期刊文献+
共找到5,349篇文章
< 1 2 250 >
每页显示 20 50 100
METHODS FOR CALCULATING SHELL-SIDE CONDENSATION HEAT TRANSFER AND PRESSURE DROP OF RODBAFFLE CONDENSER
1
作者 思勤 刘昌俊 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第1期93-97,共5页
1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The s... 1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The supporting-rod matrix creates an unobstructedflow path and makes the flow field in the shell-side of the heat exchangerpredominantly longitudinal bringing along flow-induced tube vibration in a cross flowheat-exchanger.With neither bundle cross flow form drag nor repeated flow reversal ef-fects being present,the shell-side pressure losses in Rodbaffle heat exchangers are low.Rodbaffle heat exchangers also offer an enhanced thermal performance. 展开更多
关键词 CONDENSATION heat transfer pressure drop Rodbaffle CONDENSER
下载PDF
Buckling Properties of Water-Drop-Shaped Pressure Hulls with Various Shape Indices Under Hydrostatic External Pressure
2
作者 DING Xiao-de ZHANG Jian +2 位作者 WANG Fang JIAO Hui-feng WANG Ming-lu 《China Ocean Engineering》 SCIE EI CSCD 2024年第1期1-17,共17页
The water-drop-shaped pressure hull has a good streamline,which has good application prospect in the underwater observatory.Therefore,this study conducted analytical,experimental and numerical investigation of the buc... The water-drop-shaped pressure hull has a good streamline,which has good application prospect in the underwater observatory.Therefore,this study conducted analytical,experimental and numerical investigation of the buckling properties of water-drop-shaped pressure hulls under hydrostatic pressure.A water-drop experiment was conducted to design water-drop-shaped pressure hulls with various shape indices.The critical loads for the water-drop-shaped pressure hulls were resolved by using Mushtari’s formula.Several numerical simulations including linear buckling analysis and nonlinear buckling analysis including eigenmode imperfections were performed.The results indicated that the critical loads resolved by Mushtari's formula were in good agreement with the linear buckling loads from the numerical simulations.This formula can be extended to estimate the buckling capacity of water-drop-shaped pressure hulls.In addition,three groups of pressure hulls were fabricated by using stereolithography,a rapid prototyping technique.Subsequently,three groups of the pressure hulls were subjected to ultrasonic measurements,optical scanning,hydrostatic testing and numerical analysis.The experimental results were consistent with the numerical results.The results indicate that the sharp end of the water-drop-shaped pressure hulls exhibited instability compared with the blunt end.This paper provides a new solution to the limitations of experimental studies on the water-drop-shaped pressure hulls as well as a new configuration and evaluation method for underwater observatories. 展开更多
关键词 BUCKLING pressure hull water drop underwater observatory
下载PDF
Evaluation of frictional pressure drop correlations for air-water and air-oil two-phase flow in pipeline-riser system
3
作者 Nai-Liang Li Bin Chen 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1305-1319,共15页
Accurate prediction of the frictional pressure drop is important for the design and operation of subsea oil and gas transporting system considering the length of the pipeline. The applicability of the correlations to ... Accurate prediction of the frictional pressure drop is important for the design and operation of subsea oil and gas transporting system considering the length of the pipeline. The applicability of the correlations to pipeline-riser flow needs evaluation since the flow condition in pipeline-riser is quite different from the original data where they were derived from. In the present study, a comprehensive evaluation of 24prevailing correlation in predicting frictional pressure drop is carried out based on experimentally measured data of air-water and air-oil two-phase flows in pipeline-riser. Experiments are performed in a system having different configuration of pipeline-riser with the inclination of the downcomer varied from-2°to-5°to investigated the effect of the elbow on the frictional pressure drop in the riser. The inlet gas velocity ranges from 0.03 to 6.2 m/s, and liquid velocity varies from 0.02 to 1.3 m/s. A total of885 experimental data points including 782 on air-water flows and 103 on air-oil flows are obtained and used to access the prediction ability of the correlations. Comparison of the predicted results with the measured data indicate that a majority of the investigated correlations under-predict the pressure drop on severe slugging. The result of this study highlights the requirement of new method considering the effect of pipe layout on the frictional pressure drop. 展开更多
关键词 Frictional pressure drop Pipeline-riser Gas-liquid two-phase flow Severe slugging CORRELATION
下载PDF
Numerical study of pressure drop for a new fibrous media model
4
作者 周斌 Paolo Tronville +1 位作者 Richard Rivers 张小松 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期311-315,共5页
An open-source computational fluid dynamics(CFD)code named OpenFOAM is used to validate the flow field characteristics(flow patterns and pressure drop)around a single cylinder.Results show that OpenFOAM is suitabl... An open-source computational fluid dynamics(CFD)code named OpenFOAM is used to validate the flow field characteristics(flow patterns and pressure drop)around a single cylinder.Results show that OpenFOAM is suitable for simulating the low Reynolds number flow and Shaw's analytical expression is one of the solutions to Stokes' paradox.Experiments are performed on fibrous media and OpenFOAM simulation is carried out using the Tronville-Rivers two-dimensional random fiber model in terms of the characteristics of pressure drop.It is shown that the Kuwabara model predicts the pressure drop of fibrous filter media more accurately than the Happel model,and the experimental pressure drop is between simulated pressure drops with both non-slip and full-slip boundaries on fiber surfaces. 展开更多
关键词 fibrous media diameter distribution pressure drop computational fluid dynamics simulation
下载PDF
Prediction of Pressure Drop of Slurry Flow in Pipeline by Hybrid Support Vector Regression and Genetic Algorithm Model 被引量:26
5
作者 S.K. Lahiri K.C. Ghanta 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第6期841-848,共8页
This paper describes a robust support vector regression (SVR) methodology, which can offer superior performance for important process engineering problems. The method incorporates hybrid support vector regression an... This paper describes a robust support vector regression (SVR) methodology, which can offer superior performance for important process engineering problems. The method incorporates hybrid support vector regression and genetic algorithm technique (SVR-GA) for efficient tuning of SVR meta-parameters. The algorithm has been applied for prediction of pressure drop of solid liquid slurry flow. A comparison with selected correlations in the lit- erature showed that the developed SVR correlation noticeably improved the prediction of pressure drop over a wide range of operating conditions, physical properties, and pipe diameters. 展开更多
关键词 support vector regression genetic algorithm slurry pressure drop
下载PDF
Measurement and Correlation of Pressure Drop for Gas-Liquid Two-phase Flow in Rectangular Microchannels 被引量:16
6
作者 MA Youguang JI Xiyan WANG Dongji FU Taotao ZHU Chunying 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第6期940-947,共8页
The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cr... The pressure drop of gas-liquid two-phase flow in microchannel is of fundamental importance in heat and mass transfer processes. In this work,the pressure drop of gas-liquid two-phase flow in horizontal rectangular cross-section microchannels was measured by a pressure differential transducer system. Water,ethanol and n-propanol were used as liquid phase to study the effects of capillary number on pressure drop;air was used as the gas phase. Four microchannels with various dimensions of 100 μm× 200 μm,100 μm× 400 μm,100 μm× 800 μm and 100 μm× 2000 μm(depth × width) were used for determining the influence of configuration on the pressure drop. Experimental results showed that in micro-scale,the capillary number also affected the pressure drop remarkably,and in spite of only one-fold difference in aspect ratio,the variation of pressure drop reached up to near three times under the same experimental conditions. Taking the effects of aspect ratio and surface tension into account,a modi-fied correlation for Chisholm parameter C in the Chisholm model was proposed for predicting the frictional multi-plier,and the predicted values by the proposed correlation showed a satisfactory agreement with experimental data. 展开更多
关键词 pressure drop rectangular cross-section microchannel surface tension configuration influence Chis-holm parameter C
下载PDF
A Calculation of Steady Pressure Drop and an Analysis of HT-7U CICC 被引量:6
7
作者 武玉 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第4期1395-1398,共4页
Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel inter... Under the condition of steady state, the pressure drop of coolant is mainly caused by friction along the cable. In the CICC (cable-in-conduit-conductor), helium flow within the conductor consists of two parallel interconnected tubes. The velocity distribution has some differece between the central channel and conductor space. The region of Reynolds number is from 103 to 106. This paper describes the calculation of pressure drop of HT-7U CICC at various mass flows. It is assumed that the coolant flows in two parallel, rough tubes during the calculation. 展开更多
关键词 HT-7U tokamak cable-in-conduit-conductor steady pressure drop calculation and analysis
下载PDF
Effect of Radial Resistance Gap on the Pressure Drop of a Compact Annular-Radial-Orifice Flow Magnetorheological Valve 被引量:4
8
作者 Guoliang Hu Jiawei Zhang +1 位作者 Mingke Liao Ruqi Ding 《Journal of Beijing Institute of Technology》 EI CAS 2018年第4期535-546,共12页
A compact annular-radial-orifice flow magnetorheological(MR)valve was developed to investigate the effects of radial resistance gap on pressure drop.The fluid flow paths of this proposed MR valve consist of a single a... A compact annular-radial-orifice flow magnetorheological(MR)valve was developed to investigate the effects of radial resistance gap on pressure drop.The fluid flow paths of this proposed MR valve consist of a single annular flow channel,a single radial flow channel and an orifice flow channel through structure design.The finite element modelling and simulation analysis of the MR valve was carried out using ANSYS/Emag software to investigate the changes of the magnetic flux density and yield stress along the fluid flow paths under the four different radial resistance gaps.Moreover,the experimental tests were also conducted to evaluate the pressure drop,showing that the proposed MR valve has significantly improved its pressure drop at 0.5 mm width of the radial resistance gap when the annular resistance gap is fixed at 1 mm. 展开更多
关键词 magnetorheological(MR)valve annular-radial-orifice flow pressure drop radial resistance gap finite element analysis
下载PDF
Flow pattern and pressure drop of gas-liquid two-phase swirl flow in a horizontal pipe 被引量:5
9
作者 RAO Yong-chao DING Bo-yang +2 位作者 WANG Shu-li WANG Zi-wen ZHOU Shi-dong 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第9期2528-2542,共15页
The gas-liquid two-phase swirl flow can increase the gas-liquid two-phase contact area and enhance the heat and mass transfer efficiency between gas and liquid.The swirl flow has important practical application value ... The gas-liquid two-phase swirl flow can increase the gas-liquid two-phase contact area and enhance the heat and mass transfer efficiency between gas and liquid.The swirl flow has important practical application value for promoting gas hydrate formation and ensuring the flow safe of natural gas hydrate slurry.The experimental section was made of plexiglass pipe and the experimental medium was air and water.The flow pattern of the gas-liquid two-phase swirl flow in the horizontal pipe was divided,according to a high-definition camera and the overall characteristics of the gas-liquid interface.The flow pattern map of the gas-liquid two-phase swirl flow in a horizontal pipe was studied.The influence of the flow velocity and vane parameters on pressure drop was investigated.Two types of gas-liquid two-phase swirl flow pressure drop models was established.The homogeneous-phase and split-phase pressure drop models have good prediction on swirl bubble flow,swirl dispersed flow,swirl annular flow and swirl stratified flow,and the predictive error band is not more than 20%. 展开更多
关键词 swirl flow two-phase flow flow pattern swirl number pressure drop
下载PDF
Research on Pressure Drop Performance of the Packing-Flotation Column 被引量:9
10
作者 LIU Jiong-tian ZHANG Min +1 位作者 LI Yan-feng LU Yang 《Journal of China University of Mining and Technology》 EI 2006年第4期389-392,共4页
A packing-flotation column was proposed to optimize the flotation environment A research system was es- tablished using a 100 mm diameter cyclonic micro-bubble flotation column to study fluid properties. Dry-plate and... A packing-flotation column was proposed to optimize the flotation environment A research system was es- tablished using a 100 mm diameter cyclonic micro-bubble flotation column to study fluid properties. Dry-plate and wet- plate pressure drops were studied and the corresponding pressure drop equations developed. The results show that the dry-plate pressure drop of the packing cyclonic micro-bubble flotation column is 10–15 times less than that of the chemical tower, which is principally shown in its relatively small resistance coefficient, ξ ≈0.0207. The wet-plate pressure drop is 2–3 times higher than that of the chemical tower, which is largely caused by the separation materials and characteristics of the equipment. With flotation, the greater the pressure drop, the better the flotation environment. 展开更多
关键词 sieve plate PACKING flotation column pressure drop
下载PDF
Clinical outcomes of combined flow-pressure drop measurements using newly developed diagnostic endpoint:Pressure drop coefficient in patients with coronary artery dysfunction 被引量:2
11
作者 Mohamed A Effat Srikara Viswanath Peelukhana Rupak K Banerjee 《World Journal of Cardiology》 CAS 2016年第3期283-292,共10页
AIM:To combine pressure and flow parameter, pressure drop coefficient(CDP) will result in better clinical outcomes in comparison to the fractional flow reserve(FFR) group. METHODS:To test this hypothesis, a comparison... AIM:To combine pressure and flow parameter, pressure drop coefficient(CDP) will result in better clinical outcomes in comparison to the fractional flow reserve(FFR) group. METHODS:To test this hypothesis, a comparison was made between the FFR < 0.75 and CDP > 27.9 groups in this study, for the major adverse cardiac events [major adverse cardiac events(MACE): Primary outcome] and patients’ quality of life(secondary outcome). Further, a comparison was also made between the survival curves for the FFR < 0.75 and CDP > 27.9 groups. Two-tailed χ~2 test proportions were performed for the comparison of primary and secondary outcomes. Kaplan-Meier survival analysis was performed to compare the survival curves of FFR < 0.75 and CDP > 27.9 groups(MedcalcV10.2, Mariakerke, Belgium). Results were considered statistically significant for P < 0.05. RESULTS: The primary outcomes(%MACE) in the FFR < 0.75 group(20%, 4 out of 20) was not statistically different(P = 0.24) from the %MACE occurring in CDP > 27.9 group(8.57%, 2 out of 35). Noteworthy is the reduction in the %MACE in the CDP > 27.9 group, in comparison to the FFR < 0.75 group. Further, the secondary outcomes were not statistically significant between the FFR < 0.75 and CDP > 27.9 groups. Survival analysis results suggest that the survival time for the CDP > 27.9 group(n = 35) is significantly higher(P = 0.048) in comparison to the survival time for the FFR < 0.75 group(n = 20). The results remained similar for a FFR = 0.80 cut-off. CONCLUSION: Based on the above, CDP could prove to be a better diagnostic end-point for clinical revascularization decision-making in the cardiac catheterization laboratories. 展开更多
关键词 pressure drop coefficient INTERVENTIONAL CARDIOLOGY Intermediate CORONARY STENOSIS
下载PDF
Delineation of epicardial stenosis in patients with microvascular disease using pressure drop coefficient:A pilot outcome study 被引量:2
12
作者 Ullhas Udaya Hebbar Mohamed A Effat +2 位作者 Srikara V Peelukhana Imran Arif Rupak K Banerjee 《World Journal of Cardiology》 CAS 2017年第12期813-821,共9页
AIM To investigate the patient-outcomes of newly developed pressure drop coefficient(CDP) in diagnosing epicardial stenosis(ES) in the presence of concomitant microvascular disease(MVD).METHODS Patients from our clini... AIM To investigate the patient-outcomes of newly developed pressure drop coefficient(CDP) in diagnosing epicardial stenosis(ES) in the presence of concomitant microvascular disease(MVD).METHODS Patients from our clinical trial were divided into two subgroups with:(1) cut-off of coronary flow reserve(CFR) < 2.0;and(2) diabetes.First,correlations were performed for both subgroups between CDP and hyperemic microvascular resistance(HMR),a diagnostic parameter for assessing the severity of MVD.Linear regression analysis was used for these correlations.Further,in each of the subgroups,comparisons were made between fractional flow reserve(FFR) < 0.75 and CDP > 27.9 groups for assessing major adverse cardiac events(MACE:Primary outcome).Comparisons were also made between the survival curves for FFR < 0.75 and CDP > 27.9 groups.Two tailed chi-squared and Fischer's exact tests were performed for comparison of the primary outcomes,and the log-rank test was used to compare the Kaplan-Meier survival curves.P < 0.05 for all tests was considered statistically significant.RESULTS Significant linear correlations were observed between CDP and HMR for both CFR < 2.0(r = 0.58,P < 0.001) and diabetic(r = 0.61,P < 0.001) patients.In the CFR < 2.0 subgroup,the %MACE(primary outcomes) for CDP > 27.9 group(7.7%,2/26) was lower than FFR < 0.75 group(3/14,21.4%);P = 0.21.Similarly,in the diabetic subgroup,the %MACE for CDP > 27.9 group(12.5%,2/16) was lower than FFR < 0.75 group(18.2%,2/11);P = 0.69.Survival analysis for CFR < 2.0 subgroup indicated better event-free survival for CDP > 27.9 group(n = 26) when compared with FFR < 0.75 group(n = 14);P = 0.10.Similarly,for the diabetic subgroup,CDP > 27.9 group(n = 16) showed higher survival times compared to FFR group(n = 11);P = 0.58.CONCLUSION CDP correlated significantly with HMR and resulted in better %MACE as well as survival rates in comparison to FFR.These positive trends demonstrate that CDP could be a potential diagnostic endpoint for delineating MVD with or without ES. 展开更多
关键词 Fractional flow reserve pressure drop coefficient MICROVASCULAR disease Intermediate coronary STENOSIS INTERVENTIONAL CARDIOLOGY
下载PDF
Analysis of MHD Pressure Drop in Liquid LiPb Flow in Chinese ITER DFLL-TBM with Insulating Coating 被引量:2
13
作者 陈红丽 周涛 王红艳 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第4期494-498,共5页
Magnetohydrodynamic (MHD) pressure drop in the Chinese Dual Functional Liquid Lithium-lead Test Blanket Module (DFLL-TBM) proposed for ITER is discussed in this paper. Electrical insulation between the coolant cha... Magnetohydrodynamic (MHD) pressure drop in the Chinese Dual Functional Liquid Lithium-lead Test Blanket Module (DFLL-TBM) proposed for ITER is discussed in this paper. Electrical insulation between the coolant channel surfaces and the liquid metal is required to reduce the MHD pressure drop to a manageable level. Insulation can be provided by a thin insulating coating, such as Al2O3, which can also serve as a tritium barrier layer, at the channel surfaces in contact with LiPb. The coating's effectiveness for reducing the MHD pressure drop is analysed through three-dimensional numerical simulation. A MHD-based commercial computational fluid dynamic (CFD) software FLUENT is used to simulate the LiPb flow. The effect on the MHD pressure drop due to cracks or faults in the coating layer is also considered. The insulating performance requirement for the coating material in DFLL-TBM design is proposed according to the analysis. 展开更多
关键词 magnetohydrodynamic (MHD) pressure drop insulating coating liquid metal lithium-lead
下载PDF
Pressure Drop of Liquid–Solid Two-Phase Flow in the Vertical Tube Bundle of a Cold-Model Circulating Fluidized Bed Evaporator 被引量:2
14
作者 Feng Jiang Siyao Lv +2 位作者 Guopeng Qi Xiaoling Chen Xiulun Li 《Transactions of Tianjin University》 EI CAS 2019年第6期618-630,共13页
A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distr... A cold-model vertical multi-tube circulating fluidized bed evaporator was designed and built to conduct a visualization study on the pressure drop of a liquid–solid two-phase flow and the corresponding particle distribution.Water and polyformaldehyde particle(POM)were used as the liquid and solid phases,respectively.The effects of operating parameters such as the amount of added particles,circulating flow rate,and particle size were systematically investigated.The results showed that the addition of the particles increased the pressure drop in the vertical tube bundle.The maximum pressure drop ratios were 18.65%,21.15%,18.00%,and 21.15%within the experimental range of the amount of added particles for POM1,POM2,POM3,and POM4,respectively.The pressure drop ratio basically decreased with the increase in the circulating flow rate but fluctuated with the increase in the amount of added particles and particle size.The difference in pressure drop ratio decreased with the increase in the circulating flow rate.As the amount of added particles increased,the difference in pressure drop ratio fluctuated at low circulating flow rate but basically decreased at high circulating flow rate.The pressure drop in the vertical tube bundle accounted for about 70%of the overall pressure drop in the up-flow heating chamber and was the main component of the overall pressure within the experimental range.Three-dimensional phase diagrams were established to display the variation ranges of the pressure drop and pressure drop ratio in the vertical tube bundle corresponding to the operating parameters.The research results can provide some reference for the application of the fluidized bed heat transfer technology in the industry. 展开更多
关键词 pressure drop Liquid-solid two-phase flow CIRCULATING fluidized bed EVAPORATOR VERTICAL tube BUNDLE Heat transfer enhancement FOULING prevention DESCALING
下载PDF
Experimental investigation on boiling heat transfer and pressure drop of R245fa in a horizontal micro-fin tube 被引量:3
15
作者 WANG Zhi-qi HE Ni +1 位作者 XIA Xiao-xia LIU Li-wen 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第11期3200-3212,共13页
An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characte... An experimental investigation on the boiling heat transfer and frictional pressure drop of R245fa in a 7 mm horizontal micro-fin tube was performed.The results show that in terms of flow boiling heat transfer characteristics,boiling heat transfer coefficient(HTC)increases with mass velocity of R245fa,while it decreases with the increment of saturation temperature and heat flux.With the increase of vapor quality,HTC has a maximum and the corresponding vapor quality is about 0.4,which varies with the operating conditions.When vapor quality is larger than the transition point,HTC can be promoted more remarkably at higher mass velocity or lower saturation temperature.Among the four selected correlations,KANDLIKAR correlation matches with 91.6%of experimental data within the deviation range of±25%,and the absolute mean deviation is 11.2%.Also,in terms of frictional pressure drop characteristics of flow boiling,the results of this study show that frictional pressure drop increases with mass velocity and heat flux of R245fa,while it decreases with the increment of saturation temperature.MULLER-STEINHAGEN-HECK correlation shows the best prediction accuracy for frictional pressure drop among the four widely used correlations.It covers 84.1%of experimental data within the deviation range of±20%,and the absolute mean deviation is 10.1%. 展开更多
关键词 boiling heat transfer frictional pressure drop prediction correlations micro-fin tube R245fa fluid
下载PDF
Preliminary Analysis of Liquid Metal MHD Pressure Drop in the Blanket for the FDS 被引量:1
16
作者 王红艳 吴宜灿 何晓雄 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第5期1497-1504,共8页
Preliminary analysis and calculation of liquid metal Li17Pb83 magnetohydrodynamic (MHD) pressure drop in the blanket for the FDS have been presented to evaluate the significance of MHD effects on the thermal-hydraulic... Preliminary analysis and calculation of liquid metal Li17Pb83 magnetohydrodynamic (MHD) pressure drop in the blanket for the FDS have been presented to evaluate the significance of MHD effects on the thermal-hydraulic design of the blanket. To decrease the liquid metal MHD pressure drop, Al2O3 is applied as an electronically insulated coating onto the inner surface of the ducts. The requirement for the insulated coating to reduce the additional leakage pressure drop caused by coating imperfections has been analyzed. Finally, the total liquid metal MHD pressure drop and magnetic pump power in the FDS blanket have been given. 展开更多
关键词 FUSION-DRIVEN sub-critical liquid metal MHD pressure drop
下载PDF
A pressure drop model of post-fracturing shut-in considering the effect of fracturing-fluid imbibition and oil replacement 被引量:2
17
作者 WANG Fei RUAN Yingqi +1 位作者 CHEN Qiaoyun ZHANG Shicheng 《Petroleum Exploration and Development》 CSCD 2021年第6期1440-1449,共10页
Since the production regime of shut-in after fracturing is generally adopted for wells in shale oil reservoir,a shut-in pressure drop model coupling wellbore-fracture network-reservoir oil-water two-phase flow has bee... Since the production regime of shut-in after fracturing is generally adopted for wells in shale oil reservoir,a shut-in pressure drop model coupling wellbore-fracture network-reservoir oil-water two-phase flow has been proposed.The model takes into account the effects of wellbore afterflow,fracture network channeling,and matrix imbibition and oil exchange after stop of pumping.The simulated log-log curve of pressure-drop derivative by the model presents W-shape,reflecting the oil-water displacement law between wellbore,fracture network and matrix,and is divided into eight main control flow stages according to the soaking time.In the initial stage of pressure drop,the afterflow dominates;in the early stage,the pressure drop is controlled by the cross-flow and leakoff of the fracture system,and the fractures close gradually;in the middle stage of pressure drop,matrix imbibition and oil exchange take dominance,and the fracturing fluid loss basically balances with oil replaced from matrix;the late stage of pressure drop is the reservoir boundary control stage,and the leakoff rate of fracturing-fluid and oil exchange rate decrease synchronously till zero.Finally,the fracture network parameters such as half-length of main fracture,main fracture conductivity and secondary fracture density were inversed by fitting the pressure drop data of five wells in Jimsar shale oil reservoir,and the water imbibition volume of matrix and the oil replacement volume in fracture were calculated by this model.The study results provide a theoretical basis for comprehensively evaluating the fracturing effect of shale oil hori-zontal wells and understanding the oil-water exchange law of shale reservoir after fracturing. 展开更多
关键词 shale oil hydraulic fracturing shut-in pressure drop imbibition oil replacement fracture network
下载PDF
Experimental Study on Heat Transfer and Pressure Drop of Micro-Sized Tube Heat Exchanger 被引量:2
18
作者 王秋香 戴传山 《Transactions of Tianjin University》 EI CAS 2014年第1期21-26,共6页
A micro-sized tube heat exchanger(MTHE) was fabricated, and its performance in heat transfer and pressure drop was experimentally studied. The single-phase forced convection heat transfer correlation on the sides of t... A micro-sized tube heat exchanger(MTHE) was fabricated, and its performance in heat transfer and pressure drop was experimentally studied. The single-phase forced convection heat transfer correlation on the sides of the MTHE tubes was proposed and compared with previous experimental data in the Reynolds number range of 500—1 800. The average deviation of the correlation in calculating the Nusselt number was about 6.59%. The entrance effect in the thermal entrance region was discussed. In the same range of Reynolds number, the pressure drop and friction coefficient were found to be considerably higher than those predicted by the conventional correlations. The product of friction factor and Reynolds number was also a constant, but much higher than the conventional. 展开更多
关键词 micro-sized tube heat exchanger heat transfer pressure drop entrance effect
下载PDF
Pressure Drop Measurements on Distillation Columns 被引量:1
19
作者 T.J. Cai M.R. Resetarits 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第5期779-783,共5页
Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop me... Pressure drops are of major importance for distillation/absorption columns. This paper mainly discusses how to correctly measure, interpret and use pressure drop data. The possible causes of incorrect pressure drop measurements are studied including the effects of pressure tap dimensions, locations, and vapor condensation etc. The effect of the static head of vapor on the pressure drop data and column pressures is evaluated. Variations of sectional pressure drops along the column are investigated based on the experimental data obtained from commercial size distillation columns at Fractionation Research, Inc. (FRI). For a packed column, it is found that the spacing between the liquid distributor and the top of the bed affects the overall pressure drop measurements, which is confirmed by a fundamental fluid dynamics analysis. 展开更多
关键词 DISTILLATION TRAY PACKING pressure drop hydraulics
下载PDF
Effect of 0.01%atropine eyedrops on intraocular pressure in schoolchildren:a randomized clinical trial 被引量:2
20
作者 Javaria Bukhari Shi-Fei Wei +9 位作者 Shi-Ming Li Wen-Zai An Jia-Ling Du Xin-Tong Liang Jia-He Gan Jia-Xin Tian Wei-Ling Bai Zhi-Ning Cai Lei Yin Ning-Li Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第9期1431-1436,共6页
·AIM:To assess the effect of 0.01%atropine eye drops on intraocular pressure(IOP)in myopic children.·METHODS:A placebo-controlled,double-masked,randomized study.Totally 220 children aged 6 to 12 y with myopi... ·AIM:To assess the effect of 0.01%atropine eye drops on intraocular pressure(IOP)in myopic children.·METHODS:A placebo-controlled,double-masked,randomized study.Totally 220 children aged 6 to 12 y with myopia ranging from-1.00 to-6.00 D in both eyes were enrolled.Children were randomized in a 1:1 ratio to either 0.01%atropine eye drops or a placebo group using generated random numbers.All participants underwent the examination of IOP and cycloplegic refraction at baseline,6 and 12 mo.The change of IOP and the proportion of subjects with increased IOP in atropine and placebo groups were compared.·RESULTS:Of 220 children,117 were boys(53.2%).A total of 159(72.3%)participants completed the follow-up at the 1-year study.At baseline,the mean IOP was 15.74 mm Hg(95%CI,15.13 to 16.34 mm Hg)for the 0.01%atropine group and 15.59 mm Hg(95%CI,15.00 to 16.19 mm Hg)for placebo group(mean difference,0.14 mm Hg;P=0.743)after adjusting for central corneal thickness at baseline.At one year follow-up,the mean change of IOP was 0.16 mm Hg(95%CI,-0.43 to 0.76 mm Hg)for the 0.01%atropine group and-0.11 mm Hg(95%CI,-0.71 to 0.50 mm Hg)for placebo group(mean difference,0.27 mm Hg;P=0.525)after adjusting for central corneal thickness.The 51.4%of children have increased IOP in the 0.01%atropine group,compared with 45.9%in the placebo group(P=0.511).·CONCLUSION:The 0.01%atropine eye drops do not significantly affect the risk of elevated IOP.It is relatively safer to use in the studies that try to minimize myopia progression.However,a further long-duration study is required to be validated. 展开更多
关键词 intraocular pressure 0.01%atropine eye drops myopic children
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部