The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated...The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.展开更多
The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose a...The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose and localize faults in the rectifier,this paper proposes a frequencydomain analysis-based fault diagnosis algorithm for the rectifier in AGPS.First,time-domain expressions and spectral characteristics of the output voltage of the TPTL-NPC inverter-based power supply are analyzed.Then,frequency-domain analysis-based fault diagnosis and frequency-domain analysis-based sub-fault diagnosis algorithms are proposed to diagnose open circuit(OC) faults of diode(s),which benefit from the analysis of harmonics magnitude and phase-angle of the output voltage.Only a fundamental period is needed to diagnose and localize exact faults,and a strong Variable-duration Fault Detection Method is proposed to identify acceptable ripple from OC faults.Detailed simulations and experimental results demonstrate the effectiveness,quickness,and robustness of the proposed algorithms,and the diagnosis algorithms proposed in this article provide a significant method for the fault diagnosis of other rectifiers and converters.展开更多
This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field ...This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.展开更多
基金supported in part by the National Key Research and Development Program of China(No.2017YFE0300104)in part by National Natural Science Foundation of China(No.51821005)。
文摘The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly.
基金supported by the National Key R&D Program of China(No.2017YFE0300104)National Natural Science Foundation of China(No.51821005)
文摘The acceleration grid power supply(AGPS) is a crucial part of the Negative-ion Neutral Beam Injection system in the China Fusion Engineering Test Reactor,which includes a 3-phase passive(diode) rectifier.To diagnose and localize faults in the rectifier,this paper proposes a frequencydomain analysis-based fault diagnosis algorithm for the rectifier in AGPS.First,time-domain expressions and spectral characteristics of the output voltage of the TPTL-NPC inverter-based power supply are analyzed.Then,frequency-domain analysis-based fault diagnosis and frequency-domain analysis-based sub-fault diagnosis algorithms are proposed to diagnose open circuit(OC) faults of diode(s),which benefit from the analysis of harmonics magnitude and phase-angle of the output voltage.Only a fundamental period is needed to diagnose and localize exact faults,and a strong Variable-duration Fault Detection Method is proposed to identify acceptable ripple from OC faults.Detailed simulations and experimental results demonstrate the effectiveness,quickness,and robustness of the proposed algorithms,and the diagnosis algorithms proposed in this article provide a significant method for the fault diagnosis of other rectifiers and converters.
基金The project supported by the Meg-science Engineering Project of the Chinese Academy of Sciences
文摘This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.