF (three-phase optimal power flow) model that represents photovoltaic systems. The PV plant is modeled in the TOPF as active and reactive power source. Reactive power can be generated or absorbed using the available capacity and the adjustable power factor of the inverter. The reduction of unbalance voltage and losses in the distribution systems is obtained by actions of reactive power control of the inverter. The TOPF is formulated by current balance equations and the PV systems are modeled via an equivalent circuit. The primal-dual interior point method is used to obtain the optimal operating points for the systems for different scenarios of solar irradiance and temperature, thus providing a detailed view of the impact of photovoltaic distributed generation. 展开更多
关键词 Three-phase optimal power flow photovoltaic generation unbalance voltage LOSS primal-dual interior point method.
下载PDF
Research on Verification Method of Motor Startups in Nuclear Power Plants Based on Topology Recognition
20
作者 Li Baozhu Dong Weijie Chen Chao 《系统仿真学报》 CAS CSCD 北大核心 2024年第12期2813-2823,共11页
There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive softw... There are many motors in operation or on standby in nuclear power plants,and the startup of group motors will have a great impact on the voltage of the emergency bus.At present,there is no special or inexpensive software to solve this problem,and the experience of engineers is not accurate enough.Therefore,this paper developed a method and system for the startup calculation of group motors in nuclear power plants and proposed an automatic generation method of circuit topology in nuclear power plants.Each component in the topology was given its unique number,and the component class could be constructed according to its type and upper and lower connections.The subordination and topology relationship of switches,buses,and motors could be quickly generated by the program according to the component class,and the simplified direct power flow algorithm was used to calculate the power flow for the startup of group motors according to the above relationship.Then,whether the bus voltage is in the safe range and whether the voltage exceeds the limit during the startup of the group motor could be judged.The practical example was used to verify the effectiveness of the method.Compared with other professional software,the method has high efficiency and low cost. 展开更多
关键词 power supply for nuclear power plant automatic topology recognition startup of group motor simplified direct power flow algorithm verification method
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部