To investigate the clinical effect of modified closed negative pressure suction technique combined with flap transplantation on the treatment of deep chronic refractory wounds
1
作者 Zhihui Hou Mingjuan Gu 《Discussion of Clinical Cases》 2019年第1期11-14,共4页
Objective:To investigate the clinical effect of modified closed negative pressure suction technique combined with flap transplantation on the treatment of deep chronic refractory wounds.Methods:During March of 2015 to... Objective:To investigate the clinical effect of modified closed negative pressure suction technique combined with flap transplantation on the treatment of deep chronic refractory wounds.Methods:During March of 2015 to April of 2018,52 cases of patients with deep chronic refractory wounds were selected as research objects.They were divided into the control group and the treatment group by use of the random number table method,with 26 cases in each group.Among them,the control group was given conventional debridement combined with flap reconstruction,and the treatment group was treated with modified closed negative pressure suction technique combined with flap transplantation to observe the clinical effect.Results:(1)According to the analysis on the effect of flap transplantation,the excellent and good rate of the treatment group was 92.3%,and in the control group,it was 76.9%(p<0.05).(2)According to the statistics,the incidence of complications in the treatment group was lower than that in the control group(p<0.05).Conclusions:Modified closed negative pressure suction technique combined with flap transplantation has a good effect on the treatment of deep chronic refractory wounds with fewer complications. 展开更多
关键词 Modified closed negative pressure suction technique Flap transplantation Deep chronic refractory wounds
下载PDF
Lung Injury Resulting from Fluted Silastic Soft Drain Extraction under Negative Pressure Suction
2
作者 Susumu Isoda Tamizo Kimura +3 位作者 Kenji Nishimura Nozomu Yamanaka Shingo Nakamura Tadaaki Maehara 《Open Journal of Thoracic Surgery》 2013年第3期73-75,共3页
We experienced two cases of lung injury resulting from fluted silastic drain extraction under reservoir-generated negative pressure suction. In the first case, a 67-year-old man underwent coronary artery bypass grafti... We experienced two cases of lung injury resulting from fluted silastic drain extraction under reservoir-generated negative pressure suction. In the first case, a 67-year-old man underwent coronary artery bypass grafting. A 19 Fr BLAKE drain was placed at the pericardial cavity, the mediastinum, and the left thoracic cavity. All three drains were connected to J-VAC reservoirs. After removing the drains (which maintained the negative pressure), subcutaneous emphysema and hemopneumothorax occur. A trocar catheter was inserted. Bleeding and the air leak terminated within a day. In the second case, a 73-year-old man underwent aortic valve replacement. Right pneumothorax occurred after the removal of the pleural cavity drain, which maintained the negative pressure generated by the reservoir. We inserted a trocar catheter, and the air leak terminated within a day. We hypothesized that the reservoir-generated negative pressure causes the pleura to enter the groove of the drain and become damaged during extraction. We stopped using a reservoir to connect to the fluted silastic drain placed at the pleural cavity and removed the negative pressure when extracting the pleural cavity drain. Since implementing this change, we have not experienced a similar lung injury in more than 500 cardiac surgery patients. 展开更多
关键词 COMPLICATION EXTRACTION LUNG Injury negative pressure SILASTIC DRAIN
下载PDF
Negative pressure device-assisted autologous fat grafting: A case report
3
作者 Rao Fu Jiaqi Qin +2 位作者 Fangzhou Xie Xintao Wang Yun Xie 《Chinese Journal of Plastic and Reconstructive Surgery》 2024年第1期34-36,共3页
This report describes a novel technique for improving depressed scars using negative pressure suction-assisted autologous fat grafting.A 35-year-old woman presented with a 20-year history of bilateral central buttock ... This report describes a novel technique for improving depressed scars using negative pressure suction-assisted autologous fat grafting.A 35-year-old woman presented with a 20-year history of bilateral central buttock con-cavities,causing aesthetic concerns.To maximize fat graft survival and enhance tissue volume,we implemented intermittent negative pressure suction on the recipient area for one month preoperatively.The patient expressed satisfaction with the cosmetic outcome,and a three-month follow-up confirmed a significantly improved fat graft survival rate.This minimally invasive,cost-effective,and easily reproducible technique offers a promising clinical strategy for treating depressed scars. 展开更多
关键词 negative pressure Autologous fat grafting Depressed scars ADHESION
下载PDF
Value of negative pressure sealing drainage on wound healing of Gustilo IIIB and IIIC open fractures
4
作者 Bo Fang Yong-Sheng Wang +2 位作者 Wei Li Kai Ying Gang Zong 《World Journal of Clinical Cases》 SCIE 2024年第20期4199-4205,共7页
BACKGROUND Gustilo III fractures have a high incidence and are difficult to treat.Patients often experience difficulty in wound healing.Negative pressure drainage technology can help shorten wound healing time and has... BACKGROUND Gustilo III fractures have a high incidence and are difficult to treat.Patients often experience difficulty in wound healing.Negative pressure drainage technology can help shorten wound healing time and has positive value in improving patient prognosis.AIM To explore the clinical value of the negative pressure sealing drainage technique in wound healing of Gustilo IIIB and IIIC open fractures.METHODS Eighty patients with Gustilo IIIB and IIIC open fractures with skin and soft tissue injuries who were treated in the Second People’s Hospital of Dalian from March 2019 to December 2021 were selected as the research subjects.They were divided into a study group(n=40,healed with negative pressure closed drainage)and a control group(n=40,healed with conventional dressing changes)according to the variation in the healing they received.The efficacy of the clinical interventions,the variations in the regression indicators(time to wound healing,time to fracture healing,time to hospitalization),and the conversion and healing of bacterial wounds were compared 1-3 mo after the intervention.RESULTS The total effective rate of patients among the study group was 95.00%(38/40),which was notably higher than 75.00%(30/40)among the control group(P<0.05).The wound healing time,fracture healing time,and hospital stay of the patients in the study group was shorter than the control group(P<0.05).After the intervention,the negative bacterial culture at the wound site rate and wound healing rate of the patients among the study group increased compared to the control group(P<0.05).CONCLUSION Negative pressure sealing and drainage technology has a good therapeutic effect on patients with Gustilo IIIB and IIIC open fracture wounds with skin and soft tissue injury.It can notably enhance the wound healing rate and the negative rate of bacteria on the wound surface and help to speed up the recovery process of patients. 展开更多
关键词 negative pressure closed drainage Gustilo type III open fracture Wound healing Clinical outcome Research value
下载PDF
Effectiveness of negative pressure wound therapy in complex surgical treatment of necrotizing fasciitis of the upper limb
5
作者 Konstantin V Lipatov Arthur Asatryan +5 位作者 George Melkonyan Aleksandr D Kazantcev Ekaterina I Solov’eva Denis V Krivikhin Irina V Gorbacheva Urii E Cherkasov 《World Journal of Orthopedics》 2024年第11期1015-1022,共8页
BACKGROUND Necrotizing fasciitis(NF)of the upper extremities is a severe surgical pathology,and the incidence of this disease has been steadily increasing in recent decades.Surgical treatment is accompanied by the for... BACKGROUND Necrotizing fasciitis(NF)of the upper extremities is a severe surgical pathology,and the incidence of this disease has been steadily increasing in recent decades.Surgical treatment is accompanied by the formation of extensive wounds,which can be treated with significant difficulties.In recent years,negative pressure wound therapy(NPWT)has proven to be highly effective.It is also promising for the treatment of NF.AIM To explore the effectiveness of NPWT in the treatment of NF of the upper extremities.METHODS The results of the treatment of 36 patients with NF of the upper extremities in two groups(NPWT group and control group;2022−2023)were retrospectively analyzed.In the NPWT group,the NPWT method(120 mmHg;constant mode)was used after surgical treatment.The number of vacuum-assisted dressings in patients ranged from 1 to 3,depending on the dynamics of the wound process.The duration of fixation of one bandage was up to 2−3 d.In the control group,conventional methods of local wound treatment were used.The following indicators were analyzed:The treatment delay,the prevalence of inflammation,the microbial landscape,the number of debridements,the duration of wound preparation for surgical closure,and the nature of skin plastic surgery.RESULTS Most patients experienced a significant treatment delay[4 d,interquartile range(IQR):2–7 d],which led to the spread of the pathological process to the forearm and shoulder.The most common pathogens were Staphylococcus aureus(14;38.9%)and Streptococcus pyogenes(22;61.1%).The average number of debridements per patient was 5(IQR:3–7),with no difference between groups.The average time to prepare wounds for surgical closure was 11±4 d in the NPWT group and 29±10 d(P=0.00001)in the control group.In the NPWT group,the wounds were more often closed with local tissues(15;83.3%),and in the control group,split-thickness skin grafts were more often used(4;50%).CONCLUSION The predominant isolation of Staphylococcus aureus and/or Streptococcus pyogenes from the lesions allowed us to classify these patients as NF type II.Multiple debridement procedures have become a feature of this disease treatment.The use of NPWT has significantly reduced the time required to prepare wounds for surgical closure.Early closure of wounds allows for more frequent use of local tissue repair,which ensures better results.NPWT is a highly effective way to prepare wounds for early surgical closure in patients with upper extremity NF. 展开更多
关键词 Necrotizing fasciitis Upper limb negative pressure wound therapy Vacuum-assisted closure Surgical treatment
下载PDF
Micro-power negative pressure wound technique reduces risk of incision infection following loop ileostomy closure
6
作者 Deng-Yong Xu Bing-Jun Bai +4 位作者 Lina Shan Hui-Yan Wei Deng-Feng Lin Ya Wang Da Wang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期186-195,共10页
BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complic... BACKGROUND Prophylactic loop ileostomy is an effective way to reduce the clinical severity of anastomotic leakage following radical resection of rectal cancer.Incisional surgical site infection(SSI)is a common complication after ileostomy closure.AIM To evaluate the efficacy and safety of the micro-power negative pressure wound technique(MPNPWT)in preventing incisional SSI.METHODS This was a prospective,randomized controlled clinical trial conducted at a single center.A total of 101 consecutive patients who underwent ileostomy closure after rectal cancer surgery with a prophylactic ileostomy were enrolled from January 2019 to December 2021.Patients were randomly allocated into an MPNPWT group and a control group.The MPNPWT group underwent intermittent suturing of the surgical incision with 2-0 Prolene and was covered with a micro-power negative pressure dressing.The surgical outcomes were compared between the MPNPWT(n=50)and control(n=51)groups.Risk factors for incisional SSI were identified using logistic regression.RESULTS There were no differences in baseline characteristics between the MPNPWT(n=50)and control groups(n=51).The incisional SSI rate was significantly higher in the control group than in the MPNPWT group(15.7%vs 2.0%,P=0.031).However,MPNPWT did not affect other surgical outcomes,including intra-abdominal complications,operative time,and blood loss.Postoperative hospital stay length and hospitalization costs did not differ significantly between the two groups(P=0.069 and 0.843,respectively).None of the patients experienced adverse effects of MPNPWT,including skin allergy,dermatitis,and pain.MPNPWT also helped heal the infected incision.Our study indicated that MPNPWT was an independent protective factor[odds ratio(OR)=0.005,P=0.025)]and diabetes was a risk factor(OR=26.575,P=0.029)for incisional SSI.CONCLUSION MPNPWT is an effective and safe way to prevent incisional SSI after loop ileostomy closure. 展开更多
关键词 Micro-power negative pressure technique Ileostomy closure Incisional surgical site infection Infection prevention Postoperative incision
下载PDF
Comparison Study of Different Drainage Tube Diameters with Negative Pressure Suction after Valve Replacement Surgery
7
作者 Yanfang Wei Yuan Feng +1 位作者 Shusong Li Linqiang Li 《Open Journal of Nursing》 2024年第11期591-597,共7页
Objective: This study aims to compare the effects of different drainage tube diameters (22F vs. 26F) combined with negative pressure suction on patients after valve replacement surgery, including postoperative indicat... Objective: This study aims to compare the effects of different drainage tube diameters (22F vs. 26F) combined with negative pressure suction on patients after valve replacement surgery, including postoperative indicators and complications. Methods: A total of 104 patients undergoing valve replacement surgery were included and divided into a 22F group (45 patients) and a 26F group (59 patients). The basic characteristics, postoperative ICU stay duration, drainage duration, postoperative complications, and pain scores were compared between the two groups. All data were analyzed using SPSS statistical software, with p Results: There were no significant differences between the two groups in terms of age, sex, and underlying diseases. The ICU stay duration and drainage duration showed no significant differences (p > 0.05). The total drainage volume in the 22F group was significantly lower than that in the 26F group (225 vs. 380 ml, p = 0.035), and the pain scores on the third postoperative day were also significantly lower in the 22F group (p Conclusion: Compared to the 26F group, patients in the 22F group exhibited less postoperative drainage volume and lower pain scores, suggesting that the 22F drainage tube may have better clinical outcomes after valve replacement surgery. 展开更多
关键词 Valve Replacement Surgery Drainage Tube negative pressure suction Postoperative Complications Pain Score
下载PDF
Devastating complication of negative pressure wound therapy after deep inferior epigastric perforator free flap surgery:A case report 被引量:1
8
作者 SooA Lim Dong Yun Lee +3 位作者 BumSik Kim Jung Soo Yoon Yea Sik Han SuRak Eo 《World Journal of Clinical Cases》 SCIE 2023年第1期143-149,共7页
BACKGROUND Thermal injuries on free transferred or replanted tissues resulting from loss of sensibility are an infrequent occurrence.They require immediate and appropriate management before they progress to an irrever... BACKGROUND Thermal injuries on free transferred or replanted tissues resulting from loss of sensibility are an infrequent occurrence.They require immediate and appropriate management before they progress to an irreversible condition.Although negative pressure wound therapy(NPWT)can prevent wound progression by increasing microcirculation,the inappropriate application of NPWT on complicationthreatened transferred and replanted tissues can induce an adverse effect.CASE SUMMARY A 48-year-old woman who underwent immediate breast reconstruction with a deep inferior epigastric artery perforator free flap.While applying a heating pad directly to the flap site,she sustained a deep second to third-degree contact burn over 30%of the transferred flap on postoperative 7 d.As the necrotic changes had progressed,we applied an NPWT dressing over the burned area after en-bloc debridement of the transferred tissues on postoperative 21 d.After 4 d of NPWT application,the exposed fatty tissues of the flap changed to dry and browncolored necrotic tissues.Upon further debridement,we noted that the wound gradually reached total necrosis with a collapsed vascular pedicle of deep inferior epigastric artery.CONCLUSION Although NPWT has been shown to be successful for treating various wound types,the significant risk of NPWT application in short-lasting reconstructed flap wounds after thermal injury should be reminded. 展开更多
关键词 negative pressure Wound Therapy COMPLICATIONS Breast reconstruction Deep inferior epigastric artery perforator Free flap Burn injury Case report
下载PDF
Characteristics of the pressure profile in the accelerator on the RF negative ion source at ASIPP
9
作者 Mingshan Wu Luxiang Xu +2 位作者 Yanbo Zhou Lizhen Liang Yelong Zheng 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2023年第3期48-54,共7页
Neutral beam injection(NBI)systems based on negative hydrogen ion sources-rather than the positive ion sources that have typically been used to date-will be used in the future magnetically confined nuclear fusion expe... Neutral beam injection(NBI)systems based on negative hydrogen ion sources-rather than the positive ion sources that have typically been used to date-will be used in the future magnetically confined nuclear fusion experiments to heat the plasma.The collisions between the fast negative ions and neutral background gas result in a significant number of high-energy positive ions being produced in the acceleration area,and for the high-power long-pulse operation of NBI systems,this acceleration of positive ions back to the ion source creates heat load and material sputtering on the source backplate.This difficulty cannot be ignored,with the neutral gas density in the acceleration region having a significant impact on the flux density of the backstreaming positive ions.In the work reported here,the pressure gradient in the acceleration region was estimated using an ionization gauge and a straightforward 1D computation,and it was found that once gas traveled through the acceleration region,the pressure dropped by nearly one order of magnitude,with the largest pressure drop occurring at the plasma grid.The computation also revealed that the pressure drop in the grid gaps was substantially smaller than that in the grid apertures. 展开更多
关键词 pressure gradient negative ion source Aperture conductance Neutral beam injection
下载PDF
Application of apical negative pressure irrigation in the nonsurgical treatment of radicular cysts:A case report
10
作者 Gong-Pei Chen Yan-Zhen Zhang Dan-Hua Ling 《World Journal of Clinical Cases》 SCIE 2023年第15期3612-3618,共7页
BACKGROUND Radicular cysts are one of the most common odontogenic cystic lesions found in the jaw.Nonsurgical treatment of large radicular cysts is a topic of ongoing debate,and there is still no clear consensus on th... BACKGROUND Radicular cysts are one of the most common odontogenic cystic lesions found in the jaw.Nonsurgical treatment of large radicular cysts is a topic of ongoing debate,and there is still no clear consensus on the most effective therapies.The apical negative pressure irrigation system aspirates the cystic fluid and releases the static pressure in the radicular cyst,representing a minimally invasive approach for decompression.In this case,the radicular cyst was in close proximity to the mandibular nerve canal.We used nonsurgical endodontic treatment with a homemade apical negative pressure irrigation system and the prognosis was good.CASE SUMMARY A 27-year-old male presented to our Department of General Dentistry with complaints of pain in the mandibular right molar when chewing.The patient had no history of drug allergies or systemic disease.A multidisciplinary management approach was designed and included root canal retreatment with a homemade apical negative pressure irrigation system,deep margin elevation and prosthodontic treatment.According to a 1-year follow-up period,the patient showed a favorable outcome.CONCLUSION This report reveals that nonsurgical treatment with an apical negative pressure irrigation system may provide new insights into the treatment of radicular cysts. 展开更多
关键词 Apical negative pressure irrigation Radicular cyst Nonsurgical root canal treatment Case report
下载PDF
Application of negative pressure wound therapy after skin grafting in the treatment of skin cancer:A case report
11
作者 Gao-Shi Huang Ke-Chen Xu 《World Journal of Clinical Cases》 SCIE 2023年第28期6812-6816,共5页
BACKGROUND Skin cancer is a common malignant tumor in dermatology.A large area must be excised to ensure a negative incisal margin on huge frontotemporal skin cancer,and it is difficult to treat the wound.In the past,... BACKGROUND Skin cancer is a common malignant tumor in dermatology.A large area must be excised to ensure a negative incisal margin on huge frontotemporal skin cancer,and it is difficult to treat the wound.In the past,treatment with skin grafting and pressure dressing was easy to cause complications such as wound infections,subcutaneous effusion,skin necrosis,and contracture.Negative pressure wound therapy(NPWT)has been applied to treat huge frontotemporal skin cancer.CASE SUMMARY Herein,we report the case of a 92-year-old woman with huge frontotemporal skin cancer.The patient presented to the surgery department complaining of ruptured bleeding and pain in a right frontal mass.The tumor was pathologically diagnosed as highly differentiated squamous cell carcinoma.The patient underwent skin cancer surgery and skin grafting,after which NPWT was used.She did not experience a relapse during the three-year follow-up period.CONCLUSION NPWT is of great clinical value in the postoperative treatment of skin cancer.It is not only inexpensive but also can effectively reduce the risk of surgical effusion,infection,and flap necrosis. 展开更多
关键词 Skin cancer negative pressure wound therapy Skin grafting Case report
下载PDF
Utilizing Instilling Negative Pressure Wound Therapy with Vashe Wound Solution for an Infected Sternal Dehiscence: A Case Report
12
作者 Linnea T. Mauro Courtney M. Janowski +5 位作者 Mariah J. Janowski Adalberto C. Gonzalez Eugene J. Sidoti Luis G. Fernandez Paul J. Kim Marc R. Matthews 《Surgical Science》 2023年第3期231-239,共9页
Utilization of negative pressure wound therapy with instillation (NPWTi) for sternal dehiscence wounds secondary to sternal wound infection after surgery has become an accepted therapy. NPWTi accelerates wound healing... Utilization of negative pressure wound therapy with instillation (NPWTi) for sternal dehiscence wounds secondary to sternal wound infection after surgery has become an accepted therapy. NPWTi accelerates wound healing through macrostrain, microstrain, and cyclic fluid instillation. Wounds benefit from additional superficial infection control with the removal of microorganisms, the release of proinflammatory mediators, stimulation of angiogenesis, as well as mechanical debridement. However, very few cases of utilizing NPWTi in the treatment of sternal wound infections have been reported in the literature. This case study describes the use of NPWTi with hypochlorous acid for the treatment of a sternal wound infection. 展开更多
关键词 negative pressure Wound Therapy with Instillation NPWT NPWTi NPWT with Dwell Hypochlorous Acid Vashe Wound Solution Sternal Dehiscence
下载PDF
Management of Complex Wounds with Dermal Substitute Assisted by a Negative Pressure System
13
作者 Cuahutémoc Márquez Espriella Ruiz Garza Jorge Gerardo +18 位作者 Barbosa Villarreal Fernando Dávila Díaz Rodrigo Cuervo Vergara Marco Antonio Campollo López Ana Priscila Gutierrez Alvarez Mauricio Chama Naranjo Alfredo García Corral Jesús Ricardo Pérez Benítez Omar Alberto Pulido López Ricardo Alberto Jaimes Duran Edwing Michel Garibaldi Bernot Mauro Cortes Aguilar Carlos Manuel García Córdova Carlos Emiliano Camacho Rodriguez Hayah Camacho Rodriguez Hayah Martinez Villalobos Claudia Nallely Ochoa Contreras Erick Cesar Randall Cruz Soto Herrera Lozano Luis Arturo 《Modern Plastic Surgery》 2023年第4期95-105,共11页
Introduction: The standard treatment for complex wound care is autografting. The advent of dermal substitutes has provided a novel tool for the preparation of the bed to be grafted. However, most types of dermal matri... Introduction: The standard treatment for complex wound care is autografting. The advent of dermal substitutes has provided a novel tool for the preparation of the bed to be grafted. However, most types of dermal matrices require the application of a skin graft a second time. Currently, other strategies have been developed to improve the vascularization process, such as negative pressure wound therapy (NPWT), which has been reported to reduce the time required for vascular growth and dermal matrix integration and thus achieve a shorter waiting period for autologous graft application. The present study aims to evaluate the effectiveness and safety of dermal matrix management associated with NPWT in the treatment of complex wounds. Methods: Seven patients with a diagnosis of complex wounds were enrolled in this study between July 1, 2015, and June 31, 2016. After debridement and having an adequate wound bed, patients who met the criteria for the application of combined therapy were treated with dermal substitutes and a negative pressure system. The percentage of graft integration into the wound bed, complications, length of hospital stay, and duration of therapy were analyzed. Results: The mean age was 42.5 ± 16 (39 - 54) years old;three women and four men were included in the study. The approximate size of skin loss was 120.7 ± 75 cm<sup>2</sup> (25 - 250 cm<sup>2</sup>). The combined therapy of dermal matrix plus NPWT was instituted in all cases for a period of 14 days. There were no complications, with 100% graft integration in 6 of 7 cases. Patients were discharged after a mean hospital stay of 5.4 days. Conclusions: This study demonstrates that the utilization of combined dermal matrix plus NPWT therapy can be performed safely and effectively in patients with complex wounds with low complication rates and a short hospital stay. 展开更多
关键词 negative pressure Wound Therapy Complex Wound Dermal Matrix Wound Therapy
下载PDF
Bradycardia Secondary to Negative Suction Pressure Applied to Chest Drain
14
作者 Sanjeev Arya Shantanu Belwal +1 位作者 Sanjay Saxena Bhupesh Uniyal 《Case Reports in Clinical Medicine》 2019年第8期216-221,共6页
Positive pressure generated in peritoneal cavity by gas insufflation during laparoscopic procedures can cause hemodynamic instability. There are a few case reports suggesting similar occurrences during thoracoscopic p... Positive pressure generated in peritoneal cavity by gas insufflation during laparoscopic procedures can cause hemodynamic instability. There are a few case reports suggesting similar occurrences during thoracoscopic procedures as well. The mechanism behind the conditions above is explained to be due to stretch force applied to peritoneum and pleura which causes vagal stimulation. We wish to present a case where a high negative pressure applied to pleural cavity lead to treatment-resistant bradycardia. The possible mechanism behind this occurrence was traction pressure on pleura which triggered vagal activity. The bradycardia subsided on reducing or discontinuing negative suction pressure. To best of our knowledge this the first case report on bradycardia associated with high negative suction pressure applied to inter costal drain. 展开更多
关键词 CHEST DRAIN High negative pressure BRADYCARDIA PLEURAL TRACTION VAGAL Stimulation
下载PDF
On the dissipation of negative excess porewater pressure induced by excavation in soft soil 被引量:4
15
作者 李玉岐 应宏伟 谢康和 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第3期188-193,共6页
Unloading induces negative excess porewater pressure in soil mass around a foundation pit during excavation. In this work, the dissipation rule of negative excess porewater pressure after excavation was studied. Analy... Unloading induces negative excess porewater pressure in soil mass around a foundation pit during excavation. In this work, the dissipation rule of negative excess porewater pressure after excavation was studied. Analytical formulas for calculating the negative excess porewater pressures and the effective stresses were derived based on one-dimensional consolidation theory and Terzaghi’s effective stress principle. The influence of the dissipation of negative excess porewater pressure on earth pressure inside and outside a foundation pit and the stability of the retaining structure were analyzed through a numerical example. It was indicated that the dissipation of negative excess porewater pressure is harmful to the stability of the retaining structure and that rapid construction can make full use of the negative porewater pressure. 展开更多
关键词 negative excess porewater pressure Effective stress Earth pressure EXCAVATION
下载PDF
Asymmetric Fuzzy Control of a Positive and Negative Pneumatic Pressure Servo System 被引量:2
16
作者 Gang Yang Jing-Min Du +1 位作者 Xiao-Yun Fu Bao-Ren Li 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2017年第6期1438-1446,共9页
The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonline... The pneumatic pressure control systems have been used in some fields. However, the researches on pneumatic pressure control mainly focus on constant pressure regulation. Poor dynamic characteristics and strong nonlinearity of such systems limit its application in the field of pressure tracking control. In order to meet the demand of generating dynamic pressure signal in the application of the hardware-in-the-loop simulation of aerospace engineering, a positive and negative pneumatic pressure servo system is provided to implement dynamic adjustment of sealed chamber pressure. A mathematical model is established with simulation and experiment being implemented afterwards to discuss the characteristics of the system, which shows serious asymmetry in the process of charging and discharging. Based on the analysis of the system dynamics, a fuzzy proportional integral derivative (PID) controller with asymmetric fuzzy compensator is proposed. Different from conventional adjusting mecha- nisms employing the error and change in error of the controlled variable as input parameters, the current cham- ber pressure and charging or discharging state are chosen as inputs of the compensator, which improves adaptability. To verify the effectiveness and performance of the pro- posed controller, the comparison experiments tracking sinusoidal and square wave commands are conducted. Experimental results show that the proposed controller can obtain better dynamic performance and relatively consis- tent control performance across the scope of work (2-140 kPa). The research proposes a fuzzy control method to overcome asymmetry and enhance adaptability for the positive and negative pneumatic pressure servo system. 展开更多
关键词 Pneumatic pressure control system Positiveand negative pressure Asymmetric control Fuzzy control
下载PDF
Time-series analysis of the characteristic pressure fluctuations in a conical fluidized bed with negative pressure 被引量:1
17
作者 Sheng Fang Yanding Wei +2 位作者 Lei Fu Geng Tian Haibin Qu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第4期87-99,共13页
The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass an... The negative pressure conical fluidized bed is widely used in the pharmaceutical industry.In this study,experiments based on the negative pressure conical fluidized bed are carried out by changing the material mass and particle size.The pressure fluctuation signals are analyzed by the time and the frequency domain methods.A method for absolutely characterizing the degree of the energy concentration at the main frequency is proposed,where the calculation is to divide the original power spectrum by the average signal power.A phenomenon where the gas velocity curve temporarily stops growing is observed when the material mass is light,and the particle size is small.The standard deviation and kurtosis both rapidly change at the minimum fluidization velocity and thus can be used to determine the flow regime,and the variation rule of the kurtosis is independent of both the material mass and particle size.In the initial fluidization stage,the dominant pressure signal comes from the material movement;with the increase in the gas velocity,the power of a 2.5 Hz signal continues to increase.A method of dividing the main frequency by the average cycle frequency can conveniently determine the fluidized state,and a novel concept called stable fluidized zone proposed in this paper can be obtained.Controlling the gas velocity within the stable fluidized zone ensures that the fluidized bed consistently remains in a stable fluidized state. 展开更多
关键词 Conical fluidized bed negative pressure pressure fluctuation Time-series analysis Characteristic value Fluidized state
下载PDF
LIQUID-LIQUID PHASE EQUILIBRIUM OF POLYMER SOLUTIONS AND POLYMER BLENDS UNDER POSITIVE AND NEGATIVE PRESSURE
18
作者 Attila R.Imre 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2003年第2期241-250,共10页
In this paper we would like to give a brief review about the extensibility of the liquid-liquid locus into the negativepressure region. Negative pressure states are hardly explored; most researchers believe that the p... In this paper we would like to give a brief review about the extensibility of the liquid-liquid locus into the negativepressure region. Negative pressure states are hardly explored; most researchers believe that the pressure scale ends at p = 0.We would like to show that this is not true, the p = 0 point is not a special point for liquids, it can be 'easily' crossed. We aregoing to give a few example, where the extension of liquid-liquid locus for polymer blends and solutions below p = 0 givesus some interesting results, like the merging of UCST and LCST branches in weakly interacting polymer solutions or thereason why most UCST blends exhibit pressure induced immiscibility. Also, we will see what happens with the immiscibilityisland of aqueous polymer solutions when -- reaching the critical molar mass -- it 'disappears'. 展开更多
关键词 pressure negative pressure POLYMER SOLUBILITY Phase transition
下载PDF
Choice and management of negative pressure drainage in anterior cervical surgery
19
作者 Qi-Hang Su Kai Zhu +4 位作者 Yong-Chao Li Tao Chen Yan Zhang Jun Tan Song Guo 《World Journal of Clinical Cases》 SCIE 2020年第11期2201-2209,共9页
BACKGROUND Postoperative unobstructed drainage is an important measure for avoiding hematoma formation and preventing complications from anterior cervical surgery.AIM To discuss the characteristics and key points of c... BACKGROUND Postoperative unobstructed drainage is an important measure for avoiding hematoma formation and preventing complications from anterior cervical surgery.AIM To discuss the characteristics and key points of clinical management of two types of commonly used negative pressure drainage systems in clinical settings.METHODS Two types of commonly used silica gel negative pressure drainage balls and a type of gastrointestinal decompression apparatus were fully emptied and then injected with different amounts of water and air.Following this,the negative pressure values of the three devices were measured.Meanwhile,we undertook a retrospective analysis of the clinical data of 1328 patients who had been treated with different negative pressure drainage apparatuses during their anterior cervical surgery in our department between January 2007 and January 2018.RESULTS As the amount of injected air or water increased,the negative pressure of the silica gel negative pressure drainage ball decreased rapidly,dropping to zero when 150 mL of water or air was injected.In contrast,the negative pressure of gastrointestinal decompression apparatus decreased slowly,maintaining an ideal value even when 300 mL of water or air was injected.And statistical analysis demonstrated that patients who had been treated with the gastrointestinal decompression apparatus were less likely to develop severe complications than those who had been treated with the silica gel negative pressure drainage ball(P<0.05).CONCLUSION This study showed that the gastrointestinal decompression apparatus has the advantages of large suction capacity,long duration of continuous negative pressure,and good drainage effect,all of which are the favorable factors for the use of this apparatus for negative pressure drainage in anterior cervical surgery. 展开更多
关键词 SPINE Anterior cervical surgery negative pressure Drainage Gastrointestinal decompression apparatus Silica gel negative pressure drainage ball
下载PDF
Clinical application of flexible ureteroscopic sheath with controllable intraluminal pressure in treating ureteral stones 被引量:3
20
作者 Yuming Zhong Donghua Xie +5 位作者 Chunxiang Luo Xiaohui Liao Tairong Liu Xiaoling Deng Lunfeng Zhu Leming Song 《Asian Journal of Urology》 CSCD 2023年第2期166-171,共6页
Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure t... Objective:The purpose of the study was to assess the clinical efficacy and safety of a combined perfusion suction platform with pressure feedback control function and an ureteroscopic suction sheath that can measure the ureteropelvic pressure in implementing lithotripsies.Methods:Fifty-two patients who underwent lithotripsy under intelligent monitoring of ureteral intraluminal pressure from June 2016 to January 2018 were retrospectively recruited.The inclusion standard was stone diameter>1.5 cm but<2.5 cm.After the 12/14 Fr suction sheath was placed,manometer interface and suction interface of the sheath were connected to the platform via the pressure sensor and suction tube,respectively.The ureteroscope was connected to the platform perfusion pump,and the crushed stones were aspirated out under negative pressure.Results:According to the location of the stone,21(40.4%)cases were classified as upper ureteral stones,19(36.5%)were midureteral stones,and 12(23.1%)were lower ureteral stones.Forty-seven patients underwent successful primary sheath placement and lithotripsy with a mean operative time of 34.5(standard deviation 18.3)min.Retrograde stone migration did not occur.There were eight patients with hematuria postoperatively.Serious complication was 1.9% with one case of ureteral perforation.Stone clearance was 95.7% at Day 1e2 postoperatively,and 100% at Day 30 postoperatively.Conclusion:Ureteroscopic lithotripsy with intelligent pressure control using our device improved the efficiency of the lithotripsy and rate of stone clearance.The safety of the operation can be ensured.It is worth popularization and application in clinical practice. 展开更多
关键词 suction URETEROSCOPY Intelligent pressure control Ureteral calculi
下载PDF
上一页 1 2 61 下一页 到第
使用帮助 返回顶部