Limited detection resolution leads to fuzzy areas during the measurement, and the discrimination of the border of a fuzzy area helps to use the resolution stability. In this way, measurement precision is greatly impro...Limited detection resolution leads to fuzzy areas during the measurement, and the discrimination of the border of a fuzzy area helps to use the resolution stability. In this way, measurement precision is greatly improved, hence this phenomenon is named the border effect. The resolution fuzzy area and its application should be studied to realize highresolution measurement. During the measurement of any frequency signal, the fuzzy areas of phase-coincidence detection are always discrete and irregular. In this paper the difficulty in capturing the border information of discrete fuzzy areas is overcome and extra-high resolution measurement is implemented. Measurement precision of any frequency-signal can easily reach better than 1 × 10^-11/s in a wide range of frequencies, showing the great importance of the border effect. An in-depth study of this issue has great significance for frequency standard comparison, signal processing, telecommunication,and fundamental subjects.展开更多
We present a quantitative measurement of the horizontal component of the microwave magnetic field of a coplanar waveguide using a quantum diamond probe in fiber format.The measurement results are compared in detail wi...We present a quantitative measurement of the horizontal component of the microwave magnetic field of a coplanar waveguide using a quantum diamond probe in fiber format.The measurement results are compared in detail with simulation,showing a good consistence.Further simulation shows fiber diamond probe brings negligible disturbance to the field under measurement compared to bulk diamond.This method will find important applications ranging from electromagnetic compatibility test and failure analysis of high frequency and high complexity integrated circuits.展开更多
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th...This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing.展开更多
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on...This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm.展开更多
Introduction The Jiangmen Underground Neutrino Observatory has critical requirements on quality of the liquid scintillator,one of which is long attenuation length.Purpose A system with a height of 3 m is used to preci...Introduction The Jiangmen Underground Neutrino Observatory has critical requirements on quality of the liquid scintillator,one of which is long attenuation length.Purpose A system with a height of 3 m is used to precisely measure the attenuation length of the liquid scintillators.Methods The light generated by a LED is transmitted through an optical fiber.After being focused,filtered and collimated,the light enters the test tube with the liquid scintillator and is detected by the PMT.The stepping motor is controlled by the Labview program to adjust the level of the liquid scintillator,and the emitted light intensity of different liquid levels can be obtained to fit the attenuation length.In addition,the systematic errors have been studied,which includes the measurement error of the emitted light intensity and the error caused by the movement of light spot,and the latter is responded to the non-uniformity of the PMT photocathode.Meanwhile,analytical methods were improved.Results The system can measure the attenuation length stably and a small error was obtained,including statistical error and systematic error(0.69-23.70 m).展开更多
Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz...Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.展开更多
Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated.By controlling the squeezing angle of the squeezed vacuum states,two types of low-frequency quadrature-phase squeezed vacuum states...Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated.By controlling the squeezing angle of the squeezed vacuum states,two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively.A quantum-enhanced fiber Mach–Zehnder interferometer(FMZI)was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected.When phase modulation was measured with the quantumenhanced FMZI,there were above 3 dB quantum improvements beyond the shot-noise limit(SNL)from 40 kHz to 200 kHz,and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained.The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction.There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz.The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber,particularly in the low-frequency range.展开更多
A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performa...A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems.展开更多
Droplet clusters levitating over the locally heated water surface are considered a very promising phe-nomenon of microfluidics for the potential use of the droplets as unique microreactors for microbio-logical experim...Droplet clusters levitating over the locally heated water surface are considered a very promising phe-nomenon of microfluidics for the potential use of the droplets as unique microreactors for microbio-logical experiments.A new optical method is suggested for precise measurements of the sub-micron levitation height of single droplets.The method is based on the analysis of variable colors of the inter-ference halo around the droplet.For the first time,it is possible to measure the extremely low downward velocity of droplets,which grow due to steam condensation.This velocity was found to be 5-8 nm/s.The height of the levitation of various droplets just before their coalescence with a layer of water was also determined.Such measurements might be used for the verification of sophisticated models for the droplet levitation to be developed for a very thin layer of humid air under the droplet when the Knudsen effect should be taken into account.展开更多
Developments of the micro-Gal level gravimeter based on atom interferometry are reviewed, and the recent progress and results of our group are also presented. Atom interferometric gravimeters have shown high resolutio...Developments of the micro-Gal level gravimeter based on atom interferometry are reviewed, and the recent progress and results of our group are also presented. Atom interferometric gravimeters have shown high resolution and accuracy for gravity measurements. This kind of quantum sensor has excited world-wide interest for both practical applications and fundamental research.展开更多
The transformation between time and space is discussed. To improve real-time response speed of intelligent measuring system, the concept of exchanging program execution time with more circuitry is presented working in...The transformation between time and space is discussed. To improve real-time response speed of intelligent measuring system, the concept of exchanging program execution time with more circuitry is presented working in cycle mode. Displacement measuring by magnification is achieved with period measurement by magnification. To change the condition that traditional precision measurement depends on machining precision greatly, the concept of measuring space with time and theory of time-space coordinate transformation are proposed. Guided by the idea of measuring space with time, differential frequency measurement system and time grating displacement sensor are developed based on the proposed novel methods. And high-precision measurement is achieved without high-precision manufacture, which embeds the remarkable characteristics of low cost but high precision to the devices. Experiment and test results conform the validity of the proposed time-space concept.展开更多
Development of atom interferometry and its application in precision measurement are reviewed in this paper. The principle, features and the implementation of atom interferometers are introduced, the recent progress of...Development of atom interferometry and its application in precision measurement are reviewed in this paper. The principle, features and the implementation of atom interferometers are introduced, the recent progress of precision measurement with atom interferometry, including determination of gravitational constant and fine structure constant, measurement of gravity, gravity gradient and rotation, test of weak equivalence principle, proposal of gravitational wave detection, and measurement of quadratic Zeeman shift are reviewed in detail. Determination of gravitational redshift, new definition of kilogram, and measurement of weak force with atom interferometry are also briefly introduced.展开更多
It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with d...It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.展开更多
It is significant for establishing gravity datum to construct precise gravity solid tidal model,A simple method with relatively low performance is to interpolate tidal parameters from the global gravity solid tide mod...It is significant for establishing gravity datum to construct precise gravity solid tidal model,A simple method with relatively low performance is to interpolate tidal parameters from the global gravity solid tide models.A competitive approach is to determine local gravity solid tidal model by harmonic analysis using long-time serial gravity observations.In this paper a new high-precision gravity solid tidal model for Precision Gravity Measurement Facility is estimated from two co-site gravimeters in the cave laboratory using modern international standard data processing techniques,whose accuracy is evaluated further by comparing with previous publications.The results show that:(1)the determined gravity solid tidal models from two co-site gravimeters are in good agreement with each other,of which the maximum differences for amplitude factors and phase delays don’t exceed 0.01700%and 2.50990°,respectively.(2)the performance of the obtained gravity solid tidal model is 0.00411 for amplitude factors and 0.24120°for phase delays,which is a little better than that of previous publications using superconducting gravity data from Wuhan station.(3)our results and methods are corrective and effective.(4)our model is tiny different from that provided by Wuhan station,which implies that it is necessary to construct a gravity solid tidal model for Precision Gravity Measurement Facility,rather than just adopting existing models at Wuhan station.Our results are helpful in realizing the goal of Precision Gravity Measurement Facility.展开更多
Recent progresses on quantum control of cold atoms and trapped ions in both the scientific and technological aspects greatly advance the applications in precision measurement. Thanks to the exceptional controllability...Recent progresses on quantum control of cold atoms and trapped ions in both the scientific and technological aspects greatly advance the applications in precision measurement. Thanks to the exceptional controllability and versatility of these massive quantum systems, unprecedented sensitivity has been achieved in clocks, magnetometers, and interferometers based on cold atoms and ions. Besides, these systems also feature many characteristics that can be employed to facilitate the applications in different scenarios. In this review, we briefly introduce the principles of optical clocks, cold atom magnetometers, and atom interferometers used for precision measurement of time, magnetic field, and inertial forces. The main content is then devoted to summarize some recent experimental and theoretical progresses in these three applications, with special attention being paid to the new designs and possibilities towards better performance. The purpose of this review is by no means to give a complete overview of all important works in this fast developing field, but to draw a rough sketch about the frontiers and show the fascinating future lying ahead.展开更多
The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 ...The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 × 10-13@1 s is employed for the light source. By using a periodically poled lithium niobate, the femtosecond pulse operating in 1556 nm is frequency-doubled to 778 nm to obtain the direct two-photon transition spectroscopy of thermal rubidium vapor. Through sweeping the carrier envelope offset frequency (fceo), the 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition line is clearly resolved and its absolute frequency is determined via the peak-finding of the fitting curve. After the frequency correction, the measured result agrees well with the previous experiment on this transition. The entire potential candidate of optical frequency standard for system configuration is compact and robust, providing a telecommunication applications.展开更多
Based upon the new designed helical resonator,the resonant radio frequency(RF)for trapping ions can be consec-utively adjusted in a large range(about 12 MHz to 29 MHz)with high Q-factors(above 300).We analyze the heli...Based upon the new designed helical resonator,the resonant radio frequency(RF)for trapping ions can be consec-utively adjusted in a large range(about 12 MHz to 29 MHz)with high Q-factors(above 300).We analyze the helical resonator with a lumped element circuit model and find that the theoretical results fit well with the experimental data.With our resonator system,the resonant frequency near magic RF frequency(where the scalar Stark shift and the second-order Doppler shift due to excess micromotion cancel each other)can be continuously changed at kHz level.For ^(88)Sr^(+) ion,compared to earlier results,the measurement accuracy of magic RF frequency can be improved by an order of magnitude upon rough calculation,and therefore the net micromotion frequency shifts can be further reduced.Also,the differential static scalar polarizability △α0 of clock transition can be experimentally measured more accurately.展开更多
1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its...1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its following properties:(1)Hf-W fractionation commonly occurs during metal-silicate differentiation;(2)Both Hf and W are highly refractory elements,therefore most bulk展开更多
If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in ...If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in the periodic states, the periodic numbers would be changed most with the signals. Our novel method is to add chaotic dynamic vibration to the measurement or sensor system.The sensor sensitivity and precision of a measurement system would be improved with this method. Chaotic dynamics measurement algorithms are given and their sensitivity to parameters are analyzed in this paper. The effects of noises on the system are discussed.展开更多
The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrin...The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.10978017 and 61201288)the Natural Science Foundation of Research Plan Projects of Shaanxi Province+1 种基金China(Grant No.2014JM2–6128)the Sino-Poland Science and Technology Cooperation Projects(Grant No.36-33)
文摘Limited detection resolution leads to fuzzy areas during the measurement, and the discrimination of the border of a fuzzy area helps to use the resolution stability. In this way, measurement precision is greatly improved, hence this phenomenon is named the border effect. The resolution fuzzy area and its application should be studied to realize highresolution measurement. During the measurement of any frequency signal, the fuzzy areas of phase-coincidence detection are always discrete and irregular. In this paper the difficulty in capturing the border information of discrete fuzzy areas is overcome and extra-high resolution measurement is implemented. Measurement precision of any frequency-signal can easily reach better than 1 × 10^-11/s in a wide range of frequencies, showing the great importance of the border effect. An in-depth study of this issue has great significance for frequency standard comparison, signal processing, telecommunication,and fundamental subjects.
基金Project supported by the National Key Research and Development Program of China (Grant No.2021YFB2012600)。
文摘We present a quantitative measurement of the horizontal component of the microwave magnetic field of a coplanar waveguide using a quantum diamond probe in fiber format.The measurement results are compared in detail with simulation,showing a good consistence.Further simulation shows fiber diamond probe brings negligible disturbance to the field under measurement compared to bulk diamond.This method will find important applications ranging from electromagnetic compatibility test and failure analysis of high frequency and high complexity integrated circuits.
文摘This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing.
文摘This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(XDA10010500)National Natural Science Foundation of China(11390384).
文摘Introduction The Jiangmen Underground Neutrino Observatory has critical requirements on quality of the liquid scintillator,one of which is long attenuation length.Purpose A system with a height of 3 m is used to precisely measure the attenuation length of the liquid scintillators.Methods The light generated by a LED is transmitted through an optical fiber.After being focused,filtered and collimated,the light enters the test tube with the liquid scintillator and is detected by the PMT.The stepping motor is controlled by the Labview program to adjust the level of the liquid scintillator,and the emitted light intensity of different liquid levels can be obtained to fit the attenuation length.In addition,the systematic errors have been studied,which includes the measurement error of the emitted light intensity and the error caused by the movement of light spot,and the latter is responded to the non-uniformity of the PMT photocathode.Meanwhile,analytical methods were improved.Results The system can measure the attenuation length stably and a small error was obtained,including statistical error and systematic error(0.69-23.70 m).
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 12174446 and 61671458)。
文摘Low-noise high-stability current sources have essential applications such as neutron electric dipole moment measurement and high-stability magnetometers. Previous studies mainly focused on frequency noise above 0.1 Hz while less on the low-frequency noise/drift. We use double resonance alignment magnetometers(DRAMs) to measure and suppress the low-frequency noise of a homemade current source(CS) board. The CS board noise level is suppressed by about 10 times in the range of 0.001-0.1 Hz and is reduced to 100 n A/√Hz at 0.001 Hz. The relative stability of CS board can reach2.2 × 10^(-8). In addition, the DRAM shows a better resolution and accuracy than a commercial 7.5-digit multimeter when measuring our homemade CS board. Further, by combining the DRAM with a double resonance orientation magnetometer,we may realize a low-noise CS in the 0.001-1000 Hz range.
基金Project supported by the National Natural Science Foundation of China(Grant No.62175135)the Fundamental Research Program of Shanxi Province(Grant No.202103021224025)。
文摘Stable low-frequency squeezed vacuum states at a wavelength of 1550 nm were generated.By controlling the squeezing angle of the squeezed vacuum states,two types of low-frequency quadrature-phase squeezed vacuum states and quadrature-amplitude squeezed vacuum states were obtained using one setup respectively.A quantum-enhanced fiber Mach–Zehnder interferometer(FMZI)was demonstrated for low-frequency phase measurement using the generated quadrature-phase squeezed vacuum states that were injected.When phase modulation was measured with the quantumenhanced FMZI,there were above 3 dB quantum improvements beyond the shot-noise limit(SNL)from 40 kHz to 200 kHz,and 2.3 dB quantum improvement beyond the SNL at 20 kHz was obtained.The generated quadrature-amplitude squeezed vacuum state was applied to perform low-frequency amplitude modulation measurement for sensitivity beyond the SNL based on optical fiber construction.There were about 2 dB quantum improvements beyond the SNL from 60 kHz to 200 kHz.The current scheme proves that quantum-enhanced fiber-based sensors are feasible and have potential applications in high-precision measurements based on fiber,particularly in the low-frequency range.
基金Sponsored by the National Natural Science Foundation of China(Grant No.52175491).
文摘A method was proposed to analyze the influences of the non-ideal spectroscopic performance of optical components and orientation errors of a laser tracing measurement optical system on the tracing measurement performance.A comprehensive model of the interference fringe contrast based on the laser tracing system s measurement principle was established in this study.Simulation results based on ZEMAX verified the model.According to the simulation results,the placement angle of the analyzer had a direct influence on the interference fringe contrast.When the angle of the polarized light to the analyzer’s transmission axis increased from 65°to 85°,each contrast of the four-way interference fringes decreased from 0.9996 to 0.3528,the interference fringe contrast is decreased by 65%.Under the split ratio of beam splitters in the interference part(BS 1)of 5∶5,when the splitting ratio of BS 2 changed from 2∶8 to 8∶2,the fringe contrast of the interference signals received by the photodetectors increased,but the injection light intensity onto the PSD reflected by BS 2 decreased.The significant influence of the tracing performance was verified by the experiments.When splitting ratio of BS 2 increased,the contrast of the interference fringes increased.Due to the weakening of the incident light intensity of the PSD caused by the change of BS 2 splitting ratio,the response time of the tracing system is increased by 23.7 ms.As a result,the tracing performance of the laser tracing measurement optical system was degraded.An important theoretical basis was provided to evaluate and improve the accuracy and reliability of laser tracing measurement systems.
基金support by the Ministry of Science and Higher Education of the Russian Federation (project No.FEWZ-2023-0002).
文摘Droplet clusters levitating over the locally heated water surface are considered a very promising phe-nomenon of microfluidics for the potential use of the droplets as unique microreactors for microbio-logical experiments.A new optical method is suggested for precise measurements of the sub-micron levitation height of single droplets.The method is based on the analysis of variable colors of the inter-ference halo around the droplet.For the first time,it is possible to measure the extremely low downward velocity of droplets,which grow due to steam condensation.This velocity was found to be 5-8 nm/s.The height of the levitation of various droplets just before their coalescence with a layer of water was also determined.Such measurements might be used for the verification of sophisticated models for the droplet levitation to be developed for a very thin layer of humid air under the droplet when the Knudsen effect should be taken into account.
基金supported by the National Natural Science Foundation of China(Grant Nos.41127002,11204094,11205064,and 11474115)the National High Technology Research and Development Program of China(Grant No.2011AA060503)
文摘Developments of the micro-Gal level gravimeter based on atom interferometry are reviewed, and the recent progress and results of our group are also presented. Atom interferometric gravimeters have shown high resolution and accuracy for gravity measurements. This kind of quantum sensor has excited world-wide interest for both practical applications and fundamental research.
基金National Natural Science Foundation of China(No.59575095,No.59675089,No.50075091,No.50575235)
文摘The transformation between time and space is discussed. To improve real-time response speed of intelligent measuring system, the concept of exchanging program execution time with more circuitry is presented working in cycle mode. Displacement measuring by magnification is achieved with period measurement by magnification. To change the condition that traditional precision measurement depends on machining precision greatly, the concept of measuring space with time and theory of time-space coordinate transformation are proposed. Guided by the idea of measuring space with time, differential frequency measurement system and time grating displacement sensor are developed based on the proposed novel methods. And high-precision measurement is achieved without high-precision manufacture, which embeds the remarkable characteristics of low cost but high precision to the devices. Experiment and test results conform the validity of the proposed time-space concept.
基金supported by the National Basic Research Program of China(Grant No.2010CB832805)the National Natural Science Foundation of China(Grant No.11227803)
文摘Development of atom interferometry and its application in precision measurement are reviewed in this paper. The principle, features and the implementation of atom interferometers are introduced, the recent progress of precision measurement with atom interferometry, including determination of gravitational constant and fine structure constant, measurement of gravity, gravity gradient and rotation, test of weak equivalence principle, proposal of gravitational wave detection, and measurement of quadratic Zeeman shift are reviewed in detail. Determination of gravitational redshift, new definition of kilogram, and measurement of weak force with atom interferometry are also briefly introduced.
基金Supported by the National Natural Science Foundation of China (No.60102002)the Huoyingdong Education Foundation (No.81057)the Doctoral Foundation of Hebei Province of China(No.B2004522).
文摘It is critical for cerebral vascular disease diagnosis through Doppler to detect the maximum and the minimum of the carotid blood flow speed accurately. A kind of Duffing system under an external periodic power with dump is introduced in the letter, numerical analysis is carried out by four-order Runge-Kutta method. An oscillator array is designed according to the frequency of the ultrasonic wave. When the external signals are inputted, computational algorithm is used to scan the array in turn and analyze the result, and the frequency can be determined. Based on the methods above, detecting the carotid blood flow speed accurately is realized. The Signal-to-Noise Ratio (SNR) of-20.23dB is obtained by the result of experiments. In conclusion, the SNR has been improved and the precision of the measured bloodstream speed has been increased, which can be 0.069% to 0.13%.
基金supported by the National Natural Science Foundation of China(Grant No.41974014)the Open Fund of State Laboratory of Information Engineering in Surveying,Mapping and Remote Sensing,Wuhan University(Grant No.19P01)
文摘It is significant for establishing gravity datum to construct precise gravity solid tidal model,A simple method with relatively low performance is to interpolate tidal parameters from the global gravity solid tide models.A competitive approach is to determine local gravity solid tidal model by harmonic analysis using long-time serial gravity observations.In this paper a new high-precision gravity solid tidal model for Precision Gravity Measurement Facility is estimated from two co-site gravimeters in the cave laboratory using modern international standard data processing techniques,whose accuracy is evaluated further by comparing with previous publications.The results show that:(1)the determined gravity solid tidal models from two co-site gravimeters are in good agreement with each other,of which the maximum differences for amplitude factors and phase delays don’t exceed 0.01700%and 2.50990°,respectively.(2)the performance of the obtained gravity solid tidal model is 0.00411 for amplitude factors and 0.24120°for phase delays,which is a little better than that of previous publications using superconducting gravity data from Wuhan station.(3)our results and methods are corrective and effective.(4)our model is tiny different from that provided by Wuhan station,which implies that it is necessary to construct a gravity solid tidal model for Precision Gravity Measurement Facility,rather than just adopting existing models at Wuhan station.Our results are helpful in realizing the goal of Precision Gravity Measurement Facility.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11522436,11774425,11704408,and 91836106)the Beijing Natural Science Foundation,China(Grant No.Z180013)+1 种基金the Joint Fund of the Ministry of Education of China(Grant No.6141A020333xx)the Research Funds of Renmin University of China(Grant Nos.16XNLQ03 and 18XNLQ15).
文摘Recent progresses on quantum control of cold atoms and trapped ions in both the scientific and technological aspects greatly advance the applications in precision measurement. Thanks to the exceptional controllability and versatility of these massive quantum systems, unprecedented sensitivity has been achieved in clocks, magnetometers, and interferometers based on cold atoms and ions. Besides, these systems also feature many characteristics that can be employed to facilitate the applications in different scenarios. In this review, we briefly introduce the principles of optical clocks, cold atom magnetometers, and atom interferometers used for precision measurement of time, magnetic field, and inertial forces. The main content is then devoted to summarize some recent experimental and theoretical progresses in these three applications, with special attention being paid to the new designs and possibilities towards better performance. The purpose of this review is by no means to give a complete overview of all important works in this fast developing field, but to draw a rough sketch about the frontiers and show the fascinating future lying ahead.
基金Supported by the National Natural Science Foundation of China under Grant Nos 61405002,91336103,10934010,61535001 and 61078026
文摘The absolute frequency of 87Rb 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition at 778nm is measured in an accuracy of 44kHz. A home-made erbium-doped fiber laser frequency comb with frequency stability of 5.0 × 10-13@1 s is employed for the light source. By using a periodically poled lithium niobate, the femtosecond pulse operating in 1556 nm is frequency-doubled to 778 nm to obtain the direct two-photon transition spectroscopy of thermal rubidium vapor. Through sweeping the carrier envelope offset frequency (fceo), the 5S1/2 (F=2)→5D5/2 (F" = 4) two-photon transition line is clearly resolved and its absolute frequency is determined via the peak-finding of the fitting curve. After the frequency correction, the measured result agrees well with the previous experiment on this transition. The entire potential candidate of optical frequency standard for system configuration is compact and robust, providing a telecommunication applications.
基金Project supported by the Key-Area Research and Development Program of Guangdong Province,China(Grant No.2019B030330001)the National Natural ScienceFoundation of China(Grant Nos.12025509 and 11904418)+1 种基金the Science and Technology Program of Guangzhou,China(Grant No.201904020024)the Fundamental Research Funds for the Central Universities,China.
文摘Based upon the new designed helical resonator,the resonant radio frequency(RF)for trapping ions can be consec-utively adjusted in a large range(about 12 MHz to 29 MHz)with high Q-factors(above 300).We analyze the helical resonator with a lumped element circuit model and find that the theoretical results fit well with the experimental data.With our resonator system,the resonant frequency near magic RF frequency(where the scalar Stark shift and the second-order Doppler shift due to excess micromotion cancel each other)can be continuously changed at kHz level.For ^(88)Sr^(+) ion,compared to earlier results,the measurement accuracy of magic RF frequency can be improved by an order of magnitude upon rough calculation,and therefore the net micromotion frequency shifts can be further reduced.Also,the differential static scalar polarizability △α0 of clock transition can be experimentally measured more accurately.
基金supported by funds from the National Natural Science Foundation of China (No. 41521062, 41490631)
文摘1 Introduction The short-lived 182Hf-182W system is generally acknowledged as the best chronometer of metal-silicate segregation that occurred during the early evolution of asteroids and terrestrial planets due to its following properties:(1)Hf-W fractionation commonly occurs during metal-silicate differentiation;(2)Both Hf and W are highly refractory elements,therefore most bulk
文摘If the measuring signals were input to the chaotic dynamic system as initial parameters, the system outputs might be in steady state, periodic state or chaos state. If the chaotic dynamic system outputs controlled in the periodic states, the periodic numbers would be changed most with the signals. Our novel method is to add chaotic dynamic vibration to the measurement or sensor system.The sensor sensitivity and precision of a measurement system would be improved with this method. Chaotic dynamics measurement algorithms are given and their sensitivity to parameters are analyzed in this paper. The effects of noises on the system are discussed.
基金Hubei Province Natural Science Fund Project,China(No.2013CFA090)
文摘The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.