期刊文献+
共找到5,036篇文章
< 1 2 250 >
每页显示 20 50 100
Simulation realization of skip cycle mode integrated control circuit in the switching power supply with low standby loss 被引量:2
1
作者 屈艾文 程东方 冯旭 《Journal of Shanghai University(English Edition)》 CAS 2007年第3期318-322,共5页
This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V proces... This paper explores and proposes a design solution of an integrated skip cycle mode (SCM) control circuit with a simple structure. The design is simulated and implemented with XD10H-1.0μm modular DIMOS 650 V process. In order to meet the requirement of a wide temperature range and high yields of products, the schematic extracted from the layout is simulated with five process corners at 27℃ and 90℃. Simulation results demonstrate that the proposed integrated circuit is immune to noise and achieves skipping cycle control when switching mode power supply (SMPS) works with low load or without load. 展开更多
关键词 standby loss skip cycle mode (SCM) switching mode power supply (SMPS) integrated control circuit.
下载PDF
High-power High-efficient and Simplified High-frequency Switching Power Supply for Electrolytic Plating 被引量:6
2
作者 MA Fujun LUO An XIAO Huagen 《中国电机工程学报》 EI CSCD 北大核心 2012年第21期I0001-I0022,共22页
针对大功率电解电镀开关电源的输入整流级引起的无功和谐波等电能质量问题,研究了一种基于高效PWM整流的高频开关电源。该电源前级整流器仅用4个开关管来进行PWM整流,后级采用半桥逆变器进行高频变换,显著减少了开关数量。针对三相四开... 针对大功率电解电镀开关电源的输入整流级引起的无功和谐波等电能质量问题,研究了一种基于高效PWM整流的高频开关电源。该电源前级整流器仅用4个开关管来进行PWM整流,后级采用半桥逆变器进行高频变换,显著减少了开关数量。针对三相四开关PWM整流器,推导一种基于开关模型的无差拍控制方法,该方法可实现系统的快速、无差整流。针对多台开关电源的并联均流问题,提出一种基于虚拟阻抗的自均流控制方法,可实现多台电源的均流稳定运行。通过仿真与实验验证了所提结构和控制方法的正确性。 展开更多
关键词 高频开关电源 电镀电源 电解 PWM整流器 高功率 半桥式逆变器 电能质量 HSPS
下载PDF
Development of 8 MW Power Supply Based on Pulse Step Modulation Technique for Auxiliary Heating System on HL-2A 被引量:1
3
作者 徐伟东 宣伟民 +1 位作者 姚列英 王英翘 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第3期263-268,共6页
The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its out... The high voltage power supply (HVPS) based on pulse step modulation (PSM) has already been developed for the auxiliary heating system on HL-2A. This power supply consists of many switch power supplies, and its output voltage can be obtained by modulating their delay time and pulse widths. The PSM topology and control principle are presented in this paper. The simple algorithms for the control system are explained clearly. The switch power supply (SPS) module has been built and the test results show it can meet the requirements of the auxiliary heating system. Now, 112 SPS modules and the whole system have already been developed. Its maximum output is about 72 kV/93 A. The protection time is less than 5 t*s. The different outputs of this power supply are used for the electron cyclotron resonant heating (ECRH) system with different duty ratios. The experimental results of the entire system are presented. The results indicate that the whole system can meet the requirements of the auxiliary heating system on HL-2A. 展开更多
关键词 PSM HV power supply control algorithm switch power supply module
下载PDF
Design of intrinsically safe power supply 被引量:3
4
作者 LI Rui-jin JIN Lin 《Journal of Coal Science & Engineering(China)》 2012年第4期443-448,共6页
关键词 本质安全型 电源安全 设计 数学模型 煤矿生产 放电能量 基础研究 高功率
下载PDF
The Design and Application of Intelligent Power Supply System of Integrated Meteorological Business at the County Level
5
作者 Yang Changda Zhang Jinyong +2 位作者 Gu Heng Yang Ping Shu Dongxiang 《Meteorological and Environmental Research》 CAS 2017年第5期56-60,共5页
The system uses Japanese Mitsubishi PLC as the main control core,and intermediate relay is used for signal acquisition and conversion.The system is mainly composed of data processing module,municipal electricity monit... The system uses Japanese Mitsubishi PLC as the main control core,and intermediate relay is used for signal acquisition and conversion.The system is mainly composed of data processing module,municipal electricity monitoring module,wireless communication module,remote controller,speech recognition module,display module,sensor,switching output module and UPS power supply. The system can automatically start generator for power supply when municipal electricity is failure; when municipal electricity returns to normal,it automatically restores the power supply function of municipal electricity. In order to improve the stability of the system,the system has the functions of fault alarm,remote reset and remote query,etc.,which can realize seamless switching of municipal electricity and generator. It effectively avoids meteorological data loss,data delay,network interruption,etc. caused by unstable municipal electricity,solves the power supply problem of grass-roots meteorological station,especially at night,provides stable power supply for the integrated meteorological observation,forecasting,and early warning service. 展开更多
关键词 MITSUBISHI PLC INTELLIGENT power supply SEAMLESS switching METEOROLOGICAL BUSINESS
下载PDF
A Novel Method of Auxiliary Power Supply Used in Wide-Range High Voltage Input DC-DC Converter
6
作者 Jie Zhang Liangjie Li Cuicui Liu 《Energy and Power Engineering》 2017年第4期703-712,共10页
In high voltage input DC-DC converter, auxiliary winding of isolation transformer is usually used to supply power for control circuit. Due to the wide-range of input voltage, the variable output voltage of auxiliary w... In high voltage input DC-DC converter, auxiliary winding of isolation transformer is usually used to supply power for control circuit. Due to the wide-range of input voltage, the variable output voltage of auxiliary winding will cause a series of problems, such as variable drive pulse amplitude, increased driver switching devices loss and drive transformer core saturation. This paper analyzes the influence of variable output voltage of auxiliary winding in detail. A novel method is proposed to solve the problem of large variation range of auxiliary winding output voltage, which is adding a buck converter between the auxiliary winding and the control circuit. A dual switch forward convert has been designed with 300 V - 800 V input and 24 V/5 A output. The results show that this method is effective by comparing the different results of using buck converter or not. 展开更多
关键词 Dual Switch Forward CONVERTER Wide-Range INPUT AUXILIARY WINDING of power supply BUCK CONVERTER
下载PDF
A Study of High-Power Thyristor Switch of Poloidal-Field Power Supply System in HT-7U Super-Conductive Tokamak
7
作者 温家良 刘正之 +1 位作者 付鹏 许家治 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第5期1005-1010,共6页
Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simul... Through theoretical analysis of thyristor switch, criterion of turn-off was derived for the design of thyristor switch. The expression of parameter design and its math model during the turn-off were deduced. The simulation and experiment have been accomplished to validate the analysis. 展开更多
关键词 A Study of High-power Thyristor Switch of Poloidal-Field power supply System in HT-7U Super-Conductive Tokamak HT
下载PDF
Grid-Connected Emergency Back-Up Power Supply
8
作者 Dhiman Chowdhury Mohammad Sharif Miah Md. F. Hossain 《Circuits and Systems》 2019年第1期1-19,共19页
This paper documents design and modeling of a grid-connected emergency back-up power supply for medium power applications. Back-up power supplies are very important in regard to support electrical loads in the events ... This paper documents design and modeling of a grid-connected emergency back-up power supply for medium power applications. Back-up power supplies are very important in regard to support electrical loads in the events of grid power outage. However, grid-integration of a back-up power supply substantiates continual power transfer to the loads, especially to the critical loads, which should not suffer from power interruptions. Therefore, design and circuit modeling of switching converters based reliable grid-tied emergency back-up power supply are presented in this paper. There are a rectifier-link boost derived battery charging circuit and a 4-switch push-pull power inverter circuit which are controlled by high frequency pulse width modulation (PWM) signals. This paper presents a state averaging model and Laplace domain transfer function of the charging circuit and a switching converter model of the power inverter circuit. A changeover relay based transfer switch controls the power flow towards the utility loads. During off-grid situations, loads are fed power by the proposed inverter circuit and during on-grid situations, battery is charged by an ac-link rectifier-fed boost converter. However, there is a relay switching circuit to control the charging phenomenon of the battery. The proposed design is simulated in PLECS and the simulation results corroborate the reliability of the presented framework. 展开更多
关键词 BACK-UP power supply LAPLACE Domain PUSH-PULL Inverter State AVERAGING MODEL switching Converter MODEL
下载PDF
Digital arc welding power supply based on real-time operating system
9
作者 张红兵 黄石生 周漪清 《China Welding》 EI CAS 2007年第3期1-5,共5页
A digital arc welding power supply was designed with the advanced reduced instruction set computer machine (ARM) and embedded real-time multi-task operating system micro C/OS- Ⅱ. The ARM, with its powerful calculat... A digital arc welding power supply was designed with the advanced reduced instruction set computer machine (ARM) and embedded real-time multi-task operating system micro C/OS- Ⅱ. The ARM, with its powerful calculating speed and complete peripheral equipments, is very suitable to work as the controller of the digital power supply. The micro C/OS- Ⅱ transplanted in ARM, helps to improve the respondent speed against various welding signals, as well as the reliability of the controlling software. The welding process consists of nine tasks. The tasks of great significance on reliability of the welder, for example, the A/D conversion of current and voltage, enjoy top priority. To avoid simultaneous-sharing on A/D converter and LCD module, two semaphores are introduced in to ensure the smooth performance of the welding power supply. Proven by experiments ,the ARM and the micro C/OS- Ⅱ can greatly improve both the respondent speed and the reliability of the digital welder. 展开更多
关键词 micro C/OS-Ⅱ real-time operating system DIGITIZATION arc welding power supply
下载PDF
Design and Simulation of a Electrorheological(ER) Control High Voltage Power Supply
10
作者 ZHU Shi-sha HUANG He-qing BAI Quan 《International Journal of Plant Engineering and Management》 2009年第3期142-146,共5页
Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power ... Few applications with electrorheological (ER) fluids have been found in industry. One reason is high voltage power supplies cannot meet the requirement for ER effect. In this paper, an ER control high voltage power supply for engineering application was designed which reduced power wastage by adopting soft switch technology; lessened its volume to satisfy micromation when adopting the planar transformer and improved its response character- istic by choosing an assistant discharging circuit. Simultaneously, a simulation analysis has been carried out. As results, the output voltage of this high voltage power supply is 5 kV, and the voltage can be continuously regulated and the voltage ripple is only 0. 7 %, so the requirement of stability is also achieved. 展开更多
关键词 ER control high voltage power supply application design soft switch technology SIMULATION
下载PDF
Consideration of the influence of supports in modeling the electromagnetic fields of 25 kV traction networks under emergency conditions
11
作者 Konstantin Suslov Andrey Kryukov +1 位作者 Ekaterina Voronina Pavel Ilyushin 《Global Energy Interconnection》 EI CSCD 2024年第4期528-540,共13页
Single-phase 25 kV traction networks of electrified alternating current(AC)railways create electromagnetic fields(EMFs)with significant levels of intensity.The most intense magnetic fields occur when short circuits ex... Single-phase 25 kV traction networks of electrified alternating current(AC)railways create electromagnetic fields(EMFs)with significant levels of intensity.The most intense magnetic fields occur when short circuits exist between the contact wire and rails or ground.Despite the short duration of exposure,they can adversely affect electronic devices and induce significant voltages in adjacent power lines,which is dangerous for operating personnel.Although numerous investigations have focused on modeling the EMF of traction networks and power lines,the challenge of determining the three-dimensional electromagnetic fields near metal supports during the flow of a short-circuit current through them is yet to be resolved.In this case,the field has a complex spatial structure that significantly complicates the calculations of intensities.This study proposes a methodology,algorithms,software,and digital models for determining the EMF in the described emergency scenarios.During the modeling process,the objects being studied were represented by segments of thin wires to analyze the distribution of the electric charge and calculate the intensities of the electric and magnetic fields.This approach was implemented in the Fazonord software,and the modeling results show a substantial increase in EMF levels close to the support,with a noticeable decrease in the levels as the distance from it increases.The procedure implemented in the commercial software Fazonord is universal and can be used to determine electromagnetic fields at any electrical power facility that includes live parts of limited length.Based on the proposed procedure,the EMF near the supports of overhead power lines and traction networks of various designs could be determined,the EMF levels at substations can be calculated,and the influence of metal structures located near traction networks,such as pedestrian crossings at railway stations,can be considered. 展开更多
关键词 power supply systems AC railways emergency conditions Electromagnetic fields near supports MODELING Electromagnetic safety
下载PDF
Design and Implementation of Smart Power Voltage and Frequency Synchroniser in Power Distribution System
12
作者 Isaac Kofi Mensah Prah Joseph Cudjoe Attachie 《Journal of Power and Energy Engineering》 2023年第4期1-16,共16页
Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact ... Voltage and frequency are usually considered and assessed independently in the design and operation of electrical networks. However, these two are linked. Each and every malfunctioning electrical system has an impact on both voltage and frequency. This paper presents the opportunity for monitoring the distributed electrical energy by means of a system that monitors, controls, and provides a breakpoint based on high or low voltage and frequency tripping mechanism that avoids any damage to the load. The designed system comprised a switch mode power supply (SMPS), a direct digital synthesizer (DDS), and PIC16F876A microcontroller techniques for stable voltage and frequency outputs. Proteus design suite version 8.11 software and Benchcope SDS1102CN were used for modeling and simulation. The hardware prototype was implemented at a telecom cell site for data capturing and analysis. Test results showed that the implementation of the prototype provided stable and constant outputs of 222 V/50 Hz and 112 V/60 Hz which constituted 99% and 99.8% efficiency for voltage and frequency performance respectively. The paper also discusses different technologies that can be adopted by the system to mitigate voltage and frequency effects on customer appliances. 展开更多
关键词 Switch Mode power supply Direct Digital Synthesis Pulse Width Modulation H-Bridge Mosfet MICROCONTROLLER FILTERING and Rectification
下载PDF
Study on a Highly Stabilized Power Supply for Hybrid-Magnet Superconducting Outsert 被引量:2
13
作者 吴景林 龙佼佼 刘小宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第9期890-896,共7页
The superconducting outsert of the 40 T hybrid-magnet in High Magnetic Field Laboratory (HMFL) of Chinese Academy of Sciences (CAS) requires a highly stabilized power supply. In this paper, two kinds of power supp... The superconducting outsert of the 40 T hybrid-magnet in High Magnetic Field Laboratory (HMFL) of Chinese Academy of Sciences (CAS) requires a highly stabilized power supply. In this paper, two kinds of power supply design are briefly presented and both advantages and disadvantages are analyzed. In order to overcome the drawbacks of switching power supply, a series regulated active filter is adopted and a new design is proposed which ensures cooperative relationship between the feedback control loops of the switching converter and the series regulated active filter. Besides, unlike the traditional switching power supply, which can generate positive voltage only, this new design can also generate negative voltage which is needed in the quench protection for the superconducting magnet. In order to demonstrate the effectiveness of the methodology, a low-power prototype has been accomplished. The simulation and experiment results show that the power supply achieves high precision under the combined action of two feedback control loops. The peak-to-peak amplitude of the output ripple voltage of the prototype is 0.063%, while the peak-to-peak amplitude of the output ripple current is 120 ppm. 展开更多
关键词 superconducting magnet switching power supply series regulating feedbackcontrol quench protection
下载PDF
Reducing the minimum output power of soft-switching inverter arc welding power supplies 被引量:1
14
作者 傅强 薛松柏 《China Welding》 EI CAS 2010年第3期45-49,共5页
The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topolo... The full-bridge zero-voltage and zero-current switching inverter, which can adjust the output power by keeping the duty-cycle of lagging arm constant, changing the duty-cycle of leading arm, is a common circuit topology of soft-switching inverter arc welding power supplies. However, the output power still remains a certain value when the duty-cycle of leading arm decreases to zero. The working-mode of soft-switching inverter and the waveforms of major parameters with the condition of duty-cycle of leading arm being zero are studied in this paper. U-1 characteristic experiments prove that the minimum output power of soft-switching circuit, which depends on the charged voltage of capacitors in parallel with leading arm, can be decreased by reducing the duty-cycle of lagging arm. By switching working-modes between half-bridge and full-bridge, the output power can swing from zero to the power rating. 展开更多
关键词 SofT-switching inverter arc welding power supplies minimum output power
下载PDF
A Novel Half-Bridge Power Supply for High Speed Drilling Electrical Discharge Machining
15
作者 He Huang Jicheng Bai +1 位作者 Zesheng Lu Yongfeng Guo 《Journal of Electromagnetic Analysis and Applications》 2009年第2期108-113,共6页
High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manu... High Speed Drilling Electrical Discharge Machining (HSDEDM) uses controlled electric sparks to erode the metal in a work-piece. Through the years, HSDEDM process has widely been used in high speed drilling and in manufacturing large aspect ratio holes for hard-to-machine material. The power supplies of HSDEDM providing high power applica-tions can have different topologies. In this paper, a novel Pulsed-Width-Modulated (PWM) half-bridge HSDEDM power supply that achieves Zero-Voltage-Switching (ZVS) for switches and Zero-Current-Switching (ZCS) for the dis-charge gap has been developed. This power supply has excellent features that include minimal component count and inherent protection under short circuit conditions. This topology has an energy conservation feature and removes the need for output bulk capacitors and resistances. Energy used in the erosion process will be controlled by the switched IGBTs in the half-bridge network and be transferred to the gap between the tool and work-piece. The relative tool wear and machining speed of our proposed topology have been compared with that of a normal power supply with current limiting resistances. 展开更多
关键词 High Speed DRILLING Electrical Discharge Machining Half-Bridge power supply ZERO Current switching ZERO Voltage switching
下载PDF
Analysis of Switching Overvoltage in Regional Grid with Small Hydropower Plants
16
作者 Juan Chen Haifeng Li 《Engineering(科研)》 2013年第9期19-23,共5页
Present-day small hydropower plants (SHPs) have a large development potential because of the increasing interest in renewable resources and distributed energy generation, therefore, there are many SHPs in places of Ch... Present-day small hydropower plants (SHPs) have a large development potential because of the increasing interest in renewable resources and distributed energy generation, therefore, there are many SHPs in places of China where are rich in water resources. However, it has caused overvoltages in the distribution network, and which is even worse for the switching overvoltage such as isolated network operation, changing power supply path. The simple network model is used to analyze the reasons of the switching overvoltage, and the simulation software DIgSILENT/PowerFactory is used to check out the results of the theoretical analysis. 展开更多
关键词 Small HYDROpower ISOLATED Operation CHANGING power supply PATH switching OVERVOLTAGE
下载PDF
Study on Transformer Magnetic Biasing Control Method for AC Power Supplies 被引量:5
17
作者 卢家林 孙晋 苏彦民 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2001年第4期17-22,共6页
This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing ... This paper presents a novel transformer magnetic biasing control method for high-power high-performance AC power supplies. Serious consequences due to magnetic biasing and several methods to overcome magnetic biasing are first discussed. The causes of the transformer magnetic biasing are then analyzed in detail. The proposed method is based on a high-pass filter inserted in the forward path and the feedforward control. Without testing magnetic biasing of transformer, this method can eliminate magnetic biasing of transformer completely in real-time waveform feedback control systems though the zero error of the Hall effect sensors varies with time and temperature. The method has already been employed in a 90KVA AC power supply. It is shown that it offers improved performance over existing ones. In this method, no sensors are used such that the zero error of the Hall effect sensors has not any influence on the system. It is simple to design and implement. Furthermore, the method is suitable for various power applications. 展开更多
关键词 AC machinery Electric power supplies to apparatus Feedback control Hall effect High pass filters Real time systems SENSORS
下载PDF
基于PowerEsim的开关电源的高频变压器设计 被引量:1
18
作者 杨文广 杨玉岗 +1 位作者 李洪珠 高奇 《仪器仪表用户》 2009年第2期70-71,共2页
高频开关电源中,变压器受更多寄生参数的影响,对开关电源的影响也越来越大。因此,高频开关电源设计时,高频变压器的设计是重中之重。本文对高频变压器的设计进行了分析,应用PowerEsim软件对变压器的参数进行了优化,提高了开关电源的效率。
关键词 高频开关电源 高频变压器 powerEsim
下载PDF
POWER 4-5-6仿真软件及其应用
19
作者 沙占友 安涛 《电源技术应用》 2008年第3期59-64,共6页
开关电源的计算机仿真过程是首先根据实际电路建立数学模型,然后对数学模型进行形进行分析和研究,达到与实际制作开关电源相同的目的。介绍开关电源仿真软件POWER 4-5-6的主要特点及拓扑结构,重点阐述利用POWER 4-5-6设计开关电源功率... 开关电源的计算机仿真过程是首先根据实际电路建立数学模型,然后对数学模型进行形进行分析和研究,达到与实际制作开关电源相同的目的。介绍开关电源仿真软件POWER 4-5-6的主要特点及拓扑结构,重点阐述利用POWER 4-5-6设计开关电源功率级的方法和控制电路的小信号分析。 展开更多
关键词 开关电源 计算机仿真 功率级 小信号分析
下载PDF
Air-Water Cooling System for Switch-Mode Power Supplies
20
作者 G. Casano S. Piva 《Journal of Electronics Cooling and Thermal Control》 2015年第3期66-75,共10页
The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by... The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced. 展开更多
关键词 SWITCH MODE power supply SMPS Cold-Plate COOLING System THERMAL Design
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部