The wearing comfort of clothing has been frequently investigated,but there are few researches on the wearing comfort of pantyhose. This study first carried out a questionnaire survey on female consumers to know about ...The wearing comfort of clothing has been frequently investigated,but there are few researches on the wearing comfort of pantyhose. This study first carried out a questionnaire survey on female consumers to know about their preference and demand on pantyhose. Then thermal manikin test and subject wearing trials were performed to evaluate the commonly used pantyhose. It was found that female consumers felt cold on the legs when wearing pantyhose which puts forward more requirements on pantyhose for its ability to keep warm. The thinner and more permeable the pantyhose,the thermal insulation was smaller. And the thicker the pantyhose,the pressure it caused to the body was higher. Sample 1# brought the highest prickle sensation, and prickle sensation was increased with the movement of the body. Samples 2# and 3# caused the highest and lowest thermal sensation,which was in line with their thermal insulation.展开更多
基金Young University Teacher Training Program by Shanghai,China(No.ZZGCD15051)Start up Foundation by Shanghai University of Engineering Science,China(No.2015-69)
文摘The wearing comfort of clothing has been frequently investigated,but there are few researches on the wearing comfort of pantyhose. This study first carried out a questionnaire survey on female consumers to know about their preference and demand on pantyhose. Then thermal manikin test and subject wearing trials were performed to evaluate the commonly used pantyhose. It was found that female consumers felt cold on the legs when wearing pantyhose which puts forward more requirements on pantyhose for its ability to keep warm. The thinner and more permeable the pantyhose,the thermal insulation was smaller. And the thicker the pantyhose,the pressure it caused to the body was higher. Sample 1# brought the highest prickle sensation, and prickle sensation was increased with the movement of the body. Samples 2# and 3# caused the highest and lowest thermal sensation,which was in line with their thermal insulation.