期刊文献+
共找到30,057篇文章
< 1 2 250 >
每页显示 20 50 100
Signal intensity changes of dentate nucleus on plain MR T1WI innasopharyngeal carcinoma patients after radiotherapy andmultiple injections of gadolinium-base contrast agent
1
作者 SUN Jiping ZHOU Jian +2 位作者 TAO Zhigang LIANG Jiafeng DING Zhongxiang 《中国医学影像技术》 CSCD 北大核心 2024年第8期1170-1173,共4页
Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(... Objective To observe changes of plain MR T1WI signal intensity of dentate nucleus in nasopharyngeal carcinoma patients after radiotherapy and multiple times of intravenous injection of gadolinium-based contrast agent(GBCA).Methods Fifty patients with pathologically confirmed nasopharyngeal carcinoma and received intensity-modulated radiotherapy were retrospectively enrolled as the nasopharyngeal carcinoma group,and 50 patients with other malignant tumors and without history of brain radiotherapy were retrospectively enrolled as the control group.All patients received yearly GBCA enhanced MR examinations for the nasopharynx or the head.T1WI signal intensities of the dentate nucleus and the pons on same plane were measured based on images in the year of confirmed diagnosis(recorded as the first year)and in the second to the fifth years.T1WI signal intensity ratio of year i(ranging from 1 to 5)was calculated with values of dentate nucleus divided by values of the pons(ΔSI i),while the percentage of relative changes of year j(ranging from 2 to 5)was calculated withΔSI j compared toΔSI 1(Rchange j).The values of these two parameters were compared,and the correlation ofΔSI and GBCA injection year-time was evaluated within each group.Results No significant difference of gender,age norΔSI 1 was found between groups(all P>0.05).The second to the fifth yearΔSI and Rchange in nasopharyngeal carcinoma group were all higher than those in control group(all P<0.05).Within both groups,ΔSI was positively correlated with GBCA injection year-time(both P<0.05).Conclusion Patients with nasopharyngeal carcinoma who underwent radiotherapy and multiple times of intravenous injection of GBCA tended to be found with gradually worsening GBCA deposition in dentate nucleus,for which radiotherapy might be a risk factor. 展开更多
关键词 nasopharyngeal neoplasms RADIOTHERAPY contrast media cerebellar nuclei
下载PDF
Recommendation Method for Contrastive Enhancement of Neighborhood Information
2
作者 Hairong Wang Beijing Zhou +1 位作者 Lisi Zhang He Ma 《Computers, Materials & Continua》 SCIE EI 2024年第1期453-472,共20页
Knowledge graph can assist in improving recommendation performance and is widely applied in various person-alized recommendation domains.However,existing knowledge-aware recommendation methods face challenges such as ... Knowledge graph can assist in improving recommendation performance and is widely applied in various person-alized recommendation domains.However,existing knowledge-aware recommendation methods face challenges such as weak user-item interaction supervisory signals and noise in the knowledge graph.To tackle these issues,this paper proposes a neighbor information contrast-enhanced recommendation method by adding subtle noise to construct contrast views and employing contrastive learning to strengthen supervisory signals and reduce knowledge noise.Specifically,first,this paper adopts heterogeneous propagation and knowledge-aware attention networks to obtain multi-order neighbor embedding of users and items,mining the high-order neighbor informa-tion of users and items.Next,in the neighbor information,this paper introduces weak noise following a uniform distribution to construct neighbor contrast views,effectively reducing the time overhead of view construction.This paper then performs contrastive learning between neighbor views to promote the uniformity of view information,adjusting the neighbor structure,and achieving the goal of reducing the knowledge noise in the knowledge graph.Finally,this paper introduces multi-task learning to mitigate the problem of weak supervisory signals.To validate the effectiveness of our method,experiments are conducted on theMovieLens-1M,MovieLens-20M,Book-Crossing,and Last-FM datasets.The results showthat compared to the best baselines,our method shows significant improvements in AUC and F1. 展开更多
关键词 contrastive learning knowledge graph recommendation method
下载PDF
Optical design of a novel near-infrared phase contrast imaging(NI-PCI)diagnostic on the HL-2A tokamak
3
作者 徐皓 龚少博 +11 位作者 余羿 许敏 兰涛 王志斌 石中兵 聂林 赵光义 刘灏 周艺轩 袁子豪 肖晨雨 陈坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期31-37,共7页
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr... The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1). 展开更多
关键词 phase contrast imaging near infrared laser plasma laser diagnostic
下载PDF
Near-Infrared Fluorescence Imaging Contrast Agents for Clinical Research: Limitations and Alternatives
4
作者 Serigne Moussa Badiane Elhadji A. L. Bathily +1 位作者 Fawrou Seye Louis A.D. Diouf 《Open Journal of Biophysics》 2024年第1期73-77,共5页
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical... Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers. 展开更多
关键词 Fluorescence Imaging contrast Agents Clinical Research
下载PDF
Attribution of Biases of Interhemispheric Temperature Contrast in CMIP6 Models
5
作者 Shiyan ZHANG Yongyun HU +1 位作者 Jiankai ZHANG Yan XIA 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第2期325-340,共16页
One of the basic characteristics of Earth's modern climate is that the Northern Hemisphere(NH) is climatologically warmer than the Southern Hemisphere(SH). Here, model performances of this basic state are examined... One of the basic characteristics of Earth's modern climate is that the Northern Hemisphere(NH) is climatologically warmer than the Southern Hemisphere(SH). Here, model performances of this basic state are examined using simulation results from 26 CMIP6 models. Results show that the CMIP6 models underestimate the contrast in interhemispheric surface temperatures on average(0.8 K for CMIP6 mean versus 1.4 K for reanalysis data mean), and that there is a large intermodel spread, ranging from -0.7 K to 2.3 K. A box model energy budget analysis shows that the contrast in interhemispheric shortwave absorption at the top of the atmosphere, the contrast in interhemispheric greenhouse trapping, and the crossequatorial northward ocean heat transport, are all underestimated in the multimodel mean. By examining the intermodel spread, we find intermodel biases can be tracked back to biases in midlatitude shortwave cloud forcing in AGCMs. Models with a weaker interhemispheric temperature contrast underestimate the shortwave cloud reflection in the SH but overestimate the shortwave cloud reflection in the NH, which are respectively due to underestimation of the cloud fraction over the SH extratropical ocean and overestimation of the cloud liquid water content over the NH extratropical continents.Models that underestimate the interhemispheric temperature contrast exhibit larger double ITCZ biases, characterized by excessive precipitation in the SH tropics. Although this intermodel spread does not account for the multimodel ensemble mean biases, it highlights that improving cloud simulation in AGCMs is essential for simulating the climate realistically in coupled models. 展开更多
关键词 interhemispheric temperature contrast energy balance shortwave cloud forcing ITCZ CMIP6 AGCM
下载PDF
Contrastive Consistency and Attentive Complementarity for Deep Multi-View Subspace Clustering
6
作者 Jiao Wang Bin Wu Hongying Zhang 《Computers, Materials & Continua》 SCIE EI 2024年第4期143-160,共18页
Deep multi-view subspace clustering (DMVSC) based on self-expression has attracted increasing attention dueto its outstanding performance and nonlinear application. However, most existing methods neglect that viewpriv... Deep multi-view subspace clustering (DMVSC) based on self-expression has attracted increasing attention dueto its outstanding performance and nonlinear application. However, most existing methods neglect that viewprivatemeaningless information or noise may interfere with the learning of self-expression, which may lead to thedegeneration of clustering performance. In this paper, we propose a novel framework of Contrastive Consistencyand Attentive Complementarity (CCAC) for DMVsSC. CCAC aligns all the self-expressions of multiple viewsand fuses them based on their discrimination, so that it can effectively explore consistent and complementaryinformation for achieving precise clustering. Specifically, the view-specific self-expression is learned by a selfexpressionlayer embedded into the auto-encoder network for each view. To guarantee consistency across views andreduce the effect of view-private information or noise, we align all the view-specific self-expressions by contrastivelearning. The aligned self-expressions are assigned adaptive weights by channel attention mechanism according totheir discrimination. Then they are fused by convolution kernel to obtain consensus self-expression withmaximumcomplementarity ofmultiple views. Extensive experimental results on four benchmark datasets and one large-scaledataset of the CCAC method outperformother state-of-the-artmethods, demonstrating its clustering effectiveness. 展开更多
关键词 Deep multi-view subspace clustering contrastive learning adaptive fusion self-expression learning
下载PDF
Laser speckle contrast imaging to predict the effect of temporary spinal cord stimulation in postherpetic neuralgia patients: A prospective observational study
7
作者 Xiang Huang Dacheng Tang +3 位作者 Pan Chen Lumiao Chen Xiaohong Li Xiaoping Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期69-75,共7页
Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser s... Temporary spinal cord stimulation(tSCS)can effectively reduce the pain and severity of postherpetic neuralgia(PHN).However,there are no effective and objective methods for predicting the effects of tSCS on PHN.Laser speckle contrast imaging(LSCI)is frequently used in neurology to evaluate the effectiveness of treatment.To assess the accuracy of LSCI in predicting the impact of tSCS on PHN,14 adult patients receiving tSCS treatments for spinal nerve-innervated(C6-T2)PHN participated in this observational study.Visual analog scale(VAS)assessments and LSCI bloodflow images of the-ngers were recorded after the tSCS procedure.The results showed that the VAS scores of all patients decreased signi-cantly.Moreover,the bloodflow index(BFI)values were signi-cantly higher than they were before the procedure.Increased bloodflow and pain alleviation were positively correlated.The-ndings indicated that spinal nerve PHN(C6-T2)was signi-cantly reduced by tSCS.Pain alleviation by tSCS was positively correlated with increased bloodflow in the hand.The effect of tSCS on PHN may thus be predicted using an independent and consistent indicator such as LSCI. 展开更多
关键词 Laser speckle contrast imaging temporary spinal cord stimulation postherpetic neuralgia
下载PDF
Gastrointestinal contrast-enhanced ultrasonography for diagnosis and treatment of peptic ulcer in children
8
作者 Yu-Hua Zhang Zhi-Hua Xu +1 位作者 Shuang-Shuang Ni Hong-Xia Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期705-713,共9页
BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastr... BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastrointestinal contrast-enhanced ultrasonography(CEUS)has the advantages of being painless,noninvasive,nonradioactive,easy to use,and safe.AIM To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children.METHODS We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022.All children were examined by routine ultrasound,gastrointestinal CEUS,and gastroscopy.The pathological results of gastroscopy were taken as the gold standard.Routine ultrasonography was performed before gastrointestinal CEUS.Conventional ultrasound showed the thickness of the gastroduodenal wall,gastric peristalsis,and the adjacent organs and tissues around the abdominal cavity.Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall;the size,location and shape of the ulcer;gastric peristalsis;and adjacent organs and tissues around the abdominal cavity.The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS.All children received informed consent from their guardians for CEUS.This study was reviewed and approved by the hospital medical ethics committee.RESULTS Among the 43 children,17(15 male,2 female)were diagnosed with peptic ulcer by gastroscopy.There were 26 children with nonpeptic ulcer.There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound.The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1%(34/43),which was significantly different from that of gastroscopy(P=0.033).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low.Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS.The diagnostic coincidence rate of peptic ulcer in children was 95.3%(41/43).There was no significant difference between CEUS and gastroscopy(P=0.655).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high.CONCLUSION Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children,and can be used as a preliminary examination method. 展开更多
关键词 contrast-enhanced ultrasound Peptic ulcer CHILDREN Gastrointestinal tract Abdominal pain Acoustic contrast agent
下载PDF
A Second-Order Image Denoising Model for Contrast Preservation
9
作者 Wei Zhi 《Communications on Applied Mathematics and Computation》 EI 2024年第2期1406-1427,共22页
In this work,we propose a second-order model for image denoising by employing a novel potential function recently developed in Zhu(J Sci Comput 88:46,2021)for the design of a regularization term.Due to this new second... In this work,we propose a second-order model for image denoising by employing a novel potential function recently developed in Zhu(J Sci Comput 88:46,2021)for the design of a regularization term.Due to this new second-order derivative based regularizer,the model is able to alleviate the staircase effect and preserve image contrast.The augmented Lagrangian method(ALM)is utilized to minimize the associated functional and convergence analysis is established for the proposed algorithm.Numerical experiments are presented to demonstrate the features of the proposed model. 展开更多
关键词 Image denoising Variational model Image contrast Augmented Lagrangian method(ALM)
下载PDF
Improved Weighted Local Contrast Method for Infrared Small Target Detection
10
作者 Pengge Ma Jiangnan Wang +3 位作者 Dongdong Pang Tao Shan Junling Sun Qiuchun Jin 《Journal of Beijing Institute of Technology》 EI CAS 2024年第1期19-27,共9页
In order to address the problem of high false alarm rate and low probabilities of infrared small target detection in complex low-altitude background,an infrared small target detection method based on improved weighted... In order to address the problem of high false alarm rate and low probabilities of infrared small target detection in complex low-altitude background,an infrared small target detection method based on improved weighted local contrast is proposed in this paper.First,the ratio information between the target and local background is utilized as an enhancement factor.The local contrast is calculated by incorporating the heterogeneity between the target and local background.Then,a local product weighted method is designed based on the spatial dissimilarity between target and background to further enhance target while suppressing background.Finally,the location of target is obtained by adaptive threshold segmentation.As experimental results demonstrate,the method shows superior performance in several evaluation metrics compared with six existing algorithms on different datasets containing targets such as unmanned aerial vehicles(UAV). 展开更多
关键词 infrared small target unmanned aerial vehicles(UAV) local contrast target detection
下载PDF
Navigating nephrotoxic waters:A comprehensive overview of contrast-induced acute kidney injury prevention
11
作者 Panagiotis Theofilis Rigas Kalaitzidis 《World Journal of Radiology》 2024年第6期168-183,共16页
Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to lo... Contrast-induced acute kidney injury(CI-AKI)is the third leading cause of acute kidney injury deriving from the intravascular administration of contrast media in diagnostic and therapeutic procedures and leading to longer in-hospital stay and increased short and long-term mortality.Its pathophysiology,although not well-established,revolves around medullary hypoxia paired with the direct toxicity of the substance to the kidney.Critically ill patients,as well as those with pre-existing renal disease and cardiovascular comorbidities,are more susceptible to CI-AKI.Despite the continuous research in the field of CI-AKI prevention,clinical practice is based mostly on periprocedural hydration.In this review,all the investigated methods of prevention are presented,with an emphasis on the latest evidence regarding the potential of RenalGuard and contrast removal systems for CI-AKI prevention in high-risk individuals. 展开更多
关键词 contrast-induced acute kidney injury contrast media PREVENTION HYDRATION RenalGuard Dyevert
下载PDF
Dynamic contrast enhanced ultrasound in differential diagnosis of hepatocellular carcinoma: A systematic review and meta-analysis
12
作者 Giorgio Esposto Paolo Santini +5 位作者 Fabrizio Termite Linda Galasso Irene Mignini Maria Elena Ainora Antonio Gasbarrini Maria Assunta Zocco 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第6期2804-2815,共12页
BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histologic... BACKGROUND Non-invasive differential diagnosis between hepatocellular carcinoma(HCC)and other liver cancer(i.e.cholangiocarcinoma or metastasis)is highly challenging and definitive diagnosis still relies on histological exam.The patterns of enhancement and wash-out of liver nodules can be used to stratify the risk of malignancy only in cirrhotic patients and HCC frequently shows atypical features.Dynamic contrast-enhanced ultrasound(DCEUS)with standardized software could help to overcome these obstacles,providing functional and quantitative parameters and potentially improving accuracy in the evaluation of tumor perfusion.AIM To explore clinical evidence regarding the application of DCEUS in the differential diagnosis of liver nodules.METHODS A comprehensive literature search of clinical studies was performed to identify the parameters of DCEUS that could relate to histological diagnosis.In accordance with the study protocol,a qualitative and quantitative analysis of the evidence was planned.RESULTS Rise time was significantly higher in HCC patients with a standardized mean difference(SMD)of 0.83(95%CI:0.48-1.18).Similarly,other statistically significant parameters were mean transit time local with a SMD of 0.73(95%CI:0.20-1.27),peak enhancement with a SMD of 0.37(95%CI:0.03-0.70),area wash-in area under the curve with a SMD of 0.47(95%CI:0.13-0.81),wash-out area under the curve with a SMD of 0.55(95%CI:0.21-0.89)and wash-in and wash-out area under the curve with SMD of 0.51(95%CI:0.17-0.85).SMD resulted not significant in fall time and wash-in rate,but the latter presented a trend towards greater values in HCC compared to intrahepatic cholangiocarcinoma.CONCLUSION DCEUS could improve non-invasive diagnosis of HCC,leading to less liver biopsy and early treatment.This quantitative analysis needs to be applied on larger cohorts to confirm these preliminary results. 展开更多
关键词 Dynamic contrast enhanced ultrasound Hepatocellular carcinoma Intracellular cholangiocarcinoma Quantitative ultrasound Liver cancer Time-intensity curve
下载PDF
Is it a normal phenomenon for pediatric patients to have brain leptomeningeal contrast enhancement on 3-tesla magnetic resonance imaging?
13
作者 Min Ai Hang-Hang Zhang +1 位作者 Yi Guo Jun-Bang Feng 《World Journal of Radiology》 2024年第5期136-138,共3页
Determining whether sevoflurane sedation in children leads to“pseudo”prominent leptomeningeal contrast enhancement(pLMCE)on 3 Tesla magnetic resonance imaging will help reduce overdiagnosis by radiologists and clari... Determining whether sevoflurane sedation in children leads to“pseudo”prominent leptomeningeal contrast enhancement(pLMCE)on 3 Tesla magnetic resonance imaging will help reduce overdiagnosis by radiologists and clarify the pathophysiological changes of pLMCE. 展开更多
关键词 Pediatrics patients SEVOFLURANE BRAIN Prominent leptomeningeal contrast enhancement Magnetic resonance imaging
下载PDF
The Inheritance and Application of Chinese Reverse Contrast Typeface Style
14
作者 Suimeng Qin Albert Young Choi 《Psychology Research》 2024年第2期70-80,共11页
This paper discusses the inheritance and application of Chinese character reverse contrast typeface style.It begins by analyzing the visual features of Western reverse contrast typeface styles,with a focus on Caslon I... This paper discusses the inheritance and application of Chinese character reverse contrast typeface style.It begins by analyzing the visual features of Western reverse contrast typeface styles,with a focus on Caslon Italian and French Clarendon,providing a Western perspective reference for subsequent Chinese character reverse contrast typeface style designs.The paper then traces the origins of the Chinese reverse contrast style,from the calligraphy style"Lacquer Script"to the earliest printing type"フワンテール形",exploring the historical background and cultural significance of the Chinese reverse contrast style.In the methodology section of Chinese character reverse contrast typeface style design,the discussion is conducted from two dimensions:inheritance and application.In terms of inheritance,through an in-depth analysis of"Lacquer Script"and"フワンテール形"typeface style,the paper summarizes three basic theories for modern Chinese character reverse contrast typeface style design.In the application section,it examines in detail the two most influential recent typeface styles,"Ribaasu"and"Basic Artistic",outlining three directions of application:extreme horizontal stroke variations,exaggerated contrast,and diverse decorative strokes,showcasing new directions and possibilities for Chinese character reverse contrast typeface style design.This paper not only reviews the developmental history of the Chinese character reverse contrast typeface style but also analyzes the design methodology of Chinese character reverse contrast typeface style through specific case studies. 展开更多
关键词 reverse contrast fonts Chinese character font design design method
下载PDF
A Contrastive Analysis of English and Chinese Idioms About Color Words & Their Cultural Connotations
15
作者 WANG Hong-mei 《Sino-US English Teaching》 2024年第9期439-442,共4页
There are many idioms related to color words in English and Chinese.The use of color words in idioms adds beauty and vividness to the language.Due to the cultural differences,“color idioms”have gained different cult... There are many idioms related to color words in English and Chinese.The use of color words in idioms adds beauty and vividness to the language.Due to the cultural differences,“color idioms”have gained different cultural connotations with the development of English and Chinese languages.It is of great significance to accurately understand and grasp the meanings and differences of color-related idioms in Chinese and English.This paper intends to analyze and expound the cultural connotations of English and Chinese idioms related to several widely used basic color words with the aim of helping English learners know and use the idioms about color words better. 展开更多
关键词 idioms about color words cultural connotation contrastive analysis
下载PDF
Relationship of inflammatory indices with left atrial appendage thrombus or spontaneous echo contrast in patients with atrial fibrillation
16
作者 Zhao Wang Bin-Hao Wang +3 位作者 Xiao-Lei Yang Yun-Long Xia Sheng-Min Zhang Ying Che 《World Journal of Clinical Cases》 SCIE 2024年第21期4550-4557,共8页
BACKGROUND Inflammatory indices derived from complete blood tests have been reported to be associated with poor outcomes in patients with atrial fibrillation(AF).The data about the relationship between inflammatory in... BACKGROUND Inflammatory indices derived from complete blood tests have been reported to be associated with poor outcomes in patients with atrial fibrillation(AF).The data about the relationship between inflammatory indices and left atrial appendage thrombus(LAAT)or dense spontaneous echo contrast(SEC)are limited.AIM To explore the value of inflammatory indices for predicting the presence of LAAT or dense SEC in nonvalvular AF patients.METHODS A total of 406 patients with nonvalvular AF who underwent transesophageal echocardiography were included and divided into two groups based on the presence(study group)or absence(control group)of LAAT or dense SEC.Inflammatory indices,including the neutrophil-to-lymphocyte ratio(NLR),platelet–tolymphocyte ratio(PLR),and lymphocyte-to-monocyte ratio(LMR),were calculated from complete blood analysis.The associations of inflammatory indices RESULTS LAAT and dense SEC were detected in 11(2.7%)and 42(10.3%)patients,respectively.The PLR only showed an association with LAAT/dense SEC in the univariate model.Elevated NLR(odds ratio[OR]=1.48,95%confidence interval[CI]:1.11-1.98,P=0.007)and reduced LMR(OR=0.59,95%CI:0.41-0.83,P=0.003)were found to be independent risk factors for the presence of LAAT/dense SEC.The areas under the NLR and LMR curves for predicting LAAT/dense SEC were 0.73(95%CI:0.66-0.80,P<0.001)and 0.73(95%CI:0.65-0.81,P<0.001),respectively,while the cutoff values were 2.8(sensitivity:69.8%;specificity:64.0%)and 2.4(sensitivity:71.7%;specificity:60.6%),respectively.CONCLUSION Increased NLR and decreased LMR may predict LAAT/dense SEC in patients with nonvalvular AF. 展开更多
关键词 Nonvalvular atrial fibrillation Left atrial appendage thrombus Spontaneous echo contrast Neutrophil–lymphocyte ratio Lymphocyte–monocyte ratio
下载PDF
Binary Phase Shaping and SHG Contrast Ratios
17
作者 Tingyao Xiong 《Journal of Applied Mathematics and Physics》 2024年第8期3026-3035,共10页
Finding binary sequences with Large SHG ratios is very important in the field of ultrafast science, biomedical optics, high-resolution microscopy and label-free imaging. In this paper, we have demonstrated the relatio... Finding binary sequences with Large SHG ratios is very important in the field of ultrafast science, biomedical optics, high-resolution microscopy and label-free imaging. In this paper, we have demonstrated the relation between the SHG contrast ratio and the traditional Merit Factor values. And in the light from known results in Merit Factor Problems, we have shown that Legendre Sequences or Jacobi Sequences, are still the best candidates to obtain binary sequences with large SHG contrast ratios. The authors also discussed the SHG behaviors on some sequences obtained from cyclotomic classes over the finite field GF (2l) . 展开更多
关键词 Binary Phase Shaping Binary Sequences SHG contrast Ratio Merit Factor
下载PDF
Accuracy and Utility of Vessel Analysis Using Non-Contrast CT for Planning Endovascular Aortic Repair
18
作者 Midori Komita-Moriya Yukihisa Ogawa +6 位作者 Akiyuki Kotoku Shintaro Nawata Kenji Kuramochi Yasuyoshi Ogawa Kiyoshi Chiba Hiroshi Nishimaki Hidefumi Mimura 《Open Journal of Medical Imaging》 2024年第3期96-105,共10页
Objectives: This study aimed to determine whether errors in vascular measurements would affect device selection in endovascular aortic repair (EVAR) by comparing measurements obtained using non-contrast computed tomog... Objectives: This study aimed to determine whether errors in vascular measurements would affect device selection in endovascular aortic repair (EVAR) by comparing measurements obtained using non-contrast computed tomography (NCT) with those obtained using contrast-enhanced CT (CECT). Materials and Methods: This single-center, retrospective study included 25 patients who underwent EVAR for abdominal aortic aneurysm at our institution. A 1-mm horizontal cross-sectional slice of NCT and CECT from each patient was retrospectively reviewed. The area from the abdominal aorta to the common iliac artery was divided into four zones. A centerline was created using the NCT by manually plotting the center points. Subsequently, the centerlines were automatically extracted and manually corrected during the arterial phase of CECT. The diameter and length of each zone were measured for each modality. The mean diameters and lengths of the target vessels were compared between NCT and CECT. Results: The measurements obtained using both methods were reproducible and demonstrated good agreement. The mean differences in vessel length and diameter measurements for each segment between NCT and CECT were not statistically significant, indicating good consistency. Conclusion: NCT may be useful for preoperative EVAR evaluation in patients with renal dysfunction or allergies to contrast agents. 展开更多
关键词 Non-contrast CT Vessel Analysis EVAR contrast-Enhanced CT Abdominal Aortic Aneurysm
下载PDF
Unilateral contrast-induced encephalopathy with contrast medium exudation:A case report 被引量:1
19
作者 Zhi-Yuan Zhang Hang Lv +4 位作者 Pei-Jian Wang Dan-Yang Zhao Li-Yong Zhang Ji-Yue Wang Ji-Heng Hao 《World Journal of Clinical Cases》 SCIE 2023年第10期2260-2266,共7页
BACKGROUND Contrast-induced encephalopathy(CIE)is a rare transient,reversible abnormality in the structure or function of the nervous system caused by the intravascular use of contrast agents.CIE can present with a ra... BACKGROUND Contrast-induced encephalopathy(CIE)is a rare transient,reversible abnormality in the structure or function of the nervous system caused by the intravascular use of contrast agents.CIE can present with a range of neurological manifestations,including focal neurological deficits(hemiplegia,hemianopia,cortical blindness,aphasia,and parkinsonism)and systemic symptoms(confusion,seizures,and coma).However,if not accurately diagnosed and treated in a timely manner,CIE can cause irreversible damage to patients,especially critically ill patients.CASE SUMMARY A male in his 50 s,2 h after digital subtraction angiography,had a progressive disorder of consciousness,mixed aphasia,bilateral pupillary sluggish light reflex,and right limb weakness.Seven hours after the procedure,he developed unconsciousness,high fever(39.5°C),seizures,hemiplegia,neck stiffness(+),and right Babinski signs(+).computed tomography(CT)findings 2 h postprocedure were very confusing and led us to misdiagnose the patient with subarachnoid hemorrhage.Brain CT was performed again 7 h after the procedure.Compared with the CT 2 h after the procedure,the CT 7 h after the procedure showed that the manifestations of subarachnoid hemorrhage in the left cerebral hemisphere had disappeared and were replaced by brain tissue swelling,and the cerebral sulci had disappeared.Combined with the clinical manifestations of the patient and after the exclusion of subarachnoid hemorrhage and cerebrovascular embolism,we diagnosed the patient with CIE,and intravenous fluids were given for adequate hydration,as well as mannitol,albumin dehydration,furosemide and the glucocorticoid methylprednisolone.After 17 d of active treatment,the patient was discharged with no sequelae.CONCLUSION CIE should be taken seriously,but it is easily misdiagnosed,and once CIE is diagnosed,rapid,accurate diagnosis and treatment are critical steps.Whether a follow-up examination using a contrast agent can be performed should be closely evaluated,and the patient should be fully informed of the associated risks. 展开更多
关键词 contrast agents Diagnosis ENCEPHALOPATHY MECHANISMS Treatment
下载PDF
Log Anomaly Detection Based on Hierarchical Graph Neural Network and Label Contrastive Coding 被引量:1
20
作者 Yong Fang Zhiying Zhao +1 位作者 Yijia Xu Zhonglin Liu 《Computers, Materials & Continua》 SCIE EI 2023年第2期4099-4118,共20页
System logs are essential for detecting anomalies,querying faults,and tracing attacks.Because of the time-consuming and labor-intensive nature of manual system troubleshooting and anomaly detection,it cannot meet the ... System logs are essential for detecting anomalies,querying faults,and tracing attacks.Because of the time-consuming and labor-intensive nature of manual system troubleshooting and anomaly detection,it cannot meet the actual needs.The implementation of automated log anomaly detection is a topic that demands urgent research.However,the prior work on processing log data is mainly one-dimensional and cannot profoundly learn the complex associations in log data.Meanwhile,there is a lack of attention to the utilization of log labels and usually relies on a large number of labels for detection.This paper proposes a novel and practical detection model named LCC-HGLog,the core of which is the conversion of log anomaly detection into a graph classification problem.Semantic temporal graphs(STG)are constructed by extracting the raw logs’execution sequences and template semantics.Then a unique graph classifier is used to better comprehend each STG’s semantic,sequential,and structural features.The classification model is trained jointly by graph classification loss and label contrastive loss.While achieving discriminability at the class-level,it increases the fine-grained identification at the instance-level,thus achieving detection performance even with a small amount of labeled data.We have conducted numerous experiments on real log datasets,showing that the proposed model outperforms the baseline methods and obtains the best all-around performance.Moreover,the detection performance degrades to less than 1%when only 10%of the labeled data is used.With 200 labeled samples,we can achieve the same or better detection results than the baseline methods. 展开更多
关键词 Log analysis anomaly detection contrastive learning graph neural network
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部