期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
United States Law on the Protection of Abused and Neglected Children
1
作者 MARK HARDIN 《The Journal of Human Rights》 2007年第5期32-36,共5页
I. Introduction This paper discusses child protection in the United States. I will discuss four general topics. The first topic is United States laws on the protection of children from child abuse and neglect. The se... I. Introduction This paper discusses child protection in the United States. I will discuss four general topics. The first topic is United States laws on the protection of children from child abuse and neglect. The second topic is providing care for children who must be removed from their homes. The third is the role of courts in child protection in the United States. 展开更多
关键词 PRO united States Law on the Protection of Abused and Neglected Children
下载PDF
Designing a Protection Scheme in Micro-Grid Systems with DG Using Central Protection Unite and Multiple Setting Group Protection Relays
2
作者 Mostafa I. Saleh Gaber El-Saady +1 位作者 Ali M. Yousef El-Noby A. Ibrahim 《Journal of Power and Energy Engineering》 2024年第9期37-49,共13页
Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this... Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains. 展开更多
关键词 Directional Overcurrent Relay Protection Coordination Distributed Generators Central Protection unite Multiple Setting Group Protection Relay
下载PDF
Networked Protection Scheme with Feeding Section as a Unit for High-speed Railway Traction Power Supply System 被引量:1
3
作者 Zhengqing Han Rui Shen +1 位作者 Shuping Liu Shibin Gao 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1935-1941,共7页
In order to rapidly clear a fault in all-parallel autotransformer(AT)railway system,the existing protection scheme trips both faulted line and healthy line.To solve this problem,a novel unit protection scheme is propo... In order to rapidly clear a fault in all-parallel autotransformer(AT)railway system,the existing protection scheme trips both faulted line and healthy line.To solve this problem,a novel unit protection scheme is proposed in this paper.From fault characteristics measured at substation(SS),AT station(ATS)and section post(SP),we can observe that SS protective relays can detect all the faults but could not be selective,and ATS or SP relays can discriminate the faulted line but not sensitively enough;therefore,we make full use of the fault characteristics and propose a novel unit protection scheme.We employ directional distance protections at SS,ATS and SP,and unify them with networked inter-tripping signals and interlocking signals.When a forward distance protection detects a fault and does not receive inter-locking signals from reverse distance protections of other relays in a short setting time,it will trip the relevant circuit breaker and send an inter-tripping signal to other relays in the same protection unit.Field test results show the proposed scheme trips only the faulted line rapidly and never interrupts the power supply of healthy lines;therefore,the proposed protection scheme obtains both selectivity and speed. 展开更多
关键词 All-parallel AT railway system distance protection unit protection
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部