期刊文献+
共找到3,238篇文章
< 1 2 162 >
每页显示 20 50 100
Formation and ecological response of sand patches in the protection system of Shapotou section of the Baotou-Lanzhou railway,China
1
作者 DUN Yaoquan QU Jianjun +4 位作者 KANG Wenyan LI Minlan LIU Bin WANG Tao SHAO Mei 《Journal of Arid Land》 SCIE CSCD 2024年第2期298-313,共16页
The development of bare patches typically signifies a process of ecosystem degradation.Within the protection system of Shapotou section of the Baotou-Lanzhou railway,the extensive emergence of bare sand patches poses ... The development of bare patches typically signifies a process of ecosystem degradation.Within the protection system of Shapotou section of the Baotou-Lanzhou railway,the extensive emergence of bare sand patches poses a threat to both stability and sustainability.However,there is limited knowledge regarding the morphology,dynamic changes,and ecological responses associated with these sand patches.Therefore,we analyzed the formation and development process of sand patches within the protection system and its effects on herbaceous vegetation growth and soil nutrients through field observation,survey,and indoor analysis methods.The results showed that sand patch development can be divided into three stages,i.e.,formation,expansion,and stabilization,which correspond to the initial,actively developing,and semi-fixed sand patches,respectively.The average dimensions of all sand patch erosional areas were found to be 7.72 m in length,3.91 m in width,and 0.32 m in depth.The actively developing sand patches were the largest,and the initial sand patches were the smallest.Throughout the stage of formation and expansion,the herbaceous community composition changed,and the plant density decreased by more than 50.95%.Moreover,the coverage and height of herbaceous plants decreased in the erosional area and slightly increased in the depositional lobe;and the fine particles and nutrients of soils in the erosional area and depositional lobe showed a decreasing trend.In the stabilization phases of sand patches,the area from the inlet to the bottom of sand patches becomes initially covered with crusts.Vegetation and 0-2 cm surface soil condition improved in the erosional area,but this improvement was not yet evident in the depositional lobe.Factors such as disturbance,climate change,and surface resistance to erosion exert notable influences on the formation and dynamics of sand patches.The results can provide evidence for the future treatment of sand patches and the management of the protection system of Shapotou section of the Baotou-Lanzhou railway. 展开更多
关键词 railway protection system sand patch MORPHOLOGY vegetation characteristic soil property
下载PDF
100 kA/10kV thyristor stack design for the quench protection system in CRAFT
2
作者 仝玮 徐猛 +2 位作者 李华 陈波 宋执权 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第5期193-206,共14页
Thyristors have longer lifetimes,higher reliability,and very high voltage and current ratings and they require less maintenance than other high-power semiconductor devices.As a result,they are particularly suitable fo... Thyristors have longer lifetimes,higher reliability,and very high voltage and current ratings and they require less maintenance than other high-power semiconductor devices.As a result,they are particularly suitable for quench protection systems(QPSs),which protect the superconducting magnets in large fusion devices from damage.In this paper,we propose a design for a 100 k A/10 k V thyristor stack supported by both theoretical and simulation-based analyses as well as experimental verification.Due to the ultrahigh electrical performance requirements imposed on the QPS by the Comprehensive Research Facility for Fusion Technology(CRAFT),three main issues must be considered:the voltage-balancing problem caused by multiple thyristors in a series structure,the increased junction temperature problem caused by extremely high currents,and the reverse recovery phenomenon that arises from the thyristor’s physical structure.Hence,a series of detailed theoretical analyses,simulations,and experiments,including a thyristor junction temperature prediction method and reverse recovery process modeling,were carried out to optimize the design.Finally,the reliability and stability of the thyristor stack were verified by a series of prototype experiments.The results confirmed the correctness and accuracy of the proposed thyristor stack design method and also indicated that the proposed thyristor stack can meet the application conditions of a 100 k A QPS in the CRAFT project. 展开更多
关键词 superconducting magnet THYRISTOR pulsed power supply quench protection system
下载PDF
HIL testing of wheel slide protection systems:criteria for continuous updating and validation
3
作者 L.Pugi G.Paolieri +4 位作者 M.Giorgetti L.Berzi R.Viviani L.Cabrucci L.Bocciolini 《Railway Engineering Science》 2023年第2期108-121,共14页
Assessment of railway wheel slide protection(WSP) systems involves the execution of complex experimental activities that are quite expensive and time-consuming, since they involve the physical reproduction of degraded... Assessment of railway wheel slide protection(WSP) systems involves the execution of complex experimental activities that are quite expensive and time-consuming, since they involve the physical reproduction of degraded adhesion conditions on a real railway line. WSP is devoted to regulating applied braking forces to avoid excessive wheel sliding in case of degraded adhesion conditions between wheel and rail. WSP must be also compliant to safety specifications related to assured braking performances and consumed air. Hardware in the loop(HIL) testing offers an affordable and sustainable way to accelerate these activities optimizing cost, duration and safety of experimental activities performed online. HIL test rigs are subjected to continuous updates, customization and natural ageing of their components. This work investigates the criteria that can be adopted to assure a continuous monitoring and validation of a real WSP test rig, the Italian test rig of Firenze Osmannoro. 展开更多
关键词 Hardware in the loop(HIL) Wheel slide protection(WSP) Degraded adhesion conditions Train brake
下载PDF
Innovative Design and Additive Manufacturing of Regenerative Cooling Thermal Protection System Based on the Triply Periodic Minimal Surface Porous Structure 被引量:2
4
作者 Xinglong Wang Cheng Wang +3 位作者 Xin Zhou Mingkang Zhang Peiyu Zhang Lei Wang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第5期495-508,共14页
The new regenerative cooling thermal protection system exhibits the multifunctional characteristics of load-carrying and heat exchange cooling,which are fundamental for the lightweight design and thermal protection of... The new regenerative cooling thermal protection system exhibits the multifunctional characteristics of load-carrying and heat exchange cooling,which are fundamental for the lightweight design and thermal protection of hypersonic vehicles.Triply periodic minimal surface(TPMS)is especially suitable for the structural design of the internal cavity of regenerative cooling structures owing to its excellent structural characteristics.In this study,test pieces were manufactured using Ti6Al4V lightweight material.We designed three types of porous test pieces,and the interior was filled with a TPMS lattice(Gyroid,Primitive,I-WP)with a porosity of 30%.All porous test pieces were manufactured via selective laser melting technology.A combination of experiments and finite element simulations were performed to study the selection of the internal cavity structure of the regenerative cooling thermal protection system.Hence,the relationship between the geometry and mechanical properties of a unit cell is established,and the deformation mechanism of the porous unit cell is clarified.Among the three types of porous test pieces,the weight of the test piece filled with the Gyroid unit cell was reduced by 8.21%,the average tensile strength was reduced by 17.7%compared to the solid test piece,while the average tensile strength of the Primitive and I-WP porous test pieces were decreased by 30.5%and 33.3%,respectively.Compared with the other two types of unit cells,Gyroid exhibited better mechanical conductivity characteristics.Its deformation process was characterised by stretching,shearing,and twisting,while the Primitive and I-WP unit cells underwent tensile deformation and tensile and shear deformation,respectively.The finite element predictions in the study agree well with the experimental results.The results can provide a basis for the design of regenerative cooling thermal protection system. 展开更多
关键词 Triply periodic minimal surface(TPMS) regenerative cooling thermal protection system selective laser melting mechanical properties fracture analysis
下载PDF
Bayesian belief-based model for reliability improvement of the digital reactor protection system 被引量:1
5
作者 Hanaa Torkey Amany S.Saber +2 位作者 Mohamed K.Shaat Ayman El-Sayed Marwa A.Shouman 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期55-73,共19页
The digital reactor protection system(RPS)is one of the most important digital instrumentation and control(I&C)systems utilized in nuclear power plants(NPPs).It ensures a safe reactor trip when the safety-related ... The digital reactor protection system(RPS)is one of the most important digital instrumentation and control(I&C)systems utilized in nuclear power plants(NPPs).It ensures a safe reactor trip when the safety-related parameters violate the operational limits and conditions of the reactor.Achieving high reliability and availability of digital RPS is essential to maintaining a high degree of reactor safety and cost savings.The main objective of this study is to develop a general methodology for improving the reliability of the RPS in NPP,based on a Bayesian Belief Network(BBN)model.The structure of BBN models is based on the incorporation of failure probability and downtime of the RPS I&C components.Various architectures with dual-state nodes for the I&C components were developed for reliability-sensitive analysis and availability optimization of the RPS and to demonstrate the effect of I&C components on the failure of the entire system.A reliability framework clarified as a reliability block diagram transformed into a BBN representation was constructed for each architecture to identify which one will fit the required reliability.The results showed that the highest availability obtained using the proposed method was 0.9999998.There are 120 experiments using two common component importance measures that are applied to define the impact of I&C modules,which revealed that some modules are more risky than others and have a larger effect on the failure of the digital RPS. 展开更多
关键词 Nuclear power plants Reactor protection system Bayesian belief network
下载PDF
Development of data acquisition and over-current protection systems for a suppressor-grid current with a neutral-beam ion source
6
作者 刘伟 胡纯栋 +5 位作者 刘胜 宋士花 汪金新 王艳 赵远哲 梁立振 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第12期154-158,共5页
Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheatin... Neutral beam injection is one of the effective auxiliary heating methods in magnetic-confinementfusion experiments. In order to acquire the suppressor-grid current signal and avoid the grid being damaged by overheating, a data acquisition and over-current protection system based on the PXI(PCI e Xtensions for Instrumentation) platform has been developed. The system consists of a current sensor, data acquisition module and over-current protection module. In the data acquisition module,the acquired data of one shot will be transferred in isolation and saved in a data-storage server in a txt file. It can also be recalled using NBWave for future analysis. The over-current protection module contains two modes: remote and local. This gives it the function of setting a threshold voltage remotely and locally, and the forbidden time of over-current protection also can be set by a host PC in remote mode. Experimental results demonstrate that the data acquisition and overcurrent protection system has the advantages of setting forbidden time and isolation transmission. 展开更多
关键词 neutral beam injection high-current ion source suppression grid current data acquisition and protection system
下载PDF
Porous Ultra-high Temperature Ceramics for Ultra-high Temperature Thermal Protection System
7
作者 LI Fei LIU Jixuan ZHANG Guojun 《China's Refractories》 CAS 2020年第4期23-28,共6页
Ultra-high temperature ceramics(UHTCs)are a family of borides,carbides and nitrides of transition elements such as hafnium,zirconium,tantalum and niobium.They exhibit the highest known melting points,good mechanical s... Ultra-high temperature ceramics(UHTCs)are a family of borides,carbides and nitrides of transition elements such as hafnium,zirconium,tantalum and niobium.They exhibit the highest known melting points,good mechanical strength,good chemical and thermal stability under certain conditions.In last decade,researchers dedicated to characterize porous UHTCs aiming to develop novel thermal insulating materials that could withstand temperatures over 2000℃.In this article,the preparation and characteristics of porous UHTCs were reviewed.Dry processing,colloidal processing and solution processing routes have been used to prepare porous UHTCs with porosities ranging from 5%to 97%and pore sizes ranging from hundreds of nanometers to hundreds of micrometers.The obtained porous UHTCs are chemically and dimensionally stable at temperatures up to 2000℃ during static state high-temperature thermal aging. 展开更多
关键词 ultra-high temperature ceramics porous ceramics thermal protection system extreme environments
下载PDF
Occupational Eye Lens Radiation Dose While Performing Interventional Procedures over 18 Months Using a Face-Shield Equipped Suspended Radiation Protection System
8
作者 Thomas J. Kwarcinski Andrew Lichliter +3 位作者 Joseph Oros Niraj KC Bryan Yoder Chet R. Rees 《Open Journal of Radiology》 2020年第2期101-114,共14页
<strong>Background: </strong>Numerous studies have demonstrated increasing evidence for cataractogenesis at lower levels of ionizing radiation than previously believed, with some suggesting possible absenc... <strong>Background: </strong>Numerous studies have demonstrated increasing evidence for cataractogenesis at lower levels of ionizing radiation than previously believed, with some suggesting possible absence of a threshold. Genetic differences between individuals also result in increased susceptibility in some operators, who might not be aware. European occupational exposure limits have been reduced and operators are seeking protective measures. <strong>Objective: </strong>To evaluate the protective effect of a face-shield equipped suspended protection system (Zero-Gravity<span style="white-space:nowrap;"><sup><span style="white-space:nowrap;">&reg;</span></sup></span>, TIDI Products, Neenah, WI) along with adherence to safety practices against radiation dose to the eye lens for an interventional radiologist performing a wide variety of procedures. <strong>Materials and Methods:</strong> In this institutional review board-approved single-institution study, one interventional radiologist wore a highly sensitive personnel monitoring dosimeter badge on the cap near the left eye while performing 299 procedures (3690 fluoroscopy minutes) over 18 consecutive months while utilizing the suspended protection system along with adherence to other generally recommended safety practices and movement away from the field during angiographic power injections. Dosimetry reports and procedural information were retrospectively reviewed. <strong>Results: </strong>Total lens dose equivalent to the left eye over 18 months was 0.11 mSv (annualized dose = 0.073 mSv, or 7.3 mRem). The patient-dose-area product standardized dose of 0.00576 <span style="white-space:nowrap;"><span style="white-space:nowrap;"><span style="white-space:nowrap;">&mu;</span></span></span>Sv/Gy<span style="white-space:nowrap;"><span style="white-space:nowrap;">&sdot;</span></span>cm<sup>2</sup> is well below reports of conventional lead aprons, shields, and protective eyewear. <strong>Conclusion: </strong>Eye exposures were kept to near-background levels using the materials and methods of this study while performing a wide variety of complex procedures from all positions around the patient. 展开更多
关键词 Lens Dose Reduction Radiation Safety Radiation-Induced Cataractogenesis Suspended protection system
下载PDF
Trademark Protection System in China
9
作者 Teng JiacaiTrademark OfficeState Administration for Industry andCommerce 《中国对外贸易》 1995年第7期32-33,共2页
China’s trademark business hasmade much progress since thecountry began its reform and open-uppolicy. In 1979 there were only 32,589registered trademarks, of which 5,130were foreign ones. With the establishmentand im... China’s trademark business hasmade much progress since thecountry began its reform and open-uppolicy. In 1979 there were only 32,589registered trademarks, of which 5,130were foreign ones. With the establishmentand improvement of the trademarkprotection system, the valid registeredtrademarks had reached 465,865 by theend of 1994, and 70,216 of them were for70 countries and regions. Such speed israre in the world. The features of the country’strademark protection system are asfollows: 1. Definite legal regulations andclear government 展开更多
关键词 Trademark protection system in China
下载PDF
Fault Detection Based on Hierarchical Cluster Analysis in Wide Area Backup Protection System 被引量:2
10
作者 Yagang ZHANG Jinfang ZHANG +1 位作者 Jing MA Zengping WANG 《Energy and Power Engineering》 2009年第1期21-27,共7页
In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated qui... In wide area backup protection of electric power systems, the prerequisite of protection device's accurate, fast and reliable performance is its corresponding fault type and fault location can be discriminated quickly and defined exactly. In our study, global information will be introduced into the backup protection system. By analyzing and computing real-time PMU measurements, basing on cluster analysis theory, we are using mainly hierarchical cluster analysis to search after the statistical laws of electrical quantities' marked changes. Then we carry out fast and exact detection of fault components and fault sections, and finally accomplish fault isolation. The facts show that the fault detection of fault component (fault section) can be performed successfully by hierarchical cluster analysis and calculation. The results of hierarchical cluster analysis are accurate and reliable, and the dendrograms of hierarchical cluster analysis are in intuition. 展开更多
关键词 WIDE area BACKUP protection PHASOR MEASUREMENT unit PMU WIDE area MEASUREMENT system WAMS fault detection cluster analysis
下载PDF
Evaluation of a Suspended Personal Radiation Protection System vs. Conventional Apron and Shields in Clinical Interventional Procedures 被引量:2
11
作者 Clare Savage Thomas M. Seale IV +3 位作者 Cathryn J. Shaw Bruner P. Angela Daniel Marichal Chet R. Rees 《Open Journal of Radiology》 2013年第3期143-151,共9页
Purpose: This clinical study compares conventional lead aprons and ancillary shields to a functionally weightless personal overhead-supported system with expanded coverage. Materials and Methods: Primary operators per... Purpose: This clinical study compares conventional lead aprons and ancillary shields to a functionally weightless personal overhead-supported system with expanded coverage. Materials and Methods: Primary operators performed procedures (N = 126, fluoroscopy minutes = 1209) using one of 2 methods of radiation protection and wearing dosimeters on multiple body locations. Method “LAS” (Lead-Apron+Shields): lead skirt, vest, thyroid shield, with 100% use of under-table shield, side shield, and mobile suspended lead-acrylic shield. Method “Zgrav”: ZeroGravity system (CFI Medical Solutions) with variable use of shielding. The studied early model moving with the operator had a curved lead-acrylic head shield (0.5 mm Pb) and expansive lead apron (0.5 - 1.0 mm Pb) that covered leg to distal calf and proximal arm to elbow, and a drape that permitted sterile entry and exit. Study was institutional review board approved and HIPPA-compliant. Results: Measured with a sensitive electronic dosimeter, eye exposures were 99% (P 0.001) reduced for Zgrav with upgraded face shield vs. LAS, regardless of use or non-use of suspended shield with Zgrav. With optically stimulated luminescence (OSL) dosimeters, operator exposures, standardized to minutes of fluoroscopy and Fluoroscopic Patient Dose Area Product, were reduced by 87% - 100% for eye & head, neck, humerus, and tibia (Zgrav vs. LAS). Overall eye & head exposure reduction for entire study was 94%. Non-equivalence of torso exposures was not demonstrated. A brief user survey showed ergonomic advantages of Zgrav. Conclusion: Compared to conventional lead aprons with shields, the suspended system provided superior operator protection during interventional fluoroscopy, allowing operators to perform procedures without potentially obstructive shields. 展开更多
关键词 RADIATION protection RADIATION FLUOROSCOPY
下载PDF
Protection Systems for Reinforced Concrete with Corrosion Inhibitors 被引量:2
12
作者 Angeliki Zacharopoulou Eugenia Zacharopoulou George Batis 《Open Journal of Metal》 2014年第4期86-92,共7页
This paper examines the use of corrosion inhibitors in order to protect the reinforcement of concrete. For this purpose mortar specimens were constructed with or without corrosion inhibitors and were partially immerse... This paper examines the use of corrosion inhibitors in order to protect the reinforcement of concrete. For this purpose mortar specimens were constructed with or without corrosion inhibitors and were partially immersed in sodium chloride. Corrosion inhibitors were used as admixture into concrete and were sprayed on the external surface of mortar specimens. In all mortar specimens, electric junction between reinforcements was achieved. The methods that were used for the evaluation of the reinforcement corrosion in concrete, included half-cell potential measurements, polarization curves of reinforced rebars and mass loss of the reinforcement. Finally, the durability of concrete after the use of corrosion inhibitors was also examined. 展开更多
关键词 REINFORCED CORROSION INHIBITORS CORROSION protection
下载PDF
Two Degree-of-Freedom Dynamic Theoretical Model on Tile Thermal Protection System
13
作者 HUANG Jie YAO Weixing +3 位作者 KONG Bin YANG Jiayong WANG Man ZHANG Qingmao 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第1期139-145,共7页
In order to study the dynamic behaviors of the thermal protection system(TPS)and dynamic strength of the strain-isolation-pad(SIP),a two degree-of-freedom dynamic theoretical model is presented under the acoustic exci... In order to study the dynamic behaviors of the thermal protection system(TPS)and dynamic strength of the strain-isolation-pad(SIP),a two degree-of-freedom dynamic theoretical model is presented under the acoustic excitation and base excitation. The tile and SIP are both considered as the elastic body and simplified as a mass point,a linear spring and a damping element. The theoretical solutions are derived,and the reasonability of theoretical model is verified by comparing the theoretical results with the numerical results. Finally,the influences on the dynamic responses of TPS by the structural damping coefficient of TPS,elasticity modulus and thickness of SIP are analyzed.The results show that the material with higher damping,and SIP with thicker size and lower elastic modulus should be considered to reduce the dynamic responses and intensify the security of TPS. The researches provide a theoretical reference for studying the dynamic behaviors of TPS and the dynamic strength of SIP. Besides,the dynamic theoretical model can be used as a quick analysis tool for analyzing the dynamic responses of TPS during the initial design phase. 展开更多
关键词 thermal protection system DYNAMIC THEORETICAL model ACOUSTIC EXCITATION base EXCITATION
下载PDF
Evolution logic complementary needs and reform path of China’s marine ecological protection system
14
作者 Qi Chen Qiuguang Hu 《Chinese Journal of Population,Resources and Environment》 2021年第2期193-202,共10页
The issue of marine ecology is an institutional one.China’s marine ecological protection system has gone through a process of development from scratch to existence and from less to more.However,there are still many p... The issue of marine ecology is an institutional one.China’s marine ecological protection system has gone through a process of development from scratch to existence and from less to more.However,there are still many problems to be solved,such as whether a variety of complex systems can form a joint force of governance,and whether the rear system failures,deficiencies,and conflicts.Therefore,this paper reviews the evolution logic of China’s marine ecological protection system,explores the complementary space of the existing system from the perspective of institutional complementarity,and analyzes the path of institutional reform of supplement,amendment,and coordination,to promote the effective transition of marine ecological protection system emphasizing quality over quantity.The evolution of China’s marine ecological protection system can be divided into three stages:initial establishment,steady progression,and gradual transformation,showing a trend characterized by a changing governance mode from land-sea division to land-sea integration,a changing supervision mode from government only to multi-institution coordination,a changing safeguard mode from standard norms to the legal system.The internal motivation of promoting the evolution of the marine ecological protection system is the link age between the long-overdue institutional derived demand and supply,and between institutional cost constraints and institutional income drivers.Marine ecological protection is a complex and systematic project across regions and departments,and the link age between different ecological protection systems is crucial.Based on the theory of institutional complementarity,this study finds that China’s marine ecological protection system has great complementarity needs in three aspects:protection subject,protection means,and protection process.Among them,the problem of a single unitary protection subject is mainly caused by the lack of system,the low efficiency of protection means is mainly affected by the lack of system adaptability,and the separation of protection process mainly reflects the contradiction of system incongruity and mismatch.Based on this,the supplement of China’s marine ecological protection system should focus on the government’s responsibilities and the cultivation of multiple subjects.The revision of the system should focus on the further improvement of non-governmental mechanisms such as market incentives and information disclosure.The coordination of the system should be based on the whole process from pre regulation preparations to post-regulation review,in order to promote the effective connection and cooperation of policy tools. 展开更多
关键词 Marine ecological protection Institutional evolution Institutional complementary Governance system
下载PDF
The Mental Protection System for Protective Behaviors: The Social Brain and the Mental Immune System
15
作者 Dingyu Chung 《Journal of Behavioral and Brain Science》 2018年第1期31-55,共25页
The physical protection system of the body consists of the protective organs for vulnerable body parts-functions and the protective countermeasures against invaders (pathogens), but to survive, the body also requires ... The physical protection system of the body consists of the protective organs for vulnerable body parts-functions and the protective countermeasures against invaders (pathogens), but to survive, the body also requires the protective social groups for vulnerable social members-functions and the protective instinctive mental countermeasures against adversities such as hardship, danger, and unfamiliarity-uncertainty. As a result, this paper proposes that the mental protection system of the body consists of the social brain to set up the protective social groups for vulnerable social members-functions and the mental immune system to produce the protective mental countermeasures against adversities. This paper proposes that from the social brain, the protective social groups include alliance group for vulnerable individuals, kinship-friendship group for vulnerable children, interdependent specialists group for vulnerable pregnant females, territorial group for social boundary, connective group for social connection, and competitive group for social competition. From the mental immune system, the mental protective countermeasures include comforter against hardship, hyperactivity against danger, phobia against unfamiliarity-uncertainty, and rationality against unfamiliarity-uncertainty. The overactive mental immune system causes mental allergies and auto immune diseases as personality-mental disorders against ubiquitous harmful and harmless perceived adversities, correlating to physical allergies and auto immune diseases against ubiquitous harmful and harmless detected invaders. The mental protection system also produces personality traits, social moralities, social organizations, social systems, religions, and cultures as described in this paper. The mental protective system is the source of protective behaviors. 展开更多
关键词 MENTAL protection system SOCIAL Brain MENTAL Immune system Big Five PERSONALITY TRAITS SOCIAL system TRAITS PERSONALITY Disorders Psychotherapy Religions Western Culture Eastern Culture Protective BEHAVIORS
下载PDF
Research and improvement of leakage protection system in traction motor
16
作者 陈霞 席新博 +3 位作者 褚鹏 裴咏春 尹俊华 王德兰 《Journal of Measurement Science and Instrumentation》 CAS 2012年第3期294-297,共4页
Because the leakage protection circuit in traction motor of coal mining machine is impacted by frequency converter devices,malfunctions appear frequently.This paper makes an in-depth analysis,proposes a solution of us... Because the leakage protection circuit in traction motor of coal mining machine is impacted by frequency converter devices,malfunctions appear frequently.This paper makes an in-depth analysis,proposes a solution of using the subtraction circuit to offset interference signals and conducts a simulation analysis.The above scheme,which is simple and easily realized,can improve the reliability of leakage protection device in traction motor. 展开更多
关键词 coal mining machine traction motor leakage protection frequency converter
下载PDF
Optimal Piling Network Corrosion Protection System for Al-Zubair Harbor
17
作者 Mohammed H. Hafiz Wisam K. Hamdan Ruaa Kaream Salman 《Journal of Surface Engineered Materials and Advanced Technology》 2012年第4期249-257,共9页
Cathodic protection is an effective electrochemical technique for preventing corrosion of metallic structures, for large structures like piles network impressed current cathodic protection (ICCP) system is usually pre... Cathodic protection is an effective electrochemical technique for preventing corrosion of metallic structures, for large structures like piles network impressed current cathodic protection (ICCP) system is usually preferred. The main aim of this study is to obtain the optimum protection potential that would provide a full cathodic protection for steel piles net-work immersed in sea water at Al-Zubair harbor. The effect of one immeasurable factor (path of anode (χ1)) and two measurable factors (position of anode (χ2) and voltage of power supply (χ3)) on protection potential are studied. Each factor has three different levels (high, medium, and low). Twenty-seven experiments were conducted based on a full factorial design of experiments. The results show that, a sufficient protection for three cathodes can be provided through the electrical circuit connecting them within the appropriate geometric shape.The protection potential is icreased with increasing the voltage of power supply and decreasing of distance between the anode and cathodes (piles network). 展开更多
关键词 Impressed Current Cathodic protection PILES NETWORK Path of ANODE Position of ANODE OPTIMAL Combination
下载PDF
Some Technical Solutions for Environmental Protection System during Accidents at Nuclear Power Plants
18
作者 Sergey A. Kulyukhin Igor’ A. Rumer +5 位作者 Viktor M. Berkovich Gennadii S. Taranov Ivan V. Yagodkin Viktor P. Osipov Sergey S. Skvortsov Leo N. Falkovskii 《World Journal of Engineering and Technology》 2017年第4期1-11,共11页
The paper reports some technical solutions, which suggested or used for increasing of environmental protection during accidents at NPPs. For NNPs with two protective shells and pressure release system such as WWER-100... The paper reports some technical solutions, which suggested or used for increasing of environmental protection during accidents at NPPs. For NNPs with two protective shells and pressure release system such as WWER-1000 a comprehensive, passive-mode environmental protection system of decontamination of the radioactive steam-air mixture from the containment and the intercontainment area was suggested. This system includes the “wet” stage (scrubbers, etc.), the “dry” stage (sorption module), and also an ejector, which in a passive mode is capable of solving the multi-purpose task of decontamination of the air-steam mixture. For WWER-440/230 NPPs three protection levels: 1) a jet-vortex condenser;2) the spray system;3) a sorption module were suggested and installed. For modern designs of new generation NPPs, which do not provide for pressure release systems, a new passive filtering system together with the passive heat-removal system, which can be used during severe accidents in case all power supply units become unavailable, was proposed and after modernization was installed at the KudanKulam NPP (India). 展开更多
关键词 NUCLEAR Power PLANTS SEVERE ACCIDENT Environment protection RADIOACTIVE Steam-Air Phase
下载PDF
Overview of Analysis on State Evaluation of Relaying Protection System
19
作者 Wanqing Li Pinduan Hu 《Journal of Power and Energy Engineering》 2019年第5期1-7,共7页
With the rapid development of the smart grid, it is necessary to do good corresponding work in relaying protection so as to meet the overall requirements of the smart grid better. So we must focus on the state divisio... With the rapid development of the smart grid, it is necessary to do good corresponding work in relaying protection so as to meet the overall requirements of the smart grid better. So we must focus on the state division, risk analysis and fault diagnosis methods in the relaying protection system, in the basis of fully understanding the advantages and disadvantages of relaying protection system, and then improve the problems existing of relaying protection system at this stage according to the actual situation. This paper aims at the overview of analysis on state evaluation of relaying protection systems. 展开更多
关键词 RELAYING protection system STATE EVALUATION Research OVERVIEW
下载PDF
Fault Detection and Protection System of Electric Railway Substation
20
作者 Dae-Seok Kang Woo-Sik Won +1 位作者 Byung-Lib Ahn Byeong-Gon Lee 《Journal of Energy and Power Engineering》 2022年第4期147-155,共9页
The industrial power systems are moving to digital networks,and unmanned systems are increasing recently with the technological development of information and communication technology.In particular,reliability of syst... The industrial power systems are moving to digital networks,and unmanned systems are increasing recently with the technological development of information and communication technology.In particular,reliability of system operation is very important for stable power supply.Most industrial power distribution facilities use a 154 kV or 22.9 kV extra HV(high voltage)power system,and a special monitoring system is required because a large loss occurs when an error occurs in the power facility in the field.Although digital protection relay(IED;intelligent electronic device)and FR(fault recorder)are applied to the field to protect the power system,various improvement activities are still ongoing.In this paper,a 22.9 kV high-voltage panel and its test bed,which are widely used in railway stations,tunnels,substations and large plants,were tested as test subjects.The developed fault detection system automatically starts the AL(auto-lock)circuit or outputs an alarm signal to user by monitoring in real time problems such as CT(current transformer)-open and poor-contact that the existing digital protection relay cannot cover.In addition,it is intended to increase the safety and reliability of the power system by blocking various accidents in the system in advance and accurately analyzing the causes of faults with the developed fault detection system. 展开更多
关键词 CT open poor contact fault detection protection relay SUBSTATION HV panel
下载PDF
上一页 1 2 162 下一页 到第
使用帮助 返回顶部