To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is ...To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is designed. The communication mechanism of DeviceNet is studied and data trigger modes, communication connection, message types and other key technologies are analyzed. The object modeling and device description of the device are realized too. Results of network test, dynamic simulation and test in the field indicate that this system can accomplish all the communication tasks in real time and can make precise response to every kind of faults of the motor, transformer, line and capacitor. Moreover, this system has higher measurement precision and better control capability.展开更多
A FC-1B type fuzzy controller used to protect collision in automobile running has heen devel-oped by Computer Institute, North Technological University. This facility has been authenticatedby specialists. This is a sc...A FC-1B type fuzzy controller used to protect collision in automobile running has heen devel-oped by Computer Institute, North Technological University. This facility has been authenticatedby specialists. This is a sci-tech fruit which integrates the hardware and software from fuzzy con-trol and artificial intelligence. This technique adopts initiative r-ime ultrasonic range-findingprobe, rapid fuzzy control algorithm, fuzzy discern and fuzzy decision etc. This technique is adapt-展开更多
On the basis of high precision requirement for input signals in the power system protection and control system,this paper,only for the influence of power system frequency deviation on extracting fundamental harmonic,s...On the basis of high precision requirement for input signals in the power system protection and control system,this paper,only for the influence of power system frequency deviation on extracting fundamental harmonic,studies the amplitude error of Fourier algorithm,presents a method of correcting frequency deviation,and further derives the formulas of improved Fourier algorithm.The simulation results verified the effectiveness of the algorithm,it not only can greatly weaken the influence of frequency deviation,but also increase the precision of the power system protection and control.As a result the study in this paper has practical application value.展开更多
The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a l...The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.展开更多
Osteoarthritis(OA)is a prevalent joint disease with no effective treatment strategies.Aberrant mechanical stimuli was demonstrated to be an essential factor for OA pathogenesis.Although multiple studies have detected ...Osteoarthritis(OA)is a prevalent joint disease with no effective treatment strategies.Aberrant mechanical stimuli was demonstrated to be an essential factor for OA pathogenesis.Although multiple studies have detected potential regulatory mechanisms underlying OA and have concentrated on developing novel treatment strategies,the epigenetic control of OA remains unclear.Histone demethylase JMJD3 has been reported to mediate multiple physiological and pathological processes,including cell differentiation,proliferation,autophagy,and apoptosis.However,the regulation of JMJD3 in aberrant force-related OA and its mediatory effect on disease progression are still unknown.In this work,we confirmed the upregulation of JMJD3 in aberrant forceinduced cartilage injury in vitro and in vivo.Functionally,inhibition of JMJD3 by its inhibitor,GSK-J4,or downregulation of JMJD3 by adenovirus infection of sh-JMJD3 could alleviate the aberrant force-induced chondrocyte injury.Mechanistic investigation illustrated that aberrant force induces JMJD3 expression and then demethylates H3K27me3 at the NR4A1 promoter to promote its expression.Further experiments indicated that NR4A1 can regulate chondrocyte apoptosis,cartilage degeneration,extracellular matrix degradation,and inflammatory responses.In vivo,anterior cruciate ligament transection(ACLT)was performed to construct an OA model,and the therapeutic effect of GSK-J4 was validated.More importantly,we adopted a peptide-si RNA nanoplatform to deliver si-JMJD3 into articular cartilage,and the severity of joint degeneration was remarkably mitigated.Taken together,our findings demonstrated that JMJD3 is flow-responsive and epigenetically regulates OA progression.Our work provides evidences for JMJD3 inhibition as an innovative epigenetic therapy approach for joint diseases by utilizing p5RHH-si RNA nanocomplexes.展开更多
An active queue management(AQM) algorithm called MCHOKeM is presented,which is borrowed from CHOKeW that draws multi-packets at random from the buffer,the multi-packets are compared with an arriving packet and aband...An active queue management(AQM) algorithm called MCHOKeM is presented,which is borrowed from CHOKeW that draws multi-packets at random from the buffer,the multi-packets are compared with an arriving packet and abandoned if they are from the same flow.But MCHOKeM uses multiple virtual queues for different priority packets and enhances the drawing function by adjusting the maximum number of draws based on the current status of virtual queue length.The number of parameters that MCHOKeM needs to maintain is determined by the number of priority levels being supported by the router,which usually has a small limited value.In order to explain the features of MCHOKeM,an analytical model is used.A series of simulation tests to evaluate the performance are given.展开更多
The AREVA CRAFT (control room accident filtration system) is a solution that maintains the proper air conditions in the main control room and emergency control facilities by filtering the air and removing noble gase...The AREVA CRAFT (control room accident filtration system) is a solution that maintains the proper air conditions in the main control room and emergency control facilities by filtering the air and removing noble gases in case of a severe accident in a nuclear power plant with increased activity concentration in the plant environment.展开更多
This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operatin...This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.展开更多
This paper analyzes the problems of the relay protections and secondary circuits of traditional substations,and introduces the hierarchical protection and control system of smart substations based on the technologies ...This paper analyzes the problems of the relay protections and secondary circuits of traditional substations,and introduces the hierarchical protection and control system of smart substations based on the technologies like IEC 61850 Standard,electronic instrument transformer,process level network,and wide area optical fiber communication network,etc.The hierarchical protection and control system includes three levels:local area protection,substation area protection and control,and wide area protection and control.These three levels are combined to solve the problems of the relay protections in traditional substations,thus improving protection performance and control capability of the system.展开更多
Synchronized wide area communication has become a mature technology,which makes the real-time interaction between the substations and the wide area protection and control system possible.However,the present protection...Synchronized wide area communication has become a mature technology,which makes the real-time interaction between the substations and the wide area protection and control system possible.However,the present protection and control system to handle this real-time data has been recognized to be deficient.This paper begins by reviewing the development history of power system protection,with special attention paid to the recent development in the field of wide-area and integrated protections,in order to look into the future development of protection and control systems.Then the concept of integrated wide area protection and control is introduced,where it can be shown that a hierarchical protection and control system provides the protection and control for wide area or regional power substations/plants and their associated power networks.The system is mainly divided into three levels:the local,the substation/plant,and the wide area/regional.The integrated functions at each level are described in details with an aim to develop an optimal coordination mechanism between each level.The key element in the proposed system is the wide area real-time protection and control information platform,which not only enables the merger of three lines of defence for power system protection and control,but also provides a perfect tool for the application of cloud computing in substations and power networks.展开更多
Control technologies are innovated to satisfy increasingly complicated control demands of gas turbine engines.In terms of limit protection control,a novel model-based multivariable limit protection control method,whic...Control technologies are innovated to satisfy increasingly complicated control demands of gas turbine engines.In terms of limit protection control,a novel model-based multivariable limit protection control method,which is achieved by adaptive command reconstruction and multiplecontrol loop selection and switch logic,is proposed in this paper to address the problem of balancing smaller thrust loss and safe operations by comparing with widely-used Min-Max logic.Five different combination modes of control loops,which represent the online control loop of last time instant and that of current time instant,is analyzed.Different command reconstructions are designed for these modes,which is based on static gain conversion of amplitude beyond limits by using an onboard model.The double-prediction based control loop selection and switch logic is developed to choose a control loop appropriately by comparing converted amplitude beyond limits regardless of one or more parameters tending to exceed limits.The proposed method is implemented in a twin-spool turbofan engine to achieve limit protection with direct thrust control,and the loss of thrust is improved by about 30% in comparison with the loss of thrust caused by Min-Max logic when limit protection control is activated,which demonstrates the effectiveness of the proposed method.展开更多
Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration ...Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration and upgrade the protection system performance,an intelligent coordinated protection and control strategy is proposed.A cost based optimization method is adopted to minimize the operation costs of possible solutions.Its aim is to define the optimal relay settings for the present operation condition,and the most suitable control mode of converter based wind turbine DG.Case studies on a hardware in the loop real time simulation platform demonstrate the proposed protection strategy.展开更多
Complexity of modern electrical power systems is steadily increasing.This is inspiring researchers and developers to propose new solutions capable to address a number of challenges,particularly those related to power ...Complexity of modern electrical power systems is steadily increasing.This is inspiring researchers and developers to propose new solutions capable to address a number of challenges,particularly those related to power system operation.A massive penetration of asynchronously connected renewable energy generation,the generation connected over inverters,is significantly changing the dynamics of modern power systems.From one hand,the power system response time is becoming shorter and at the same time the fault level is becoming smaller.This is significantly affecting requirements of control loops,as well as power system protection.展开更多
This paper aims at putting forward viewpoints regarding the use of stability technology to prevent and control cascading outages by examining recent blackout events.Based on the inquiry reports of the 2011 SouthwestAm...This paper aims at putting forward viewpoints regarding the use of stability technology to prevent and control cascading outages by examining recent blackout events.Based on the inquiry reports of the 2011 SouthwestAmerica blackout and the 2012 India power blackouts,event evolution features are first summarized from a stability perspective.Then a comparative analysis is conducted so as to propose suggestions of effective measures,either preventive or emergency,which could have avoided the blackouts.It is shown that applications of several mature technologies can create opportunities of preventing or interrupting the cascading development.These include offline dynamic simulation,online stability analysis and preventive control,real-time situational awareness and automatic emergency control.Further R&D directions are given to address the challenges of modern power systems as well.They cover system fault identification criterion of protection and control devices,verification of adaptability of control effect to system operating conditions,real-time operational management of emergency control measures and improvement of simulation accuracy.展开更多
With the integration of renewable energy generations and other related changes,the smart grid,or the future electric power system,is confronted with new challenges and opportunities.Therefore,it is a promising subject...With the integration of renewable energy generations and other related changes,the smart grid,or the future electric power system,is confronted with new challenges and opportunities.Therefore,it is a promising subject in electrical engineering and much work has been done on it.This paper reviews the recent advances on the technologies of smart grid and renewable energy integration,from the aspects of modeling,simulation,protection and control,stability,operation,and planning.展开更多
Over the past decade,China has undertaken substation intellectualization of more than 2000 substation operations in three stages.Much experience has been achieved during this developmental period.In this paper,the sta...Over the past decade,China has undertaken substation intellectualization of more than 2000 substation operations in three stages.Much experience has been achieved during this developmental period.In this paper,the status of smart substation development in China is systematically presented,as well as future directions of the smart substation,such as adoption of the hierarchical protection and control system.展开更多
文摘To fit in with the developing requirement of int and communication of protective relays, a protection egrated functions of protection measurement, control measurement and control system based on DeviceNet fieldbus is designed. The communication mechanism of DeviceNet is studied and data trigger modes, communication connection, message types and other key technologies are analyzed. The object modeling and device description of the device are realized too. Results of network test, dynamic simulation and test in the field indicate that this system can accomplish all the communication tasks in real time and can make precise response to every kind of faults of the motor, transformer, line and capacitor. Moreover, this system has higher measurement precision and better control capability.
文摘A FC-1B type fuzzy controller used to protect collision in automobile running has heen devel-oped by Computer Institute, North Technological University. This facility has been authenticatedby specialists. This is a sci-tech fruit which integrates the hardware and software from fuzzy con-trol and artificial intelligence. This technique adopts initiative r-ime ultrasonic range-findingprobe, rapid fuzzy control algorithm, fuzzy discern and fuzzy decision etc. This technique is adapt-
文摘On the basis of high precision requirement for input signals in the power system protection and control system,this paper,only for the influence of power system frequency deviation on extracting fundamental harmonic,studies the amplitude error of Fourier algorithm,presents a method of correcting frequency deviation,and further derives the formulas of improved Fourier algorithm.The simulation results verified the effectiveness of the algorithm,it not only can greatly weaken the influence of frequency deviation,but also increase the precision of the power system protection and control.As a result the study in this paper has practical application value.
文摘The superconducting magnet of Central Solenoid(CS) model coil of China Fusion Engineering Test Reactor(CFETR) is made of Nb_3Sn/Nb Ti cable-in-conduit conductor(CICC),and operated by forced-flow cooling with a large amount of supercritical helium.The cryogenic circulation pump is analyzed and considered to be effective in achieving the supercritical helium(SHe) circulation for the forced-flow cooled(FFC) CICC magnet.A distributed system will be constructed for cooling the CFETR CS model coil.This paper presents the design of FFC process for the CFETR CS model coil.The equipment configuration,quench protection in the magnet and the process control are presented.
基金supported by National Natural Science Foundation of China(11932012,81870790 and 31801233)Science and Technology Commission of Shanghai Municipality(18441903600)+1 种基金Clinical Research Plan of SHDC(No.SHDC2020CR3009A)Innovative Research Team of High-level Local Universities in Shanghai(SSMU-ZDCX20180902)。
文摘Osteoarthritis(OA)is a prevalent joint disease with no effective treatment strategies.Aberrant mechanical stimuli was demonstrated to be an essential factor for OA pathogenesis.Although multiple studies have detected potential regulatory mechanisms underlying OA and have concentrated on developing novel treatment strategies,the epigenetic control of OA remains unclear.Histone demethylase JMJD3 has been reported to mediate multiple physiological and pathological processes,including cell differentiation,proliferation,autophagy,and apoptosis.However,the regulation of JMJD3 in aberrant force-related OA and its mediatory effect on disease progression are still unknown.In this work,we confirmed the upregulation of JMJD3 in aberrant forceinduced cartilage injury in vitro and in vivo.Functionally,inhibition of JMJD3 by its inhibitor,GSK-J4,or downregulation of JMJD3 by adenovirus infection of sh-JMJD3 could alleviate the aberrant force-induced chondrocyte injury.Mechanistic investigation illustrated that aberrant force induces JMJD3 expression and then demethylates H3K27me3 at the NR4A1 promoter to promote its expression.Further experiments indicated that NR4A1 can regulate chondrocyte apoptosis,cartilage degeneration,extracellular matrix degradation,and inflammatory responses.In vivo,anterior cruciate ligament transection(ACLT)was performed to construct an OA model,and the therapeutic effect of GSK-J4 was validated.More importantly,we adopted a peptide-si RNA nanoplatform to deliver si-JMJD3 into articular cartilage,and the severity of joint degeneration was remarkably mitigated.Taken together,our findings demonstrated that JMJD3 is flow-responsive and epigenetically regulates OA progression.Our work provides evidences for JMJD3 inhibition as an innovative epigenetic therapy approach for joint diseases by utilizing p5RHH-si RNA nanocomplexes.
基金supported by the Beijing Natural Science Foundation(4102050)USFC-KOSEF Joint Research Project of China and Korea(60811140343)
文摘An active queue management(AQM) algorithm called MCHOKeM is presented,which is borrowed from CHOKeW that draws multi-packets at random from the buffer,the multi-packets are compared with an arriving packet and abandoned if they are from the same flow.But MCHOKeM uses multiple virtual queues for different priority packets and enhances the drawing function by adjusting the maximum number of draws based on the current status of virtual queue length.The number of parameters that MCHOKeM needs to maintain is determined by the number of priority levels being supported by the router,which usually has a small limited value.In order to explain the features of MCHOKeM,an analytical model is used.A series of simulation tests to evaluate the performance are given.
文摘The AREVA CRAFT (control room accident filtration system) is a solution that maintains the proper air conditions in the main control room and emergency control facilities by filtering the air and removing noble gases in case of a severe accident in a nuclear power plant with increased activity concentration in the plant environment.
基金This work is supported by UK EPSRC and UK National Grid.
文摘This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.
文摘This paper analyzes the problems of the relay protections and secondary circuits of traditional substations,and introduces the hierarchical protection and control system of smart substations based on the technologies like IEC 61850 Standard,electronic instrument transformer,process level network,and wide area optical fiber communication network,etc.The hierarchical protection and control system includes three levels:local area protection,substation area protection and control,and wide area protection and control.These three levels are combined to solve the problems of the relay protections in traditional substations,thus improving protection performance and control capability of the system.
文摘Synchronized wide area communication has become a mature technology,which makes the real-time interaction between the substations and the wide area protection and control system possible.However,the present protection and control system to handle this real-time data has been recognized to be deficient.This paper begins by reviewing the development history of power system protection,with special attention paid to the recent development in the field of wide-area and integrated protections,in order to look into the future development of protection and control systems.Then the concept of integrated wide area protection and control is introduced,where it can be shown that a hierarchical protection and control system provides the protection and control for wide area or regional power substations/plants and their associated power networks.The system is mainly divided into three levels:the local,the substation/plant,and the wide area/regional.The integrated functions at each level are described in details with an aim to develop an optimal coordination mechanism between each level.The key element in the proposed system is the wide area real-time protection and control information platform,which not only enables the merger of three lines of defence for power system protection and control,but also provides a perfect tool for the application of cloud computing in substations and power networks.
基金supported by China Scholarship Council(No.201906830081)。
文摘Control technologies are innovated to satisfy increasingly complicated control demands of gas turbine engines.In terms of limit protection control,a novel model-based multivariable limit protection control method,which is achieved by adaptive command reconstruction and multiplecontrol loop selection and switch logic,is proposed in this paper to address the problem of balancing smaller thrust loss and safe operations by comparing with widely-used Min-Max logic.Five different combination modes of control loops,which represent the online control loop of last time instant and that of current time instant,is analyzed.Different command reconstructions are designed for these modes,which is based on static gain conversion of amplitude beyond limits by using an onboard model.The double-prediction based control loop selection and switch logic is developed to choose a control loop appropriately by comparing converted amplitude beyond limits regardless of one or more parameters tending to exceed limits.The proposed method is implemented in a twin-spool turbofan engine to achieve limit protection with direct thrust control,and the loss of thrust is improved by about 30% in comparison with the loss of thrust caused by Min-Max logic when limit protection control is activated,which demonstrates the effectiveness of the proposed method.
基金supported by Norwegian University of Science and Technology.
文摘Integration of distributed generation(DG)can change the fault current level and direction in the distribution system,which affects the related protection system.In order to limit the negative impact of DG integration and upgrade the protection system performance,an intelligent coordinated protection and control strategy is proposed.A cost based optimization method is adopted to minimize the operation costs of possible solutions.Its aim is to define the optimal relay settings for the present operation condition,and the most suitable control mode of converter based wind turbine DG.Case studies on a hardware in the loop real time simulation platform demonstrate the proposed protection strategy.
文摘Complexity of modern electrical power systems is steadily increasing.This is inspiring researchers and developers to propose new solutions capable to address a number of challenges,particularly those related to power system operation.A massive penetration of asynchronously connected renewable energy generation,the generation connected over inverters,is significantly changing the dynamics of modern power systems.From one hand,the power system response time is becoming shorter and at the same time the fault level is becoming smaller.This is significantly affecting requirements of control loops,as well as power system protection.
基金This work is supported by State Grid Corporation of China(No.SGCC-MPLG003-2012).
文摘This paper aims at putting forward viewpoints regarding the use of stability technology to prevent and control cascading outages by examining recent blackout events.Based on the inquiry reports of the 2011 SouthwestAmerica blackout and the 2012 India power blackouts,event evolution features are first summarized from a stability perspective.Then a comparative analysis is conducted so as to propose suggestions of effective measures,either preventive or emergency,which could have avoided the blackouts.It is shown that applications of several mature technologies can create opportunities of preventing or interrupting the cascading development.These include offline dynamic simulation,online stability analysis and preventive control,real-time situational awareness and automatic emergency control.Further R&D directions are given to address the challenges of modern power systems as well.They cover system fault identification criterion of protection and control devices,verification of adaptability of control effect to system operating conditions,real-time operational management of emergency control measures and improvement of simulation accuracy.
基金supported by the National Natural Science Foundation of China(Grant Nos.51321005,51207076)the National High Technology Research and Development of China("863" Project)(Grant No.2012AA050204)
文摘With the integration of renewable energy generations and other related changes,the smart grid,or the future electric power system,is confronted with new challenges and opportunities.Therefore,it is a promising subject in electrical engineering and much work has been done on it.This paper reviews the recent advances on the technologies of smart grid and renewable energy integration,from the aspects of modeling,simulation,protection and control,stability,operation,and planning.
基金National Natural Science Foundation of China under Grant 51120175001Key Project of Smart Grid Technology and Equipment of National Key Research and Development Plan of China under Grant 2016YFB0900600Science and Technology Project of State Grid Corporation of China under Grant GWKJ2013-005.
文摘Over the past decade,China has undertaken substation intellectualization of more than 2000 substation operations in three stages.Much experience has been achieved during this developmental period.In this paper,the status of smart substation development in China is systematically presented,as well as future directions of the smart substation,such as adoption of the hierarchical protection and control system.