期刊文献+
共找到7,450篇文章
< 1 2 250 >
每页显示 20 50 100
Estimation-free spatial-domain image reconstruction of structured illumination microscopy 被引量:1
1
作者 Xiaoyan Li Shijie Tu +4 位作者 Yile Sun Yubing Han Xiang Hao Cuifang kuang Xu Liu 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第2期45-58,共14页
Structured illumination microscopy(SIM)achieves super-resolution(SR)by modulating the high-frequency information of the sample into the passband of the optical system and subsequent image reconstruction.The traditiona... Structured illumination microscopy(SIM)achieves super-resolution(SR)by modulating the high-frequency information of the sample into the passband of the optical system and subsequent image reconstruction.The traditional Wiener-filtering-based reconstruction algorithm operates in the Fourier domain,it requires prior knowledge of the sinusoidal illumination patterns which makes the time-consuming procedure of parameter estimation to raw datasets necessary,besides,the parameter estimation is sensitive to noise or aberration-induced pattern distortion which leads to reconstruction artifacts.Here,we propose a spatial-domain image reconstruction method that does not require parameter estimation but calculates patterns from raw datasets,and a reconstructed image can be obtained just by calculating the spatial covariance of differential calculated patterns and differential filtered datasets(the notch filtering operation is performed to the raw datasets for attenuating and compensating the optical transfer function(OTF)).Experiments on reconstructing raw datasets including nonbiological,biological,and simulated samples demonstrate that our method has SR capability,high reconstruction speed,and high robustness to aberration and noise. 展开更多
关键词 Structured illumination microscopy image reconstruction spatial domain digital micromirror device(DMD)
下载PDF
Numerical Simulation of Super-Resolution Structured Illumination Microscopy (SIM) Using Heintzmann-Cremer Algorithm with Non-Continuous Spatial Frequency Support
2
作者 Mesfin Woldeyohannes William McCray Weiguo Yang 《Optics and Photonics Journal》 2024年第5期75-90,共16页
We report a comprehensive numerical study of super resolution (SR) structured illumination microscopy (SIM) utilizing the classic Heintzmann-Cremer SIM process and algorithm. In particular, we investigated the impact ... We report a comprehensive numerical study of super resolution (SR) structured illumination microscopy (SIM) utilizing the classic Heintzmann-Cremer SIM process and algorithm. In particular, we investigated the impact of the diffraction limit of the underlying imaging system on the optimal SIM grating frequency that can be used to obtain the highest SR enhancement with non-continuous spatial frequency support. Besides confirming the previous theoretical and experimental work that SR-SIM can achieve an enhancement close to 3 times the diffraction limit with grating pattern illuminations, we also observe and report a series of more subtle effects of SR-SIM with non-continuous spatial frequency support. Our simulations show that when the SIM grating frequency exceeds twice that of the diffraction limit, the higher SIM grating frequency can help achieve a higher SR enhancement for the underlying imaging systems whose diffraction limit is low, though this enhancement is obtained at the cost of losing resolution at some lower resolution targets. Our simulations also show that, for underlying imaging systems with high diffraction limits, however, SR-SIM grating frequencies above twice the diffraction limits tend to bring no significant extra enhancement. Furthermore, we observed that there exists a limit grating frequency above which the SR enhancement effect is lost, and the reconstructed images essentially have the same resolution as the one obtained directly from the underlying imaging system without using the SIM process. 展开更多
关键词 Structured illumination Microscopy Super Resolution Imaging Spatial Frequency Support Diffraction Limit
下载PDF
Speckle structured illumination endoscopy with enhanced resolution at wide field of view and depth of field 被引量:3
3
作者 Elizabeth Abraham Junxiao Zhou Zhaowei Liu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2023年第7期10-17,共8页
Structured illumination microscopy(SIM)is one of the most widely applied wide field super resolution imaging techniques with high temporal resolution and low phototoxicity.The spatial resolution of SIM is typically li... Structured illumination microscopy(SIM)is one of the most widely applied wide field super resolution imaging techniques with high temporal resolution and low phototoxicity.The spatial resolution of SIM is typically limited to two times of the diffraction limit and the depth of field is small.In this work,we propose and experimentally demonstrate a low cost,easy to implement,novel technique called speckle structured illumination endoscopy(SSIE)to enhance the resolution of a wide field endoscope with large depth of field.Here,speckle patterns are used to excite objects on the sample which is then followed by a blind-SIM algorithm for super resolution image reconstruction.Our approach is insensitive to the 3D morphology of the specimen,or the deformation of illuminations used.It greatly simplifies the experimental setup as there are no calibration protocols and no stringent control of illumination patterns nor focusing optics.We demonstrate that the SSIE can enhance the resolution 2–4.5 times that of a standard white light endoscopic(WLE)system.The SSIE presents a unique route to super resolution in endoscopic imaging at wide field of view and depth of field,which might be beneficial to the practice of clinical endoscopy. 展开更多
关键词 speckle structured illumination endoscopy wide field of view large depth of field easy-to-implement low cost
下载PDF
Complex-amplitude Fourier single-pixel imaging via coherent structured illumination 被引量:1
4
作者 侯红云 赵亚楠 +4 位作者 韩佳成 曹德忠 张素恒 刘宏超 梁宝来 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第6期236-241,共6页
We propose a method of complex-amplitude Fourier single-pixel imaging(CFSI)with coherent structured illumination to acquire both the amplitude and phase of an object.In the proposed method,an object is illustrated by ... We propose a method of complex-amplitude Fourier single-pixel imaging(CFSI)with coherent structured illumination to acquire both the amplitude and phase of an object.In the proposed method,an object is illustrated by a series of coherent structured light fields,which are generated by a phase-only spatial light modulator,the complex Fourier spectrum of the object can be acquired sequentially by a single-pixel photodetector.Then the desired complex-amplitude image can be retrieved directly by applying an inverse Fourier transform.We experimentally implemented this CFSI with several different types of objects.The experimental results show that the proposed method provides a promising complex-amplitude imaging approach with high quality and a stable configuration.Thus,it might find broad applications in optical metrology and biomedical science. 展开更多
关键词 complex-amplitude imaging single-pixel imaging Fourier basis scan coherent structured illumination
下载PDF
Comparison of point detection and area detection for point-scanning structured illumination microscopy
5
作者 Wenshuai Wu Jiajie Chen +6 位作者 Meiting Wang Lei Wang Xiaomin Zheng Jia Li Junle Qu Bruce Zhi Gao Yonghong Shao 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第4期134-149,共16页
Structured illumination microscopy(SIM)is suitable for biological samples because of its relatively low-peak illumination intensity requirement and high imaging speed.The system resolution is affected by two typical d... Structured illumination microscopy(SIM)is suitable for biological samples because of its relatively low-peak illumination intensity requirement and high imaging speed.The system resolution is affected by two typical detection modes:Point detection and area detection.However,a systematic analysis of the imaging performance of the different detection modes of the system has rarely been conducted.In this study,we compared laser point scanning point detection(PS-PD)and point scanning area detection(PS-AD)imaging in nonconfocal microscopy through theoretical analysis and simulated imaging.The results revealed that the imaging resolutions of PSPD and PS-AD depend on excitation and emission point spread functions(PSFs),respectively.Especially,we combined the second harmonic generation(SHG)of point detection(P-SHG)and area detection(A-SHG)with SIM to realize a nonlinear SIM-imaging technique that improves the imaging resolution.Moreover,we analytically and experimentally compared the nonlinear SIM performance of P-SHG with that of A-SHG. 展开更多
关键词 SUPER-RESOLUTION structured illumination microscopy second harmonic generation
下载PDF
Compact and robust dual-color linearly polarized illumination source for three-photon fluorescence imaging
6
作者 Jiazheng Song Yanyan Zhang Yuanshan Liu 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2023年第5期69-76,共8页
The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized li... The miniaturized femtosecond laser in near infrared-Ⅱregion is the core equipment of threephoton microscopy.In this paper,we design a compact and robust illumination source that emits dual-color linearly polarized light for three-photon microscopy.Based on an all-polarizationmaintaining passive mode-locked fiber laser,we shift the center wavelength of the pulses to the 1.7m band utilizing cascade Raman effect,thereby generate dual-wavelength pulses.To enhance clarity,the two wavelengths are separated through the graded-index multimode fiber.Then we obtain the dual-pulse sequences with 1639.4 nm and 1683.7 nm wavelengths,920 fs pulse duration,and 23.75 MHz pulse repetition rate.The average power of the signal is 53.64mW,corresponding to a single pulse energy of 2.25 nJ.This illumination source can be further amplified and compressed for three-photon fluorescence imaging,especially dual-color three-photon fluorescence imaging,making it an ideal option for biomedical applications. 展开更多
关键词 Three-photon fluorescence imaging illumination source dual-wavelength femtosecond pulse cascaded Raman effect graded-index multimodefiber.
下载PDF
Radial Basis Approximations Based BEMD for Enhancement of Non-Uniform Illumination Images
7
作者 Anchal Tyagi Salem Alelyani +3 位作者 Sapna Katiyar Mohammad Rashid Hussain Rijwan Khan Mohammed Saleh Alsaqer 《Computer Systems Science & Engineering》 SCIE EI 2023年第5期1423-1438,共16页
An image can be degraded due to many environmental factors like foggy or hazy weather,low light conditions,extra light conditions etc.Image captured under the poor light conditions is generally known as non-uniform il... An image can be degraded due to many environmental factors like foggy or hazy weather,low light conditions,extra light conditions etc.Image captured under the poor light conditions is generally known as non-uniform illumination image.Non-uniform illumination hides some important information present in an image during the image capture Also,it degrades the visual quality of image which generates the need for enhancement of such images.Various techniques have been present in literature for the enhancement of such type of images.In this paper,a novel architecture has been proposed for enhancement of poor illumination images which uses radial basis approximations based BEMD(Bi-dimensional Empirical Mode Decomposition).The enhancement algorithm is applied on intensity and saturation components of image.Firstly,intensity component has been decomposed into various bi-dimensional intrinsic mode function and residue by using sifting algorithm.Secondly,some linear transformations techniques have been applied on various bidimensional intrinsic modes obtained and residue and further on joining the transformed modes with residue,enhanced intensity component is obtained.Saturation part of an image is then enhanced in accordance to the enhanced intensity component.Final enhanced image can be obtained by joining the hue,enhanced intensity and enhanced saturation parts of the given image.The proposed algorithm will not only give the visual pleasant image but maintains the naturalness of image also. 展开更多
关键词 Non-uniform illumination BEMD intrinsic modes radial basis approximation linear transformation
下载PDF
Efficacy and safety of Usights UC100 illuminated microcatheter in microcatheter-assisted trabeculotomy
8
作者 Shuo Yu Ke Xu Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期272-277,共6页
AIM:To evaluate the efficacy and safety of Usights UC100 illuminated microcatheter in microcatheter-assisted trabeculotomy(MAT).METHODS:Totally 10 eyes of 10 patients with primary open angle glaucoma(POAG)who underwen... AIM:To evaluate the efficacy and safety of Usights UC100 illuminated microcatheter in microcatheter-assisted trabeculotomy(MAT).METHODS:Totally 10 eyes of 10 patients with primary open angle glaucoma(POAG)who underwent MAT facilitated by Usights UC100(5 eyes)or iTrack(5 eyes)were reviewed.The success of this surgery was defined as intraocular pressure(IOP)<22 mm Hg with>30%reduction,without oral glaucoma medications,or additional glaucoma surgery.RESULTS:The mean pre-operative IOP was 25.38±10.22 mm Hg in the Usights UC100 group and 19.98±3.87 mm Hg in the iTrack group.MAT was achieved in all eyes in both groups.The success rates for the Usights UC100 group and iTrack groups were in all and 4 eyes,respectively.Both microcatheters produced a statistically significant reduction in IOP,and eyes using Usights UC100 achieved a lower IOP than the iTrack group at 3mo followup(12.58±1.52 and 14.84±1.89 mm Hg,respectively),but no statistical significance was there.No severe side effects were observed in either group.CONCLUSION:MAT using Usights UC100 or iTrack both achieve significant pressure reduction in cases of POAG,and Usights UC100 is as safe as iTrack. 展开更多
关键词 illuminated microcatheter microcatheterassisted trabeculotomy primary open angle glaucoma
下载PDF
Controlled illumination and seismic acquisition geometry for target-oriented imaging 被引量:4
9
作者 刘守伟 耿建华 冯伟 《Applied Geophysics》 SCIE CSCD 2005年第4期230-234,共5页
The conventional method of seismic data acquisition geometry design is based on the assumption of horizontal subsurface reflectors, which often is not suitable for complex structure. We start from a controlled illumin... The conventional method of seismic data acquisition geometry design is based on the assumption of horizontal subsurface reflectors, which often is not suitable for complex structure. We start from a controlled illumination analysis and put forward a method of seismic survey geometry design for target-oriented imaging. The method needs a velocity model obtained by a preliminary seismic interpretation. The one-way Fourier finite-difference wave propagator is used to extrapolate plane wave sources on the target layer to the surface. By analyzing the wave energy distribution at the surface extrapolated from the target layer, the shot or receiver locations needed for target layer imaging can be determined. Numerical tests using the SEG-EAGE salt model suggest that this method is useful for confirming the special seismic acquisition geometry layout for target-oriented imaging. 展开更多
关键词 seismic acquisition geometry controlled illumination target-oriented imaging.
下载PDF
AN HIERARCHICAL OCCLUSION TEST ALGORITHM FOR GLOBAL ILLUMINATION SOLUTION
10
作者 孙济洲 吴奇 +1 位作者 邢昌玉 GrimsdaleRL 《Transactions of Tianjin University》 EI CAS 1998年第1期37-41,共5页
This paper presents an efficient hierarchical occlusion test algorithm to support the global illumination solution such as Ray Tracing and Radiosity. This method, which is based on a cone volume intersection examinati... This paper presents an efficient hierarchical occlusion test algorithm to support the global illumination solution such as Ray Tracing and Radiosity. This method, which is based on a cone volume intersection examination, can rapidly remove the irrelevant parts in a scene and find the vertices which fall into the shadow area of a given object. It is an effective alternative to the conventional shadow feeler method. 展开更多
关键词 global illumination RADIOSITY occlusion test Information Engineering
下载PDF
Estimation of illumination chromaticity via adaptive reduced relevance vector machine
11
作者 丁二锐 曾平 +1 位作者 姚勇 王义峰 《Journal of Southeast University(English Edition)》 EI CAS 2007年第2期202-205,共4页
A new regression algorithm of an adaptive reduced relevance vector machine is proposed to estimate the illumination chromaticity of an image for the purpose of color constancy. Within the framework of sparse Bayesian ... A new regression algorithm of an adaptive reduced relevance vector machine is proposed to estimate the illumination chromaticity of an image for the purpose of color constancy. Within the framework of sparse Bayesian learning, the algorithm extends the relevance vector machine by combining global and local kernels adaptively in the form of multiple kernels, and the improved locality preserving projection (LLP) is then applied to reduce the column dimension of the multiple kernel input matrix to achieve less training time. To estimate the illumination chromaticity, the algorithm is trained by fuzzy central values of chromaticity histograms of a set of images and the corresponding illuminants. Experiments with real images indicate that the proposed algorithm performs better than the support vector machine and the relevance vector machine while requiring less training time than the relevance vector machine. 展开更多
关键词 color constancy illumination estimation chromaticity histogram adaptive reduced relevance vector machine
下载PDF
Impact of Illumination and Temperature Performance of Blanket-Inside Solar Greenhouse and CO_2 Enrichment on Cucumber Growth and Development
12
作者 孙潜 崔世茂 +4 位作者 宋阳 杨志刚 董乔 孙世君 伍虹宇 《Agricultural Science & Technology》 CAS 2016年第8期1757-1761,1776,共6页
To evaluate the effects of solar greenhouse with different structure and CO2 enrichment on illumination and temperature performance of greenhouse and cucumber growth and development in the central region of Inner Mong... To evaluate the effects of solar greenhouse with different structure and CO2 enrichment on illumination and temperature performance of greenhouse and cucumber growth and development in the central region of Inner Mongolia, the research used traditional solar greenhouse (A) and blanket-inside solar greenhouse(B), and set 4 treatments: AE (traditional solar greenhouse A with CO2 enrichment), AN (traditional solar greenhouse A without CO2 enrichment), BE (blanket-inside solar greenhouse B with CO2 enrichment) and BN (blanket-inside solar greenhouse B without CO2 enrichment), to explore the influence of cucumber growth, photosynthetic property, quality and yield in different structure solar greenhouses with CO2 enrichment. The results showed that the illumination and temperature in blanket-inside solar greenhouse was superior to traditional solar greenhouse, and the average light intensity in blanket-inside solar greenhouse increased by 21.05%, compared with traditional solar greenhouse. Under the condition of same greenhouse structure, stem height ,average stem diameter, contents of soluble sugar, vitamin C, net photosynthetic rate and yield showed any significant difference between the treatments with CO2 enrichment or not. Under the condition of same CO2 concentration, BE cucumber average stem height, average stem diameter, contents of soluble sugar, net photosynthetic rate and yield in BE was higher than which in AE. Therefore, the optimization in structure of blanket-inside solar greenhouse remarkably improved illumination and temperature property, combining with CO2 enrichment as application technology, there was crucial significance to promote the greenhouse performance and improve the efficiency of greenhouse vegetable production. 展开更多
关键词 Solar greenhouse illumination and temperature performance CO2 Net photosynthetic rate
下载PDF
Parallel Implementation of Global Illumination Using PVM
13
作者 孙济洲 Nicolas D Georganas 《Transactions of Tianjin University》 EI CAS 2002年第3期178-182,共5页
In this paper an attempt of employing network resources to solve a complex and time-consuming problem is presented. The global illumination problem is selected as the study objective. An improved density estimation al... In this paper an attempt of employing network resources to solve a complex and time-consuming problem is presented. The global illumination problem is selected as the study objective. An improved density estimation algorithm is first developed, in which the more inherent concurrency is explored. Then its parallel implementation by using a PVM mechanism and the running performance analysis are provided. The analysis results show the expected speed-up obtained and demonstrate that the PVM has good application prospects for parallel computation in a distributed network. 展开更多
关键词 parallel computation parallel virtual machine(PVM) global illumination distributed network
下载PDF
Germination Characteristics and Secondary Metabolism Regulation of Scutellaria baicalensis Georgi under Different Illumination Time 被引量:4
14
作者 刘金花 李佳 +1 位作者 崔淑兰 张永清 《Agricultural Science & Technology》 CAS 2014年第8期1312-1316,共5页
This study aimed to investigate the primary and secondary metabolism of Scutel aria baicalensis Georgi during seed germination process under different il umination time. [Method] Chlorophyl (CHL) content, soluble su... This study aimed to investigate the primary and secondary metabolism of Scutel aria baicalensis Georgi during seed germination process under different il umination time. [Method] Chlorophyl (CHL) content, soluble sugar content, phenylalanine ammonia lyase (PAL) activity and cinnamate-4-hydroxylase (C4H) ac-tivity were determined with ultraviolet spectrophotometry. The secondary metabolites were detected by high performance liquid chromatography (HPLC). [Result] The re-sults indicated that the germination of S. baicalensis seeds was not sensitive to light and the seedlings were very sensitive to light. CHL content, soluble sugar content, PAL activity and C4H activity increased continuously with the il umination time. The secondary metabolites showed a similar trend. [Conclusion] Il umination time promoted the formation of leaf photosynthetic pigments, thereby affecting the synthesis of primary and secondary metabolites and the activities of PAL and C4H. Therefore, the quality of S. baicalensis can be improved by regulating the il umina-tion time appropriately. 展开更多
关键词 illumination time PAL C4H secondary metabolites
下载PDF
DECREASING PITTING SUSCEPTIBILITY OF PASSIVE FILMS ON X70 PIPELINE STEEL IN NaCl SOLUTIONS BY ILLUMINATION 被引量:2
15
作者 W.C. Zhu W.H. Leng +1 位作者 J.Q. Zhang C.N. Cao 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2006年第2期91-97,共7页
The influence of UV illumination on passivity and pitting susceptibility on X70 pipoeline steel in a borate buffer (pH=8.4 ) solution containing NaCl is described. It is observed that illumination of the sample lead... The influence of UV illumination on passivity and pitting susceptibility on X70 pipoeline steel in a borate buffer (pH=8.4 ) solution containing NaCl is described. It is observed that illumination of the sample leads to a decrease in its pitting susceptibility as indicated by pitting potential and incubation time measurements in chloride containing electrolytes. This effect is strongly dependent on the applied potential during passivation. The electronic properties of the passive films on X70 steel were studied by Mott-Schottky analysis and photocurrent transient measurements. The results indicated that illumination during passivation led to modifications in the electronic properties of the passive films, mainly to a decrease of the bulk doping and an increase in the surface state density. The cause for the decrease in the pitting susceptibility is preliminary explained in terms of such modifications of the passive flm. 展开更多
关键词 X70 pipeline steel pitting susceptibility illumination PASSIVATION
下载PDF
Adaptive illumination light source for online machine vision inspection of tin steel strips 被引量:3
16
作者 PENG Tiegen HE Yonghui 《Baosteel Technical Research》 CAS 2013年第4期25-28,共4页
The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light so... The different reflection characteristics of the surface of tin steel strips and the different speeds of the tinning line demand an adaptive illumination light source for online machine vision inspection. This light source can be integrated with a time delay integration charge-coupled device (TDI CCD ) to capture the images of moving objects and facilitate inspection of the surface quality of tin steel strips. On-site application show the effectiveness of the TDI camera with the adaptive illumination light source in detecting the surface defects on tin steel strips of three different materials and with different tin coating weights. 展开更多
关键词 adaptive illumination light source tin steel strip TDI camera
下载PDF
Gaussian Mixture Models for Human Face Recognition under Illumination Variations 被引量:2
17
作者 Sinjini Mitra 《Applied Mathematics》 2012年第12期2071-2079,共9页
The appearance of a face is severely altered by illumination conditions that makes automatic face recognition a challenging task. In this paper we propose a Gaussian Mixture Models (GMM)-based human face identificatio... The appearance of a face is severely altered by illumination conditions that makes automatic face recognition a challenging task. In this paper we propose a Gaussian Mixture Models (GMM)-based human face identification technique built in the Fourier or frequency domain that is robust to illumination changes and does not require “illumination normalization” (removal of illumination effects) prior to application unlike many existing methods. The importance of the Fourier domain phase in human face identification is a well-established fact in signal processing. A maximum a posteriori (or, MAP) estimate based on the posterior likelihood is used to perform identification, achieving misclassification error rates as low as 2% on a database that contains images of 65 individuals under 21 different illumination conditions. Furthermore, a misclassification rate of 3.5% is observed on the Yale database with 10 people and 64 different illumination conditions. Both these sets of results are significantly better than those obtained from traditional PCA and LDA classifiers. Statistical analysis pertaining to model selection is also presented. 展开更多
关键词 Classification FACE RECOGNITION MIXTURE MODELS illumination
下载PDF
Plane wave shot PSDM and controlled illumination techniques
18
作者 兴福 李宏兵 +2 位作者 胡英 刘桂宝 陈树凯 《Applied Geophysics》 SCIE CSCD 2007年第4期255-262,共8页
The Pre-Stack Depth Migration (PSDM) method based on wavefield continuation is the most reliable method for imaging complex structure in the subsurface, although there are large computational costs and poorly adapti... The Pre-Stack Depth Migration (PSDM) method based on wavefield continuation is the most reliable method for imaging complex structure in the subsurface, although there are large computational costs and poorly adaptive geometry. Plane wave shot migration is another method to perform exact wave equation prestack imaging with high computational efficiency and without the migration aperture problem. Moreover, wavefield energy can be compensated at the target zone by controlled illumination. In this paper, plane wave shot PSDM was implemented by the control of the plane down-going wavefield and selection of number and range of the raypaths in order to optimize the imaging effect. In addition, controlled illumination techniques are applied to enhance the imaging precision of interesting areas at different depths. Numerical calculation indicates that plane wave shot imaging is a rapid and efficient method with less computational cost and easy parallel computation compared to the single-square-root operator imaging for common shot gathers and double- square-root operator imaging for common midpoint gathers. 展开更多
关键词 prestack depth migration wavefield continuation plane wave shot imaging controlled illumination
下载PDF
Nonlinear scanning structured illumination microscopy based on nonsinusoidal modulation 被引量:4
19
作者 Meiting Wang Lei Wang +6 位作者 Xiaomin Zheng Jie Zhou Jiajie Chen Youjun Zeng Junle Qu Yonghong Shao Bruce Zhi Gao 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第5期25-32,共8页
Structured illumination microscopy(SIM)is an essential super-resolution microscopy technique that enhances resolution.Several images are required to reconstruct a super-resolution image.However,linear SIM resolution e... Structured illumination microscopy(SIM)is an essential super-resolution microscopy technique that enhances resolution.Several images are required to reconstruct a super-resolution image.However,linear SIM resolution enhancement can only increase the spatial resolution of micros-copy by a factor of two at most because the frequency of the structured illumination pattern is limited by the cutoff frequency of the excitation point spread function.The frequency of the pattern generated by the nonlinear response in samples is not limited;therefore,nonlinear SIM(NL-SIM),in theory,has no inherent limit to the resolution.In the present study,we describe a two-photon nonlinear SIM(2P-SIM)technique using a multiple harmonics scanning pattern that employs a composite structured illumination pattern,which can produce a higher order harmonic pattern based on the fluorescence nonlinear response in a 2P process.The theoretical models of super-resolution imaging were established through our simulation,which describes the working mechanism of the multi-frequency structure of the nonsinusoidal function to improve the reso-lution.The simulation results predict that a 5-fold improvement in resolution in the 2P-SIM is possible. 展开更多
关键词 Super-resolution image structured illumination microscopy nonsinusoidal function
下载PDF
Structured illumination microscopy based on asymmetric three-beam interference 被引量:3
20
作者 Linyu Xu Yanwei Zhang +4 位作者 Song Lang Hongwei Wang Huijie Hu Jingkai Wang Yan Gong 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2021年第2期40-50,共11页
Structured illumination microscopy(SIM)is a rapidly developing super-resolution technology.It has been widely used in various application fields of biomedicine due to its excellent two-and three-dimensional imaging ca... Structured illumination microscopy(SIM)is a rapidly developing super-resolution technology.It has been widely used in various application fields of biomedicine due to its excellent two-and three-dimensional imaging capabilities.Furthermore,faster three-dimensional imaging methods are required to help enable more research-oriented living cell imaging.In this paper,a fast and sensitive three-dimensional structured illumination microscopy based on asymmetric three-beam interference is proposed.An innovative time-series acquisition method is employed to halve the time required to obtain each raw image.A segmented half-wave plate as a substantial linear polarization modulation method is applied to the three-dimensional SIM system for the first time.Although it needs to acquire 21 raw images instead of 15 to reconstruct one super-resolution image,the SIM setup proposed in this paper is 30%faster than the traditional spatial light modulator-SIM(SLM-SIM)in imaging each super-resolution image.The related theoretical derivation,hardware system,and verification experiment are elaborated in this paper.The stable and fast 3D super-resolution imaging method proposed in this paper is of great significance to the research of organelle interaction,intercellular communication,and other biomedical fields. 展开更多
关键词 SUPER-RESOLUTION structured illumination asymmetric three-beam interference three-dimensional imaging
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部