Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirm...Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation.展开更多
With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly pro...With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.展开更多
Aiming at various faults in an air conditioning system,the fault characteristics are analyzed.The influence of the faults on the energy consumption and thermal comfort of the system are also discussed.The simulation r...Aiming at various faults in an air conditioning system,the fault characteristics are analyzed.The influence of the faults on the energy consumption and thermal comfort of the system are also discussed.The simulation results show that the measurement faults of the supply air temperature can lead to the increase in energy consumption.According to the fault characteristics,a data-driven method based on a neural network is presented to detect and diagnose the faults of air handling units.First,the historical data are selected to train the neural network so that it can recognize and predict the operation of the system.Then,the faults can be diagnosed by calculating the relative errors denoting the difference between the measuring values and the prediction outputs.Finally,the fault diagnosis strategy using the neural network is validated by using a simulator based on the TRNSYS platform.The results show that the neural network can diagnose different faults of the temperature,the flow rate and the pressure sensors in the air conditioning system.展开更多
A novel fault diagnosis method for sensors in air handling unit(AHU) using wavelet energy entropy was presented. Instead of directly comparing the numerous data under noise conditiom, the wavelet energy entropy resi...A novel fault diagnosis method for sensors in air handling unit(AHU) using wavelet energy entropy was presented. Instead of directly comparing the numerous data under noise conditiom, the wavelet energy entropy residual was compared in the proposed method. Three.level wavelet analysis was used to decompose the measurement data under both fault-free and faulty operation conditions. The concept of Shannon entropy was referred to define wavelet energy entropy of the wavelet coefficients. The sensor faults were diagnosed by comparing the deviation of the wavelet energy entropy of the measured signal and the estimated one with the preset threshold. Testing results showed that the wavelet energy entropy was sensitive to diagnose the biased faults. The wavelet energy entropy residuals exceed the threshold significantly when faults occur. In addition, the severer the faults were, the larger the residuals would be. The results prove that the proposed method is feasible and effective for the fault detection and diagnosis of the sensors.展开更多
The Northeast United States spring is indicative of major meteorological and biological change though the seasonal boundaries are difficult to define and may even be changing with global climate warming. This research...The Northeast United States spring is indicative of major meteorological and biological change though the seasonal boundaries are difficult to define and may even be changing with global climate warming. This research aims to obtain a synoptic meteorological definition of the spring season through an assessment of air mass frequency over the past 60 years. The validity of recent speculations that the onset and termination of spring have changed in recent decades with global change is also examined. The Spatial Synoptic Classification is utilized to define daily air masses over the region. Annual and seasonal baseline frequencies are identified and their differences are acquired to characterize the season. Seasonal frequency departures of the early and late segments of the period of record are calculated and examined for practical and statistical significance. The daily boundaries of early and late spring are also isolated and assessed across the period of record to identify important changes in the season’s initiation and termination through time. Results indicate that the Northeast spring season is dominated by dry air masses, mainly the Dry Moderate and Dry Polar types. Prior to 1975, more polar air masses are detected while after 1975 more moderate and tropical types are identified. Late spring is characterized by increased variability in all moist air mass frequencies. These findings indicate that, from a synoptic perspective, the season is dry through time but modern springs are also warmer than those of past decades and the initiation of the season is likely arriving earlier. The end of the season represents more variable day-to-day air mass conditions in modern times than detected in past decades.展开更多
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy...The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.展开更多
Baosteel' s No. 8 air separation unit(ASU) is the first domestically-integrated 60 000 m^3/h ASU. This paper describes the mechanical equipment, the design and the configuration characteristics of this unit. The po...Baosteel' s No. 8 air separation unit(ASU) is the first domestically-integrated 60 000 m^3/h ASU. This paper describes the mechanical equipment, the design and the configuration characteristics of this unit. The potential failure modes of the mechanical devices are deduced via analyses on the failure history of similar devices in other ASUs. Finally, this paper also brings up suggestions on daily maintenance, overhaul and purchases of spare parts.展开更多
Baosteel's 60000 m……3/h air separation unit (ASU), the first domestically-integrated unit of its class, is a milestone in the Chinese air separation industry. In this paper,the process characteristics of the unit...Baosteel's 60000 m……3/h air separation unit (ASU), the first domestically-integrated unit of its class, is a milestone in the Chinese air separation industry. In this paper,the process characteristics of the unit and the application of the original techniques are expatiated. Some difficulties in the process design, the risk control, the quality control, the control system integration and the system commissioning are analyzed and appraised. The mode of the project integration and innovation, the cooperation among industries and the user-orientated project management mode are introduced. Finally,the successful experiences in innovation are summarized with the focus on the integration of the project.展开更多
This paper introduces the process flow, technical parameters and relevant features of Baosteel's No. 8 air separation unit (ASU) with a capacity of 60000m^3/h. It summarizes the commissioning work, which includes t...This paper introduces the process flow, technical parameters and relevant features of Baosteel's No. 8 air separation unit (ASU) with a capacity of 60000m^3/h. It summarizes the commissioning work, which includes the adjustment of the air compressor,the system's naked cooling,the precooling system and the operation adjustment. It also provides detailed analyses on some failures which occurred in the commissioning. Through the modification of the design and the interlocks, the tripping probability of the air compressor was greatly reduced. Through the heating of the system and the control of the water cooler's nitrogen flow,the overproof content of carbon dioxide and fluctuation of oxygen flow were avoided. Nitrogen-block in the argon system was eliminated by the precise control of the argon rectification flow and argon content. All these solutions have been proved to be effective by practice.展开更多
The first domestically-integrated large-scale air separation unit (ASU) with a capacity of 60 000 m^3/h was successfully built and put into operation at Baosteel. Compared with the electrical design of the imported ...The first domestically-integrated large-scale air separation unit (ASU) with a capacity of 60 000 m^3/h was successfully built and put into operation at Baosteel. Compared with the electrical design of the imported equipment of the same type,this ASU has an electrical protection interlink that is independent from the distribution control system (DCS). With the design idea of simplicity, the ASU features a simplified configuration and an audio alarm system for electrical failures. It helps reduce the failure rate of the electrical equipment and detect failures quickly and accurately. It will effectively enhance safe and stabilized production. The ASU can not only reduce the cost of investment, but also ensure a smooth and stable running of the whole electrical equipment. This study focuses on the experience and understanding of the unit design and commissioning.展开更多
Based on the practice of Baosteel' s 60000 m3/h air separation unit (ASU) ,which is the first domestically- integrated unit of such a scale, this paper studies the principles of type selection of the distribution c...Based on the practice of Baosteel' s 60000 m3/h air separation unit (ASU) ,which is the first domestically- integrated unit of such a scale, this paper studies the principles of type selection of the distribution control system (DCS). It discusses the design of the unit's control system,which involves a compressor system,a purification system (molecular sieving), a turbo expansion system and an air separation system. The final part of the paper discusses the maintenance and future development of the ASU control system at Baosteel.展开更多
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu...DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.展开更多
The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, an...The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, and as such only works for volatile contaminants. Air quality samples around the thermal desorption Unit (TDU), used for the treatment of hydrocarbon impacted soils were taken at six (6) different sampling points (Stations). The sampling points were 100 m apart beginning from 0 m which was the closest to the TDU. The results showed that the mean values of SO<sub>2</sub> were 0.01 ppm for both the dry and wet seasons and it is within the FMEnv limit of 0.01. The mean concentration of NO<sub>2</sub> in the dry season was 0.25 μg/m<sup>3</sup> and in the wet season it was 0.18 μg/m<sup>3</sup>, which were above the FMEnv limit of 0.06 μg/m<sup>3</sup>. It is a strong oxidizing agent that reacts with air/water to form corrosive nitric acid, as well as toxic organic nitrates. The mean concentration of CO<sub>2</sub> recorded in the dry season was 11.52 ppm and that for the wet season was 10.53 ppm, which were slightly above the FMEnv limit of 10.00 ppm. The levels of SPM 2.5 recorded in the study show a concentration of 132.07 μg/m<sup>3</sup> in the dry season and 95.93 μg/m<sup>3</sup> in the wet season while those for SPM 10 had 102.17 μg/m<sup>3</sup> in the dry season and 91.33 μg/m<sup>3</sup> in the wet season. The level of the VOC recorded across the study area was significantly low (0.11 μg/m<sup>3</sup>). The mean H<sub>2</sub>S concentration recorded across the study area was low (0.01 μg/m<sup>3</sup>). Several health risks have been associated with SPM. Inhaling SPM affects respiratory and cardiovascular systems in both children and adults. Fine SPM (such as PM 2.5 particulate) can penetrate into the lungs and blood streams when inhaled, resulting to respiratory problems, heart attack, lung cancer and even death, while exposure to low levels of H<sub>2</sub>S can induce headaches as well as breathing difficulties in some asthmatic patients.展开更多
Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on f...Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on four types of agar media and incubated at 25℃. Forty-five fungal species representing 23 genera were isolated and identified. The most prevalent genera recorded were Cladosporium, Aspergillus, Penicillium and Fusarium. The total colony forming units of airborne fungi recovered in I.C.U. and O.R. ranged between 31.13-49.61 colonies/m3 on the four types of media usedl The fungal total catch of the dust samples collected from the air conditioning system filters in I.C.U. and O.R. were ranged from 65.5-170 colonies/mg dust. Since, the interest to replace synthetic xenobiotics by natural compounds with low environmental persistence and biodegradable to control such airborne fungal contaminants is needed. In this respect, essential oils showed to possess a broad spectrum of antifungal activity. Fungal static ability of six oils was tested on 30 different fungal isolates. Vapors of common thyme oil exhibited the strongest inhibitory effects on the tested isolates, whereas the headspace vapors of blue gum and ginger had no inhibitory effects on the tested fungal isolates. These data revealed that the air conditioning systems may be an important source of contamination in I.C.U. and O.R. of Assiut university hospitals. Thus, patients may be in risk of being exposed to contaminated atmospheric air by opportunistic fungi and the use of essential oils as an alternative option to control hospital wards from fungal contaminants needs further studies.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
基金supported by the National Key R&D Program of China(2021YFB3301100)Beijing University of Chemical Technology Interdisciplinary Program(XK2023-07).
文摘Corrosion leakages often occur in the air cooler of a hydrocracking unit,with the failure sites mainly located in the entrance area of the tubes.An analysis of the macroscopic morphology and corrosion products confirmed that the damage was caused by erosion-corrosion(E-C).Numerical and experimental methods were applied to investigate the E-C mechanism in the air cooler.Computational fluid dynamics(CFD)was used to calculate the hydrodynamic parameters of the air cooler.The results showed that there was a biased flow in the air cooler,which led to a significant increase in velocity,turbulent kinetic energy and wall shear within 0.2 m of the tube entrance.A visualization experiment was then performed to determine the principles of migration and transformation of multiphase flow in the air cooler tubes.Various flow patterns(pure droplet flow,mist flow,and annular flow)and their evolutionary processes were clearly depicted experimentally.The initiation mechanism and processes leading to the development of E-C in the air cooler were also determined.This study provided a comprehensive explanation for the E-C failures that occur in air coolers during operation.
基金Research Project of China Ship Development and Design Center,Wuhan,China。
文摘With the development of the technology of the Internet of Things,more and more operational data can be collected from air conditioning systems.Unfortunately,the most of existing air conditioning controllers mainly provide controlling functions more than storing,processing or computing the measured data.This study develops an online fault detection configuration on the equipment side of air conditioning systems to realize these functions.Modbus communication is served to collect real-time operational data.The calculating programs are embedded to identify whether the measured signals exceed their limits or not,and to detect if sensor reading is frozen and other faults in relation to the operational performance are generated or not.The online fault detection configuration is tested on an actual variable-air-volume(VAV)air handling unit(AHU).The results show that the time ratio of fault detection exceeds 95.00%,which means that the configuration exhibits an acceptable fault detection effect.
文摘Aiming at various faults in an air conditioning system,the fault characteristics are analyzed.The influence of the faults on the energy consumption and thermal comfort of the system are also discussed.The simulation results show that the measurement faults of the supply air temperature can lead to the increase in energy consumption.According to the fault characteristics,a data-driven method based on a neural network is presented to detect and diagnose the faults of air handling units.First,the historical data are selected to train the neural network so that it can recognize and predict the operation of the system.Then,the faults can be diagnosed by calculating the relative errors denoting the difference between the measuring values and the prediction outputs.Finally,the fault diagnosis strategy using the neural network is validated by using a simulator based on the TRNSYS platform.The results show that the neural network can diagnose different faults of the temperature,the flow rate and the pressure sensors in the air conditioning system.
基金National Natural Science Foundation of China(No.31101085)
文摘A novel fault diagnosis method for sensors in air handling unit(AHU) using wavelet energy entropy was presented. Instead of directly comparing the numerous data under noise conditiom, the wavelet energy entropy residual was compared in the proposed method. Three.level wavelet analysis was used to decompose the measurement data under both fault-free and faulty operation conditions. The concept of Shannon entropy was referred to define wavelet energy entropy of the wavelet coefficients. The sensor faults were diagnosed by comparing the deviation of the wavelet energy entropy of the measured signal and the estimated one with the preset threshold. Testing results showed that the wavelet energy entropy was sensitive to diagnose the biased faults. The wavelet energy entropy residuals exceed the threshold significantly when faults occur. In addition, the severer the faults were, the larger the residuals would be. The results prove that the proposed method is feasible and effective for the fault detection and diagnosis of the sensors.
文摘The Northeast United States spring is indicative of major meteorological and biological change though the seasonal boundaries are difficult to define and may even be changing with global climate warming. This research aims to obtain a synoptic meteorological definition of the spring season through an assessment of air mass frequency over the past 60 years. The validity of recent speculations that the onset and termination of spring have changed in recent decades with global change is also examined. The Spatial Synoptic Classification is utilized to define daily air masses over the region. Annual and seasonal baseline frequencies are identified and their differences are acquired to characterize the season. Seasonal frequency departures of the early and late segments of the period of record are calculated and examined for practical and statistical significance. The daily boundaries of early and late spring are also isolated and assessed across the period of record to identify important changes in the season’s initiation and termination through time. Results indicate that the Northeast spring season is dominated by dry air masses, mainly the Dry Moderate and Dry Polar types. Prior to 1975, more polar air masses are detected while after 1975 more moderate and tropical types are identified. Late spring is characterized by increased variability in all moist air mass frequencies. These findings indicate that, from a synoptic perspective, the season is dry through time but modern springs are also warmer than those of past decades and the initiation of the season is likely arriving earlier. The end of the season represents more variable day-to-day air mass conditions in modern times than detected in past decades.
基金Xi'an Polytechnic University Graduate Innovational Foundation(chx080608)
文摘The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.
文摘Baosteel' s No. 8 air separation unit(ASU) is the first domestically-integrated 60 000 m^3/h ASU. This paper describes the mechanical equipment, the design and the configuration characteristics of this unit. The potential failure modes of the mechanical devices are deduced via analyses on the failure history of similar devices in other ASUs. Finally, this paper also brings up suggestions on daily maintenance, overhaul and purchases of spare parts.
文摘Baosteel's 60000 m……3/h air separation unit (ASU), the first domestically-integrated unit of its class, is a milestone in the Chinese air separation industry. In this paper,the process characteristics of the unit and the application of the original techniques are expatiated. Some difficulties in the process design, the risk control, the quality control, the control system integration and the system commissioning are analyzed and appraised. The mode of the project integration and innovation, the cooperation among industries and the user-orientated project management mode are introduced. Finally,the successful experiences in innovation are summarized with the focus on the integration of the project.
文摘This paper introduces the process flow, technical parameters and relevant features of Baosteel's No. 8 air separation unit (ASU) with a capacity of 60000m^3/h. It summarizes the commissioning work, which includes the adjustment of the air compressor,the system's naked cooling,the precooling system and the operation adjustment. It also provides detailed analyses on some failures which occurred in the commissioning. Through the modification of the design and the interlocks, the tripping probability of the air compressor was greatly reduced. Through the heating of the system and the control of the water cooler's nitrogen flow,the overproof content of carbon dioxide and fluctuation of oxygen flow were avoided. Nitrogen-block in the argon system was eliminated by the precise control of the argon rectification flow and argon content. All these solutions have been proved to be effective by practice.
文摘The first domestically-integrated large-scale air separation unit (ASU) with a capacity of 60 000 m^3/h was successfully built and put into operation at Baosteel. Compared with the electrical design of the imported equipment of the same type,this ASU has an electrical protection interlink that is independent from the distribution control system (DCS). With the design idea of simplicity, the ASU features a simplified configuration and an audio alarm system for electrical failures. It helps reduce the failure rate of the electrical equipment and detect failures quickly and accurately. It will effectively enhance safe and stabilized production. The ASU can not only reduce the cost of investment, but also ensure a smooth and stable running of the whole electrical equipment. This study focuses on the experience and understanding of the unit design and commissioning.
文摘Based on the practice of Baosteel' s 60000 m3/h air separation unit (ASU) ,which is the first domestically- integrated unit of such a scale, this paper studies the principles of type selection of the distribution control system (DCS). It discusses the design of the unit's control system,which involves a compressor system,a purification system (molecular sieving), a turbo expansion system and an air separation system. The final part of the paper discusses the maintenance and future development of the ASU control system at Baosteel.
基金Supported by Program for Changjiang Scholars and Innovative Research Team in University,Ministry of Education of China(PCSIRT)
文摘DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
文摘The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, and as such only works for volatile contaminants. Air quality samples around the thermal desorption Unit (TDU), used for the treatment of hydrocarbon impacted soils were taken at six (6) different sampling points (Stations). The sampling points were 100 m apart beginning from 0 m which was the closest to the TDU. The results showed that the mean values of SO<sub>2</sub> were 0.01 ppm for both the dry and wet seasons and it is within the FMEnv limit of 0.01. The mean concentration of NO<sub>2</sub> in the dry season was 0.25 μg/m<sup>3</sup> and in the wet season it was 0.18 μg/m<sup>3</sup>, which were above the FMEnv limit of 0.06 μg/m<sup>3</sup>. It is a strong oxidizing agent that reacts with air/water to form corrosive nitric acid, as well as toxic organic nitrates. The mean concentration of CO<sub>2</sub> recorded in the dry season was 11.52 ppm and that for the wet season was 10.53 ppm, which were slightly above the FMEnv limit of 10.00 ppm. The levels of SPM 2.5 recorded in the study show a concentration of 132.07 μg/m<sup>3</sup> in the dry season and 95.93 μg/m<sup>3</sup> in the wet season while those for SPM 10 had 102.17 μg/m<sup>3</sup> in the dry season and 91.33 μg/m<sup>3</sup> in the wet season. The level of the VOC recorded across the study area was significantly low (0.11 μg/m<sup>3</sup>). The mean H<sub>2</sub>S concentration recorded across the study area was low (0.01 μg/m<sup>3</sup>). Several health risks have been associated with SPM. Inhaling SPM affects respiratory and cardiovascular systems in both children and adults. Fine SPM (such as PM 2.5 particulate) can penetrate into the lungs and blood streams when inhaled, resulting to respiratory problems, heart attack, lung cancer and even death, while exposure to low levels of H<sub>2</sub>S can induce headaches as well as breathing difficulties in some asthmatic patients.
文摘Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on four types of agar media and incubated at 25℃. Forty-five fungal species representing 23 genera were isolated and identified. The most prevalent genera recorded were Cladosporium, Aspergillus, Penicillium and Fusarium. The total colony forming units of airborne fungi recovered in I.C.U. and O.R. ranged between 31.13-49.61 colonies/m3 on the four types of media usedl The fungal total catch of the dust samples collected from the air conditioning system filters in I.C.U. and O.R. were ranged from 65.5-170 colonies/mg dust. Since, the interest to replace synthetic xenobiotics by natural compounds with low environmental persistence and biodegradable to control such airborne fungal contaminants is needed. In this respect, essential oils showed to possess a broad spectrum of antifungal activity. Fungal static ability of six oils was tested on 30 different fungal isolates. Vapors of common thyme oil exhibited the strongest inhibitory effects on the tested isolates, whereas the headspace vapors of blue gum and ginger had no inhibitory effects on the tested fungal isolates. These data revealed that the air conditioning systems may be an important source of contamination in I.C.U. and O.R. of Assiut university hospitals. Thus, patients may be in risk of being exposed to contaminated atmospheric air by opportunistic fungi and the use of essential oils as an alternative option to control hospital wards from fungal contaminants needs further studies.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.