A method based on the cross-sectional relationship between^(10)B(n,α)^(7)Li and^(1)H(n,γ)^(2)H was proposed to detect and reconstruct the three-dimensional boron concentration/dose distribution in vivo during boron ...A method based on the cross-sectional relationship between^(10)B(n,α)^(7)Li and^(1)H(n,γ)^(2)H was proposed to detect and reconstruct the three-dimensional boron concentration/dose distribution in vivo during boron neutron capture therapy(BNCT).Factors such as the neutron energy,fluence rate,and degree of non-uniform distribution of the boron concentration in a voxel may affect the results of this method.A theoretical analysis of the accuracy of the method using a Monte Carlo simulation shows that the determining error is generally less than 1%under different tumor locations and neutron source configurations.When the voxel size is larger than 0.4 cm,the determining error might be higher for a non-uniformly distributed boron concentration in the voxel because of the changes in the neutron energy and fluence rate.In conclusion,the proposed method enables an accurate threedimensional boron determination in vivo during BNCT.展开更多
Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as ...Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.展开更多
A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlo...A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlorine in the neutron field, the linear relationship between the iron analytical coefficient and total iron content was poor, increasing the error in the quantitative analysis. To solve this problem, gamma-ray self-absorption compensation and a neutron field correction algorithm were proposed, and the experimental results have been corrected using this algorithm. The results show that the linear relationship between the iron analytical coefficient and total iron content was considerably improved after the correction. The linear correlation coefficients reached 0.99 or more.展开更多
This paper described new development of the neutron induced prompt gamma-ray analysis(NIPGA) technology in 1988-2003.The pulse fast-thermal neutron activation analysis method,which utilized the inelastic reaction and ...This paper described new development of the neutron induced prompt gamma-ray analysis(NIPGA) technology in 1988-2003.The pulse fast-thermal neutron activation analysis method,which utilized the inelastic reaction and capture reaction jointly,was employed to measure the elemental contents more efficiently.Lifetime of the neutron generator was more than 10000h and the performance of detector and MCA reached a high level.At the same time,Monte Carlo library least-square method was used to solve the nonlinearity problem in the NIPGA.展开更多
Increased accuracy of proton beam delivery provides additional benefits to the patients undergo the treatment.A prompt gamma imaging detector can provide additional information during the treatment,as the prompt gamma...Increased accuracy of proton beam delivery provides additional benefits to the patients undergo the treatment.A prompt gamma imaging detector can provide additional information during the treatment,as the prompt gammas produced by the interactions between protons and human tissues are related to the range and profile of the beam in the patient.This paper makes a Monte Carlo feasibility study for a pixelated prompt gamma imaging detector which can not only measure the proton range but also merge the beam profile and 3D beam image inside the patient.FLUKA simulation result shows that this detector can reduce background noise and measure the range and beam profile by using of grated shielding material,vertical gammas selection and a 5MeV energy window.展开更多
This paper introduces the principles, instrumentation, implementation, and industrial applications of an on- line thermal neutron prompt- gamma element analysis system (using a 252Cf neutron source, Am- Be neutron sou...This paper introduces the principles, instrumentation, implementation, and industrial applications of an on- line thermal neutron prompt- gamma element analysis system (using a 252Cf neutron source, Am- Be neutron source, or neutron generator). The energy resolution of the system at the H prompt- gamma full- energy photopeak (2.22325 MeV) is 3.6 keV. The concentration measurement error of A12O3, Fe2O3, CaO and SiO2 is ±0.3%,±0.1%.±0.4% and ±0.4%, respectively.The system has been tested on- site at both the Shandong and the Zhengzhou Aluminum Works. Our preliminary on- site measurements confirm that the stability, reliability, measurement range, and accuracy of the system can meet the requirements of the aluminum production process. Facilitation of this measurement at aluminum plants is expected to reduce plant costs by over 3 million dollars annually through reduced energy consumption, more rapid qualification of pulps being mixed during the production process, and in reduced labor costs.展开更多
In this paper,computational methods are used to optimize the design of a prompt-gamma neutron activation analysis(PGNAA) system on China Advanced Research Reactor(CARR).Approaches are adopted for obtaining accurate ne...In this paper,computational methods are used to optimize the design of a prompt-gamma neutron activation analysis(PGNAA) system on China Advanced Research Reactor(CARR).Approaches are adopted for obtaining accurate neutron beam parameter and saving the computing time.For the radiation shielding design,the optimizing factors include the cost,weight,volume,machining convenience and background radiation at the detector position.Low background spectrum and high sensitivity are expected.The simulation results,and experiences from international PGNAA community,were used in the design of the CARR PGNAA system.展开更多
An experiment investigating gamma emission in hadron therapy was performed at Cyclotron Centre Bronowice (CCB), Cracow, Poland, using two different phantom materials—carbon and poly(methyl methacrylate) PMMA. The mea...An experiment investigating gamma emission in hadron therapy was performed at Cyclotron Centre Bronowice (CCB), Cracow, Poland, using two different phantom materials—carbon and poly(methyl methacrylate) PMMA. The measurements were carried out at 70 MeV proton beam energy and the gamma quanta were registered with the use of HP Ge detector with scintillation anti-Compton shielding. Although the primary aim was to establish a solid experimental data base for future applications in prompt gamma imaging, the data have also been analyzed with regards to the position and shape of the spectral line stemming from deexcitation of the carbon excited state 4.44 MeV. Measurements potentially useful to determine the cross section were performed only at 90° laboratory polar angle. However, benefiting from the very good energy resolution it turned out possible to extract information on angular distribution of the C* (4.44 MeV) deexcitation by analyzing the associated line shape. This paper presents the scheme of model calculations assuming the whole process can be divided into two stages: excitation of carbon nuclei by impinging protons and deexcitation of the C* (4.44 MeV) state.展开更多
The thermal neutron capture gamma ray facility at Pakistan Research Reactor (PARR-1) is being used forthe re-estimation of various properties like capture cross-sections, resonance integral, absolute gamma intensities...The thermal neutron capture gamma ray facility at Pakistan Research Reactor (PARR-1) is being used forthe re-estimation of various properties like capture cross-sections, resonance integral, absolute gamma intensities, etc.of different isotopes. The data for gamma ray transitions from the capture of thermal neutrons by 55Mn are not ingood agreement specifically below 2 MeV. So there is a need to re-estimate its intensities with better accuracy. Analyticalgrade MnCl2 powder and high purity Mn metal pieces were used in this study. Standard 152Eu and 60Co radioactivesources as well as thermal neutron capture γ-rays in chlorine were chosen for efficiency calibration. The k0standardization technique was applied for these measurements to eliminate systematic errors in efficiencies. Chlorinealso acted as a comparator in k0- factor calculations. The results have been tabulated for the main gamma rays from56Mn in the low as well as in the medium energy regions. The absolute intensities are in good agreement with most ofthe reported values.展开更多
Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstru...Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.展开更多
基金This work was supported by the National Natural Science Foundation of China(Nos.11805100 and 11905106)the Fundamental Research Funds for the Central Universities(No.NG2020003).
文摘A method based on the cross-sectional relationship between^(10)B(n,α)^(7)Li and^(1)H(n,γ)^(2)H was proposed to detect and reconstruct the three-dimensional boron concentration/dose distribution in vivo during boron neutron capture therapy(BNCT).Factors such as the neutron energy,fluence rate,and degree of non-uniform distribution of the boron concentration in a voxel may affect the results of this method.A theoretical analysis of the accuracy of the method using a Monte Carlo simulation shows that the determining error is generally less than 1%under different tumor locations and neutron source configurations.When the voxel size is larger than 0.4 cm,the determining error might be higher for a non-uniformly distributed boron concentration in the voxel because of the changes in the neutron energy and fluence rate.In conclusion,the proposed method enables an accurate threedimensional boron determination in vivo during BNCT.
文摘Prompt gamma neutron activation analysis (PGNAA) is a non-destructive online measurement nuclear analysis method. With its unique advantages, it has been widely used in online analysis of industrial materials such as coal, cement, and minerals in recent years. </span><span style="font-family:Verdana;">However, there are many kinds of literature on PGNAA in the field of industrial materials detection, and there are still a few concluding articles. To this end,</span><span style="font-family:Verdana;"> based on the principle of PGNAA online analysis, the status quo and development of the real-time online detection of industrial material components in the field are reviewed and discussed by consulting a large number of domestic and foreign PGNAA related literature and data, to facilitate the reference of relevant scientific researchers.
基金supported by the National Key Scientific Instrument and Equipment Development Projects(No.2012YQ240121)Liaoning science and technology project(No.2017220010)Changchun Science and Technology Bureau Local Company and College(University,Institution)Cooperation Projects(No.17DY023)
文摘A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlorine in the neutron field, the linear relationship between the iron analytical coefficient and total iron content was poor, increasing the error in the quantitative analysis. To solve this problem, gamma-ray self-absorption compensation and a neutron field correction algorithm were proposed, and the experimental results have been corrected using this algorithm. The results show that the linear relationship between the iron analytical coefficient and total iron content was considerably improved after the correction. The linear correlation coefficients reached 0.99 or more.
基金Supported by Science Foundation for Young Teachers Normal University
文摘This paper described new development of the neutron induced prompt gamma-ray analysis(NIPGA) technology in 1988-2003.The pulse fast-thermal neutron activation analysis method,which utilized the inelastic reaction and capture reaction jointly,was employed to measure the elemental contents more efficiently.Lifetime of the neutron generator was more than 10000h and the performance of detector and MCA reached a high level.At the same time,Monte Carlo library least-square method was used to solve the nonlinearity problem in the NIPGA.
文摘Increased accuracy of proton beam delivery provides additional benefits to the patients undergo the treatment.A prompt gamma imaging detector can provide additional information during the treatment,as the prompt gammas produced by the interactions between protons and human tissues are related to the range and profile of the beam in the patient.This paper makes a Monte Carlo feasibility study for a pixelated prompt gamma imaging detector which can not only measure the proton range but also merge the beam profile and 3D beam image inside the patient.FLUKA simulation result shows that this detector can reduce background noise and measure the range and beam profile by using of grated shielding material,vertical gammas selection and a 5MeV energy window.
文摘This paper introduces the principles, instrumentation, implementation, and industrial applications of an on- line thermal neutron prompt- gamma element analysis system (using a 252Cf neutron source, Am- Be neutron source, or neutron generator). The energy resolution of the system at the H prompt- gamma full- energy photopeak (2.22325 MeV) is 3.6 keV. The concentration measurement error of A12O3, Fe2O3, CaO and SiO2 is ±0.3%,±0.1%.±0.4% and ±0.4%, respectively.The system has been tested on- site at both the Shandong and the Zhengzhou Aluminum Works. Our preliminary on- site measurements confirm that the stability, reliability, measurement range, and accuracy of the system can meet the requirements of the aluminum production process. Facilitation of this measurement at aluminum plants is expected to reduce plant costs by over 3 million dollars annually through reduced energy consumption, more rapid qualification of pulps being mixed during the production process, and in reduced labor costs.
基金Supported by National Natural Science Foundation of China(No.10805077)
文摘In this paper,computational methods are used to optimize the design of a prompt-gamma neutron activation analysis(PGNAA) system on China Advanced Research Reactor(CARR).Approaches are adopted for obtaining accurate neutron beam parameter and saving the computing time.For the radiation shielding design,the optimizing factors include the cost,weight,volume,machining convenience and background radiation at the detector position.Low background spectrum and high sensitivity are expected.The simulation results,and experiences from international PGNAA community,were used in the design of the CARR PGNAA system.
文摘An experiment investigating gamma emission in hadron therapy was performed at Cyclotron Centre Bronowice (CCB), Cracow, Poland, using two different phantom materials—carbon and poly(methyl methacrylate) PMMA. The measurements were carried out at 70 MeV proton beam energy and the gamma quanta were registered with the use of HP Ge detector with scintillation anti-Compton shielding. Although the primary aim was to establish a solid experimental data base for future applications in prompt gamma imaging, the data have also been analyzed with regards to the position and shape of the spectral line stemming from deexcitation of the carbon excited state 4.44 MeV. Measurements potentially useful to determine the cross section were performed only at 90° laboratory polar angle. However, benefiting from the very good energy resolution it turned out possible to extract information on angular distribution of the C* (4.44 MeV) deexcitation by analyzing the associated line shape. This paper presents the scheme of model calculations assuming the whole process can be divided into two stages: excitation of carbon nuclei by impinging protons and deexcitation of the C* (4.44 MeV) state.
文摘The thermal neutron capture gamma ray facility at Pakistan Research Reactor (PARR-1) is being used forthe re-estimation of various properties like capture cross-sections, resonance integral, absolute gamma intensities, etc.of different isotopes. The data for gamma ray transitions from the capture of thermal neutrons by 55Mn are not ingood agreement specifically below 2 MeV. So there is a need to re-estimate its intensities with better accuracy. Analyticalgrade MnCl2 powder and high purity Mn metal pieces were used in this study. Standard 152Eu and 60Co radioactivesources as well as thermal neutron capture γ-rays in chlorine were chosen for efficiency calibration. The k0standardization technique was applied for these measurements to eliminate systematic errors in efficiencies. Chlorinealso acted as a comparator in k0- factor calculations. The results have been tabulated for the main gamma rays from56Mn in the low as well as in the medium energy regions. The absolute intensities are in good agreement with most ofthe reported values.
基金supported by Natural Science Foundation of Beijing Municipality (Beijing Natural Science Foundation)(No.7191005)。
文摘Compton camera-based prompt gamma(PG) imaging has been proposed for range verification during proton therapy. However, a deviation between the PG and dose distributions, as well as the difference between the reconstructed PG and exact values, limit the effectiveness of the approach in accurate range monitoring during clinical applications. The aim of the study was to realize a PG-based dose reconstruction with a Compton camera, thereby further improving the prediction accuracy of in vivo range verification and providing a novel method for beam monitoring during proton therapy. In this paper, we present an approach based on a subset-driven origin ensemble with resolution recovery and a double evolutionary algorithm to reconstruct the dose depth profile(DDP) from the gamma events obtained by a cadmium-zinc-telluride Compton camera with limited position and energy resolution. Simulations of proton pencil beams with clinical particle rate irradiating phantoms made of different materials and the CT-based thoracic phantom were used to evaluate the feasibility of the proposed method. The results show that for the monoenergetic proton pencil beam irradiating homogeneous-material box phantom,the accuracy of the reconstructed DDP was within 0.3 mm for range prediction and within 5.2% for dose prediction. In particular, for 1.6-Gy irradiation in the therapy simulation of thoracic tumors, the range deviation of the reconstructed spreadout Bragg peak was within 0.8 mm, and the relative dose deviation in the peak area was less than 7% compared to the exact values. The results demonstrate the potential and feasibility of the proposed method in future Compton-based accurate dose reconstruction and range verification during proton therapy.