Analysis of Monosaccharide Composition of Pu-erh Tea Polysaccaride by Pre-column Derivatization HPLC 被引量:2
1
作者 郭威 周斌星 +4 位作者 罗玲 李扬 柴洁 杨超 马存强 《Agricultural Science & Technology》 CAS 2013年第4期556-558,572,共4页
[Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was ... [Objective] This study aimed to establish a pre-column derivatization HPLC method for the identification and analysis of monosaccharide composition of Pu-erh tea polysaccharide. [Method] Pu-erh tea polysaccharide was extracted using the wa- ter extraction method, further isolated and purified by DEAE cellulose-52 columns. The obtained tea polysaccharide and four components TPS1, TPS2, TPS3 and TPS, were first derived by 1-phenyl-3-methyl-5-pyrazolone (PMP), and then the PMP derivatives of monosaccharide were analyzed by high performance liquid chromatog- raphy (HPLC). [Result] Pu-erh tea polysaccharide contained eight kinds of monosac- chaddes (mannose, rhamnose, glucuronic acid, galacturonic acid, grucose, galactose, arabinose, fucose), without xylose; so it was the same with TPS1; each of TPS2, TPS3 and TPS4 contained seven monosaccharides, while no fucose. [Conclusion] This method is simplified and rapid, which can be used to determine the monosac- charide composition of Pu-erh tea polysaccharide and monosaccharide content. 展开更多
关键词 Pu-erh tea POLYSACCHARIDE HPLC pre-column derivatization
下载PDF
Determination of Sparfloxacin in Human Urine by Reversed-Phase High Performance Liquid Chromatography With Nitrous Acid and Hydroiodic Pre-Column Derivatization 被引量:1
2
作者 Li Ming DU Zhe Feng FAN +1 位作者 Jin Li QIAO Jing Ping WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第11期1007-1010,共4页
Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new met... Sparfloxacin can be oxidized by nitrous acid, then react with hydroiodic acid to form a fluorescent derivative. Based on this, a reversed-phase high performance liquid chromatographic pre-column derivatization new method is described for the determination of sparfloxacin in human urine. The linear range is 0.05 mg/L to 4.0 mg/L, the recoveries are 91.5%similar to 95.7% and the RSD is 1.2%similar to4.2%. The results showed that this method is suitable for the determination of sparfloxacin in human urine. 展开更多
关键词 SPARFLOXACIN HPLC pre-column derivatization human urine
下载PDF
Determination of 18 Kinds of Amino Acids in Fresh Tea Leaves by HPLC Coupled with Pre-column Derivatization 被引量:2
3
作者 Shangwen DONG Tengfei LIU Minghui DONG 《Asian Agricultural Research》 2018年第2期55-58,63,共5页
A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were... A rapid and accurate quantitative method of high performance liquid chromatography( HPLC) with fluorescence detector has been developed for the analysis of 18 kinds of amino acids in fresh tea leaves. The samples were minced and mixed,and extracted with ultra pure water at 90℃ for 20 min. The 6-aminoquinolyl N-hydroxy-succinimidyl carbamate( AQC) was used as pre-column derivatization reagent. Gradient HPLC separation was performed on a C_(18) column( Symmetry C_(18),3. 9 mm × 15 cm,4 μm). Good linearity between concentrations and peak areas was achieved in the concentration range of 5. 0-250 μmol/L for 18 kinds of amino acids. The method was validated by the analysis of five replicates. The 18 kinds of amino acid standards were spiked in fresh tea leaf samples and the average recovery rate was 86. 25%-109. 05% with relative standard deviations( n = 5) ranging from 6. 03% to 10. 56%. The limit of detection( LOD) for the analytes was0. 05-1. 27 μmol/L. The method was successfully applied to the analysis of the 18 kinds of amino acids in fresh tea leaves from east Dongting and west Dongting mountains in Suzhou. The results indicate that the method is simple,rapid,precise and reliable. 展开更多
关键词 Fresh tea leaves Free amino acids pre-column derivatization High performance liquid chromatography(HPLC)
下载PDF
Determination of Sulphonylurea Glimepiride in Dog Serum by RP-HPLC with Pre-column Derivatization 被引量:1
4
作者 卢来春 蒋学华 +1 位作者 周静 杨俊毅 《Journal of Chinese Pharmaceutical Sciences》 CAS 2003年第2期101-105,共5页
Aim A simple, sensitive and rapid RP HPLC method with pre column derivatization has been developed for the determination of sulphonylurea glimepiride in dog serum. Methods The sulphonylurea glimepiride was extract... Aim A simple, sensitive and rapid RP HPLC method with pre column derivatization has been developed for the determination of sulphonylurea glimepiride in dog serum. Methods The sulphonylurea glimepiride was extracted from the dog serum using dichlromethane followed by derivatization with DNBF for 20 min at 100℃. The solvent was then evaporated at 60℃ under nitrogen, and the residue was taken up in 100 μL of mobile phase consisting of acetonitrile water (75∶30, v/v). The separation was performed on a Hypersil BDS C18 column with a flow rate of 0 8 mL·min -1 , and the ultraviolet detector wavelength was set at 350 nm. Results Extraction recovery ranged from 75.9% to 83.2%, and methodological recovery was between 96.5% and 109.3%. Within day RSD ranged from 1.5% to 6.3%, and inter day RSD was between 2 9% and 14.8%. The method showed good linearity (R=0.9998). Conclusion The method was simple, convenient and sensitive. The reaction of derivatization was reproducible. 展开更多
关键词 GLIMEPIRIDE pre column derivatization DNBF serum concentration
下载PDF
A Pre-column Derivatization HPLC Method for the De-termination of Peimine and Peiminine in Bulbus Fritillar-iae
5
作者 李文彦 毕开顺 +2 位作者 乔延江 宁黎丽 罗旭 《Journal of Chinese Pharmaceutical Sciences》 CAS 1996年第4期213-218,共6页
A pre-column derivatization HPLC method for the determination of peimine(P)and peiminine(PE)in Bulbus Fritillariae has been developed. Under the derivatization conditions optimized,the calibration curve is Y1=-3.83... A pre-column derivatization HPLC method for the determination of peimine(P)and peiminine(PE)in Bulbus Fritillariae has been developed. Under the derivatization conditions optimized,the calibration curve is Y1=-3.83×103+1.33 ×105X1,r=0.998 for P and Y2=-7.86 × 102+6.33 × 104X2,r=0995 for PE,where Y is the peak area and X is the weight of the alkaloid; the average recovery is 98.0%(n=5, RSD=2.1%) for P and 101.0%(n=5,RSD=4.1%)for PE,the linear range is from 0.504 μg to 3.126μg for P and from 0.520μgto 3.328μgfor PE,respectively. Results of the determination of the two alkaloids in several samples of different Fritillaria species from various parts ofthe country are presented.The results suggest that P and PE are two major chemical constituents in bulbs of different Fritillaria species,and that the method developed is generally appli-cable to the determination of the hydroxy group on aliphatic fused ring systems without steric hin-drance. 展开更多
关键词 Peimine(P) Peiminine(PE) derivatization HPLC
下载PDF
Pre-column Derivatization-High Performance Liquid Chromatography for the Detection of Monensin in Livestock and Poultry Meat
6
作者 Jiao WANG Xiujuan WANG +2 位作者 Lingtong HU Guixia YANG Dandan HU 《Agricultural Biotechnology》 CAS 2021年第2期93-94,共2页
[Objectives]A method for the detection of monensin in poultry and livestock meat by pre-column derivatization-high performance liquid chromatography was established.[Methods]The sample was extracted with chloroform,de... [Objectives]A method for the detection of monensin in poultry and livestock meat by pre-column derivatization-high performance liquid chromatography was established.[Methods]The sample was extracted with chloroform,derivatized with trichloroacetic acid and 2,4-dinitrophenylhydrazine,and centrifuged to obtain a purified solution.A C18 chromatographic column(4.6 mm×150 mm,5μm)was used for separation with(1.5%)acetic acid water∶methanol(volume ratio)=1∶9 as the mobile phase using a DAD detector for detection,and the external standard method was adopted for peak area quantification.[Results]Monensin had good linearity in the concentration range of 5.00-200 mg/L,with the linear correlation coefficient r 2>0.999;the detection limit was 5.00 mg/kg;the relative standard deviation was smaller than 10%;and the recoveries of standard addition experiment were in the range of 75%-110%.[Conclusions]The method has the advantages of simple pretreatment operation,good derivatization effect and fast detection speed,and is suitable for detecting monensin in poultry and livestock meat. 展开更多
关键词 pre-column derivatization-high performance liquid chromatography Livestock and poultry meat MONENSIN
下载PDF
Development of Simultaneous HPLC-Fluorescence Assay of Phenol and Chlorophenols in Tap Water after Pre-Column Derivatization with 3-Chlorocarbonyl-6,7-dimethoxy-1- methyl-2(1H)-quinoxalinone 被引量:2
7
作者 Yasuhiko Higashi 《Detection》 2016年第1期16-24,共9页
Chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol and 2,4, 6-trichlorophenol) may be presented in natural waters or drinking water as a result of disinfection processes involving ch... Chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol and 2,4, 6-trichlorophenol) may be presented in natural waters or drinking water as a result of disinfection processes involving chlorination, or as contaminants derived from domestic products, industrial operations and agricultural chemicals. A previous HPLC-UV method for determination of phenol and five chlorophenols in tap water using 4-fluoro-7-nitro-2,1,3-benzoxadiaole as a UV labeling reagent shows limited sensitivity. Here, we present an improved HPLC-fluorescence detection method for simultaneous determination of phenol and the above chlorophenols in tap water after pre-column derivatization with 3-chlorocarbonyl-6,7-dimethoxy-1-methyl-2(1H)-quino- xalinone (DMEQ-COCl), using a short, narrow column (50 × 2.1 mm i.d., packed with 5 μm particles of C18 material) to improve the sensitivity. Standard samples containing the compounds are derivatized with DMEQ-COCl in borate buffer (pH 9.0) at room temperature for 3 mins. The response is linear in the concentration range of 0.01 - 0.05 to 0.5 mg/L with r2 values ≥0.9967 for all compounds. The lower limits of detection are 0.001 to 0.008 mg/L, and the coefficients of variation are less than 8.8%. The recovery values from tap water spiked with standard samples are satisfactory. The present method is suitable for examining whether or not tap water samples are contaminated with phenol and chlorophenols in excess of regulatory values. 展开更多
关键词 PHENOL CHLOROPHENOL Fluorescence derivatization 3-Chlorocarbonyl-6 7-dimethoxy-1-methyl-2(1H)-quinoxalinone
下载PDF
Simple HPLC-Fluorescence Determination of Raspberry Ketone in Fragrance Mist after Pre-Column Derivatization with 4-Hydrazino-7-nitro-2,1,3-benzoxadiazole 被引量:1
8
作者 Yasuhiko Higashi 《Journal of Analytical Sciences, Methods and Instrumentation》 2016年第2期44-49,共6页
Raspberry ketone {RK, 4-(4-hydroxyphenyl)butan-2-one} is a natural compound contained in raspberry, and is added to cosmetics for skin whitening. It is very important to measure the RK level in cosmetics for quality a... Raspberry ketone {RK, 4-(4-hydroxyphenyl)butan-2-one} is a natural compound contained in raspberry, and is added to cosmetics for skin whitening. It is very important to measure the RK level in cosmetics for quality assessment, since RK structurally resembles 4-(4-hydroxyphenyl)-2-butanol, which causes leukoderma on consumers’ skin. Here, we present a simple HPLC-fluorescence method for determination of RK in a fragrance mist by pre-column derivatization with 4-hydrazino-7-nitro-2,1,3-benzoxadiazole hydrazine (NBD-H), which reacts with the carbonyl group of RK. The NBD-RK derivative was eluted from a reversed-phase ODS column, and detected with excitation at 470 nm and emission at 550 nm. The retention time of NBD-RK derivative obtained by reaction with NBD-H at 80°C for 20 min was 10.3 min. The standard curve was linear in the range of 0.2 to 10 μg/mL, with a correlation coefficient (r<sup>2</sup>) value of 0.9980. The lower limit of detection was 0.018 μg/mL (absolute amount of 1.8 pmol). The coefficients of variation were less than 8.1%. The content of RK in fragrance mist (1.00 mL) was 1.18 ± 0.07 mg (range: 1.12 to 1.28 mg, n = 5). Recovery tests were satisfactory (83.9% ± 3.9%;range: 79.6 to 88.8%, n = 5). 展开更多
关键词 Raspberry Ketone High-Performance Liquid Chromatography 4-Hydrazino-7-nitro-2 1 3-benzoxadiazole derivatization Fluorescence
下载PDF
Enantioresolution of a Series of Chiral Benzyl Alcohols by HPLC on a Dinitrobenzoylphenylglycine Stationary Phase after Achiral Pre-Column Derivatization
9
作者 Svilen P. Simeonov Anton P. Simeonov +1 位作者 Aleksandar R. Todorov Vanya B. Kurteva 《American Journal of Analytical Chemistry》 2010年第1期1-13,共13页
High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral der... High performance liquid chromatography method for the separation of a series of chiral benzyl alcohols on N-(3,5-dinitrobenzoyl)-D-phenylglycine stationary phase (Macherey Nagel, Chiral-2) after pre-column achiral derivatization was developed. Cheap and easy available aromatic acid chlorides were used as derivatization agents. Good to excellent separations of the enantiomers were achieved in all cases in relatively short analytical runs. It was shown that the enantiorecognition depends on the substituents both in the starting alcohol and in the acid chloride. The method presents an efficient alternative to the direct analyses on polysaccharide and cyclodextrine-derived stationary phases. 展开更多
关键词 HPLC DNBPG ENANTIOSEPARATION BENZYL ALCOHOLS Achiral pre-column derivatization BENZOATES Chlorobenzoates Naphthoates
下载PDF
Simple HPLC–UV Analysis of Phenol and Its Related Compounds in Tap Water after Pre-Column Derivatization with 4-Nitrobenzoyl Chloride
10
作者 Yasuhiko Higashi 《Journal of Analytical Sciences, Methods and Instrumentation》 2017年第1期18-28,共11页
The purpose of this study is to develop an HPLC-UV (280 nm) method for simultaneous determination of phenol, five chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, and 2,4,6-trichl... The purpose of this study is to develop an HPLC-UV (280 nm) method for simultaneous determination of phenol, five chlorophenols (2-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, and 2,4,6-trichlorophenol), and three phenylphenols (2-phenylphenol, 3-phenylphenol, and 4-phenylphenol) in tap water after pre-column derivatization with 4-nitrobenzoyl chloride. Standard curves were obtained after derivatization with 4-nitrobenzoyl chloride in borate buffer (pH 8.5) at 50°C for 1 min. The nine 4-nitrobenzoyl derivatives were well separated in less than 15 min on a Cholester column. Calibration plots were linear in the range of 0.02 ~ 0.12 to 0.9 mg/L, with r2 values ≥0.9928, for all compounds. The lower limits of detection were 0.006 to 0.05 mg/L. The coefficients of variation were less than 12.0%. The recovery values from tap water spiked with a standard mixture of test compounds were satisfactory. While the levels of phenol, five chlorophenols, and three phenylphenols in tap water were below the lower limit of determination, our method is expected to be useful for monitoring and/or identifying environmental water samples that are contaminated with these compounds, i.e., for assessing compliance with the official guidelines of the World Health Organization. 展开更多
关键词 PHENOL CHLOROPHENOL Phenylphenol 4-Nitrobenzoyl CHLORIDE derivatization
下载PDF
Chemical derivatization strategies for enhancing the HPLC analytical performance of natural active triterpenoids
11
作者 Xiao-Feng Huang Ying Xue +3 位作者 Li Yong Tian-Tian Wang Pei Luo Lin-Sen Qing 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第3期295-307,共13页
Triterpenoids widely exist in nature,displaying a variety of pharmacological activities.Determining triterpenoids in different matrices,especially in biological samples holds great significance.High-performance liquid... Triterpenoids widely exist in nature,displaying a variety of pharmacological activities.Determining triterpenoids in different matrices,especially in biological samples holds great significance.High-performance liquid chromatography(HPLC)has become the predominant method for triterpenoids analysis due to its exceptional analytical performance.However,due to the structural similarities among botanical samples,achieving effective separation of each triterpenoid proves challenging,necessitating significant improvements in analytical methods.Additionally,triterpenoids are characterized by a lack of ultraviolet(UV)absorption groups and chromophores,along with low ionization efficiency in mass spectrometry.Consequently,routine HPLC analysis suffers from poor sensitivity.Chemical derivatization emerges as an indispensable technique in HPLC analysis to enhance its performance.Considering the structural characteristics of triterpenoids,various derivatization reagents such as acid chlorides,rhodamines,isocyanates,sulfonic esters,and amines have been employed for the derivatization analysis of triterpenoids.This review comprehensively summarized the research progress made in derivatization strategies for HPLC detection of triterpenoids.Moreover,the limitations and challenges encountered in previous studies are discussed,and future research directions are proposed to develop more effective derivatization methods. 展开更多
关键词 TRITERPENOID HPLC derivatization Quantification
下载PDF
Contents Variation Analysis ofγ-Amino Butyric Acid in Semen sojae praeparatum Fermentation Using Online Pre-Column Derivatization-HPLC 被引量:2
12
作者 WENG Meizhi HE Jing +5 位作者 REN Jiaxiu LIANG Yonghong CHEN Qingfeng SU Mingsheng WANG Liyuan XIE Xiaomei 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2021年第1期55-61,共7页
This paper reported the contents variation analysis ofγ-amino butyric acid(GABA)in Semen sojae praeparatum(SSP)which is a famous traditional Chinese medicine.High performance liquid chromatography(HPLC)was used and G... This paper reported the contents variation analysis ofγ-amino butyric acid(GABA)in Semen sojae praeparatum(SSP)which is a famous traditional Chinese medicine.High performance liquid chromatography(HPLC)was used and GABA was derivatized by online pre-column derivatization with o-phthalaldehyde(OPA).To validate this method,the precision,stability,repeatability and recovery were discussed.In the concentration range from 0.0125 to 0.400 mg/m L,the calibration curve for GABA was linear and the regression equation was obtained with correlation coefficient(R2)of 0.9999.Relatively high levels of GABA exist in SSP and the content changes of GABA at different time points during the fermenting process were detected.At the"yellow cladding"stage,GABA level was very low or even undetectable;the"secondary fermentation"stage witnessed a rapid increase of GABA content to 1.39-5.52 mg/g,which remained stable after 18 days of"secondary fermentation".This study demonstrated that GABA was generated at the"secondary fermentation"stage,revealing the significance and rationality of the"secondary fermentation"stage in the fermenting process of SSP.On the other hand,it suggested the downside of taking soy isoflavones as the only measurement in existing quality assessment and optimization approach for the fermenting process of SSP. 展开更多
关键词 Semen sojae praeparatum γ-amino butyric acid(GABA) "secondary fermentation"process online pre-column derivatization-high performance liquid chromatography
原文传递
DMMIC derivatization-assisted liquid chromatography-mass spectrometry method for metabolite profiling of the glutathione anabolic pathway in esophageal cancer tissues and cells 被引量:1
13
作者 Li Liu Yu-Han Lu +5 位作者 Min-Dan Wang Qun-Fei Zhao Xiu-Ping Chen Hang Yin Chen-Guo Feng Fang Zhang 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第11期1365-1373,共9页
In this work,a new pyrylium derivatization-assisted liquid chromatography-mass spectrometry(LC-MS)method was developed for metabolite profiling of the glutathione anabolic pathway(GAP)in cancer tissues and cells.The p... In this work,a new pyrylium derivatization-assisted liquid chromatography-mass spectrometry(LC-MS)method was developed for metabolite profiling of the glutathione anabolic pathway(GAP)in cancer tissues and cells.The pyrylium salt of 6,7-dimethoxy-3-methyl isochromenylium tetrafluoroborate(DMMIC)was used to label the amino group of metabolites,and a reductant of dithiothreitol(DTT)was employed to stabilize the thiol group.By combining DMMIC derivatization with LC-MS,it was feasible to quantify the 13 main metabolites on the GAP in complex biological samples,which had good linearity(R^(2)=0.99810.9999),precision(interday precision of 1.6%e19.0%and intraday precision of 1.4%e19.8%)and accuracy(83.4%-115.7%).Moreover,the recovery assessments in tissues(82.5%e107.3%)and in cells(98.1%e118.9%)with GSH-^(13)C2,^(15)N,and Cys-^(15)N demonstrated the reliability of the method in detecting tissues and cells.Following a methodological evaluation,the method was applied successfully to investigate difference in the GAP between the carcinoma and para-carcinoma tissues of esophageal squamous cell carcinoma(ESCC)and the effect of p-hydroxycinnamaldehyde(CMSP)on the GAP in KYSE150 esophageal cancer cells.The results demonstrate that the developed method provides a promising new tool to elucidate the roles of GAP in physiological and pathological processes,which can contribute to research on drugs and diseases. 展开更多
关键词 Glutathione anabolic pathway Metabolite profiling DMMIC derivatization LC-MS Esophageal squamous cell carcinoma p-Hydroxycinnamaldehyde KYSE-150cell
下载PDF
High Performance Liquid Chromatography for the Determina- tion of Metoclopramide in Pharmaceutical Preparations Using Pre-column Derivatization with Fluorescamine 被引量:1
14
作者 Tatar Ulu,Sevgi 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2012年第3期634-638,共5页
A simple, rapid and sensitive high performance liquid chromatography (HPLC) method was developed for the determination of metoclopramide in pharmaceutical preparation. The method is based on the derivatization of me... A simple, rapid and sensitive high performance liquid chromatography (HPLC) method was developed for the determination of metoclopramide in pharmaceutical preparation. The method is based on the derivatization of metoclopramide with fluorescamine. The separation was achieved on a C18 column using methanol-water (70 : 30, V/V) mobile phase. Fluorescence detector was used at the excitation and emission of 403 and 485 nm, respectively. The method was validated for linearity, limit of detection, limit of quantification, precision, accuracy, recovery, robust- ness and system suitability. The assay was linear over the concentration range of 100-2000 ng/mL. The mean recovery was 100.37%. The proposed method was successfully applied to the assay of metoclopramide in tablet preparation. The preparation was also analyzed with an official method and statistical comparison by t- and F-tests revealed that there was no significant difference between the results of the two methods with respect to mean values and standard deviations at the 95% confidence level. 展开更多
关键词 METOCLOPRAMIDE FLUORESCAMINE VALIDATION HPLC derivatization determination
原文传递
Polarity-regulated derivatization-assisted LC-MS method for amino-containing metabolites profiling in gastric cancer
15
作者 Jie Han Shilin Gong +4 位作者 Xiqing Bian Yun Qian Guilan Wang Na Li Jian-Lin Wu 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第11期1353-1364,共12页
Amino-containing compounds,including amino acids,aliphatic amines,aromatic amines,small peptides and catecholamines,are involved in various biological processes and play vital roles in multiple metabolic pathways.Prev... Amino-containing compounds,including amino acids,aliphatic amines,aromatic amines,small peptides and catecholamines,are involved in various biological processes and play vital roles in multiple metabolic pathways.Previous studies indicated that some amino-containing metabolites are significant diagnostic and prognostic biomarkers of gastric cancer.However,the discovery of precise biomarkers for the preoperative diagnosis of gastric cancer is still in an urgent need.Herein,we established a polarityregulated derivatization method coupled with liquid chromatography-mass spectrometry(LC-MS)for amino-containing metabolites profiling in the serum samples of patients with gastric cancer and healthy controls,based on our newly designed and synthesized derivatization reagent(S)-3-(1-(diisopropoxyphosphoryl)pyrrolidine-2-carboxamido)-N-hydroxysuccinimidyl ester(3-DP-NHS).Enhanced separation efficiency and detection sensitivity for amino-containing metabolites were achieved after derivatization.This method exhibited good linearity,recovery,intra-and inter-day precision and accuracy.Only 5 mL serum is needed for untargeted analysis,enabling 202 amino-containing metabolites to be detected.Statistical analysis revealed altered amino acid metabolisms in patients with gastric cancer.Furthermore,ultra high performance liquid chromatography coupled with mass spectrometry(UHPLCMS/MS)analysis quantification revealed increased serum levels of tryptamine and decreased concentrations of arginine and tryptophan in patients with gastric cancer.Receiver operating characteristic(ROC)curves indicated that an increased tryptamine/tryptophan ratio could serve as a potential biomarker for gastric cancer diagnosis.This study demostrated the possibility of using serum amino acid biomarkers for gastric cancer diagnosis,providing new avenues for the treatment of gastric cancer. 展开更多
关键词 Polarity-regulated derivatization Amino-containing metabolites Gastric cancer Liquid chromatography-mass spectrometry
下载PDF
Enantioselective assay of S(+)- and R(-)-propafenone in human urine by using RP-HPLC with pre-column chiral derivatization 被引量:3
16
作者 吴永江 马明铭 曾苏 《Journal of Zhejiang University Science》 CSCD 2004年第2期226-229,共4页
The enantioselective assay for S(+)- and R(-)-propafenone (PPF) in human urine that developed in this work involves extraction of propafenone from human urine and using S(+)-propafenone as internal standard, chiral de... The enantioselective assay for S(+)- and R(-)-propafenone (PPF) in human urine that developed in this work involves extraction of propafenone from human urine and using S(+)-propafenone as internal standard, chiral derivatization with 2,3,4,6-tetra-O-b-D-glucopranosyl isothiocyanate, and quantitation by an RP-HPLC system with UV detection (l=220 nm). A baseline separation of propafenone enantiomers was achieved on a 5-mm reverse phase ODS column, with a mixture of methanol:water:glacial acetic acid (25:12:0.02,v/v) as mobile phase. There was good linear relationship from 24.9 ng/ml to 1875.0 ng/ml for both of enantiomers. The regression equations of the standard curves based on CS-PPF (or CR-PPF ) versus ratio of AS-PPF/AS (or AR-PPF/AS ) were y=0.0032x-0.081, (r=0.999) for S-PPF and y=0.0033x+0.0039, (r=0.998) for R-PPF, respectively. The method抯 limit of detection was 12.5 ng/ml for both enantiomers, and the method抯 limit of quantitation was 28.20.52 ng/ml for S-PPF, 30.40.53 ng/ml for R-PPF (RSD<8%, n=5). The analytical method yielded average recovery of 98.9% and 100.4% for S-PPF and R-PPF, respectively. The relative standard deviation was no more than 6.11% and 6.22% for S-PPF and R-PPF, respectively. The method enabled study of metabolism of S(+)- and R(-)-propafenone in human urine. The results from 7 volunteers administered 150 mg racemic propafenone indicated that propafenone enantiomers undergo stereoselective metabolism and that in the human body, S(+)-propafenone is metabolized more extensively than R(-)- propafenone. 展开更多
关键词 Enantioselective assay PROPAFENONE Human urine Chiral derivatization High-performance liquid chroma-tography
下载PDF
Speciation of organomercury compounds by capillary electrophoresis with pre-column derivatization and on-line stacking
17
作者 Dandan Cao Yongguang Yin Bin He 《Chinese Chemical Letters》 SCIE CAS CSCD 2019年第3期650-652,共3页
Simultaneous separation and detection of three organomercury species, namely methylmercury(MeHg),ethylmercury(EtHg), and phenylmercury(PhHg), was performed by using capillary electrophoresis(CE)with UV detection. Pre-... Simultaneous separation and detection of three organomercury species, namely methylmercury(MeHg),ethylmercury(EtHg), and phenylmercury(PhHg), was performed by using capillary electrophoresis(CE)with UV detection. Pre-column derivatization with thiosalicylic acid and on-line salt-induced stacking significantly improved the detection performance. Buffer pH, ion strength, and additive were optimized for CE separation, concentration of NaCl in sample solution and injection time were optimized for on-line stacking. The limits of detection were 76.9,83.0 and 76.4 μg/L for PhHg, EtHg and MeHg, respectively. The developed method was validated by certified reference material and liquid chromatography-atomic fluorescence spectroscopy, which suggests this method could be useful in the speciation of organomercury compounds in biological samples. 展开更多
关键词 Capillary ELECTROPHORESIS Mercury SPECIATION derivatization ON-LINE STACKING
原文传递
HPLC of Amino Acids and Oligopeptides by Pre-Column Fluorescence Derivatization with 9-Acridine Formyl Chloride
18
作者 Jin Mao YOU Xin Jun FAN Qing Yu OU(Lanzhou Institute of Chemical Physics. Chinese Academy of Sciences 730000) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第10期875-878,共4页
A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, trigly... A highly sensitive HPLC method for the detection of amino acids and oligopeptides with 9-acridine formyl chloride by pre-column fluorescence derivatization has been developed. Glycine, glycylglycine, histidine, triglycine and glutathione were separated on a reversed-phase C-18 column with methanol-water-triethylamine eluent, derivatization and chromatographic conditions were optimized. The five derivatives were eluted in 28 min with a good reproducibility. Linear range of the calibration graph was 0.08-260 nmol/ml(-1). The relative standard deviations(n=6) are < 5%. Detection limits (signal-to-noise ratio=3) for the five derivatives are 20-40 fmol. 展开更多
关键词 HPLC of Amino Acids and Oligopeptides by pre-column Fluorescence derivatization with 9-Acridine Formyl Chloride
下载PDF
Liquid Chromatography Detertmination of Amino Acids by Pre-Column Fluorescence Derivatization with Acridone-N-acetyl Chloride
19
作者 Jin Mao YOU Xin Jun FAN +1 位作者 Qing Yu OU Qing Cun ZHU (Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences 730000)(Department of Chemistry, Qufu Normal University, Qufu, Shandong 273165) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第7期657-660,共4页
A sensitive liquid chromatographic mcthod for the detection of andno acids with precolumn fluorescence derivatization with acridone-N-acetyl chloride has been developed. Andno acid derivatives were eluted in 4o ndn wi... A sensitive liquid chromatographic mcthod for the detection of andno acids with precolumn fluorescence derivatization with acridone-N-acetyl chloride has been developed. Andno acid derivatives were eluted in 4o ndn with good reproducibility. The reIative standard deviations (n=6) at an analytical concentration of 50 pmol are < 4%. The method described is also suitable for the analysis of andno acids in different biological samples. 展开更多
关键词 Liquid chromatography Acridone-N-acetyl Chloride Amino acids derivatization
下载PDF
HPLC Determination of Amino Acids by Pre-Column Fluorescence Derivatization with Carbazole-9-yl-Acetyl Chloride
20
作者 Jin Mao YOU Xing Jun FAN +1 位作者 Qing Yu OU Qing Cun ZHU(Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences 730000)(Department of Chemistry, Qufu Normal University, Qufu, Shandong 273165) 《Chinese Chemical Letters》 SCIE CAS CSCD 1998年第3期281-285,共5页
A sensitive HPLC method for the detection of amino acids with pre-column fluorescence derivatization with carbazole-9-yl-acetyl chloride has been developed. This method, in conjunction with a multi-gradient program, o... A sensitive HPLC method for the detection of amino acids with pre-column fluorescence derivatization with carbazole-9-yl-acetyl chloride has been developed. This method, in conjunction with a multi-gradient program, offers baseline resolution of the common CRAC-amino acids from a linear acetonitrile gradient. Separation of amino acid derivatives was obtained on a reversed-phase C-18 column. Derivatization and chromatographic conditions were optimized. Amino acid derivatives were eluted in 40 min with good reproducibility. The relative standard deviations (n=6) at an analytical concentration of 100 pmol are < 4%. The methods described are also suitable for the analysis of amino acids in different biological samples. 展开更多
关键词 liquid chromatography amino acids fluorescence derivatization carbazole-9-yl-acetyl chloride
全文增补中