期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Improvement of the Harmonic Technique of Probe for Measurements of Electron Temperature and Ion Density
1
作者 白玉静 李建泉 +3 位作者 徐军 陆文琪 王友年 丁万昱 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第1期58-61,共4页
Conventional Langmuir probe techniques usually face the difficulty of being used in processing plasmas where dielectric compounds form,due to rapid failure by surface insulation.A solution to the problem,the so-called... Conventional Langmuir probe techniques usually face the difficulty of being used in processing plasmas where dielectric compounds form,due to rapid failure by surface insulation.A solution to the problem,the so-called harmonic probe technique,had been proposed and shown effectiveness.In this study,the technique was investigated in detail by changing bias signal amplitudes V_0,and evaluated its accuracy by comparing with the conventional Langmuir probe.It was found that the measured electron temperature Teincreased with V_0,but showing a relatively stable region when V_0〉Te/e in which it was close to the true Tevalue.This is contrary to the general consideration that V_0should be smaller than Te/e for accurate measurement of Te.The phenomenon is interpreted by the non-negligible change of the ion current with V_0at low V_0values.On the other hand,the measured nialso increased with V_0due to the sheath expansion,and to improve the accuracy of niit needs to linearly extrapolate the ni-V_0trend to V_0=0.The results were applied to a diagnosis of the plasmas for chemical vapor deposition of diamond-like carbon thin films and the relationship between plasma parameters and films deposition rates was obtained. 展开更多
关键词 plasma diagnosis Langmuir probe harmonics insulative deposition
下载PDF
Evaluation of ECL Labeled DNA Probe for the Diagnosis of Falciparum Malaria
2
《Chinese Medical Journal》 SCIE CAS CSCD 1994年第7期66-66,共1页
A commercially available non—radioactive DNA labelling kit "enhanced chemiluminescence"(ECL) was evaluated for the diagnosis of falciparum malaria. The results showed that ECL labeled probe successfully det... A commercially available non—radioactive DNA labelling kit "enhanced chemiluminescence"(ECL) was evaluated for the diagnosis of falciparum malaria. The results showed that ECL labeled probe successfully detected as little as 25 pg. Purified DNA of 0.001% parasitemia of cultured Plasmodium falciparum and did not react with human 展开更多
关键词 DNA ECL Evaluation of ECL Labeled DNA probe for the diagnosis of Falciparum Malaria
原文传递
Electrochemical detection of human ferritin based on gold nanorod reporter probe and cotton thread immunoassay device 被引量:1
3
作者 Ting-Ting Song Wei Wang +3 位作者 Li-Li Meng Yan Liu Xiao-Bo Jia Xun Mao 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第2期226-230,共5页
In this study,a natural cotton thread immunoassay device combined with gold nanorod(GNR) reporter probe is developed for the rapid,sensitive and quantitative electrochemical determination of human ferritin,a lung ca... In this study,a natural cotton thread immunoassay device combined with gold nanorod(GNR) reporter probe is developed for the rapid,sensitive and quantitative electrochemical determination of human ferritin,a lung cancer related biomarker.Human ferritin as an analyte and a pair of monoclonal antibodies are used to demonstrate the proof-of-concept on the cotton thread immunoassay device.An enhancement of the sensitivity is achieved by using gold nanorod as an electroactive report probe compared with a traditional gold nanoparticle(GNP) report probe.The device was capable of measuring 1.58 ng/mL ferritin in 30 min by anodic stripping voltammetry(ASV) testing,which meet the requirement for clinical diagnosis. 展开更多
关键词 Cotton thread immunoassay device Gold nanorod reporter probe Point-of-care diagnosis Protein detection Electrochemical immunoassay
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部