Electric submersible pumps were widely used in agricultural fields,petroleum and various other industries. The pressure pulsation caused fatigue failure due to vibration in electric submersible pump and affects the li...Electric submersible pumps were widely used in agricultural fields,petroleum and various other industries. The pressure pulsation caused fatigue failure due to vibration in electric submersible pump and affects the life and performance of its system. The objective of this study was to experimentally investigate the characteristics of pressure pulsation which were generated at various stages of a multistage electric submersible pump during closed valve operation at different speeds. An electric submersible pump with five stages was selected for conducting experiments. A variable frequency drive( VFD)was used to operate the electric submersible pump at five different speed settings from 40 to 60 Hz. Piezoresistive pressure transducers were mounted at each stage of the electric submersible pump to capture the unsteady pressure signals. At each speed setting,the electric submersible pump was operated at the shut-off condition and the signals of unsteady pressure from all the five stages were captured. A fast fourier transformation( FFT) was carried out on the pressure signals to convert into frequency domain.From the spectra of pressure pulsation signals,the characteristics of pressure pulsation are obtained for each stage and for various speed settings which were then used to understand its variation with speed and stages.展开更多
In order to study the correlation between the internal flow noise of the centrifugal pump and the turbulent pressure pulsation,a single-stage single-suction centrifugal pump was used as the research object by the comb...In order to study the correlation between the internal flow noise of the centrifugal pump and the turbulent pressure pulsation,a single-stage single-suction centrifugal pump was used as the research object by the combination of numerical calculation and experiment.Based on the RNG k-?model and the N-S equation,the model pump was simulated numerically by CFD.A dipole sound source was extracted by the turbulent pulse action of the volute wall surface according to the FW-H equation.The acoustic field of the model pump was solved on the basis of the boundary element method,and the sound pressure distribution of the internal flow field under the action of the dipole sound source of the volute wall and the frequency response of the inlet and outlet fields were obtained.The results show that the distribution of hydrodynamic noise inside the centrifugal pump is related to the pressure pulsation,presenting obvious dipole distribution and disturbance at the tongue.The sound pressure value of the field is mainly concentrated in the blade passing frequency and double frequency,in which the blade passing frequency is the strongest,and the sound pressure value decreases obviously under other double frequency.The main frequency of hydrodynamic noise is the blade passing frequency.展开更多
文摘Electric submersible pumps were widely used in agricultural fields,petroleum and various other industries. The pressure pulsation caused fatigue failure due to vibration in electric submersible pump and affects the life and performance of its system. The objective of this study was to experimentally investigate the characteristics of pressure pulsation which were generated at various stages of a multistage electric submersible pump during closed valve operation at different speeds. An electric submersible pump with five stages was selected for conducting experiments. A variable frequency drive( VFD)was used to operate the electric submersible pump at five different speed settings from 40 to 60 Hz. Piezoresistive pressure transducers were mounted at each stage of the electric submersible pump to capture the unsteady pressure signals. At each speed setting,the electric submersible pump was operated at the shut-off condition and the signals of unsteady pressure from all the five stages were captured. A fast fourier transformation( FFT) was carried out on the pressure signals to convert into frequency domain.From the spectra of pressure pulsation signals,the characteristics of pressure pulsation are obtained for each stage and for various speed settings which were then used to understand its variation with speed and stages.
基金supported by the National Natural Science Foundation of China(No.51469013)。
文摘In order to study the correlation between the internal flow noise of the centrifugal pump and the turbulent pressure pulsation,a single-stage single-suction centrifugal pump was used as the research object by the combination of numerical calculation and experiment.Based on the RNG k-?model and the N-S equation,the model pump was simulated numerically by CFD.A dipole sound source was extracted by the turbulent pulse action of the volute wall surface according to the FW-H equation.The acoustic field of the model pump was solved on the basis of the boundary element method,and the sound pressure distribution of the internal flow field under the action of the dipole sound source of the volute wall and the frequency response of the inlet and outlet fields were obtained.The results show that the distribution of hydrodynamic noise inside the centrifugal pump is related to the pressure pulsation,presenting obvious dipole distribution and disturbance at the tongue.The sound pressure value of the field is mainly concentrated in the blade passing frequency and double frequency,in which the blade passing frequency is the strongest,and the sound pressure value decreases obviously under other double frequency.The main frequency of hydrodynamic noise is the blade passing frequency.