Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, res...Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure.展开更多
In order to obtain appropriate spray pressure and enhance the spraying and dust removal efficiency, various factors including the dust characteristics, nozzle spraying angle, effective spraying range, water consumptio...In order to obtain appropriate spray pressure and enhance the spraying and dust removal efficiency, various factors including the dust characteristics, nozzle spraying angle, effective spraying range, water consumption and droplet size are taken into account. The dust characteristics from different mines and atomization parameters of different pressure nozzles were measured. It was found that the internal pressure of coal cutters and roadheaders should be kept at 2 MPa, which could ensure large droplet size, large spraying angle and low water consumption and hence realizing a large-area covering and capture for large particle dusts. However, the external spray pressure should be kept at 4 MPa for smaller droplet size and longer effective spraying range, leading to effective dust removal in the operator zone. The spray pressure of support moving, drawing opening, and stage loader on a fully mechanized caving face and stage loader on a fully mechanized driving face should be kept at 8 MPa, under which the nozzles have long effective spraying range, high water flow and small droplet size for the rapid capture of instantaneous, high-concentration and small size dust groups. From the applications on the caving and driving faces in the coal mines, it is indicated that the optimization of spray pressure in different spraying positions could effectively enhance dust removal efficiency. Selecting appropriate nozzles according to the dust characteristics at different positions is also favorable for dust removal efficiency. With the selected nozzles under optimal pressures, the removal rates of both total dust and respirable dust could reach over70%, showing a significant de-dusting effect.展开更多
Based on the numerical simulation analysis, structure parameters of the high pressure fuel pump and common rail as well as flow limiter are designed and the GD-1 high pressure common rail fuel injection system is self...Based on the numerical simulation analysis, structure parameters of the high pressure fuel pump and common rail as well as flow limiter are designed and the GD-1 high pressure common rail fuel injection system is self-developed. Fuel injection characteristics experiment is performed on the GD-1 system. And double-factor variance analysis is applied to investigate the influence of the rail pressure and injection pulse width on the consistency of fuel injection quantity, thus to test whether the design of structure parameters is sound accordingly. The results of experiment and test show that rail pressure and injection pulse width as well as their mutual-effect have no influence on the injection quantity consistency, which proves that the structure parameters design is successful and performance of GD-1 system is sound.展开更多
During the cold-chamber high pressure die casting(HPDC) process, samples were produced to investigate the microstructure characteristics of AM60B magnesium alloy. Special attention was paid to the effects of process p...During the cold-chamber high pressure die casting(HPDC) process, samples were produced to investigate the microstructure characteristics of AM60B magnesium alloy. Special attention was paid to the effects of process parameters on the morphology and distribution of externally solidified crystals(ESCs) in the microstructure of magnesium alloy die castings, such as slow shot phase plunger velocity, delay time of pouring and fast shot phase plunger velocity. On the basis of metallographic observation and quantitative statistics, it is concluded that a lower slow shot phase plunger velocity and a longer delay time of pouring both lead to an increment of the size and percentage of the ESCs, due to the fact that a longer holding time of the melt in the shot sleeve will cause a more severe loss of the superheat. The impingement of the melt flow on the ESCs is more intensive with a higher fast shot phase plunger velocity, in such case the ESCs reveal a more granular and roundish morphology and are dispersed throughout the cross section of the castings. Based on analysis of the filling and solidification processes of the melt during the HPDC process, reasonable explanations were proposed in terms of the nucleation, growth, remelting and fragmentation of the ESCs to interpret the effects of process parameters on the morphology and distribution of the ESCs in the microstructure of magnesium alloy die castings.展开更多
The most common apparatus used to investigate the load-deformation parameters of homogeneous fine-grained soils is a Casagrande-type oedometer. A typical Casagrande oedometer cell has an internal diameter of 76 mm and...The most common apparatus used to investigate the load-deformation parameters of homogeneous fine-grained soils is a Casagrande-type oedometer. A typical Casagrande oedometer cell has an internal diameter of 76 mm and a height of 19 mm.However, the dimensions of this kind of apparatus do not meet the requirements of some civil engineering applications like studying load-deformation characteristics of specimens with large-diameter particles such as granular materials or municipal solid waste materials. Therefore, it is decided to design and develop a large-scale oedometer with an internal diameter of 490 mm. The new apparatus provides the possibility to evaluate the load-deformation characteristics of soil specimens with different diameter to height ratios. The designed apparatus is able to measure the coefficient of lateral earth pressure at rest. The details and capabilities of the developed oedometer are provided and discussed. To study the performance and efficiency, a number of consolidation tests were performed on Firoozkoh No. 161 sand using the newly developed large scale oedometer made and also the 50 mm diameter Casagrande oedometer. Benchmark test results show that measured consolidation parameters by large scale oedometer are comparable to values measured by Casagrande type oedometer.展开更多
By using the technique of the split Hopkinson pressure bar( SHPB),impact tests at different stress wavelengths( 0. 8-2. 0 m) and strain rates( 20-120 s^(-1)) were conducted to study the dynamic mechanical prop...By using the technique of the split Hopkinson pressure bar( SHPB),impact tests at different stress wavelengths( 0. 8-2. 0 m) and strain rates( 20-120 s^(-1)) were conducted to study the dynamic mechanical properties and damage accumulation evolution lawof granite. Test results showthat the dynamic compressive strength and strain rate of granite have a significantly exponential correlation;the relationship between peak strain and strain rate is approximately linear,and the increase of wavelengths generally makes the level of peak strain uplift. The multiple-impacts test at a lowstrain rate indicates that at the same wavelength,the cumulative damage of granite shows an exponential increasing form with the increase of strain rate; when keeping the increase of strain rate constant and increasing the stress wavelength,the damage accumulation effect of granite is intensified and still shows an exponential increasing form; under the effect of multiple impacts,the damage development trend of granite is similar overall,but the increase rate is accelerating. Therefore the damage evolution model was established on the basis of the exponential function while the physical meaning of parameters in the model was determined. The model can reflect the effect of the wave parameters and multiple impacts. The validity of the model and the physical meaning of the parameters were verified by the test,which further offer a reference for correlational research and engineering application for the granite.展开更多
文摘Septic shock is a common critical condition, for which effective early fluid resuscitation is the therapeutic focus. According to the 2008 international guidelines for management of severe sepsis and septic shock, resuscitation should achieve a central venous pressure (CVP) of 8-12 mmHg within the first 6 h. However, it is still uncertain about the sensitivity and specificity of CVP in reflecting the cardiac preload. Ultrasonography is a simple, rapid, non-invasive, and repeatable method for the measurement of sensitivity and specificity of CVP and has thus gradually attracted the increasing attention of physicians. It was reported that ultrasonography can show the inferior vena cava diameter, respiratory variability index, and blood volume in patients with sepsis or heart failure.
基金support from the National Natural Science Foundation of China (Nos.U1261205, 51474139 and 51204103)the Science and Technology Development Plan of Shandong Province (No.2013GSF12004)the Excellent Young Scientific Talents Project of Shandong University of Science and Technology (No.2014JQJH106)
文摘In order to obtain appropriate spray pressure and enhance the spraying and dust removal efficiency, various factors including the dust characteristics, nozzle spraying angle, effective spraying range, water consumption and droplet size are taken into account. The dust characteristics from different mines and atomization parameters of different pressure nozzles were measured. It was found that the internal pressure of coal cutters and roadheaders should be kept at 2 MPa, which could ensure large droplet size, large spraying angle and low water consumption and hence realizing a large-area covering and capture for large particle dusts. However, the external spray pressure should be kept at 4 MPa for smaller droplet size and longer effective spraying range, leading to effective dust removal in the operator zone. The spray pressure of support moving, drawing opening, and stage loader on a fully mechanized caving face and stage loader on a fully mechanized driving face should be kept at 8 MPa, under which the nozzles have long effective spraying range, high water flow and small droplet size for the rapid capture of instantaneous, high-concentration and small size dust groups. From the applications on the caving and driving faces in the coal mines, it is indicated that the optimization of spray pressure in different spraying positions could effectively enhance dust removal efficiency. Selecting appropriate nozzles according to the dust characteristics at different positions is also favorable for dust removal efficiency. With the selected nozzles under optimal pressures, the removal rates of both total dust and respirable dust could reach over70%, showing a significant de-dusting effect.
文摘Based on the numerical simulation analysis, structure parameters of the high pressure fuel pump and common rail as well as flow limiter are designed and the GD-1 high pressure common rail fuel injection system is self-developed. Fuel injection characteristics experiment is performed on the GD-1 system. And double-factor variance analysis is applied to investigate the influence of the rail pressure and injection pulse width on the consistency of fuel injection quantity, thus to test whether the design of structure parameters is sound accordingly. The results of experiment and test show that rail pressure and injection pulse width as well as their mutual-effect have no influence on the injection quantity consistency, which proves that the structure parameters design is successful and performance of GD-1 system is sound.
基金financially supported by the Fundamental Research Funds for the Central Universities(WUT:2017IVA036)111 Project(B17034)State Key Laboratory of Materials Processing and Die&Mould Technology,Huazhong University of Science and Technology(P2018-003)
文摘During the cold-chamber high pressure die casting(HPDC) process, samples were produced to investigate the microstructure characteristics of AM60B magnesium alloy. Special attention was paid to the effects of process parameters on the morphology and distribution of externally solidified crystals(ESCs) in the microstructure of magnesium alloy die castings, such as slow shot phase plunger velocity, delay time of pouring and fast shot phase plunger velocity. On the basis of metallographic observation and quantitative statistics, it is concluded that a lower slow shot phase plunger velocity and a longer delay time of pouring both lead to an increment of the size and percentage of the ESCs, due to the fact that a longer holding time of the melt in the shot sleeve will cause a more severe loss of the superheat. The impingement of the melt flow on the ESCs is more intensive with a higher fast shot phase plunger velocity, in such case the ESCs reveal a more granular and roundish morphology and are dispersed throughout the cross section of the castings. Based on analysis of the filling and solidification processes of the melt during the HPDC process, reasonable explanations were proposed in terms of the nucleation, growth, remelting and fragmentation of the ESCs to interpret the effects of process parameters on the morphology and distribution of the ESCs in the microstructure of magnesium alloy die castings.
基金financial support provided by the Iran University of Science and Technology
文摘The most common apparatus used to investigate the load-deformation parameters of homogeneous fine-grained soils is a Casagrande-type oedometer. A typical Casagrande oedometer cell has an internal diameter of 76 mm and a height of 19 mm.However, the dimensions of this kind of apparatus do not meet the requirements of some civil engineering applications like studying load-deformation characteristics of specimens with large-diameter particles such as granular materials or municipal solid waste materials. Therefore, it is decided to design and develop a large-scale oedometer with an internal diameter of 490 mm. The new apparatus provides the possibility to evaluate the load-deformation characteristics of soil specimens with different diameter to height ratios. The designed apparatus is able to measure the coefficient of lateral earth pressure at rest. The details and capabilities of the developed oedometer are provided and discussed. To study the performance and efficiency, a number of consolidation tests were performed on Firoozkoh No. 161 sand using the newly developed large scale oedometer made and also the 50 mm diameter Casagrande oedometer. Benchmark test results show that measured consolidation parameters by large scale oedometer are comparable to values measured by Casagrande type oedometer.
基金Supported by the National Key Technologies Research&Development Program(2017YFC0804607)the National Key Basic Research Development Plan(973 Proect)(2014CB047000)
文摘By using the technique of the split Hopkinson pressure bar( SHPB),impact tests at different stress wavelengths( 0. 8-2. 0 m) and strain rates( 20-120 s^(-1)) were conducted to study the dynamic mechanical properties and damage accumulation evolution lawof granite. Test results showthat the dynamic compressive strength and strain rate of granite have a significantly exponential correlation;the relationship between peak strain and strain rate is approximately linear,and the increase of wavelengths generally makes the level of peak strain uplift. The multiple-impacts test at a lowstrain rate indicates that at the same wavelength,the cumulative damage of granite shows an exponential increasing form with the increase of strain rate; when keeping the increase of strain rate constant and increasing the stress wavelength,the damage accumulation effect of granite is intensified and still shows an exponential increasing form; under the effect of multiple impacts,the damage development trend of granite is similar overall,but the increase rate is accelerating. Therefore the damage evolution model was established on the basis of the exponential function while the physical meaning of parameters in the model was determined. The model can reflect the effect of the wave parameters and multiple impacts. The validity of the model and the physical meaning of the parameters were verified by the test,which further offer a reference for correlational research and engineering application for the granite.