Hierarchical protection control system of smart substations 被引量:4
1
作者 Yuping ZHENG Delin WANG +1 位作者 Zexin ZHOU Tuanjie CAO 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第3期282-288,共7页
This paper analyzes the problems of the relay protections and secondary circuits of traditional substations,and introduces the hierarchical protection and control system of smart substations based on the technologies ... This paper analyzes the problems of the relay protections and secondary circuits of traditional substations,and introduces the hierarchical protection and control system of smart substations based on the technologies like IEC 61850 Standard,electronic instrument transformer,process level network,and wide area optical fiber communication network,etc.The hierarchical protection and control system includes three levels:local area protection,substation area protection and control,and wide area protection and control.These three levels are combined to solve the problems of the relay protections in traditional substations,thus improving protection performance and control capability of the system. 展开更多
关键词 Smart substation Relay protection Hierarchical protection and control system Local area protection Substation area protection and control Wide area protection and control
原文传递
Study on DeviceNet communication mechanism and its application in protection measurement and control system 被引量:1
2
作者 佟为明 Li Zhongwei +1 位作者 Sun Fanjin Cheng Shukang 《High Technology Letters》 EI CAS 2007年第1期1-5,共5页
To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is ... To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is designed. The communication mechanism of DeviceNet is studied and data trigger modes, communication connection, message types and other key technologies are analyzed. The object modeling and device description of the device are realized too. Results of network test, dynamic simulation and test in the field indicate that this system can accomplish all the communication tasks in real time and can make precise response to every kind of faults of the motor, transformer, line and capacitor. Moreover, this system has higher measurement precision and better control capability. 展开更多
关键词 communication mechanism protection measurement and control system FIELDBUS DEVICENET
下载PDF
AREVA Control Room Accident Filtration System CRAFT
3
作者 Jens Beck Axel Hill Marina Welker 《Journal of Energy and Power Engineering》 2016年第11期692-696,共5页
The AREVA CRAFT (control room accident filtration system) is a solution that maintains the proper air conditions in the main control room and emergency control facilities by filtering the air and removing noble gase... The AREVA CRAFT (control room accident filtration system) is a solution that maintains the proper air conditions in the main control room and emergency control facilities by filtering the air and removing noble gases in case of a severe accident in a nuclear power plant with increased activity concentration in the plant environment. 展开更多
关键词 CRAFT severe accident mitigation control room protection.
下载PDF
IMPROVED FOURIER ALGORITHM FOR CORRECTING POWER SYSTEM FREQUENCY DEVIATION 被引量:1
4
作者 姜惠兰 杨维 +2 位作者 徐建强 刘梅 仇晓锋 《Transactions of Tianjin University》 EI CAS 2001年第3期192-196,共5页
On the basis of high precision requirement for input signals in the power system protection and control system,this paper,only for the influence of power system frequency deviation on extracting fundamental harmonic,s... On the basis of high precision requirement for input signals in the power system protection and control system,this paper,only for the influence of power system frequency deviation on extracting fundamental harmonic,studies the amplitude error of Fourier algorithm,presents a method of correcting frequency deviation,and further derives the formulas of improved Fourier algorithm.The simulation results verified the effectiveness of the algorithm,it not only can greatly weaken the influence of frequency deviation,but also increase the precision of the power system protection and control.As a result the study in this paper has practical application value. 展开更多
关键词 power system protection and control frequency deviation Fourier algorithm
下载PDF
Process Design of Cryogenic Distribution System for CFETR CS Model Coil 被引量:1
5
作者 成安义 张启勇 +1 位作者 付豹 陆小飞 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期202-205,共4页
The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a l... The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented. 展开更多
关键词 CFETR CS distribution system SHe circulation pump quench protection control system
下载PDF
Histone demethylase JMJD3 downregulation protects against aberrant force-induced osteoarthritis through epigenetic control of NR4A1 被引量:2
6
作者 Yu Jin Zhen Liu +5 位作者 Zhenxia Li Hairui Li Cheng Zhu Ruomei Li Ting Zhou Bing Fang 《International Journal of Oral Science》 SCIE CAS CSCD 2022年第3期396-409,共14页
Osteoarthritis(OA)is a prevalent joint disease with no effective treatment strategies.Aberrant mechanical stimuli was demonstrated to be an essential factor for OA pathogenesis.Although multiple studies have detected ... Osteoarthritis(OA)is a prevalent joint disease with no effective treatment strategies.Aberrant mechanical stimuli was demonstrated to be an essential factor for OA pathogenesis.Although multiple studies have detected potential regulatory mechanisms underlying OA and have concentrated on developing novel treatment strategies,the epigenetic control of OA remains unclear.Histone demethylase JMJD3 has been reported to mediate multiple physiological and pathological processes,including cell differentiation,proliferation,autophagy,and apoptosis.However,the regulation of JMJD3 in aberrant force-related OA and its mediatory effect on disease progression are still unknown.In this work,we confirmed the upregulation of JMJD3 in aberrant forceinduced cartilage injury in vitro and in vivo.Functionally,inhibition of JMJD3 by its inhibitor,GSK-J4,or downregulation of JMJD3 by adenovirus infection of sh-JMJD3 could alleviate the aberrant force-induced chondrocyte injury.Mechanistic investigation illustrated that aberrant force induces JMJD3 expression and then demethylates H3K27me3 at the NR4A1 promoter to promote its expression.Further experiments indicated that NR4A1 can regulate chondrocyte apoptosis,cartilage degeneration,extracellular matrix degradation,and inflammatory responses.In vivo,anterior cruciate ligament transection(ACLT)was performed to construct an OA model,and the therapeutic effect of GSK-J4 was validated.More importantly,we adopted a peptide-si RNA nanoplatform to deliver si-JMJD3 into articular cartilage,and the severity of joint degeneration was remarkably mitigated.Taken together,our findings demonstrated that JMJD3 is flow-responsive and epigenetically regulates OA progression.Our work provides evidences for JMJD3 inhibition as an innovative epigenetic therapy approach for joint diseases by utilizing p5RHH-si RNA nanocomplexes. 展开更多
关键词 Histone demethylase JMJD3 downregulation protects against aberrant force-induced osteoarthritis through epigenetic control of NR4A1
下载PDF
Fuzzy Controller Used to Protect Collision
7
《Rare Metals》 SCIE EI CAS CSCD 1993年第1期73-73,共1页
A FC-1B type fuzzy controller used to protect collision in automobile running has heen devel-oped by Computer Institute, North Technological University. This facility has been authenticatedby specialists. This is a sc... A FC-1B type fuzzy controller used to protect collision in automobile running has heen devel-oped by Computer Institute, North Technological University. This facility has been authenticatedby specialists. This is a sci-tech fruit which integrates the hardware and software from fuzzy con-trol and artificial intelligence. This technique adopts initiative r-ime ultrasonic range-findingprobe, rapid fuzzy control algorithm, fuzzy discern and fuzzy decision etc. This technique is adapt- 展开更多
关键词 Fuzzy controller Used to Protect Collision FC
下载PDF
Control and protection strategy for MMC MTDC system under converter-side AC fault during converter blocking failure 被引量:34
8
作者 Puyu WANG Xiao-Ping ZHANG +1 位作者 Paul F.COVENTRY Zhou LI 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第3期272-281,共10页
This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operatin... This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results. 展开更多
关键词 Converter blocking failure Converter-side AC fault control and protection Modular multilevel converter(MMC) Multi-terminal high-voltage direct current(MTDC) Real-time digital simulation
原文传递
Developments of power system protection and control 被引量:27
9
作者 Z.Q.Bo X.N.Lin +2 位作者 Q.P.Wang Y.H.Yi F.Q.Zhou 《Protection and Control of Modern Power Systems》 2016年第1期1-8,共8页
Synchronized wide area communication has become a mature technology,which makes the real-time interaction between the substations and the wide area protection and control system possible.However,the present protection... Synchronized wide area communication has become a mature technology,which makes the real-time interaction between the substations and the wide area protection and control system possible.However,the present protection and control system to handle this real-time data has been recognized to be deficient.This paper begins by reviewing the development history of power system protection,with special attention paid to the recent development in the field of wide-area and integrated protections,in order to look into the future development of protection and control systems.Then the concept of integrated wide area protection and control is introduced,where it can be shown that a hierarchical protection and control system provides the protection and control for wide area or regional power substations/plants and their associated power networks.The system is mainly divided into three levels:the local,the substation/plant,and the wide area/regional.The integrated functions at each level are described in details with an aim to develop an optimal coordination mechanism between each level.The key element in the proposed system is the wide area real-time protection and control information platform,which not only enables the merger of three lines of defence for power system protection and control,but also provides a perfect tool for the application of cloud computing in substations and power networks. 展开更多
关键词 Power system protection Wide area protection Integrated protection and control Information platform
原文传递
A novel model-based multivariable framework for aircraft gas turbine engine limit protection control 被引量:2
10
作者 Shuwei PANG Soheil JAFARI +1 位作者 Theoklis NIKOLAIDIS Qiuhong LI 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2021年第12期57-72,共16页
Control technologies are innovated to satisfy increasingly complicated control demands of gas turbine engines.In terms of limit protection control,a novel model-based multivariable limit protection control method,whic... Control technologies are innovated to satisfy increasingly complicated control demands of gas turbine engines.In terms of limit protection control,a novel model-based multivariable limit protection control method,which is achieved by adaptive command reconstruction and multiplecontrol loop selection and switch logic,is proposed in this paper to address the problem of balancing smaller thrust loss and safe operations by comparing with widely-used Min-Max logic.Five different combination modes of control loops,which represent the online control loop of last time instant and that of current time instant,is analyzed.Different command reconstructions are designed for these modes,which is based on static gain conversion of amplitude beyond limits by using an onboard model.The double-prediction based control loop selection and switch logic is developed to choose a control loop appropriately by comparing converted amplitude beyond limits regardless of one or more parameters tending to exceed limits.The proposed method is implemented in a twin-spool turbofan engine to achieve limit protection with direct thrust control,and the loss of thrust is improved by about 30% in comparison with the loss of thrust caused by Min-Max logic when limit protection control is activated,which demonstrates the effectiveness of the proposed method. 展开更多
关键词 Amplitude conversion Command reconstruction Gas turbine engine Limit protection control Multivariable control Onboard prediction
原文传递
An Intelligent Coordinated Protection and Control Strategy for Distribution Network with Wind Generation Integration 被引量:5
11
作者 Zhou Liu Hans Kr.Høidalen Murari Mohan Saha 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第4期23-30,共8页
Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration ... Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration and upgrade the protection system performance,an intelligent coordinated protection and control strategy is proposed.A cost based optimization method is adopted to minimize the operation costs of possible solutions.Its aim is to define the optimal relay settings for the present operation condition,and the most suitable control mode of converter based wind turbine DG.Case studies on a hardware in the loop real time simulation platform demonstrate the proposed protection strategy. 展开更多
关键词 Converter based wind turbine DG coordinated protection and control hardware in the loop real time simulation
原文传递
Guest editorial: special issue on wide area monitoring, protection and control in smart grid 被引量:1
12
作者 Vladimir TERZIJA Yutian LIU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第3期317-318,共2页
Complexity of modern electrical power systems is steadily increasing.This is inspiring researchers and developers to propose new solutions capable to address a number of challenges,particularly those related to power ... Complexity of modern electrical power systems is steadily increasing.This is inspiring researchers and developers to propose new solutions capable to address a number of challenges,particularly those related to power system operation.A massive penetration of asynchronously connected renewable energy generation,the generation connected over inverters,is significantly changing the dynamics of modern power systems.From one hand,the power system response time is becoming shorter and at the same time the fault level is becoming smaller.This is significantly affecting requirements of control loops,as well as power system protection. 展开更多
关键词 Guest editorial protection and control in smart grid special issue on wide area monitoring
原文传递
MCHOKeM algorithm with assured bandwidth allocation in DiffServ networks
13
作者 Haifeng Du Yang Xiao Kiseon Kim 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2010年第4期531-536,共6页
An active queue management(AQM) algorithm called MCHOKeM is presented,which is borrowed from CHOKeW that draws multi-packets at random from the buffer,the multi-packets are compared with an arriving packet and aband... An active queue management(AQM) algorithm called MCHOKeM is presented,which is borrowed from CHOKeW that draws multi-packets at random from the buffer,the multi-packets are compared with an arriving packet and abandoned if they are from the same flow.But MCHOKeM uses multiple virtual queues for different priority packets and enhances the drawing function by adjusting the maximum number of draws based on the current status of virtual queue length.The number of parameters that MCHOKeM needs to maintain is determined by the number of priority levels being supported by the router,which usually has a small limited value.In order to explain the features of MCHOKeM,an analytical model is used.A series of simulation tests to evaluate the performance are given. 展开更多
关键词 congestion control theory differentiated services(DiffServ) transaction control protocol(TCP) protection fairness analysis.
下载PDF
Reflections on stability technology for reducing risk of system collapse due to cascading outages 被引量:18
14
作者 Yongjie FANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2014年第3期264-271,共8页
This paper aims at putting forward viewpoints regarding the use of stability technology to prevent and control cascading outages by examining recent blackout events.Based on the inquiry reports of the 2011 SouthwestAm... This paper aims at putting forward viewpoints regarding the use of stability technology to prevent and control cascading outages by examining recent blackout events.Based on the inquiry reports of the 2011 SouthwestAmerica blackout and the 2012 India power blackouts,event evolution features are first summarized from a stability perspective.Then a comparative analysis is conducted so as to propose suggestions of effective measures,either preventive or emergency,which could have avoided the blackouts.It is shown that applications of several mature technologies can create opportunities of preventing or interrupting the cascading development.These include offline dynamic simulation,online stability analysis and preventive control,real-time situational awareness and automatic emergency control.Further R&D directions are given to address the challenges of modern power systems as well.They cover system fault identification criterion of protection and control devices,verification of adaptability of control effect to system operating conditions,real-time operational management of emergency control measures and improvement of simulation accuracy. 展开更多
关键词 Cascading outages BLACKOUT system collapse Stability technology protection and control
原文传递
Recent advances on smart grid technology and renewable energy integration 被引量:9
15
作者 MEI ShengWei CHEN LaiJun 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第12期3040-3048,共9页
With the integration of renewable energy generations and other related changes,the smart grid,or the future electric power system,is confronted with new challenges and opportunities.Therefore,it is a promising subject... With the integration of renewable energy generations and other related changes,the smart grid,or the future electric power system,is confronted with new challenges and opportunities.Therefore,it is a promising subject in electrical engineering and much work has been done on it.This paper reviews the recent advances on the technologies of smart grid and renewable energy integration,from the aspects of modeling,simulation,protection and control,stability,operation,and planning. 展开更多
关键词 smart grid renewable energy integration MODELING SIMULATION protection and control STABILITY operation PLANNING
原文传递
Smart Power Substation Development in China 被引量:1
16
作者 Xinzhou Dong Delin Wang +3 位作者 Manyong Zhao Bin Wang Shenxing Shi Alexander Apostolov 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第4期1-5,共5页
Over the past decade,China has undertaken substation intellectualization of more than 2000 substation operations in three stages.Much experience has been achieved during this developmental period.In this paper,the sta... Over the past decade,China has undertaken substation intellectualization of more than 2000 substation operations in three stages.Much experience has been achieved during this developmental period.In this paper,the status of smart substation development in China is systematically presented,as well as future directions of the smart substation,such as adoption of the hierarchical protection and control system. 展开更多
关键词 Backup protection optimization data sharing IEC61850 protection and control integration smart power substation wide area protection