期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Candidate reference measurement procedure for serum 17-hydroxyprogesterone quantification via isotope dilution liquid chromatography–tandem mass spectrometry
1
作者 Ji Zhang Yang Jiang +8 位作者 Ting Liu Xiongwei Liu Hui Huang Yanxiang Cheng Jieyan Li Bangning Cheng Chungen Qian Xufu Xiang Jun-Fa Xu 《iLABMED》 2024年第2期98-107,共10页
Background:Accurate quantification of 17-hydroxyprogesterone(17-OHP)in serum is vital for clinical and research applications.However,inter-laboratory variability in test results exists owing to the lack of a standardi... Background:Accurate quantification of 17-hydroxyprogesterone(17-OHP)in serum is vital for clinical and research applications.However,inter-laboratory variability in test results exists owing to the lack of a standardized reference measurement procedure(RMP).Therefore,in this study,we developed a highly accurate,cost-effective,and user-friendly candidate RMP(cRMP)for analyzing 17-OHP in serum.Methods:We quantified 17-OHP in serum using a one-step liquid–liquid extraction method with the addition of 17-OHP-^(13)C_(3),followed by liquid chromatography–tandem mass spectrometry.The ability of these methods to suppress interference was evaluated by chromatographic analysis.We assessed accuracy,specificity,the lower limit of quantitation,linearity,and matrix effects by following the standards specified by the Clinical and Laboratory Standards Institute.The consistency between the developed cRMP and the chemiluminescence method was evaluated through experiments with 120 clinical samples.Results:The developed cRMP required only 8 min for accurate quantification of serum 17-OHP without bias from matrix effects or interference from 19 metabolites added as potential interferents.The method exhibited favorable measurement performance,with a quantitation limit of 0.086 ng/mL,linear range of 0.1–400 ng/mL,a total imprecision of≤2.90%,spike recovery of 100.1%–100.6%,and relative deviations from assigned target values(RfB Institution)of−2.91%to 1.10%.The cRMP demonstrated good consistency with the conventional assay(chemiluminescence method),with a correlation coefficient R of 0.96977.Conclusion:A cRMP with high accuracy,cost-effectiveness,and convenient operation was developed for quantifying 17-OHP in serum.Its simplicity and robust performance make it an invaluable addition to the arsenal of analytical tools available for laboratories.This method can enhance the accuracy and reliability of 17-OHP measurements across various laboratories. 展开更多
关键词 17-hydroxyprogesterone isotope dilution liquid chromatography-tandem mass spectrometry reference measurement procedure SERUM
原文传递
Consequences of Insufficient Selectivity in Quantitative and Qualitative Chemical Analysis
2
作者 Mats Larsson Göran Nilsson 《Journal of Analytical Sciences, Methods and Instrumentation》 2023年第2期13-25,共13页
A problem in chemical analysis in connection with measurements of a substance normally occurring in a sample, or identification of a substance which should not exist in a sample, is insufficient selectivity. In this a... A problem in chemical analysis in connection with measurements of a substance normally occurring in a sample, or identification of a substance which should not exist in a sample, is insufficient selectivity. In this article, we analyze this problem and propose remedies. We use a real doping case to illustrate how chemical noise causes a serious selectivity problem, probably causing a false positive outcome. 展开更多
关键词 Chemical Analysis Quantitative and Qualitative Selectivity Chemical measurement procedures measurement Errors Chemical Noise
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部