期刊文献+
共找到33,300篇文章
< 1 2 250 >
每页显示 20 50 100
Increasing the Efficiency and Level of Environmental Safety of Pro-Environmental City Heat Supply Technologies by Low Power Nuclear Plants
1
作者 Vladimir Kravchenko Igor Kozlov +3 位作者 Volodymyr Vashchenko Iryna Korduba Andrew Overchenko Serhii Tsybytovskyi 《World Journal of Nuclear Science and Technology》 CAS 2024年第2期107-117,共11页
In connection with the current prospect of decarbonization of coal energy through the use of small nuclear power plants (SNPPs) at existing TPPs as heat sources for heat supply to municipal heating networks, there is ... In connection with the current prospect of decarbonization of coal energy through the use of small nuclear power plants (SNPPs) at existing TPPs as heat sources for heat supply to municipal heating networks, there is a technological need to improve heat supply schemes to increase their environmental friendliness and efficiency. The paper proves the feasibility of using the heat-feeding mode of ASHPs for urban heat supply by heating the network water with steam taken from the turbine. The ratio of electric and thermal power of a “nuclear” combined heat and power plant is given. The advantage of using a heat pump, which provides twice as much electrical power with the same heat output, is established. Taking into account that heat in these modes is supplied with different potential, the energy efficiency was used to compare these options. To increase the heat supply capacity, a scheme with the use of a high-pressure heater in the backpressure mode and with the heating of network water with hot steam was proposed. Heat supply from ASHPs is efficient and environmentally friendly even in the case of significant remoteness of heat consumers. 展开更多
关键词 Low-Capacity Nuclear power plants Environmental Friendliness of the Thermal power Generation Mode heat Generation Condensation Mode heat Supply
下载PDF
Off-Design Simulation of a CSP Power Plant Integrated with aWaste Heat Recovery System
2
作者 T.E.Boukelia A.Bourouis +1 位作者 M.E.Abdesselem M.S.Mecibah 《Energy Engineering》 EI 2023年第11期2449-2467,共19页
Concentrating Solar Power(CSP)plants offer a promising way to generate low-emission energy.However,these plants face challenges such as reduced sunlight during winter and cloudy days,despite being located in high sola... Concentrating Solar Power(CSP)plants offer a promising way to generate low-emission energy.However,these plants face challenges such as reduced sunlight during winter and cloudy days,despite being located in high solar radiation areas.Furthermore,their dispatch capacities and yields can be affected by high electricity consumption,particularly at night.The present work aims to develop an off-design model that evaluates the hourly and annual performances of a parabolic trough power plant(PTPP)equipped with a waste heat recovery system.The study aims to compare the performances of this new layout with those of the conventional Andasol 1 plant,with the aim of assessing the improvements achieved in the new design.Based on the results,it can be concluded that the new layout has increased the annual generated power to almost 183 GWh(an increase of about 7.60% is achieved compared to the Andasol 1 layout that generates 169 GWh annually).Additionally,the proposed installation has achieved an efficiency of 20.55%,which represents a 7.87% increase compared to the previous design(19.05%).The Levelized Cost of Electricity(LCOE)of the new layout has been reduced by more than 5.8% compared to the Andasol 1 plant.Specifically,it has decreased from 13.11 to 12.35 c/kWh.This reduction in LCOE highlights the improved cost-effectiveness of the newlayout,making it amore economically viable option for generating electricity compared to the conventional Andasol 1 plant. 展开更多
关键词 Dispatch capacity organic Rankine cycle parabolic trough solar power plant PERFORMANCES waste heat recovery
下载PDF
A Special Issue:“Key Technologies of Virtual Power Plant and Distributed Energy Resources”for Global Energy Interconnection
3
《Global Energy Interconnection》 EI CSCD 2024年第2期I0002-I0003,共2页
The increasing penetration of renewable and distributed energy resources(DERs)is transforming the power grid into a new type of clean and low-carbon power system.However,the uncertainty and volatility of DERs have als... The increasing penetration of renewable and distributed energy resources(DERs)is transforming the power grid into a new type of clean and low-carbon power system.However,the uncertainty and volatility of DERs have also brought severe challenges to the secure and reliable operation of the power systems.In order to successfully integrate renewable DERs,virtual power plant(VPP)has emerged as a new technique for coordinating demand-side DERs,which has drawn significant attention from industry and academia. 展开更多
关键词 plant power INTEGRATE
下载PDF
Virtual Power Plants for Grid Resilience: A Concise Overview of Research and Applications
4
作者 Yijing Xie Yichen Zhang +2 位作者 Wei-Jen Lee Zongli Lin Yacov A.Shamash 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第2期329-343,共15页
The power grid is undergoing a transformation from synchronous generators(SGs) toward inverter-based resources(IBRs). The stochasticity, asynchronicity, and limited-inertia characteristics of IBRs bring about challeng... The power grid is undergoing a transformation from synchronous generators(SGs) toward inverter-based resources(IBRs). The stochasticity, asynchronicity, and limited-inertia characteristics of IBRs bring about challenges to grid resilience. Virtual power plants(VPPs) are emerging technologies to improve the grid resilience and advance the transformation. By judiciously aggregating geographically distributed energy resources(DERs) as individual electrical entities, VPPs can provide capacity and ancillary services to grid operations and participate in electricity wholesale markets. This paper aims to provide a concise overview of the concept and development of VPPs and the latest progresses in VPP operation, with the focus on VPP scheduling and control. Based on this overview, we identify a few potential challenges in VPP operation and discuss the opportunities of integrating the multi-agent system(MAS)-based strategy into the VPP operation to enhance its scalability, performance and resilience. 展开更多
关键词 Climate change renewable energy resources RESILIENCE smart grids virtual power plants(VPPs)
下载PDF
Quantification of CO_(2) Emissions from Three Power Plants in China Using OCO-3 Satellite Measurements
5
作者 Yang YANG Minqiang ZHOU +3 位作者 Wei WANG Zijun NING Feng ZHANG Pucai WANG 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第11期2276-2288,共13页
Coal-fired power plants are a major carbon source in China. In order to assess the evaluation of China's carbon reduction progress with the promise made on the Paris Agreement, it is crucial to monitor the carbon ... Coal-fired power plants are a major carbon source in China. In order to assess the evaluation of China's carbon reduction progress with the promise made on the Paris Agreement, it is crucial to monitor the carbon flux intensity from coal-fired power plants. Previous studies have calculated CO_(2) emissions from point sources based on Orbiting Carbon Observatory-2 and-3(OCO-2 and OCO-3) satellite measurements, but the factors affecting CO_(2) flux estimations are uncertain. In this study, we employ a Gaussian Plume Model to estimate CO_(2) emissions from three power plants in China based on OCO-3 XCO_(2) measurements. Moreover, flux uncertainties resulting from wind information, background values,satellite CO_(2) measurements, and atmospheric stability are discussed. This study highlights the CO_(2) flux uncertainty derived from the satellite measurements. Finally, satellite-based CO_(2) emission estimates are compared to bottom-up inventories.The satellite-based CO_(2) emission estimates at the Tuoketuo and Nongliushi power plants are ~30 and ~10 kt d^(-1) smaller than the Open-Data Inventory for Anthropogenic Carbon dioxide(ODIAC) respectively, but ~10 kt d^(-1) larger than the ODIAC at Baotou. 展开更多
关键词 OCO-3 power plant CO_(2)emission Gaussian Plume Model
下载PDF
GRU-integrated constrained soft actor-critic learning enabled fully distributed scheduling strategy for residential virtual power plant
6
作者 Xiaoyun Deng Yongdong Chen +2 位作者 Dongchuan Fan Youbo Liu Chao Ma 《Global Energy Interconnection》 EI CSCD 2024年第2期117-129,共13页
In this study,a novel residential virtual power plant(RVPP)scheduling method that leverages a gate recurrent unit(GRU)-integrated deep reinforcement learning(DRL)algorithm is proposed.In the proposed scheme,the GRU-in... In this study,a novel residential virtual power plant(RVPP)scheduling method that leverages a gate recurrent unit(GRU)-integrated deep reinforcement learning(DRL)algorithm is proposed.In the proposed scheme,the GRU-integrated DRL algorithm guides the RVPP to participate effectively in both the day-ahead and real-time markets,lowering the electricity purchase costs and consumption risks for end-users.The Lagrangian relaxation technique is introduced to transform the constrained Markov decision process(CMDP)into an unconstrained optimization problem,which guarantees that the constraints are strictly satisfied without determining the penalty coefficients.Furthermore,to enhance the scalability of the constrained soft actor-critic(CSAC)-based RVPP scheduling approach,a fully distributed scheduling architecture was designed to enable plug-and-play in the residential distributed energy resources(RDER).Case studies performed on the constructed RVPP scenario validated the performance of the proposed methodology in enhancing the responsiveness of the RDER to power tariffs,balancing the supply and demand of the power grid,and ensuring customer comfort. 展开更多
关键词 Residential virtual power plant Residential distributed energy resource Constrained soft actor-critic Fully distributed scheduling strategy
下载PDF
Proposal of a Deuterium-Deuterium Fusion Reactor Intended for a Large Power Plant
7
作者 Patrick Lindecker 《World Journal of Nuclear Science and Technology》 CAS 2024年第1期1-58,共58页
This article looks for the necessary conditions to use Deuterium-Deuterium (D-D) fusion for a large power plant. At the moment, for nearly all the projects (JET, ITER…) only the Deuterium-Tritium (D-T) fuel is consid... This article looks for the necessary conditions to use Deuterium-Deuterium (D-D) fusion for a large power plant. At the moment, for nearly all the projects (JET, ITER…) only the Deuterium-Tritium (D-T) fuel is considered for a power plant. However, as shown in this article, even if a D-D reactor would be necessarily much bigger than a D-T reactor due to the much weaker fusion reactivity of the D-D fusion compared to the D-T fusion, a D-D reactor size would remain under an acceptable size. Indeed, a D-D power plant would be necessarily large and powerful, i.e. the net electric power would be equal to a minimum of 1.2 GWe and preferably above 10 GWe. A D-D reactor would be less complex than a D-T reactor as it is not necessary to obtain Tritium from the reactor itself. It is proposed the same type of reactor yet proposed by the author in a previous article, i.e. a Stellarator “racetrack” magnetic loop. The working of this reactor is continuous. It is reminded that the Deuterium is relatively abundant on the sea water, and so it constitutes an almost inexhaustible source of energy. Thanks to secondary fusions (D-T and D-He3) which both occur at an appreciable level above 100 keV, plasma can stabilize around such high equilibrium energy (i.e. between 100 and 150 keV). The mechanical gain (Q) of such reactor increases with the internal pipe radius, up to 4.5 m. A radius of 4.5 m permits a mechanical gain (Q) of about 17 which thanks to a modern thermo-dynamical conversion would lead to convert about 21% of the thermal power issued from the D-D reactor in a net electric power of 20 GWe. The goal of the article is to create a physical model of the D-D reactor so as to estimate this one without the need of a simulator and finally to estimate the dimensions, power and yield of such D-D reactor for different net electrical powers. The difficulties of the modeling of such reactor are listed in this article and would certainly be applicable to a future D-He3 reactor, if any. 展开更多
关键词 Fusion Reactor Deuterium-Deuterium Reactor Catalyzed D-D Colliding Beams Stellarator Reactor power plant
下载PDF
Conceptual Strategy for Mitigating the Risk of Hydrogen as an Internal Hazard in Case of Severe Accidents at Nuclear Power Plant Considering Existing Risks and Uncertainties Associated with the Use of Traditional Strategies
8
作者 Arman Grigoryan 《World Journal of Nuclear Science and Technology》 CAS 2024年第3期165-177,共13页
Hydrogen challenge mitigation stands as one of the main objectives in the management of severe accidents at Nuclear Power Plants (NPPs). Key strategies for hydrogen control include atmospheric inertization and hydroge... Hydrogen challenge mitigation stands as one of the main objectives in the management of severe accidents at Nuclear Power Plants (NPPs). Key strategies for hydrogen control include atmospheric inertization and hydrogen removal with Passive Autocatalytic Recombiners (PARs) being a commonly accepted approach. However, an examination of PAR operation specificity reveals potential inefficiencies and reliability issues in certain severe accident scenarios. Moreover, during the in-vessel stage of severe accident development, in some severe accident scenarios PARs can unexpectedly become a source of hydrogen detonation. The effectiveness of hydrogen removal systems depends on various factors, including the chosen strategies, severe accident scenarios, reactor building design, and other influencing factors. Consequently, a comprehensive hydrogen mitigation strategy must effectively incorporate a combination of strategies rather than be based on one strategy, taking into consideration the probabilistic risks and uncertainties associated with the implementation of PARs or other traditional methods. In response to these considerations, within the framework of this research it has been suggested a conceptual strategy to mitigate the hydrogen challenge during the in-vessel stage of severe accident development. 展开更多
关键词 Severe Accident Management Nuclear power plant Hydrogen Risk Mitigation Risk Management Passive Autocatalytic Recombiner
下载PDF
Comparative Study of Solar PV Power Plant Dimensionnement Connected to Network Based on Monofacial and Bifacial Modules
9
作者 DJOSSOU Ayihaou Armand VODOUNNOU Edmond Claude +5 位作者 FANNOU Jean Louis Comlan DANSOU MidokpêRomuald SEMASSOU Guy Clarence HOUNGAN Comlan Aristide GUIDI Tognon Clotilde Thierno Amadou Barry 《Journal of Environmental Science and Engineering(A)》 CAS 2024年第1期36-44,共9页
This article presents the results of comparative study of two PV solar modules technologies,namely monofacial and bifacial.This study main objective is to identify conditions and parameters that make it possible to ob... This article presents the results of comparative study of two PV solar modules technologies,namely monofacial and bifacial.This study main objective is to identify conditions and parameters that make it possible to obtain better energy and economic efficiency from one or other of two technologies.The study reason lies in revival observed on bifacial module in recent years where all the major manufacturers of PV solar panels are developing them where in a few years,this technology risks being at the same price as the monofacial solar panel with better efficiency.Economic indicator used is energy levelized cost(LCOE)which is function technology type,energy productivity,annual investment and operation cost.To achieve this,a 3.685 MWc solar PV power plant was dimensioned and simulated under Matlab for a 3.5 ha site with a 2,320,740,602 FCFA budget for monofacial installation,against 1,925,188,640 FCFA for 2.73 MWc bifacial installation.The LCOE comparative analysis of two technologies calculated over a period of 25 years,showed that plant with bifacial panels is more beneficial if bifacial gain is greater than 9%.It has further been found that it is possible to gain up to 40%of invested cost if bifacial gain reaches 45%.Finally,a loss of about 10%of invested cost could be recorded if bifacial gain is less than 9%. 展开更多
关键词 Solar PV power plant SIZING Monofacial panels Bifacial panels LCOE.
下载PDF
Choice of the Best Production Prediction Model for the Zagtouli Solar Power Plant in Burkina-Faso
10
作者 Toussaint Tilado Guingane Eric Korsaga +3 位作者 Mouhamadou Falilou Ndiaye Gaston Nabayaogo Dominique Bonkoungou Zacharie Koalaga 《Engineering(科研)》 2024年第9期237-245,共9页
In this paper, we present a study on the prediction of the power produced by the 33 MWp photovoltaic power plant at Zagtouli in Burkina-Faso, as a function of climatic factors. We identified models in the literature, ... In this paper, we present a study on the prediction of the power produced by the 33 MWp photovoltaic power plant at Zagtouli in Burkina-Faso, as a function of climatic factors. We identified models in the literature, namely the Benchmark, input/output, Marion, Cristo-fri, Kroposki, Jones-Underwood and Hatziargyriou prediction models, which depend exclusively on environmental parameters. We then compared our linear model with these seven mathematical models in order to determine the most optimal prediction model. Our results show that the Hatziargyriou model is better in terms of accuracy for power prediction. 展开更多
关键词 MODEL PREDICTION power power plant PHOTOVOLTAIC Zagtouli Burkina-Faso
下载PDF
Seasonal Performance of Solar Power Plants in the Sahel Region: A Study in Senegal, West Africa
11
作者 Serigne Abdoul Aziz Niang Mamadou Simina Drame +4 位作者 Astou Sarr Mame Diarra Toure Ahmed Gueye Seydina Oumar Ndiaye Kharouna Talla 《Smart Grid and Renewable Energy》 2024年第2期79-97,共19页
The main objective of this study is to evaluate the seasonal performance of 20 MW solar power plants in Senegal. The analysis revealed notable seasonal variations in the performance of all stations. The most significa... The main objective of this study is to evaluate the seasonal performance of 20 MW solar power plants in Senegal. The analysis revealed notable seasonal variations in the performance of all stations. The most significant yields are recorded in spring, autumn and winter, with values ranging from 5 to 7.51 kWh/kWp/day for the reference yield and 4.02 to 7.58 kWh/kWp/day for the final yield. These fluctuations are associated with intense solar activity during the dry season and clear skies, indicating peak production. Conversely, minimum values are recorded during the rainy season from June to September, with a final yield of 3.86 kWh/kW/day due to dust, clouds and high temperatures. The performance ratio analysis shows seasonal dynamics throughout the year with rates ranging from 77.40% to 95.79%, reinforcing reliability and optimal utilization of installed capacity. The results of the capacity factor vary significantly, with March, April, May, and sometimes October standing out as periods of optimal performance, with 16% for Kahone, 16% for Bokhol, 18% for Malicounda and 23% for Sakal. Total losses from solar power plants show similar seasonal trends standing out for high loss levels from June to July, reaching up to 3.35 kWh/kWp/day in June. However, using solar trackers at Sakal has increased production by up to 25%, demonstrating the operational stability of this innovative technology compared with the plants fixed panel. Finally, comparing these results with international studies confirms the outstanding efficiency of Senegalese solar power plants, other installations around the world. 展开更多
关键词 Performance Study Photovoltaic power plant Season Variations Senegal
下载PDF
The Application of Intelligent Lighting in Thermal Power Plants
12
作者 Xiaozhong Kang Shuangqiang Liu +1 位作者 Guoqing Hu Haibin Huang 《Journal of Electronic Research and Application》 2024年第4期180-185,共6页
With the rapid development of electronic information technology,the Internet of Things(IoT),Internet technology,and modern communication technology,people are demanding higher standards for the building environment.Es... With the rapid development of electronic information technology,the Internet of Things(IoT),Internet technology,and modern communication technology,people are demanding higher standards for the building environment.Especially in modern large-scale buildings with high levels of industrialization,lighting systems should also be optimized accordingly.This article explores the application path of intelligent lighting in thermal power plants for reference. 展开更多
关键词 Intelligent lighting Thermal power plants Application path
下载PDF
Exploration of Construction Organization for Maintenance of Steam Turbine Equipment in Thermal Power Plants
13
作者 Zhu Yang 《Journal of Electronic Research and Application》 2024年第4期148-153,共6页
The continuous development of the power industry has had a positive impact on thermal power plants,helping them maintain a good production form.In the use of steam turbine equipment in thermal power plants,to prolong ... The continuous development of the power industry has had a positive impact on thermal power plants,helping them maintain a good production form.In the use of steam turbine equipment in thermal power plants,to prolong its lifespan and avoid safety hazards,it is necessary to pay attention to strengthening maintenance and construction organization,better implementing effective organizational work,and effectively applying steam turbine equipment to ensure the sustainable development of thermal power plants.This article discusses the concept of equipment maintenance from the perspective of steam turbine equipment in thermal power plants,analyzes the current situation of equipment maintenance,and proposes a specific construction organization to provide a reference for steam turbine equipment maintenance. 展开更多
关键词 Thermal power plant Steam turbine equipment Construction organization
下载PDF
Economic Overhaul Mode of Steam Engine Professional Equipment in Thermal Power Plant
14
作者 Rui Wang 《Journal of Electronic Research and Application》 2024年第5期46-51,共6页
To ensure that the daily production activities of thermal power plants can produce their due effect in the production and business activities,it is necessary to carry out efficient and orderly maintenance work on the ... To ensure that the daily production activities of thermal power plants can produce their due effect in the production and business activities,it is necessary to carry out efficient and orderly maintenance work on the professional equipment of steam engines.However,the maintenance work of steam engine professional equipment in thermal power plants usually uses high-cost expenditures.Therefore,how to take effective measures to reduce the cost of professional equipment maintenance in thermal power plants has become a problem that needs to be solved before such maintenance can proceed.Among them,through the application of economic maintenance equipment in thermal power plants,the actual production and operation costs can be effectively reduced.Based on this,the author will analyze the application of the model of economic maintenance of steam engine professional equipment in thermal power plants. 展开更多
关键词 Thermal power plant Turbine professional equipment maintenance Economic maintenance mode
下载PDF
Experimental Study on the Performance of ORC System Based on Ultra-Low Temperature Heat Sources
15
作者 Tianyu Zhou Liang Hao +2 位作者 Xin Xu Meng Si Lian Zhang 《Energy Engineering》 EI 2024年第1期145-168,共24页
This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.Th... This paper discussed the experimental results of the performance of an organic Rankine cycle(ORC)system with an ultra-low temperature heat source.The low boiling point working medium R134a was adopted in the system.The simulated heat source temperature(SHST)in this work was set from 39.51°C to 48.60°C by the simulated heat source module.The influence of load percentage of simulated heat source(LPSHS)between 50%and 70%,the rotary valve opening(RVO)between 20%and 100%,the resistive load between 36Ωand 180Ωor the no-load of the generator,as well as the autumn and winter ambient temperature on the system performance were studied.The results showed that the stability of the system was promoted when the generator had a resistive load.The power generation(PG)and generator speed(GS)of the system in autumn were better than in winter,but the expander pressure ratio(EPR)was lower than in winter.Keep RVO unchanged,the SHST,the mass flow rate(MFR)of the working medium,GS,and the PG of the system increased with the increasing of LPSHS for different generator resistance load values.When the RVO was 60%,LPSHS was 70%,the SHST was 44.15°C and the resistive load was 72Ω,the highest PG reached 15.11 W.Finally,a simulation formula was obtained for LPSHS,resistance load,and PG,and its correlation coefficient was between 0.9818 and 0.9901.The formula can accurately predict the PG.The experimental results showed that the standard deviation between the experimental and simulated values was below 0.0792,and the relative error was within±5%. 展开更多
关键词 ORC load percentage of simulated heat source resistive load rotary valve opening power generation
下载PDF
Real-Time Information System of Power Plant Based on B/S Computing Mode 被引量:2
16
作者 徐治皋 高正平 司风琪 《Journal of Southeast University(English Edition)》 EI CAS 2002年第1期80-83,共4页
This paper introduces the system structure and work principle of the upgraded real time information system in Wangting Power Plant, and then expounds the realization way and function features of this system on B/S co... This paper introduces the system structure and work principle of the upgraded real time information system in Wangting Power Plant, and then expounds the realization way and function features of this system on B/S computing mode. The results of field application show the new system has good capability, reliability and expandability. 展开更多
关键词 power plant real time information system B/S mode DCS
下载PDF
Integrated Automation of Power Plant Electrical System 被引量:3
17
作者 郭伟 王莉 《Journal of Southeast University(English Edition)》 EI CAS 2002年第3期221-224,共4页
Aiming at the comparatively laggard level of power plant electrical system automation, this paper analyzes the feasibility,necessity and some key points of the application of integrated automation technology to power ... Aiming at the comparatively laggard level of power plant electrical system automation, this paper analyzes the feasibility,necessity and some key points of the application of integrated automation technology to power plant electrical system. New idea using fieldbus control system technology is presented. This paper also gives the outline and detailed schemes. 展开更多
关键词 power plant electrical system fieldbus control system DCS integrated automation
下载PDF
Evaporative Cooling Applied in Thermal Power Plants:A Review of the State-ofthe-Art and Typical Case Studies 被引量:1
18
作者 Tiantian Liu Huimin Pang +7 位作者 Suoying He Bin Zhao Zhiyu Zhang Jucheng Wang Zhilan Liu Xiang Huang Yuetao Shi Ming Gao 《Fluid Dynamics & Materials Processing》 EI 2023年第9期2229-2265,共37页
A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-coo... A review is conducted about the application of the evaporative cooling technology in thermal power plants.Different case studies are considered,namely,evaporative air conditioners,evaporative cooling in direct air-cooled systems,gas turbine inlet cooling,wet cooling towers,and hybrid cooling towers with a crosswind effect.Some effort is provided to describe the advantages related to direct evaporative cooling when it is applied in thermal power plants and illustrate the research gaps,which have not been filled yet.In particular,typical case studies are intentionally used to compare the cooling performances when direct evaporative cooling is implemented in different types of cooling towers,including the natural draft wet cooling tower(NDWCT)and the pre-cooled natural draft dry cooling tower(NDDCT).It is shown that the NDWCT provides the best cooling performance in terms of power station cooling,followed by the pre-cooled NDDCT,and the NDDCT;moreover,the evaporative pre-cooling is able to enhance the cooling performance of NDDCT.Besides,on a yearly basis,better NDDCT cooling performances can be obtained by means of a spray-based pre-cooling approach with respect to wet media pre-cooling.Therefore,the use of nozzle spray is suggested for improvement in the performance of indirect/direct air-cooling systems with controlled water consumption. 展开更多
关键词 Direct evaporative cooling cooling tower cooling performance wet media nozzle spray thermal power plants
下载PDF
Energy Management System with Power Offering Strategy for a Microgrid Integrated VPP
19
作者 Yeonwoo Lee 《Computers, Materials & Continua》 SCIE EI 2023年第4期2313-2329,共17页
In the context of both the Virtual Power Plant (VPP) and microgrid(MG), the Energy Management System (EMS) is a key decision-maker forintegrating Distributed renewable Energy Resources (DERs) efficiently. TheEMS is re... In the context of both the Virtual Power Plant (VPP) and microgrid(MG), the Energy Management System (EMS) is a key decision-maker forintegrating Distributed renewable Energy Resources (DERs) efficiently. TheEMS is regarded as a strong enabler of providing the optimized schedulingcontrol in operation and management of usage of disperse DERs and RenewableEnergy reSources (RES) such as a small-size wind-turbine (WT) andphotovoltaic (PV) energies. The main objective to be pursued by the EMSis the minimization of the overall operating cost of the MG integrated VPPnetwork. However, the minimization of the power peaks is a new objective andopen issue to a well-functional EMS, along with the maximization of profitin the energy market. Thus, both objectives have to be taken into accountat the same time. Thus, this paper proposes the EMS application incorporatingpower offering strategy applying a nature-inspired algorithm such asParticle Swarm Optimization (PSO) algorithm, in order to find the optimalsolution of the objective function in the context of the overall operating cost,the coordination of DERs, and the energy losses in a MG integrated VPPnetwork. For a fair DERs coordination with minimized power fluctuationsin the power flow, the power offering strategies with an active power controland re-distribution are proposed. Simulation results show that the proposedMG integrated VPP model with PSO-based EMS employing EgalitarianreDistribution (ED) power offering strategy is most feasible option for theoverall operating cost of VPP revenue. The total operating cost of the proposedEMS with ED strategy is 40.98$ compared to 432.8$ of MGs only withoutEMS. It is concluded that each MGs in the proposed VPP model intelligentlyparticipates in energy trading market compliant with the objective function,to minimize the overall cost and the power fluctuation. 展开更多
关键词 Artificial intelligence energy management system MICROGRID nature-inspired algorithm virtual power plant
下载PDF
Solar Power Plant Network Packet-Based Anomaly Detection System for Cybersecurity
20
作者 Ju Hyeon Lee Jiho Shin Jung Taek Seo 《Computers, Materials & Continua》 SCIE EI 2023年第10期757-779,共23页
As energy-related problems continue to emerge,the need for stable energy supplies and issues regarding both environmental and safety require urgent consideration.Renewable energy is becoming increasingly important,wit... As energy-related problems continue to emerge,the need for stable energy supplies and issues regarding both environmental and safety require urgent consideration.Renewable energy is becoming increasingly important,with solar power accounting for the most significant proportion of renewables.As the scale and importance of solar energy have increased,cyber threats against solar power plants have also increased.So,we need an anomaly detection system that effectively detects cyber threats to solar power plants.However,as mentioned earlier,the existing solar power plant anomaly detection system monitors only operating information such as power generation,making it difficult to detect cyberattacks.To address this issue,in this paper,we propose a network packet-based anomaly detection system for the Programmable Logic Controller(PLC)of the inverter,an essential system of photovoltaic plants,to detect cyber threats.Cyberattacks and vulnerabilities in solar power plants were analyzed to identify cyber threats in solar power plants.The analysis shows that Denial of Service(DoS)and Manin-the-Middle(MitM)attacks are primarily carried out on inverters,aiming to disrupt solar plant operations.To develop an anomaly detection system,we performed preprocessing,such as correlation analysis and normalization for PLC network packets data and trained various machine learning-based classification models on such data.The Random Forest model showed the best performance with an accuracy of 97.36%.The proposed system can detect anomalies based on network packets,identify potential cyber threats that cannot be identified by the anomaly detection system currently in use in solar power plants,and enhance the security of solar plants. 展开更多
关键词 Renewable energy solar power plant cyber threat CYBERSECURITY anomaly detection machine learning network packet
下载PDF
上一页 1 2 250 下一页 到第