期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Setting up Foundling Islands and the Protection of Children Rights
1
作者 LIU HUAWEN 《The Journal of Human Rights》 2014年第5期24-28,共5页
Foundling islands are also called baby safety islands. Overseas they are also called foundling protection cabins and are a place to care for abandoned babies. In June 2011, the Shijiazhuang Social Welfare Institute in... Foundling islands are also called baby safety islands. Overseas they are also called foundling protection cabins and are a place to care for abandoned babies. In June 2011, the Shijiazhuang Social Welfare Institute in Hebei Province set up a foundling island. By the end of 2013, many cities had set up such islands, which is a new measure for ensuring children rights. 展开更多
关键词 setting up Foundling Islands and the protection of Children Rights
下载PDF
A Novel Single Phase Grounding Fault Protection Scheme Without Threshold Setting for Neutral Ineffectively Earthed Power Systems 被引量:9
2
作者 Xiangjun Zeng Kun Yu +1 位作者 Yuanyuan Wang Yao Xu 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第3期73-81,共9页
The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the se... The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the setting value based conventional protection schemes sometimes cannot satisfy the protection requirements of neutral ineffectively earthed power systems(NIEPS)due to wide variations in operating conditions and the complexities of fault cases.In this paper,a novel single phase grounding fault protection scheme without threshold setting is proposed.The fault detection is achieved based on operating states rather than setting values.A fuzzy c-means algorithm is used to divide the operating state of the protected feeder into non-fault states and fault states.The cluster center of each state is then obtained by classifying the historical feature samples of the protected feeder extracted under various operating conditions into their corresponding states in a constructed multi-dimensional fault feature space.The distances between the detected feature samples and the cluster centers of the non-fault and the fault states are calculated.If the distance to the fault state is shorter than that to the non-fault state,a fault is detected.Otherwise,the feeder is considered normal.A PSCAD/EMTDC simulator is used to simulate a 35 kV NIEPS under various operating conditions,non-linear loads,and complex fault cases.Results show that the proposed single phase grounding fault protection scheme without threshold setting can protect the system correctly under all kinds of faults. 展开更多
关键词 Distribution networks FCM algorithm neutral ineffectively earthed power systems protection scheme without threshold setting
原文传递