When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necess...When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.展开更多
Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled tr...Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.展开更多
Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hy...Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.展开更多
Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese...Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese subjects, those with secondary hypertension or resistant, diabetics, subjects with metabolic syndrome or sleep apnea syndrome. The objective of this study was to evaluate the contribution of ABPM in the diagnosis and evaluation of the level of control of hypertension under treatment at the Bel Air international clinic. Materials and Methods: This is a retrospective, cross-sectional and descriptive study, carried out at the Bel Air International Clinic in Conakry (Guinea) between January 2019 and November 30, 2022. It included a consecutive series of 180 consenting patients recruited through an ambulatory measurement of 24-hour blood pressure from a FUGADA brand device. Results: We collected 180 patients, with a male predominance (sex-ratio M/F = 2.46). The mean age of the patients was 48.48 ± 14.23 years. The most represented age group was that of 32 to 42 years with 50 cases (27.8%) followed by that of 43 to 52 years with 42 cases or 23.3%. The indication was for diagnostic purposes in 106 cases 58.9%, the therapeutic evaluation in 58 patients (32.2%). The examination was prescribed by a cardiologist in 98 cases (54.4%), a general practitioner in 71 cases (39.4%), a neurologist in 11 cases (6.1%). In the therapeutic evaluation, high blood pressure was controlled in 24 patients (13.3%) and uncontrolled in 34 cases (18.9%). In the diagnostic indication, high blood pressure was confirmed in 79 cases (43.9%) with a statistically significant link (Chi2</sup> = 4.57 and p-value = 0.032). The nycthemeral mean was 187.27 ± 26.22 mmHg for systolic blood pressure (SBP) and 110.37 ± 19.06 mmHg for diastolic blood pressure (DBP), during the day, 151.64 ± 21.45 mmHg for SBP and 71.59 ± 8.67 mmHg for diastolic blood pressure. During the study 65 patients (36.1%) were identified as dippers and 115 patients (63.9%) were no-dipping. The antihypertensive protocol used was monotherapy in 68 cases (37.8%), dual therapy in 46 cases (25.6%), triple therapy in 17 cases (9.4%). However 39 patients or 21.7% were not taking any antihypertensive. Conclusion: This preliminary study, despite the modest sample size, showed the importance of ABPM as a tool for diagnosis, monitoring of hypertensive patients and therapeutic adaptation. A large-scale national study would be necessary for the rational use of ambulatory blood pressure measurement in our context in order to improve the management of hypertensive patients.展开更多
Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and an...Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and another 80 patients with diabetes(diabetic group)who were admitted to the Department of Nephrology and Endocrinology at our hospital from October 2021 to October 2022 was conducted.The general data of the two groups were compared,the influencing factors associated with the two groups were analyzed unilaterally,and unconditional dichotomous logistic regression was performed to analyze the influencing factors in patients with diabetic nephropathy.Results:There were no significant differences in high-density lipoprotein,systolic blood pressure,diastolic blood pressure,and creatinine between the two groups(P>0.05);however,compared with the diabetic group,the DN group had significantly elevated glycated hemoglobin,low-density lipoprotein,24-h urine protein,insulin resistance,and diabetes duration≥10 years(P<0.05).Conclusion:The clinical research on the correlation between the incidence of hypertension and the control of blood pressure in patients with diabetic nephropathy should be strengthened in order to formulate reasonable and feasible treatment plans.展开更多
In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of t...In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.展开更多
An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy...An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.展开更多
Water-assisted injection molding(WAIM),a newly developed fluid-assisted injection molding technology has drawn more and more attentions for the energy saving,short cooling circle time and high quality of products.Ex...Water-assisted injection molding(WAIM),a newly developed fluid-assisted injection molding technology has drawn more and more attentions for the energy saving,short cooling circle time and high quality of products.Existing research for the process of WAIM has shown that the pressure control of the injecting water is mostly important for the WAIM.However,the proportional pressure control for the WAIM system is quite complex due to the existence of nonlinearities in the water hydraulic system.In order to achieve better pressure control performance of the injecting water to meet the requirements of the WAIM,the proportional pressure control of the WAIM system is investigated both numerically and experimentally.A newly designed water hydraulic system for WAIM is first modeled in AMEsim environment,the load characteristics and the nonlinearities of water hydraulic system are both considered,then the main factors affecting the injecting pressure and load flow rate are extensively studied.Meanwhile,an open-loop model-based compensation control strategy is employed to regulate the water injection pressure and a feedback proportional integrator controller is further adopted to achieve better control performance.In order to verify the AMEsim simulation results WAIM experiment for particular Acrylonitrile Butadiene Styrene(ABS) parts is implemented and the measured experimental data including injecting pressure and flow rate results are compared with the simulation.The good coincidence between experiment and simulation shows that the AMEsim model is accurate,and the tracking performance of the load pressure indicates that the proposed control strategy is effective for the proportional pressure control of the nonlinear WAIM system.The proposed proportional pressure control strategy and the conclusions drawn from simulation and experiment contribute to the application of water hydraulic proportional control and WAIM technology.展开更多
AIM: To train Tibetan monkey (Macaca thibetana) for intraocular pressure (IOP) measurement in conscious state and obtain normal IOP in conscious Tibetan Macaque. METHODS: The training was based on award-conditioned be...AIM: To train Tibetan monkey (Macaca thibetana) for intraocular pressure (IOP) measurement in conscious state and obtain normal IOP in conscious Tibetan Macaque. METHODS: The training was based on award-conditioned behavior. Food stimulation and human-animal interaction were used in this training. RESULTS: Trained Tibetan monkeys calmly accepted IOP measurement by the TonoVete (R) rebound tonometer without sedation or anesthesia and their IOP values were similar to other primates. CONCLUSION: Human-cultivated Thibetan monkeys are tamable, and can be used for biomedical research such as ophthalmic research without anesthesia.展开更多
In this paper, a novel antenna is proposed for high-temperature testing, which can make the high-temperature pressure characteristics of a wireless passive ceramic pressure sensor demonstrated at up to a temperature o...In this paper, a novel antenna is proposed for high-temperature testing, which can make the high-temperature pressure characteristics of a wireless passive ceramic pressure sensor demonstrated at up to a temperature of 600℃. The design parameters of the antenna are similar to those of the sensor, which will increase the coupling strength between the sensor and testing antenna. The antenna is fabricated in thick film integrated technology, and the properties of the alumina ceramic and silver ensure the feasibility of the antenna in high-temperature environments. The sensor, coupled with the ceramic antenna, is investigated using a high-temperature pressure testing platform. The experimental measurement results show that the pressure signal in a harsh environment can be detected by the frequency diversity of the sensor.展开更多
In this paper the control mechanism of solenoid valve is analyzed,which shows the solenoid valve control is actually the control of coil current.The response characteristic of coil current is related to coil inductanc...In this paper the control mechanism of solenoid valve is analyzed,which shows the solenoid valve control is actually the control of coil current.The response characteristic of coil current is related to coil inductance and resistance.The coil resistance is influenced greatly by the ambient temperature and the self-heating of coil,which affects the control precision of coil current.First,considering the heat dissipation mode of coil,the coil temperature model is established from the perspective of heat conduction,and a temperature compensation algorithm for hydraulic system pressure control is put forward.Then the hardware-in-the-loop testbed is set up by using the dSPACE platform,carrying out wheel cylinder pressurization tests with inlet valve fully opened at-40℃ and 20℃,and testing the actual pressure of wheel cylinder with the target pressures at-40℃ and 6 000 kPa/s(pressurization rate).The results show that the pressure control temperature compensation algorithm proposed in this paper accurately corrects the influence of resistance temperature drift on the response accuracy of wheel cylinder pressure.After the correction,the pressure difference is less than 500 kPa,which can meet the control accuracy requirements of solenoid valve,enriching the linear control characteristic of solenoid valve.展开更多
It is very important to maintain the level of mean arterial pressure (MAP). The MAP control is applied in many clinical situations, including limiting bleeding during cardiac surgery and promoting healing for patien...It is very important to maintain the level of mean arterial pressure (MAP). The MAP control is applied in many clinical situations, including limiting bleeding during cardiac surgery and promoting healing for patient' s post-surgery. This paper presents a fuzzy controller-based multiple-model adaptive control system for postoperative blood pressure management. Multiple-model adaptive control (MMAC) algorithm is used to identify the patient model, and it is a feasible system identification method even in the presence of large noise. Fuzzy control (FC) method is used to design controller bank. Each fuzzy controller in the controller bank is in fact a nonlinear proportional-integral (PI) controller,whose proportional gain and integral gain are adjusted continuously according to error and rate of change of error of the plant output, resulting in better dynamic and stable control performance than the regular PI controller, especially when a nonlinear process is involved. For demonstration, a nonlinear, pulsatile-flow patient model is used for simulation, and the results show that the adaptive control system can effectively handle the changes in patient's dynamics and provide satisfactory performance in regulation of blood pressure of hypertension patients.展开更多
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood ...This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators.The proposed platform measured the signal changes in PPG and converted them into physiological indicators,such as pulse transit time(PTT),pulse wave velocity(PWV),perfusion index(PI)and heart rate(HR);these indicators were then fed into the DL to calculate blood pressure.The hardware of the experiment comprised 2 PPG components(i.e.,Raspberry Pi 3 Model B and analog-todigital converter[MCP3008]),which were connected using a serial peripheral interface.The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean arterial pressure(MAP).To increase the robustness of the DL model,this study input data of 100 Asian participants into the training database,including those with and without cardiovascular disease,each with a proportion of approximately 50%.The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17±0.46 mmHg.The mean absolute error and standard deviation of DBP was 0.27±0.52 mmHg.The mean absolute error and standard deviation of MAP was 0.16±0.40 mmHg.展开更多
Static cracking agent(SCA)is actively investigated as an alternative to explosive blasting for rock breakage due to its immense expansion property.SCA can eliminate the negative effects of shock,noise and harmful gase...Static cracking agent(SCA)is actively investigated as an alternative to explosive blasting for rock breakage due to its immense expansion property.SCA can eliminate the negative effects of shock,noise and harmful gases encountered in explosive blasting processes.Accurate measurement and deep understanding of the expansive properties of SCAs are important in their industrial application.An improved outer pipe method(OPM),termed the upper end surface method(UESM),is proposed in this paper to overcome the shortcomings of the OPM in the expansive pressure measurement of SCAs.Numerical simulation is used to proof the concept and a mathematical model established to relate the internal pressure and the radial strains at different positions in the upper end surface method test equipment.The new equipment is calibrated using oil pressure and strain measurements.The calibrated equipment is then used to measure the expansion pressure of SCA at three different water contents to proof its potential.The differences in the measurements with OPM and UESM at three different moisture contents are less than 4%.The experimental results confirm the accuracy and applicability of the more user friendly and less expensive UESM in the measurement of the expansive pressures of SCAs.展开更多
AIM:To evaluate the precision of digital intraocular pressure(IOP)measurement in silicone oil(SO)filled eyes during vitrectomy.METHODS:This is a retrospective,single-blind study.Patients who were diagnosed with retina...AIM:To evaluate the precision of digital intraocular pressure(IOP)measurement in silicone oil(SO)filled eyes during vitrectomy.METHODS:This is a retrospective,single-blind study.Patients who were diagnosed with retinal detachment and scheduled for vitrectomy with SO injection were consecutively enrolled.During the vitrectomy,IOP was digitally measured and then by a rebound tonometer(Icare PRO).The rebound tonometer readings were masked to the surgeons.The digitally measured IOP and that of rebound tonometer were compared,and the inter-methods agreement was assessed.The absolute deviation in IOP values between these two methods(△IOP)was also calculated,and correlations between△IOP and refractive status,lens status and levels of surgeons’experience were analyzed.RESULTS:A total of 131 patients(131 eyes)were recruited,with a mean age of 51.0±16.1 y.There was no significant difference in IOPs between digital measurement and the rebound tonometer(15.6±4.3 vs 15.7±5.1 mm Hg;t=0.406,P=0.686).Intraclass correlation coefficients(ICC)analysis indicated a strong correlation between these two measurements(ICC=0.830,P<0.001).The mean△IOP was 2.0±1.9 mm Hg(range:0-12.8 mm Hg),with 98 eyes(74.8%)had the△IOP within 3 mm Hg.△IOP was found to be negatively correlated with levels of surgeons’experience(r=-0.183;P=0.037),but not with the refractive status or lens status of the patients(both P>0.05).CONCLUSION:For experienced surgeons,the digital IOP measurement may be an acceptable technique for IOP measurement in SO filled eyes during vitrectomy.However,its use by inexperienced surgeons should be taken with caution.展开更多
Acute stress concentration plays an important role in plaque rupture and may cause stroke or myocardial infarction.Quantitative evaluation of the relation between in vivo plaque stress and variations in blood pressure...Acute stress concentration plays an important role in plaque rupture and may cause stroke or myocardial infarction.Quantitative evaluation of the relation between in vivo plaque stress and variations in blood pressure and flow rates is valuable to optimize daily monitoring of the cardiovascular system for high-risk patients as well as to set a safe physical exercise intensity for better quality of life.In this study,we constructed an in vivo stress model for a human carotid bifurcation with atherosclerotic plaque,and analyzed the effects of blood pressure,flow rates,plaque stiffness,and stenosis on the elastic stress and fluid viscous stress around the plaque.According to the maximum values of the mechanical stress,we define a risk index to predict the risk level of plaque rupture under different exercise intensities.For a carotid bifurcation where the blood flow divides,the results suggest that the stenosis ratio determines the ratio of the contributions of elastic shear stress and viscous shear stress to plaque rupture.A n increase of the plaque stiffness enhances the maximum elastic shear stress in the plaque,indicating that a high-stiffness plaque is more prone to rupture for given stenosis ratio.High stress co-localization at the shoulder of plaques agrees with the region of plaque injury in clinical observations.It is demonstrated that,due to the stress-shield effect,the rupture risk of a high-stiffness plaque tends to decrease under high-stenosis conditions,suggesting the existence of a specific stenosis corresponding to the maximum risk.This study may help to complement risk stratification of vulnerable plaques in clinical practice and provides a stenosis mechanical property-specific guide for blood pressure control in cardiovascular health management.展开更多
Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding o...Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%.展开更多
This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made usi...This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made using the error and process input parameters in a closed loop system in order to obtain better controller performance for set-point change and load disturbances. This on-line tuning method reduces operator involvement and enhances the controller performance to a wide operating range. The hierarchical control scheme consists of an intelligent upper level supervisory fuzzy controller and a lower level direct fuzzy controller. The upper level controller provides a mechanism to the main goal of the system and the lower level controller delivers the solutions to a particular situation. The control algorithm for the proposed scheme has been developed and tested using an ARM7 microcontroller-based embedded target board for a nonlinear pressure process having dead time. To demonstrate the effectiveness, the results of the proposed hierarchical controller, fuzzy controller and conventional proportional-integral (PI) controller are analyzed. The results prove that the SHFC performance is better in terms of stability and robustness than the conventional control methods.展开更多
Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In thi...Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In this study, we try to find out the association between methods above and prognostic indicators.展开更多
In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic...In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.展开更多
基金supported by the Structures and Materials(S&M)Research Lab of Prince Sultan Universitysupport of Prince Sultan University in paying the article processing charges(APC)for this publication.
文摘When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.
基金The Project of the National Ministry of Industry and Information Technology[2020-0103-3-1-1]The Project of Beijing Science and technology“capital characteristics”[Z181100001718007]。
文摘Objective Current clinical evidence on the effects of home blood pressure telemonitoring(HBPT)on improving blood pressure control comes entirely from developed countries.Thus,we performed this randomized controlled trial to evaluate whether HBPT plus support(patient education and clinician remote hypertension management)improves blood pressure control more than usual care(UC)in the Chinese population.Methods This single-center,randomized controlled study was conducted in Beijing,China.Patients aged 30-75 years were eligible for enrolment if they had blood pressure[systolic(SBP)≥140 mmHg and/or diastolic(DBP)≥90 mmHg;or SBP≥130 mmHg and/or DBP≥80 mmHg with diabetes].We recruited 190 patients randomized to either the HBPT or the UC groups for 12 weeks.The primary endpoints were blood pressure reduction and the proportion of patients achieving the target blood pressure.Results Totally,172 patients completed the study,the HBPT plus support group(n=84),and the UC group(n=88).Patients in the plus support group showed a greater reduction in mean ambulatory blood pressure than those in the UC group.The plus support group had a significantly higher proportion of patients who achieved the target blood pressure and maintained a dipper blood pressure pattern at the12th week of follow-up.Additionally,the patients in the plus support group showed lower blood pressure variability and higher drug adherence than those in the UC group.Conclusion HBPT plus additional support results in greater blood pressure reduction,better blood pressure control,a higher proportion of dipper blood pressure patterns,lower blood pressure variability,and higher drug adherence than UC.The development of telemedicine may be the cornerstone of hypertension management in primary care.
文摘Introduction: The management of hypertension is mostly based on pharmacotherapy and hygienic and dietary measures (HDMs) for which little data is available in Cameroon. The concern to improve the quality of life of hypertensive patients led us to study the knowledge, compliance and effect of HDMs among Cameroonian hypertensive patients. Methods: This was a cross-sectional study carried out at the Douala General Hospital;the census of patients was carried out from 05 March to 10 May 2018. The data evaluated were knowledge and compliance with HDMs with an inference of their effect on blood pressure control. Results: We recruited 330 participants at mean age of 60 ± 11 years, 37.9% men;57.3% with blood pressure (BP) controlled. Out of 330 subjects, 308 (93.3%) who had been educated about dietary health measures for hypertension were assessed on knowledge, compliance and effect of these measures against 22 (6.7%) who had never heard about them. Around 85.7% of participants had good knowledge of HDMs and 78.9% had good compliance with them. There was no statistically significant influence of knowledge and compliance with HDMs on blood pressure control. Conclusion: The level of knowledge and adherence to HDMs of hypertensive patients at the Douala General Hospital was appreciable. It is however appropriate for physicians to intensify patient education on HDMs and BP control.
文摘Introduction: Ambulatory Blood Pressure Measurement (ABPM) is a non- invasive examination recommended for subjects at high cardiovascular risk, and those requiring a nocturnal drop in BP such as elderly and obese subjects, those with secondary hypertension or resistant, diabetics, subjects with metabolic syndrome or sleep apnea syndrome. The objective of this study was to evaluate the contribution of ABPM in the diagnosis and evaluation of the level of control of hypertension under treatment at the Bel Air international clinic. Materials and Methods: This is a retrospective, cross-sectional and descriptive study, carried out at the Bel Air International Clinic in Conakry (Guinea) between January 2019 and November 30, 2022. It included a consecutive series of 180 consenting patients recruited through an ambulatory measurement of 24-hour blood pressure from a FUGADA brand device. Results: We collected 180 patients, with a male predominance (sex-ratio M/F = 2.46). The mean age of the patients was 48.48 ± 14.23 years. The most represented age group was that of 32 to 42 years with 50 cases (27.8%) followed by that of 43 to 52 years with 42 cases or 23.3%. The indication was for diagnostic purposes in 106 cases 58.9%, the therapeutic evaluation in 58 patients (32.2%). The examination was prescribed by a cardiologist in 98 cases (54.4%), a general practitioner in 71 cases (39.4%), a neurologist in 11 cases (6.1%). In the therapeutic evaluation, high blood pressure was controlled in 24 patients (13.3%) and uncontrolled in 34 cases (18.9%). In the diagnostic indication, high blood pressure was confirmed in 79 cases (43.9%) with a statistically significant link (Chi2</sup> = 4.57 and p-value = 0.032). The nycthemeral mean was 187.27 ± 26.22 mmHg for systolic blood pressure (SBP) and 110.37 ± 19.06 mmHg for diastolic blood pressure (DBP), during the day, 151.64 ± 21.45 mmHg for SBP and 71.59 ± 8.67 mmHg for diastolic blood pressure. During the study 65 patients (36.1%) were identified as dippers and 115 patients (63.9%) were no-dipping. The antihypertensive protocol used was monotherapy in 68 cases (37.8%), dual therapy in 46 cases (25.6%), triple therapy in 17 cases (9.4%). However 39 patients or 21.7% were not taking any antihypertensive. Conclusion: This preliminary study, despite the modest sample size, showed the importance of ABPM as a tool for diagnosis, monitoring of hypertensive patients and therapeutic adaptation. A large-scale national study would be necessary for the rational use of ambulatory blood pressure measurement in our context in order to improve the management of hypertensive patients.
文摘Objective:To explore the risk factors of diabetic nephropathy and its correlation with blood pressure control.Methods:A retrospective analysis of 80 patients with diabetic nephropathy(diabetic nephropathy group)and another 80 patients with diabetes(diabetic group)who were admitted to the Department of Nephrology and Endocrinology at our hospital from October 2021 to October 2022 was conducted.The general data of the two groups were compared,the influencing factors associated with the two groups were analyzed unilaterally,and unconditional dichotomous logistic regression was performed to analyze the influencing factors in patients with diabetic nephropathy.Results:There were no significant differences in high-density lipoprotein,systolic blood pressure,diastolic blood pressure,and creatinine between the two groups(P>0.05);however,compared with the diabetic group,the DN group had significantly elevated glycated hemoglobin,low-density lipoprotein,24-h urine protein,insulin resistance,and diabetes duration≥10 years(P<0.05).Conclusion:The clinical research on the correlation between the incidence of hypertension and the control of blood pressure in patients with diabetic nephropathy should be strengthened in order to formulate reasonable and feasible treatment plans.
基金The authors are grateful for the financial support from the National Natural Science Foundation of China(No.51827901&No.52274133)the Program for Guangdong Introducing Innovative and Enterpreneurial Teams(No.2019ZT08G315)the Shenzhen National Science Fund for Distinguished Young Scholars(RCJC20210706091948015).
文摘In-situ pressure-preserved coring(IPP-Coring)is considered to be the most reliable and efficient method for the identification of the scale of oil and gas resources.During IPP-Coring,because the rotation behavior of the pressure controller valve cover in different medium environments is unclear,interference between the valve cover and inner pipe may occur and negatively affect the IPP-Coring success rate.To address this issue,we conducted a series of indoor experiments employing a high-speed camera to gain greater insights into the valve cover rotation behavior in different medium environments,e.g.,air,water,and simulated drilling fluids.The results indicated that the variation in the valve cover rotation angle in the air and fluid environments can be described by a one-phase exponential decay function with a constant time parameter and by biphasic dose response function,respectively.The rotation behavior in the fluid environments exhibited distinct elastic and gravitational acceleration zones.In the fluid environments,the density clearly impacted the valve cover closing time and rotation behavior,whereas the effect of viscosity was very slight.This can be attributed to the negligible influence of the fluid viscosity on the drag coefficient found in this study;meanwhile,the density can increase the buoyancy and the time period during which the valve cover experienced a high drag coefficient.Considering these results,control schemes for the valve cover rotation behavior during IPP-Coring were proposed for different layers and geological conditions in which the different drilling fluids should be used,e.g.,the use of a high-density valve cover in high-pore pressure layers.
基金supported in part by the National Natural Science Foundation of China (Grant 81370438)the SJTU Medical-Engineering Cross-cutting Research Project (Grant YG2015MS53)supported by the Hui-Chun Chin and Tsung-Dao Lee Chinese Undergraduate Research Program Endowment
文摘An inflatable cuff wrapped around the upper arm is widely used in noninvasive blood pressure measurement.However, the mechanical interaction between cuff and arm tissues, a factor that potentially affects the accuracy of noninvasive blood pressure measurement, remains rarely addressed. In the present study, finite element(FE) models were constructed to quantify intra-arm stresses generated by cuff compression, aiming to provide some theoretical evidence for identifying factors of importance for blood pressure measurement or explaining clinical observations. Obtained results showed that the simulated tissue stresses were highly sensitive to the distribution of cuff pressure on the arm surface and the contact condition between muscle and bone. In contrast, the magnitude of cuff pressure and small variations in elastic properties of arm soft tissues had little influence on the efficiency of pressure transmission in arm tissues. In particular, it was found that a thickened subcutaneous fat layer in obese subjects significantly reduced the effective pressure transmitted to the brachial artery, which may explain why blood pressure overestimation occurs more frequently in obese subjects in noninvasive blood pressure measurement.
基金supported by National Natural Science Foundation of China (Grant No. 50775199)National Hi-tech Research and Development Program of China (863 Program,Grant No. 2008AA042703)
文摘Water-assisted injection molding(WAIM),a newly developed fluid-assisted injection molding technology has drawn more and more attentions for the energy saving,short cooling circle time and high quality of products.Existing research for the process of WAIM has shown that the pressure control of the injecting water is mostly important for the WAIM.However,the proportional pressure control for the WAIM system is quite complex due to the existence of nonlinearities in the water hydraulic system.In order to achieve better pressure control performance of the injecting water to meet the requirements of the WAIM,the proportional pressure control of the WAIM system is investigated both numerically and experimentally.A newly designed water hydraulic system for WAIM is first modeled in AMEsim environment,the load characteristics and the nonlinearities of water hydraulic system are both considered,then the main factors affecting the injecting pressure and load flow rate are extensively studied.Meanwhile,an open-loop model-based compensation control strategy is employed to regulate the water injection pressure and a feedback proportional integrator controller is further adopted to achieve better control performance.In order to verify the AMEsim simulation results WAIM experiment for particular Acrylonitrile Butadiene Styrene(ABS) parts is implemented and the measured experimental data including injecting pressure and flow rate results are compared with the simulation.The good coincidence between experiment and simulation shows that the AMEsim model is accurate,and the tracking performance of the load pressure indicates that the proposed control strategy is effective for the proportional pressure control of the nonlinear WAIM system.The proposed proportional pressure control strategy and the conclusions drawn from simulation and experiment contribute to the application of water hydraulic proportional control and WAIM technology.
基金National Natural Science Foundation of China (No.81170851)Capital Project of the Transfer of Scientific and Technological Achievements in Research Institutes of Sichuan Province, China (2009 Chuan fiscal teach [2009] No.36)Sichuan Provincial Health Department Scientific Research Project, China (No.100474)
文摘AIM: To train Tibetan monkey (Macaca thibetana) for intraocular pressure (IOP) measurement in conscious state and obtain normal IOP in conscious Tibetan Macaque. METHODS: The training was based on award-conditioned behavior. Food stimulation and human-animal interaction were used in this training. RESULTS: Trained Tibetan monkeys calmly accepted IOP measurement by the TonoVete (R) rebound tonometer without sedation or anesthesia and their IOP values were similar to other primates. CONCLUSION: Human-cultivated Thibetan monkeys are tamable, and can be used for biomedical research such as ophthalmic research without anesthesia.
基金Project supported by the National Natural Science Foundation for Distinguished Young Scholars,China(Grant No.51425505)the National Natural Science Foundation of China(Grant No.61471324)+1 种基金the Program for the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi Province,China(Grant No.2013-077)the Graduate Students Outstanding Innovation Project of Shanxi Province,China(Grant No.20143020)
文摘In this paper, a novel antenna is proposed for high-temperature testing, which can make the high-temperature pressure characteristics of a wireless passive ceramic pressure sensor demonstrated at up to a temperature of 600℃. The design parameters of the antenna are similar to those of the sensor, which will increase the coupling strength between the sensor and testing antenna. The antenna is fabricated in thick film integrated technology, and the properties of the alumina ceramic and silver ensure the feasibility of the antenna in high-temperature environments. The sensor, coupled with the ceramic antenna, is investigated using a high-temperature pressure testing platform. The experimental measurement results show that the pressure signal in a harsh environment can be detected by the frequency diversity of the sensor.
基金Supported by the National High Technology Research and Development Program of China(863 Program)(2012AA110903)Jilin Key Scientific and Technological Project(20170204085GX)Jilin Industrial Technology Innovation Strategic Alliance Program(20150309013GX)
文摘In this paper the control mechanism of solenoid valve is analyzed,which shows the solenoid valve control is actually the control of coil current.The response characteristic of coil current is related to coil inductance and resistance.The coil resistance is influenced greatly by the ambient temperature and the self-heating of coil,which affects the control precision of coil current.First,considering the heat dissipation mode of coil,the coil temperature model is established from the perspective of heat conduction,and a temperature compensation algorithm for hydraulic system pressure control is put forward.Then the hardware-in-the-loop testbed is set up by using the dSPACE platform,carrying out wheel cylinder pressurization tests with inlet valve fully opened at-40℃ and 20℃,and testing the actual pressure of wheel cylinder with the target pressures at-40℃ and 6 000 kPa/s(pressurization rate).The results show that the pressure control temperature compensation algorithm proposed in this paper accurately corrects the influence of resistance temperature drift on the response accuracy of wheel cylinder pressure.After the correction,the pressure difference is less than 500 kPa,which can meet the control accuracy requirements of solenoid valve,enriching the linear control characteristic of solenoid valve.
文摘It is very important to maintain the level of mean arterial pressure (MAP). The MAP control is applied in many clinical situations, including limiting bleeding during cardiac surgery and promoting healing for patient' s post-surgery. This paper presents a fuzzy controller-based multiple-model adaptive control system for postoperative blood pressure management. Multiple-model adaptive control (MMAC) algorithm is used to identify the patient model, and it is a feasible system identification method even in the presence of large noise. Fuzzy control (FC) method is used to design controller bank. Each fuzzy controller in the controller bank is in fact a nonlinear proportional-integral (PI) controller,whose proportional gain and integral gain are adjusted continuously according to error and rate of change of error of the plant output, resulting in better dynamic and stable control performance than the regular PI controller, especially when a nonlinear process is involved. For demonstration, a nonlinear, pulsatile-flow patient model is used for simulation, and the results show that the adaptive control system can effectively handle the changes in patient's dynamics and provide satisfactory performance in regulation of blood pressure of hypertension patients.
基金This study was supported in part by the Ministry of Science and Technology MOST 108-2221-E-150-022-MY3 and Taiwan Ocean University.
文摘This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography(PPG)sensors and a deep learning(DL)that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators.The proposed platform measured the signal changes in PPG and converted them into physiological indicators,such as pulse transit time(PTT),pulse wave velocity(PWV),perfusion index(PI)and heart rate(HR);these indicators were then fed into the DL to calculate blood pressure.The hardware of the experiment comprised 2 PPG components(i.e.,Raspberry Pi 3 Model B and analog-todigital converter[MCP3008]),which were connected using a serial peripheral interface.The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure(SBP),diastolic blood pressure(DBP)and mean arterial pressure(MAP).To increase the robustness of the DL model,this study input data of 100 Asian participants into the training database,including those with and without cardiovascular disease,each with a proportion of approximately 50%.The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17±0.46 mmHg.The mean absolute error and standard deviation of DBP was 0.27±0.52 mmHg.The mean absolute error and standard deviation of MAP was 0.16±0.40 mmHg.
基金funded by the State Key Research Development Program of China(No.2018YFC0604400)the National Science Foundation of China(Nos.51874068,52074062)+2 种基金the Fundamental Research Funds for the Central Universities(Nos.N2001003,N160107001,N180701016,N182608003,N2001001)the 111 Project(No.B17009)The authors also acknowledge Nazarbayev University for funding the research through its Collaborative Research Program(No.OPCRP2020014).
文摘Static cracking agent(SCA)is actively investigated as an alternative to explosive blasting for rock breakage due to its immense expansion property.SCA can eliminate the negative effects of shock,noise and harmful gases encountered in explosive blasting processes.Accurate measurement and deep understanding of the expansive properties of SCAs are important in their industrial application.An improved outer pipe method(OPM),termed the upper end surface method(UESM),is proposed in this paper to overcome the shortcomings of the OPM in the expansive pressure measurement of SCAs.Numerical simulation is used to proof the concept and a mathematical model established to relate the internal pressure and the radial strains at different positions in the upper end surface method test equipment.The new equipment is calibrated using oil pressure and strain measurements.The calibrated equipment is then used to measure the expansion pressure of SCA at three different water contents to proof its potential.The differences in the measurements with OPM and UESM at three different moisture contents are less than 4%.The experimental results confirm the accuracy and applicability of the more user friendly and less expensive UESM in the measurement of the expansive pressures of SCAs.
基金Supported by the National Natural Science Foundation of China(No.81670851)。
文摘AIM:To evaluate the precision of digital intraocular pressure(IOP)measurement in silicone oil(SO)filled eyes during vitrectomy.METHODS:This is a retrospective,single-blind study.Patients who were diagnosed with retinal detachment and scheduled for vitrectomy with SO injection were consecutively enrolled.During the vitrectomy,IOP was digitally measured and then by a rebound tonometer(Icare PRO).The rebound tonometer readings were masked to the surgeons.The digitally measured IOP and that of rebound tonometer were compared,and the inter-methods agreement was assessed.The absolute deviation in IOP values between these two methods(△IOP)was also calculated,and correlations between△IOP and refractive status,lens status and levels of surgeons’experience were analyzed.RESULTS:A total of 131 patients(131 eyes)were recruited,with a mean age of 51.0±16.1 y.There was no significant difference in IOPs between digital measurement and the rebound tonometer(15.6±4.3 vs 15.7±5.1 mm Hg;t=0.406,P=0.686).Intraclass correlation coefficients(ICC)analysis indicated a strong correlation between these two measurements(ICC=0.830,P<0.001).The mean△IOP was 2.0±1.9 mm Hg(range:0-12.8 mm Hg),with 98 eyes(74.8%)had the△IOP within 3 mm Hg.△IOP was found to be negatively correlated with levels of surgeons’experience(r=-0.183;P=0.037),but not with the refractive status or lens status of the patients(both P>0.05).CONCLUSION:For experienced surgeons,the digital IOP measurement may be an acceptable technique for IOP measurement in SO filled eyes during vitrectomy.However,its use by inexperienced surgeons should be taken with caution.
基金This work was supported by the National Key R&D Program of China(Grant 2017YFE0117100)the National Natural Science Foundation of China(Grants 11872040 and 11232010)+1 种基金the Outstanding Clinical Discipline Project of Shanghai Pudong(Grant PWYgy-2018-08)the Science and Technology Commission of Shanghai Municipality(Grant 18ZR1433900).
文摘Acute stress concentration plays an important role in plaque rupture and may cause stroke or myocardial infarction.Quantitative evaluation of the relation between in vivo plaque stress and variations in blood pressure and flow rates is valuable to optimize daily monitoring of the cardiovascular system for high-risk patients as well as to set a safe physical exercise intensity for better quality of life.In this study,we constructed an in vivo stress model for a human carotid bifurcation with atherosclerotic plaque,and analyzed the effects of blood pressure,flow rates,plaque stiffness,and stenosis on the elastic stress and fluid viscous stress around the plaque.According to the maximum values of the mechanical stress,we define a risk index to predict the risk level of plaque rupture under different exercise intensities.For a carotid bifurcation where the blood flow divides,the results suggest that the stenosis ratio determines the ratio of the contributions of elastic shear stress and viscous shear stress to plaque rupture.A n increase of the plaque stiffness enhances the maximum elastic shear stress in the plaque,indicating that a high-stiffness plaque is more prone to rupture for given stenosis ratio.High stress co-localization at the shoulder of plaques agrees with the region of plaque injury in clinical observations.It is demonstrated that,due to the stress-shield effect,the rupture risk of a high-stiffness plaque tends to decrease under high-stenosis conditions,suggesting the existence of a specific stenosis corresponding to the maximum risk.This study may help to complement risk stratification of vulnerable plaques in clinical practice and provides a stenosis mechanical property-specific guide for blood pressure control in cardiovascular health management.
基金The work of this paper is supported by the National Natural Science Foundation of China under Grant No.61572038,the Innovation Project Foundation NCUT.
文摘Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%.
文摘This paper describes a supervisory hierarchical fuzzy controller (SHFC) for regulating pressure in a real-time pilot pressure control system. The input scaling factor tuning of a direct expert controller is made using the error and process input parameters in a closed loop system in order to obtain better controller performance for set-point change and load disturbances. This on-line tuning method reduces operator involvement and enhances the controller performance to a wide operating range. The hierarchical control scheme consists of an intelligent upper level supervisory fuzzy controller and a lower level direct fuzzy controller. The upper level controller provides a mechanism to the main goal of the system and the lower level controller delivers the solutions to a particular situation. The control algorithm for the proposed scheme has been developed and tested using an ARM7 microcontroller-based embedded target board for a nonlinear pressure process having dead time. To demonstrate the effectiveness, the results of the proposed hierarchical controller, fuzzy controller and conventional proportional-integral (PI) controller are analyzed. The results prove that the SHFC performance is better in terms of stability and robustness than the conventional control methods.
文摘Objective In cerebral aneurysm clipping and embolization, blood pressure control and temporaryparent artery blocking are common methods to prevent aneurysm rupture. Their influence on the prognosis isuncertain. In this study, we try to find out the association between methods above and prognostic indicators.
文摘In this paper, we evaluate the difference between the first and second measurements of blood pressure (BP) when BP is measured twice using the results of 17,775 medical checkups. The two measurements for both systolic BP (SBP) and the diastolic BP (DBP) fluctuated a large amount even though they were measured at a short interval. The first measurements were 6.7 and 2.4 mmHg higher than the second ones for SBP and DBP, suggesting a white coat effect. Then, the factors that might affect the differences between the two measurements were analyzed by the regression models. For both SBP and DBP, the difference increased as the first measurement increased. Age, gender, BMI and alcohol consumption were other important factors affecting the difference. In the case of a typical male individual, the typical criteria for hypertension of 140/90, 160/100 and 180/110 mmHg criteria in the first measurement would correspond to 135/86, 150/94 and 165/102 mmHg in the second measurement. The necessity of developing accurate and cost-efficient BP measurement methods is strongly suggested.