Four exterior joints with special-shaped columns which have different lengths of limbs are tested under low cyclic loading. Speeial-shaped columns adopted are L- and T-shaped in section. It can be concluded that crack...Four exterior joints with special-shaped columns which have different lengths of limbs are tested under low cyclic loading. Speeial-shaped columns adopted are L- and T-shaped in section. It can be concluded that crack pattern, failure mode and shear strength of joints are affected by the length of limb, and that shear strength and ductility increase with the length of limb; the joints with the flexural failure of the beam have better seismic behavior than those with the shear failure of the joint core.展开更多
To overcome the problem that steel bars are put too close at a flame joint with special-shaped beam and column,mechanical performance of three groups of six RC flame joints with special-shaped(L,T and+)column and disp...To overcome the problem that steel bars are put too close at a flame joint with special-shaped beam and column,mechanical performance of three groups of six RC flame joints with special-shaped(L,T and+)column and dispersed-steel bars-beam on the top floor under cyclic loads were studied.Experimental comparison was conducted between special-shaped(L,T and+)column and normal beams.The cracking load,yielding load,ultimate bearing capacity,failure patterns,and hysteretic properties at joint core area were investigated.The seismic behaviors of the joints with different proportions of dispersed-steelbar beams were analyzed.The results of experimental analysis indicate that the mechanical and seismic behaviors of frame joints with T-shaped and+-shaped column are nearly not changed when suitable proportion steel bars are dispersed to flange plane.Stiffness degeneration of flame joint with L-shaped column is rather serious due to concrete damage stiffness.Theoretical result indicates that distributing area of the dispersed steel-bar beams in the flange plate should be strictly controlled to avoid anchor destroy.展开更多
文摘Four exterior joints with special-shaped columns which have different lengths of limbs are tested under low cyclic loading. Speeial-shaped columns adopted are L- and T-shaped in section. It can be concluded that crack pattern, failure mode and shear strength of joints are affected by the length of limb, and that shear strength and ductility increase with the length of limb; the joints with the flexural failure of the beam have better seismic behavior than those with the shear failure of the joint core.
基金This work was partly financial supported by the National Natural Science Foundation of China(Grant No.50678016).
文摘To overcome the problem that steel bars are put too close at a flame joint with special-shaped beam and column,mechanical performance of three groups of six RC flame joints with special-shaped(L,T and+)column and dispersed-steel bars-beam on the top floor under cyclic loads were studied.Experimental comparison was conducted between special-shaped(L,T and+)column and normal beams.The cracking load,yielding load,ultimate bearing capacity,failure patterns,and hysteretic properties at joint core area were investigated.The seismic behaviors of the joints with different proportions of dispersed-steelbar beams were analyzed.The results of experimental analysis indicate that the mechanical and seismic behaviors of frame joints with T-shaped and+-shaped column are nearly not changed when suitable proportion steel bars are dispersed to flange plane.Stiffness degeneration of flame joint with L-shaped column is rather serious due to concrete damage stiffness.Theoretical result indicates that distributing area of the dispersed steel-bar beams in the flange plate should be strictly controlled to avoid anchor destroy.