期刊文献+
共找到957篇文章
< 1 2 48 >
每页显示 20 50 100
Prostate Cancer Detection with Multiparametric Magnetic Resonance Imaging: Prostate Imaging Reporting and Data System Version 1 versus Version 2 被引量:12
1
作者 Zhao-Yan Feng Liang Wang +3 位作者 Xiang-De Min Shao-Gang Wang Guo-Ping Wang Jie Cai 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第20期2451-2459,共9页
Background:Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis.The American C... Background:Prostate Imaging Reporting and Data System (PI-RADS) is a globally acceptable standardization for multiparametric magnetic resonance imaging (mp-MRI) in prostate cancer (PCa) diagnosis.The American College of Radiology revised the PI-RADS to address the limitations of version 1 in December 2014.This study aimed to determine whether the PI-RADS version 2 (PI-RADS v2) scoring system improves the diagnostic accuracy of mp-MRI of the prostate compared with PI-RADS v1.Methods:This retrospective study was approved by the institutional review board.A total of 401 consecutive patients,with clinically suspicious Pca undergoing 3.0 T mp-MRI (T2-weighted imaging + diffusion-weighted imaging + DCE) before transrectal ultrasound-guided biopsy between June 2013 and July 2015,were included in the study.All patients were scored using the 5-point PI-RADS scoring system based on either PI-RADS v1 or v2.Receiver operating characteristics were calculated for statistical analysis.Sensitivity,specificity,and diagnostic accuracy were compared using McNemar's test.Results:Pca was present in 150 of 401 (37.41%) patients.When we pooled data from both peripheral zone (PZ) and transition zone (TZ),the areas under the curve were 0.889 for PI-RADS v1 and 0.942 for v2 (P =0.0001).Maximal accuracy was achieved with a score threshold of 4.At this threshold,in the PZ,similar sensitivity,specificity,and accuracy were achieved with v 1 and v2 (all P 〉 0.05).In the TZ,sensitivity was higher for v2 than for v1 (96.36% vs.76.36%,P =0.003),specificity was similar for v2 and v1 (90.24% vs.84.15%,P =0.227),and accuracy was higher for v2 than for v1 (92.70% vs.81.02%,P =0.002).Conclusions:Both v1 and v2 showed good diagnostic performance for the detection of Pca.However,in the TZ,the performance was better with v2 than with v1. 展开更多
关键词 Multiparametric Magnetic Resonance imaging prostate prostate imaging reporting and data system Version 1 prostate imaging reporting and data system Version 2
原文传递
Using the Prostate Imaging Reporting and Data System version 2 (PI-RIDS v2) to detect prostate cancer can prevent unnecessary biopsies and invasive treatment 被引量:13
2
作者 Chang Liu Shi-Liang Liu +5 位作者 Zhi-Xian Wang Kai Yu Chun-Xiang Feng Zan Ke Liang Wang Xiao-Yong Zeng 《Asian Journal of Andrology》 SCIE CAS CSCD 2018年第5期459-464,共6页
Prostate cancer (PCa) is one of the most common cancers among men globally. The authors aimed to evaluate the ability of the Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) to classify men with P... Prostate cancer (PCa) is one of the most common cancers among men globally. The authors aimed to evaluate the ability of the Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) to classify men with PCa, clinically significant PCa (CSPCa), or no PCa, especially among those with serum total prostate-specific antigen (tPSA) levels in the "gray zone" (4-10 ng ml-1). A total of 308 patients (355 lesions) were enrolled in this study. Diagnostic efficiency was determined. Univariate and multivariate analyses, receiver operating characteristic curve analysis, and decision curve analysis were performed to determine and compare the predictors of PCa and CSPCa. The results suggested that PI-RADS v2, tPSA, and prostate-specific antigen density (PSAD) were independent predictors of PCa and CSPCa. A PI-RADS v2 score L≥4 provided high negative predictive values (91.39% for PCa and 95.69% for CSPCa). A model of PI-RADS combined with PSA and PSAD helped to define a high-risk group (PI-RADS score = 5 and PSAD L≥0 15 ng ml-1 cm-3, with tPSA in the gray zone, or PI-RADS score L≥4 with high tPSA level) with a detection rate of 96.1% for PCa and 93.0% for CSPCa while a low-risk group with a detection rate of 6.1% for PCa and 2.2% for CSPCa. It was concluded that the PI-RADS v2 could be used as a reliable and independent predictor of PCa and CSPCa. The combination of PI-RADS v2 score with PSA and PSAD could be helpful in the prediction and diagnosis of PCa and CSPCa and, thus, may help in preventing unnecessary invasive procedures. 展开更多
关键词 diagnosis multiparametric magnetic resonance imaging prostate cancer prostate imaging reporting and data systemversion 2 prostate-specific antigen prostate-specific antigen density
原文传递
Diagnostic Performance and Interobserver Consistency of the Prostate Imaging Reporting and Data System Version 2: A Study on Six Prostate Radiologists with Different Experiences from Half a Year to 17 Years 被引量:1
3
作者 Zan Ke Liang Wang +6 位作者 Xiang-De Min Zhao-Yan Feng Zhen Kang Pei-Pei Zhang Ba-Sen Li Hui-Juan You Sheng-Chao Hou 《Chinese Medical Journal》 SCIE CAS CSCD 2018年第14期1666-1673,共8页
Background: One of the main aims of the updated Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) is to diminish variation in the interpretation and reporting of prostate imaging, especially among r... Background: One of the main aims of the updated Prostate Imaging Reporting and Data System Version 2 (PI-RADS v2) is to diminish variation in the interpretation and reporting of prostate imaging, especially among readers with varied experience levels. This study aimed to retrospectively analyze diagnostic consistency and accuracy for prostate disease among six radiologists with different experience levels from a single center and to evaluate the diagnostic pcrformance of PI-RADS v2 scores in the detection of clinically significant prostate cancer (PCa). Methods: From December 2014 to March 2016, 84 PCa patients and 99 benign prostatic shyperplasia patients who underwent 3.0T multiparametric magnetic resonance imaging before biopsy were included in our study. All patients received evaluation according to the PI-RADS v2 scale (1 5 scores) from six blinded readers (with 6 months and 2, 3, 4, 5, or 17 years of experience, respectively, the last reader was a reviewer/contributor for the PI-RADS v2). The correlation among the readers' scores and the Gleason score (GS) was determined with the Kendall test. lntra-/inter-observer agreement was evaluated using K statistics, while receiver operating characteristic curve and area under the curve analyses were performed to evaluate the diagnostic performance of the scores. Results: Based on the PI-RADS v2, the median k score and standard error among all possible pairs of readers were 0.506 and 0.043, respectively: the average correlation between the six readers' scores and the GS was positive, exhibiting weak-to-moderate strength (r = 0.391, P = 0.006). The AUC values of the six radiologists were 0.883, 0.924, 0.927, 0.932, 0.929, and 0.947, respectively. Conclusion: The inter-reader agreement for the PI-RADS v2 among the six readers with different experience is weak to moderate. Different experience levels affect the interpretation of MRI images. 展开更多
关键词 Benign Prostatic Hyperplasia Diagnosis Magnetic Resonance imaging prostate Cancer prostate imaging reporting anddata system Version 2
原文传递
Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions 被引量:17
4
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期610-617,共8页
AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesion... AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesions classified as BI-RADS 4 on conventional ultrasound were evaluated. CEUS was performed within one week before core needle biopsy or surgical resection and a revised BI-RADS classification was assigned based on 10 CEUS imaging characteristics. Receiver operating characteristic curve analysis was then conducted to evaluate the diagnostic performance of CEUS-based BI-RADS assignment with pathological examination as reference criteria. RESULTS: The CEUS-based BI-RADS evaluation classified 116/235(49.36%) lesions into category 3, 20(8.51%), 13(5.53%) and 12(5.11%) lesions into categories 4A, 4B and 4C, respectively, and 74(31.49%) into category 5. Selecting CEUS-based BI-RADS category 4A as an appropriate cut-off gave sensitivity and specificity values of 85.4% and 87.8%, respectively, for the diagnosisof malignant disease. The cancer-to-biopsy yield was 73.11% with CEUS-based BI-RADS 4A selected as the biopsy threshold compared with 40.85% otherwise, while the biopsy rate was only 42.13% compared with 100% otherwise. Overall, only 4.68% of invasive cancers were misdiagnosed.CONCLUSION: This pilot study suggests that evaluation of BI-RADS 4 breast lesions with CEUS results in reduced biopsy rates and increased cancer-to-biopsy yields. 展开更多
关键词 BREAST imaging reporting and data system CONTRAST-ENHANCED ultrasound BIOPSY False POSITIVE BIOPSY
下载PDF
Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions? 被引量:10
5
作者 Jun Luo Ji-Dong Chen +6 位作者 Qing Chen Lin-Xian Yue Guo Zhou Cheng Lan Yi Li Chi-Hua Wu Jing-Qiao Lu 《World Journal of Radiology》 CAS 2016年第6期600-609,共10页
AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(B... AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(BI-RADS) 4 solid breast lesions were imaged via CEUS before core needle biopsy or surgical resection. CEUS results were analyzed on 10 enhancing patterns to evaluate diagnostic performance of three benign and three malignant CEUS models, with pathological results used as the gold standard. A logistic regression model was developed basing on the CEUS results, and then evaluated with receiver operating curve(ROC). RESULTS: Except in cases of enhanced homogeneity, the rest of the 9 enhancement appearances were statistically significant(P < 0.05). These 9 enhancement patterns were selected in the final step of the logistic regression analysis, with diagnostic sensitivity and specificity of 84.4% and 82.7%, respectively, and the area under the ROC curve of 0.911. Diagnostic sensitivity, specificity, and accuracy of the malignant vs benign CEUS models were 84.38%, 87.77%, 86.38% and 86.46%, 81.29% and 83.40%, respectively. CONCLUSION: The breast CEUS models can predict risk of malignant breast lesions more accurately, decrease false-positive biopsy, and provide accurate BIRADS classification. 展开更多
关键词 BREAST CONTRAST-ENHANCED ultrasound Qualitative analysis BREAST imaging reporting and data system PREDICTIVE model
下载PDF
Magnetic resonance imaging ancillary features used in Liver Imaging Reporting and Data System:An illustrative review 被引量:3
6
作者 David Campos-Correia Joao Cruz +2 位作者 António P Matos Filipa Figueiredo Miguel Ramalho 《World Journal of Radiology》 CAS 2018年第2期9-23,共15页
Hepatocellular carcinoma (HCC) usually develops in the setting of chronic liver disease. In the adequate clinical context, both multiphasic contrast-enhanced CT and magnetic resonance imaging are non-invasive modaliti... Hepatocellular carcinoma (HCC) usually develops in the setting of chronic liver disease. In the adequate clinical context, both multiphasic contrast-enhanced CT and magnetic resonance imaging are non-invasive modalities that allow accurate diagnosis and staging of HCC, although the latter demonstrates greater sensitivity and specificity. Imaging criteria for HCC diagnosis rely on hemodynamic features such as hyperenhancement in the arterial phase and washout in the portal or equilibrium phase. However, imaging performance drops considerably for small (< 20 mm) nodules because their tendency to exhibit atypical enhancement patterns. In order to improve accuracy in the diagnosis and staging of HCC, particularly in cases of atypical nodules, ancillary features, i.e., imaging characteristics that modify the likelihood of HCC, have been described and incorporated into clinical reports, especially in Liver Imaging Reporting and Data System. In this paper, ancillary imaging features will be reviewed and illustrated. 展开更多
关键词 HEPATOCELLULAR carcinoma Ancillary FEATURES Magnetic resonance imaging LIVER imaging reporting and data system CIRRHOSIS LIVER
下载PDF
Contrast-enhanced ultrasound Liver Imaging Reporting and Data System:Lights and shadows in hepatocellular carcinoma and cholangiocellular carcinoma diagnosis 被引量:3
7
作者 Gianpaolo Vidili Marco Arru +13 位作者 Giuliana Solinas Diego Francesco Calvisi Pierluigi Meloni Assunta Sauchella Davide Turilli Claudio Fabio Antonio Cossu Giordano Madeddu Sergio Babudieri Maria Assunta Zocco Giovanni Iannetti Enza Di Lembo Alessandro Palmerio Delitala Roberto Manetti 《World Journal of Gastroenterology》 SCIE CAS 2022年第27期3488-3502,共15页
BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the ris... BACKGROUND Contrast-enhanced ultrasound(CEUS)is considered a secondary examination compared to computed tomography(CT)and magnetic resonance imaging(MRI)in the diagnosis of hepatocellular carcinoma(HCC),due to the risk of misdiagnosing intrahepatic cholangiocarcinoma(ICC).The introduction of CEUS Liver Imaging Reporting and Data System(CEUS LI-RADS)might overcome this limitation.Even though data from the literature seems promising,its reliability in real-life context has not been well-established yet.AIM To test the accuracy of CEUS LI-RADS for correctly diagnosing HCC and ICC in cirrhosis.METHODS CEUS LI-RADS class was retrospectively assigned to 511 nodules identified in 269 patients suffering from liver cirrhosis.The diagnostic standard for all nodules was either biopsy(102 nodules)or CT/MRI(409 nodules).Common diagnostic accuracy indexes such as sensitivity,specificity,positive predictive value(PPV),and negative predictive value(NPV)were assessed for the following associations:CEUS LR-5 and HCC;CEUS LR-4 and 5 merged class and HCC;CEUS LR-M and ICC;and CEUS LR-3 and malignancy.The frequency of malignant lesions in CEUS LR-3 subgroups with different CEUS patterns was also determined.Inter-rater agreement for CEUS LI-RADS class assignment and for major CEUS pattern identification was evaluated.RESULTS CEUS LR-5 predicted HCC with a 67.6%sensitivity,97.7%specificity,and 99.3%PPV(P<0.001).The merging of LR-4 and 5 offered an improved 93.9%sensitivity in HCC diagnosis with a 94.3%specificity and 98.8%PPV(P<0.001).CEUS LR-M predicted ICC with a 91.3%sensitivity,96.7%specificity,and 99.6%NPV(P<0.001).CEUS LR-3 predominantly included benign lesions(only 28.8%of malignancies).In this class,the hypo-hypo pattern showed a much higher rate of malignant lesions(73.3%)than the iso-iso pattern(2.6%).Inter-rater agreement between internal raters for CEUS-LR class assignment was almost perfect(n=511,k=0.94,P<0.001),while the agreement among raters from separate centres was substantial(n=50,k=0.67,P<0.001).Agreement was stronger for arterial phase hyperenhancement(internal k=0.86,P<2.7×10-214;external k=0.8,P<0.001)than washout(internal k=0.79,P<1.6×10-202;external k=0.71,P<0.001).CONCLUSION CEUS LI-RADS is effective but can be improved by merging LR-4 and 5 to diagnose HCC and by splitting LR-3 into two subgroups to differentiate iso-iso nodules from other patterns. 展开更多
关键词 Contrast-enhanced ultrasound Liver imaging reporting and data system Hepatocellular carcinoma Intrahepatic cholangiocarcinoma CIRRHOSIS Contrast-enhanced ultrasound LIVER
下载PDF
Interobserver agreement for contrast-enhanced ultrasound of liver imaging reporting and data system:A systematic review and metaanalysis 被引量:2
8
作者 Jun Li Ming Chen +7 位作者 Zi-Jing Wang Shu-Gang Li Meng Jiang Long Shi Chun-Li Cao Tian Sang Xin-Wu Cui Christoph F Dietrich 《World Journal of Clinical Cases》 SCIE 2020年第22期5589-5602,共14页
BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisf... BACKGROUND Hepatocellular carcinoma is the most common primary liver malignancy.From the results of previous studies,Liver Imaging Reporting and Data System(LIRADS)on contrast-enhanced ultrasound(CEUS)has shown satisfactory diagnostic value.However,a unified conclusion on the interobserver stability of this innovative ultrasound imaging has not been determined.The present metaanalysis examined the interobserver agreement of CEUS LI-RADS to provide some reference for subsequent related research.AIM To evaluate the interobserver agreement of LI-RADS on CEUS and analyze the sources of heterogeneity between studies.METHODS Relevant papers on the subject of interobserver agreement on CEUS LI-RADS published before March 1,2020 in China and other countries were analyzed.The studies were filtered,and the diagnostic criteria were evaluated.The selected references were analyzed using the“meta”and“metafor”packages of R software version 3.6.2.RESULTS Eight studies were ultimately included in the present analysis.Meta-analysis results revealed that the summary Kappa value of included studies was 0.76[95%confidence interval,0.67-0.83],which shows substantial agreement.Higgins I2 statistics also confirmed the substantial heterogeneity(I2=91.30%,95%confidence interval,85.3%-94.9%,P<0.01).Meta-regression identified the variables,including the method of patient enrollment,method of consistency testing,and patient race,which explained the substantial study heterogeneity.CONCLUSION CEUS LI-RADS demonstrated overall substantial interobserver agreement,but heterogeneous results between studies were also obvious.Further clinical investigations should consider a modified recommendation about the experimental design. 展开更多
关键词 Contrast-enhanced ultrasound Liver imaging reporting and data system Interobserver agreement systematic review DIAGNOSIS META-ANALYSIS
下载PDF
Hepatocellular carcinoma Liver Imaging Reporting and Data Systems treatment response assessment: Lessons learned and future directions 被引量:2
9
作者 Anum Aslam Richard Kinh Gian Do +7 位作者 Avinash Kambadakone Bradley Spieler Frank H Miller Ahmed M Gabr Resmi A Charalel Charles Y Kim David C Madoff Mishal Mendiratta-Lala 《World Journal of Hepatology》 CAS 2020年第10期738-753,共16页
Hepatocellular carcinoma(HCC)is a leading cause of morbidity and mortality worldwide,with rising clinical and economic burden as incidence increases.There are a multitude of evolving treatment options,including locore... Hepatocellular carcinoma(HCC)is a leading cause of morbidity and mortality worldwide,with rising clinical and economic burden as incidence increases.There are a multitude of evolving treatment options,including locoregional therapies which can be used alone,in combination with each other,or in combination with systemic therapy.These treatment options have shown to be effective in achieving remission,controlling tumor progression,improving disease free and overall survival in patients who cannot undergo resection and providing a bridge to transplant by debulking tumor burden to downstage patients.Following locoregional therapy(LRT),it is crucial to provide treatment response assessment to guide management and liver transplant candidacy.Therefore,Liver Imaging Reporting and Data Systems(LI-RADS)Treatment Response Algorithm(TRA)was created to provide a standardized assessment of HCC following LRT.LIRADS TRA provides a step by step approach to evaluate each lesion independently for accurate tumor assessment.In this review,we provide an overview of different locoregional therapies for HCC,describe the expected post treatment imaging appearance following treatment,and review the LI-RADS TRA with guidance for its application in clinical practice.Unique to other publications,we will also review emerging literature supporting the use of LI-RADS for assessment of HCC treatment response after LRT. 展开更多
关键词 Hepatocellular carcinoma Liver imaging reporting and data systems Treatment Response Algorithm Locoregional therapy Liver imaging reporting and data systems Treatment Response equivocal Arterial phase hyper enhancement Stereotactic body radiotherapy
下载PDF
Liver Imaging Reporting and Data System criteria for the diagnosis of hepatocellular carcinoma in clinical practice: A pictorial minireview 被引量:1
10
作者 Christina Liava Emmanouil Sinakos +9 位作者 Elissavet Papadopoulou Lamprini Giannakopoulou Stamatia Potsi Anestis Moumtzouoglou Anthi Chatziioannou Loukas Stergioulas Lydia Kalogeropoulou Ioannis Dedes Evangelos Akriviadis Danai Chourmouzi 《World Journal of Gastroenterology》 SCIE CAS 2022年第32期4540-4556,共17页
Hepatocellular carcinoma(HCC)is the sixth most common cancer.The main risk factors associated with HCC development include hepatitis B virus,hepatitis C virus,alcohol consumption,aflatoxin B1,and nonalcoholic fatty li... Hepatocellular carcinoma(HCC)is the sixth most common cancer.The main risk factors associated with HCC development include hepatitis B virus,hepatitis C virus,alcohol consumption,aflatoxin B1,and nonalcoholic fatty liver disease.However,hepatocarcinogenesis is a complex multistep process.Various factors lead to hepatocyte malignant transformation and HCC development.Diagnosis and surveillance of HCC can be made with the use of liver ultrasound(US)every 6 mo.However,the sensitivity of this imaging method to detect HCC in a cirrhotic liver is limited,due to the abnormal liver parenchyma.Computed tomography(CT)and magnetic resonance imaging(MRI)are considered to be most useful tools for at-risk patients or patients with inadequate US.Liver biopsy is still used for diagnosis and prognosis of HCC in specific nodules that cannot be definitely characterized as HCC by imaging.Recently the American College of Radiology designed the Liver Imaging Reporting and Data System(LI-RADS),which is a comprehensive system for standardized interpretation of CT and MRI liver examinations that was first proposed in 2011.In 2018,it was integrated into the American Association for the Study of Liver Diseases guidance statement for HCC.LI-RADS is designed to ensure high sensitivity,precise categorization,and high positive predictive value for the diagnosis of HCC and is applied to“highrisk populations”according to specific criteria.Most importantly LI-RADS criteria achieved international collaboration and consensus among liver experts around the world on the best practices for caring for patients with or at risk for HCC. 展开更多
关键词 Hepatocellular carcinoma HEPATOCARCINOGENESIS Computed tomography Magnetic resonance imaging Liver imaging reporting and data system
下载PDF
Validation of Vesical Imaging Reporting and Data System score for the diagnosis of muscle-invasive bladder cancer: A prospective cross-sectional study 被引量:1
11
作者 Kumawat Ghanshyam Vyas Nachiket +4 位作者 Sharma Govind Priyadarshi Shivam Gupta Bhagwan Sahay Singla Mohit Kumar Ashok 《Asian Journal of Urology》 CSCD 2022年第4期467-472,共6页
Objective:Vesical Imaging Reporting and Data System(VIRADS)score was developed to standardize the reporting and staging of bladder tumors on pre-operative multiparametric magnetic resonance imaging.It helps in avoidin... Objective:Vesical Imaging Reporting and Data System(VIRADS)score was developed to standardize the reporting and staging of bladder tumors on pre-operative multiparametric magnetic resonance imaging.It helps in avoiding unnecessary repeat transurethral resection of bladder tumor in high-risk non-muscle-invasive bladder cancer patients.This study was done to determine the validity of VIRADS score prospectively for the diagnosis of muscleinvasive bladder cancer.Methods:This study was conducted from March 2019 to March 2020 at Sawai Man Singh Medical College and Hospital,Jaipur,Rajasthan,India.Patients admitted with the provisional diagnosis of bladder tumor were included as participants.All these patients underwent a 3 Tesla mpMRI to obtain a VIRADS score before they underwent transurethral resection of bladder tumor and these data were analyzed to evaluate the correlation of pre-operative VIRADS score with mus-cle invasiveness of the tumor in final biopsy report.Results:A cut-off of VIRADS≥4 for prediction of detrusor muscle invasion yielded a sensitivity of 79.4%,specificity of 94.2%,positive predictive value of 90.0%,negative predictive value of 87.5%,and diagnostic accuracy of 86.4%.A cut off of VIRADS≥3 for prediction of detrusor muscle invasion yielded a sensitivity of 91.2%,specificity of 78.8%,positive predictive value of 73.8%,negative predictive value of 93.2%,and accuracy of 83.7%.The receiver operating curve showed the area under the curve to be 0.922(95%confidence interval:0.862e0.983).Conclusion:VIRADS score appears to be an excellent and effective pre-operative radiological tool for the prediction of detrusor muscle invasion in bladder cancer. 展开更多
关键词 Vesical imaging reporting and data system Bladder tumor Multiparametric magnetic resonance imaging Detrusor invasion
下载PDF
Effect of training on resident inter-reader agreement with American College of Radiology Thyroid Imaging Reporting and Data System
12
作者 Yang Du Meredith Bara +6 位作者 Prayash Katlariwala Roger Croutze Katrin Resch Jonathan Porter Medica Sam Mitchell P Wilson Gavin Low 《World Journal of Radiology》 2022年第1期19-29,共11页
BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS re... BACKGROUND The American College of Radiology Thyroid Imaging Reporting and Data System(ACR TI-RADS)was introduced to standardize the ultrasound characterization of thyroid nodules.Studies have shown that ACR-TIRADS reduces unnecessary biopsies and improves consistency of imaging recommendations.Despite its widespread adoption,there are few studies to date assessing the inter-reader agreement amongst radiology trainees with limited ultrasound experience.We hypothesize that in PGY-4 radiology residents with no prior exposure to ACR TIRADS,a statistically significant improvement in inter-reader reliability can be achieved with a one hour training session.AIM To evaluate the inter-reader agreement of radiology residents in using ACR TIRADS before and after training.METHODS A single center retrospective cohort study evaluating 50 thyroid nodules in 40 patients of varying TI-RADS levels was performed.Reference standard TI-RADS scores were established through a consensus panel of three fellowship-trained staff radiologists with between 1 and 14 years of clinical experience each.Three PGY-4 radiology residents(trainees)were selected as blinded readers for this study.Each trainee had between 4 to 5 mo of designated ultrasound training.No trainee had received specialized TI-RADS training prior to this study.Each of the readers independently reviewed the 50 testing cases and assigned a TI-RADS score to each case before and after TI-RADS training performed 6 wk apart.Fleiss kappa was used to measure the pooled inter-reader agreement.The relative diagnostic performance of readers,pre-and post-training,when compared against the reference standard.RESULTS There were 33 females and 7 males with a mean age of 56.6±13.6 years.The mean nodule size was 19±14 mm(range from 5 to 63 mm).A statistically significant superior inter-reader agreement was found on the post-training assessment compared to the pre-training assessment for the following variables:1.“Shape”(k of 0.09[slight]pre-training vs 0.67[substantial]post-training,P<0.001),2.“Echogenic foci”(k of 0.28[fair]pre-training vs 0.45[moderate]post-training,P=0.004),3.‘TI-RADS level’(k of 0.14[slight]pre-training vs 0.36[fair]post-training,P<0.001)and 4.‘Recommendations’(k of 0.36[fair]pre-training vs 0.50[moderate]post-training,P=0.02).No significant differences between the preand post-training assessments were found for the variables'composition','echogenicity'and'margins'.There was a general trend towards improved pooled sensitivity with TI-RADS levels 1 to 4 for the post-training assessment while the pooled specificity was relatively high(76.6%-96.8%)for all TI-RADS level.CONCLUSION Statistically significant improvement in inter-reader agreement in the assigning TI-RADS level and recommendations after training is observed.Our study supports the use of dedicated ACR TI-RADS training in radiology residents. 展开更多
关键词 Thyroid Thyroid nodule American College of Radiology Thyroid imaging reporting and data system Inter-reader agreement Ultrasound
下载PDF
Prostate magnetic resonance imaging and the value of experience:An intrareader variability study
13
作者 Thomas Whish-Wilson Jo-Lynn Tan +2 位作者 William Cross Lih-Ming Wong Tom Sutherland 《Asian Journal of Urology》 CSCD 2023年第4期488-493,共6页
Objective To measure the intraobserver concordance of an experienced genitourinary radiologist reporting of multiparametric magnetic resonance imaging of the prostate(mpMRIp)scans over time.Methods An experienced geni... Objective To measure the intraobserver concordance of an experienced genitourinary radiologist reporting of multiparametric magnetic resonance imaging of the prostate(mpMRIp)scans over time.Methods An experienced genitourinary radiologist re-reported his original 100 consecutive mpMRIp scans using Prostate Imaging-Reporting and Data System version 2(PI-RADS v2)after 5 years of further experience comprising>1000 scans.Intraobserver agreement was measured using Cohen's kappa.Sensitivity,specificity,negative predictive value(NPV),positive predictive value(PPV),and accuracy were calculated,and comparison of sensitivity was performed using McNemar's test.Results Ninety-six mpMRIp scans were included in our final analysis.Of the 96 patients,53(55.2%)patients underwent subsequent biopsy(n=43)or prostatectomy(n=15),with 73 lesions targeted.Moderate agreement(Cohen's kappa 0.55)was seen in the number of lesions identified at initial reporting and on re-reading(81 vs.39 total lesions;and 71 vs.37 number of PI-RADS≥3 lesions).For clinically significant prostate cancer,re-reading demonstrated an increase in specificity(from 43%to 89%)and PPV(from 62%to 87%),but a decrease in sensitivity(from 94%to 72%,p=0.01)and NPV(from 89%to 77%).Conclusion The intraobserver agreement for a novice to experienced radiologist reporting mpMRIp using PI-RADS v2 is moderate.Reduced sensitivity is off-set by improved specificity and PPV,which validate mpMRIp as a gold standard for prebiopsy screening. 展开更多
关键词 prostate cancer Magneticresonance imaging prostate imaging-reporting and data system Intrareader prostate biopsy
下载PDF
Granulomatous prostatitis after bacille Calmette-Guérin instillation resembles prostate carcinoma:A case report and review of the literature
14
作者 Yu Yao Jun-Jie Ji +2 位作者 Hai-Yun Wang Li-Jiang Sun Gui-Ming Zhang 《World Journal of Clinical Cases》 SCIE 2023年第9期2051-2059,共9页
BACKGROUND Bacille Calmette-Guérin(BCG)instillation is recommended in patients with nonmuscle-invasive bladder cancer who have intermediate-risk and high-risk tumors.However,granulomatous prostatitis is a rare co... BACKGROUND Bacille Calmette-Guérin(BCG)instillation is recommended in patients with nonmuscle-invasive bladder cancer who have intermediate-risk and high-risk tumors.However,granulomatous prostatitis is a rare complication induced by BCG instillation,which can easily be misdiagnosed as prostate cancer.Here,we report a case of granulomatous prostatitis that resembled prostate cancer.CASE SUMMARY A 64-year-old Chinese man with bladder cancer received BCG instillation.Three days later,he stopped BCG instillation and received anti-infective therapy due to the urinary tract infection.Three months after BCG restart,he had rising total prostate-specific antigen(PSA)(9.14 ng/mL)and decreasing free PSA/total PSA(0.09).T2-weighted images of magnetic resonance imaging(MRI)showed a 28 mm×20 mm diffuse low signal abnormality in the right peripheral zone,which was markedly hyperintense on high b-value diffusion-weighted MRI and hypointense on apparent diffusion coefficient map images.Considering Prostate Imaging Reporting and Data System score of 5 and possibility of prostate cancer,a prostate biopsy was conducted.Histopathology showed typical features of granulomatous prostatitis.The nucleic acid test for tuberculosis was positive.He was finally diagnosed with BCG-induced granulomatous prostatitis.Thereafter,he stopped BCG instillation and received anti-tuberculosis treatment.During 10 mo follow-up,he had no evidence of tumor recurrence or symptoms of tuberculosis.CONCLUSION Temporarily elevated PSA and high followed by low signal abnormality on diffusion-weighted MRI are important indicators of BCG-induced granulomatous prostatitis. 展开更多
关键词 Granulomatous prostatitis prostate cancer Bacille Calmette-Guérin Magnetic resonance imaging prostate-specific antigen Case report
下载PDF
Evaluation of the Prostate Imaging Reporting and Data System for Magnetic Resonance Imaging Diagnosis of Prostate Cancer in Patients with Prostate-specific Antigen 〈20 ng/ml 被引量:13
15
作者 Xuan Wang Jian-Ye Wang +8 位作者 Chun-Mei Li Ya-Qun Zhang Jian-Long Wang Ben Wan Wei Zhang Min Chen Sa-Ying Li Gang Wan Ming Liu 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第12期1432-1438,共7页
Background: The European Society of Urogenital Radiology has built the Prostate Imaging Reporting and Data System (PI-RADS) for standardizing the diagnosis of prostate cancer (PCa). This study evaluated the PI-RA... Background: The European Society of Urogenital Radiology has built the Prostate Imaging Reporting and Data System (PI-RADS) for standardizing the diagnosis of prostate cancer (PCa). This study evaluated the PI-RADS diagnosis method in patients with prostate-specific antigen (PSA) 〈20 ng/ml. Methods: A total of 133 patients with PSA 〈20 ng/ml were prospectively recruited. T2-weighted (T2WI) and diffusion-weighted (DWI) magnetic resonance images of the prostate were acquired before a 12-core transrectal prostate biopsy. Each patient's peripheral zone was divided into six regions on the images; each region corresponded to two of the 12 biopsy cores. T2WI, DWI, and T2W1 + DWI scores were computed according to PI-RADS. The diagnostic accuracy of the PI-RADS score was evaluated using histopathology of prostate biopsies as the reference standard. Results: PCa was histologically diagnosed in 169 (21.2%) regions. Increased PI-RADS score correlated positively with increased cancer detection rate. The cancer detection rate for scores 1 to 5 was 2.8%, 15.0%, 34.6%, 52.6%, and 88.9%, respectively, using T2W1 and 12.0%, 20.2%, 48.0%, 85.7%, and 93.3%, respectively, using DWI. For T2WI + DWI, the cancer detection rate was 1.5% (score 2), 13.5% (scores 3-4), 41.3% (scores 5-6), 75.9% (scores 7-8), and 92.3% (scores 9-10). The area under the curve for cancer detection was 0.700 (T2WI), 0.735 (DWI) and 0.749 (T2WI + DWI). The sensitivity and specificity were 53.8% and 89.2%, respectively, when The summed score ofT2Wl + DWI 展开更多
关键词 Diagnosis Magnetic Resonance imaging prostate Cancer prostate imaging reporting and data system
原文传递
Hepatocellular carcinoma: Can LI-RADS v2017 with gadoxetic-acid enhancement magnetic resonance and diffusion-weighted imaging improve diagnostic accuracy? 被引量:6
16
作者 Tong Zhang Zi-Xing Huang +8 位作者 Yi Wei Han-Yu Jiang Jie Chen Xi-Jiao Liu Li-Kun Cao Ting Duan Xiao-Peng He Chun-Chao Xia Bin Song 《World Journal of Gastroenterology》 SCIE CAS 2019年第5期622-631,共10页
BACKGROUND The Liver Imaging Reporting and Data System(LI-RADS), supported by the American College of Radiology(ACR), has been developed for standardizing the acquisition, interpretation, reporting, and data collectio... BACKGROUND The Liver Imaging Reporting and Data System(LI-RADS), supported by the American College of Radiology(ACR), has been developed for standardizing the acquisition, interpretation, reporting, and data collection of liver imaging examinations in patients at risk for hepatocellular carcinoma(HCC). Diffusionweighted imaging(DWI), which is described as an ancillary imaging feature of LI-RADS, can improve the diagnostic efficiency of LI-RADS v2017 with gadoxetic acid-enhanced magnetic resonance imaging(MRI) for HCC.AIM To determine whether the use of DWI can improve the diagnostic efficiency of LIRADS v2017 with gadoxetic acid-enhanced magnetic resonance MRI for HCC.METHODS In this institutional review board-approved study, 245 observations of high risk of HCC were retrospectively acquired from 203 patients who underwent gadoxetic acid-enhanced MRI from October 2013 to April 2018. Two readers independently measured the maximum diameter and recorded the presence of each lesion and assigned scores according to LI-RADS v2017. The test was used to determine the agreement between the two readers with or without DWI. In addition, the sensitivity(SE), specificity(SP), accuracy(AC), positive predictive value(PPV), and negative predictive value(NPV) of LI-RADS were calculated.Youden index values were used to compare the diagnostic performance of LIRADS with or without DWI.RESULTS Almost perfect interobserver agreement was obtained for the categorization of observations with LI-RADS(kappa value: 0.813 without DWI and 0.882 with DWI). For LR-5, the diagnostic SE, SP, and AC values were 61.2%, 92.5%, and71.4%, respectively, with or without DWI; for LR-4/5, they were 73.9%, 80%, and75.9% without DWI and 87.9%, 80%, and 85.3% with DWI; for LR-4/5/M, they were 75.8%, 58.8%, and 70.2% without DWI and 87.9%, 58.8%, and 78.4% with DWI; for LR-4/5/TIV, they were 75.8%, 75%, and 75.5% without DWI and 89.7%,75%, and 84.9% with DWI. The Youden index values of the LI-RADS classification without or with DWI were as follows: LR-4/5: 0.539 vs 0.679; LR-4/5/M: 0.346 vs 0.467; and LR-4/5/TIV: 0.508 vs 0.647.CONCLUSION LI-RADS v2017 has been successfully applied with gadoxetate-enhanced MRI for patients at high risk for HCC. The addition of DWI significantly increases the diagnostic efficiency for HCC. 展开更多
关键词 HEPATOCELLULAR CARCINOMA Liver imaging reporting and data system Magnetic RESONANCE imaging DIFFUSION-WEIGHTED imaging Diagnosis
下载PDF
BRAF^(V600E) vs. TIRADS in predicting papillary thyroid cancers in Bethesda system Ⅰ, Ⅲ, and Ⅴ nodules 被引量:9
17
作者 Ya Wu Ting Xu +8 位作者 Xingyue Cao Xin Zhao Hongyan Deng Jianxiang Wang Xiao Li Qing Yao Xinhua Ye Meiping Shen Xiaohong Wu 《Cancer Biology & Medicine》 SCIE CAS CSCD 2019年第1期131-138,共8页
Objective: Bethesda System for Reporting Thyroid Cytopathology(BSRTC) categories Ⅰ, Ⅲ, and Ⅴaccount for a significant proportion of fine needle aspiration cytology(FNAC) diagnoses. This study aimed to compare the d... Objective: Bethesda System for Reporting Thyroid Cytopathology(BSRTC) categories Ⅰ, Ⅲ, and Ⅴaccount for a significant proportion of fine needle aspiration cytology(FNAC) diagnoses. This study aimed to compare the diagnostic efficacy of BRAF^(V600E) mutation and the Thyroid Imaging Reporting and Data System(TIRADS) classification in differentiating papillary thyroid cancers(PTCs) from benign lesions among BSRTC I, III, and V nodules.Methods: A total of 472 patients with 479 nodules were enrolled in this prospective study. Ultrasound, BRAF^(V600E) mutation testing, and FNAC were performed in each nodule, followed by surgery or regular ultrasound examination.Results: In the BSRTC I category, BRAF^(V600E) showed similar sensitivity, higher specificity, and lower accuracy when compared with TIRADS. In the BSRTC III/V category, the sensitivity, specificity, and accuracy of BRAF^(V600E) were similar to those of TIRADS. In comparison to BRAF^(V600E) alone, the combination of the two methods significantly improved sensitivity(BSRTC Ⅰ:93.6% vs. 67.7%, P < 0.01; BSRTC Ⅲ: 93.8% vs. 75.0%, P < 0.01; BSRTC V: 96.0% vs. 85.3%, P < 0.001). When compared with TIRADS alone, the combination improved sensitivity in BSRTC Ⅰ nodules(93.6% vs. 74.2%, P < 0.05), increased sensitivity and decreased accuracy in BSRTC III nodules(93.8% vs. 75.0%, P < 0.01, 91.0% vs. 93.6%, P < 0.01), and improved both sensitivity and accuracy in BSRTC V nodules(96.0% vs. 82.0%, P < 0.001; 94.2% vs. 81.3%, P < 0.001).Conclusions: BRAF^(V600E) exhibited higher specificity and lower accuracy compared with TIRADS in BSRTC Ⅰ nodules, while the two methods showed similar diagnostic value in BSRTC Ⅲ/Ⅴ nodules. The combination of the two methods distinctly improved sensitivity in the diagnosis of PTCs in BSRTC Ⅰ, Ⅲ, and Ⅴ nodules. 展开更多
关键词 PAPILLARY THYROID carcinoma FINE-NEEDLE aspiration cytology(FNAC) BRAFV600E THYROID imaging reporting and data system(TIRADS) BETHESDA classification
下载PDF
Practice patterns and outcomes of equivocal bone scans for patients with castration-resistant prostate cancer: Results from SEARCH
18
作者 Brian T.Hanyok Mary M.Everist +7 位作者 Lauren E.Howard Amanda M.De Hoedt William J.Aronson Matthew R.Cooperberg Christopher J.Kane Christopher L.Amling Martha K.Terris Stephen J.Freedland 《Asian Journal of Urology》 CSCD 2019年第3期242-248,共7页
Objective:To review follow-up imaging after equivocal bone scans in men with castration resistant prostate cancer(CRPC)and examine the characteristics of equivocal bone scans that are associated with positive follow-u... Objective:To review follow-up imaging after equivocal bone scans in men with castration resistant prostate cancer(CRPC)and examine the characteristics of equivocal bone scans that are associated with positive follow-up imaging.Methods:We identified 639 men from five Veterans Affairs Hospitals with a technetium-99m bone scan after CRPC diagnosis,of whom 99(15%)had equivocal scans.Men with equivocal scans were segregated into“high-risk”and“low-risk”subcategories based upon wording in the bone scan report.All follow-up imaging(bone scans,computed tomography[CT],magnetic resonance imaging[MRI],and X-rays)in the 3 months after the equivocal scan were reviewed.Variables were compared between patients with a positive vs.negative follow-up imaging after an equivocal bone scan.Results:Of 99 men with an equivocal bone scan,43(43%)received at least one follow-up imaging test,including 32/82(39%)with low-risk scans and 11/17(65%)with high-risk scans(p=0.052).Of follow-up tests,67%were negative,14%were equivocal,and 19%were positive.Among those who underwent follow-up imaging,3/32(9%)low-risk men had metastases vs.5/11(45%)high-risk men(p=0.015).Conclusion:While 19%of all men who received follow-up imaging had positive follow-up imaging,only 9%of those with a low-risk equivocal bone scan had metastases versus 45%of those with high-risk.These preliminary findings,if confirmed in larger studies,suggest follow-up imaging tests for low-risk equivocal scans can be delayed while high-risk equivocal scans should receive follow-up imaging. 展开更多
关键词 Castration-resistant prostate cancer Equivocal test result Bone scan Radiology report Follow-up imaging Neoplasm metastasis
下载PDF
Imaging related to underlying immunological and pathological processes in COVID-19
19
作者 Elena Ilieva Alexandra Boyapati +4 位作者 Lyubomir Chervenkov Milena Gulinac Jordan Borisov Kamelia Genova Tsvetelina Velikova 《World Journal of Clinical Infectious Diseases》 2022年第1期1-19,共19页
The introduction of coronavirus disease-2019(COVID-19)as a global pandemic has contributed to overall morbidity and mortality.With a focus on understanding the immunology and pathophysiology of the disease,these featu... The introduction of coronavirus disease-2019(COVID-19)as a global pandemic has contributed to overall morbidity and mortality.With a focus on understanding the immunology and pathophysiology of the disease,these features can be linked with the respective findings of imaging studies.Thus,the constellation between clinical presentation,histological,laboratory,immunological,and imaging results is crucial for the proper management of patients.The purpose of this article is to examine the role of imaging during the particular stages of severe acute respiratory syndrome coronavirus 2 infection–asymptomatic stage,typical and atypical COVID-19 pneumonia,acute respiratory distress syndrome,multiorgan failure,and thrombosis.The use of imaging methods to assess the severity and duration of changes is crucial in patients with COVID-19.Radiography and computed tomography are among the methods that allow accurate characterization of changes. 展开更多
关键词 Coronavirus disease-2019 Ultrasound Computed tomography Magnetic resonance imaging Ground-glass opacity Acute respiratory distress syndrome Cytokine storm COVID-19 reporting and data system High-resolution computed tomography Severe acute respiratory syndrome coronavirus 2
下载PDF
双参数与多参数MRI对前列腺特异性抗原灰区临床显著性前列腺癌诊断效能比较
20
作者 董喆 张云 +5 位作者 王海屹 刘百川 丁效蕙 郝雨薇 徐鸿昊 叶慧义 《国际医学放射学杂志》 2024年第3期328-334,共7页
目的探讨基于前列腺影像报告与数据系统2.1版(PI-RADS v2.1)的双参数MRI(bpMRI)与多参数MRI(mpMRI)对前列腺特异性抗原(PSA)灰区(PSA 4~10 ng/mL)临床显著性前列腺癌(csPCa)的诊断效能。方法回顾性纳入2家医疗中心接受前列腺活检术并完... 目的探讨基于前列腺影像报告与数据系统2.1版(PI-RADS v2.1)的双参数MRI(bpMRI)与多参数MRI(mpMRI)对前列腺特异性抗原(PSA)灰区(PSA 4~10 ng/mL)临床显著性前列腺癌(csPCa)的诊断效能。方法回顾性纳入2家医疗中心接受前列腺活检术并完成MRI检查的PSA灰区病人270例(中心1,220例;中心2,50例),分析病人的临床及MRI影像资料。根据Gleason评分将病人分为csPCa组(177例)和非csPCa组(93例)。基于PI-RADS v2.1标准,根据bpMRI(T2WI、DWI)与mpMRI(T2WI、DWI和DCE-MRI)对每例病人的病灶进行评分。采用独立样本t检验、Mann-Whitney U检验、χ2检验比较2组病人的一般资料[年龄、PSA、前列腺体积(PV)、PSA密度(PSAD)]、bpMRI评分和mpMRI评分。以前列腺活检病理结果为标准,绘制受试者操作特征(ROC)曲线,计算其曲线下面积(AUC)、敏感度、特异度、准确度。采用DeLong检验比较2种评分方法对csPCa的诊断效能。采用McNemar检验比较2种评分方法的敏感度和特异度。采用Kappa检验分析2名医师评估bpMRI和mpMRI评分的一致性。结果相比非csPCa组,csPCa组的PV更小、PSAD更高(均P<0.05)。csPCa组中bpMRI与mpMRI评分为4-5分病人的占比更高(76.8%和85.3%),非csPCa组中1-3分病人的占比更高(78.5%和74.2%)。bpMRI与mpMRI评分诊断csPCa的AUC值差异无统计学意义(P>0.05)。bpMRI的敏感度低于mpMRI(76.8%和85.3%,P<0.05),而特异度高于mpMRI(78.5%和74.2%,P<0.05)。bpMRI和mpMRI评分的阅片者间一致性均较好(κ=0.68和κ=0.67)。结论基于PI-RADS v2.1,bpMRI评分与mpMRI评分对PSA灰区csPCa的诊断效能相近。 展开更多
关键词 前列腺影像报告与数据系统 磁共振成像 临床显著性前列腺癌
下载PDF
上一页 1 2 48 下一页 到第
使用帮助 返回顶部