Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)...Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)after fatigue resistance testing at different cycles and semidiameter of screw insertion area of micro-CT image was compared between the micro-dynamic and traditional pedicle screws.Methods Forty lumbar vertebrae received a traditional pedicle screw on one side and a micro-dynamic pedicle screw on the other side as follows:15 vertebrae underwent instant pull-out testing(group A,traditional vs.group B,micro-dynamic);15 vertebrae underwent pull-out test after 5000-cyclic fatigue loading(group C,traditional vs.group D,micro-dynamic);and 10 vertebrae underwent pull-out test after 10000-cyclic fatigue loading(group E,traditional vs.group F,micro-dynamic).All vertebrae that after fatigue loading were scanned by using micro-ct to check the semidiameter of screw insertion area.The PPF,normalized PPF(PPFn),bone mineral density(BMD)and diameter of screw insertion area were compared between all groups.Results The BMD showed a weak significant correlation with PPF(r=0.252,P=0.024).The PPF in groups A and B(P=0.485),and groups C and D(P=0.184)did not show significant difference.However,the PPF in group F was significantly greater than that measured in group E(P=0.005).The PPFn of groups A,C,and E significantly decreased as the number of cycles increased(P=0.015).Meanwhile,the PPFn of groups B,D,and F remained consistent regardless of the number of cycles(P=0.367). The semidiameter of traditional pedicle screw insertion area was significantly larger than that of micro-dynamic pedicle screw insertion area(P<0.001).Conclusions This study compared the performance of a micro-dynamic pedicle screw versus that of a traditional pedicle screw using pull-out testing and micro-CT.The results showed that the micro-dynamic pedicle screw provides similar resistance in lowcycle fatigue testing and favorable resistance in high-cycle fatigue testing versus the traditional pedicle screw.The micro-dynamic pedicle screw provides stronger fixation stability versus the traditional pedicle screw,especially in high-cyclic fatigue loading condition versus the traditional pedicle screws.展开更多
Laboratory pull-out tests were conducted on the following rock bolts and cable bolts:steel rebars,smooth steel bars,fiberglass reinforced polymer threaded bolts,flexible cable bolts,IR5/IN special cable bolts and Mini...Laboratory pull-out tests were conducted on the following rock bolts and cable bolts:steel rebars,smooth steel bars,fiberglass reinforced polymer threaded bolts,flexible cable bolts,IR5/IN special cable bolts and Mini-cage cable bolts.The diameter of the tested bolts was between 16 mm and 26 mm.The bolts were grouted in a sandstone sample using resin or cement grouts.The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample.In most tests,the rate of displacement was about 0.02 mm/s.The tests were performed using a pull-out bench that allows testing a wide range of parameters.This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response(rock bolts and cable bolts).It also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole,which cannot be neglected when the test results are used to assess the bolt-grout or the grouterock interface.展开更多
Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a ...Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a number of researchers. However, no attention has been paid to tapered suction caissons. This paper deals with the performance of tapered suction caissons under vertical pull-out loads. A numerical approach is used for this purpose. The numerical model is first verified against test data available for common upright caissons. The verified model is then used to study the pullout performance of tapered suction caissons. It is noticed that the pull-out capacities exhibited by tapered suction caissons are in general considerably higher than those from their corresponding traditional upright caissons. To obtain an insight into this superior behaviour, effects from certain soil/caisson/drainage parameters on the pull-out capacity of tapered suction caissons are studied. Soil cohesion is noticed to have a linear improving effect on the capacity of both upright and ta- pered suction caissons. The soil internal friction angle is noticed to have an exponential increasing effect on the pull-out capacity. With a constant caisson diameter, an increase in the aspect ratio is seen to particularly influence the pull-out capacity. With a constant caisson length, an increase in the aspect ratio is discovered to result in non-linear decrease in the pull-out capacity. Under undrained conditions, tapered models generally show less sensitivity to above mentioned soil/caisson parameters as compared with those under drained conditions.展开更多
An elastic analysis of an internal central crack with bridging fibers parallel to the free surface in an infinite orthotropic anisotropic elastic plane was performed. A dynamic model of bridging fiber pull-out of comp...An elastic analysis of an internal central crack with bridging fibers parallel to the free surface in an infinite orthotropic anisotropic elastic plane was performed. A dynamic model of bridging fiber pull-out of composite materials was presented. Resultingly the fiber failure is governed by maximum tensile stress, the fiber breaks and hence the crack extension should occur in self-similar fashion. By the methods of complex functions, the problem studied can be transformed into the dynamic model to the Reimann-Hilbert mixed boundary value problem, and a straightforward and easy analytical solution is presented. Analytical study on the crack propagation subjected to a ladder load and an instantaneous pulse loading is obtained respectively for orthotropic anisotropic body. By utilizing the solution, the concrete solutions of this model are attained by ways of superposition.展开更多
Fibre-matrix interface is known to have contribution to the mechanical performance of fibre-reinforced composite by its potential for load transfer between the fibre and the matrix. Such load transfer is of great impo...Fibre-matrix interface is known to have contribution to the mechanical performance of fibre-reinforced composite by its potential for load transfer between the fibre and the matrix. Such load transfer is of great importance in dentistry when a post is used for fixing a ceramic crown on the tooth. In this study, a pull-out test was carried out to analyse the interfacial properties of a steel fibre embedded in a polyester and epoxy matrices. It was found that the fibre-matrix interface is debonded on the whole embedded length when the fibre stress reached the debonding stress. Then, the fibre stress fell down to the initial extraction stress required to pulling out the debonded fibre from the matrix. Both debonding stress and initial extraction stress initiated a linear increase with the implantation length after the debonding stress reached horizontal asymptotes. To analyse the fibre-matrix load transfer before debonding, an analytical shear-lag model was adopted to in this test conditions. Fitting the experimental results with the analytical model provided the interfacial shear strength. By considering the Coulomb friction at the fibre-matrix interface during the fibre extraction process, an analytical model which considers Poisson's effects on both fibre and matrix, was developed. In this model, knowledge of the initial extraction stress of the fibre provides the residual normal stress at the fibre-matrix interface.展开更多
The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and...The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and the others had the shells with concave bits. The strength of bolts was measured by applying a standard pull-out test;the results confirmed that the strength of shells with convex edges was remarkably more than the strength of other shells. Furthermore, a two-dimensional DEM model of the test was developed by a particle flow code;the obtained results showed that the reaction of rock particles to the contacts occurring between the convex edges and earth was considerably more than those of the concave bits. In the other words, the convex edges transferred the pull-out force into a large area of the surrounded rock, causing these bolts to have the highest resistance against earth movements.展开更多
The nature of the pull-out system of carbon nanorope/polyethylene(CNRP/PE) composite is studied by using molecular dynamics approach. The deformation of the CNRP/PE composites in pull-out process is exhibited. The i...The nature of the pull-out system of carbon nanorope/polyethylene(CNRP/PE) composite is studied by using molecular dynamics approach. The deformation of the CNRP/PE composites in pull-out process is exhibited. The influence of twisting deformation on the interfacial interaction of the composites is investigated. The results show that the energy of the pull-out system is conserved; and the interfacial bonding is weak resulting in a sliding failure of the CNRP inside PE matrix.展开更多
The effective utilisation of steel fibre reinforced concrete (SFRC) requires in-depth and detailed understanding of bonding mechanisms governing the tensile behaviour. In response to this demand, this study presents a...The effective utilisation of steel fibre reinforced concrete (SFRC) requires in-depth and detailed understanding of bonding mechanisms governing the tensile behaviour. In response to this demand, this study presents an empirical description of the axial force required to pull out a hooked end steel fibre from a cementitious matrix. It is based upon consistent experimental tests that show the force versus displacement plot is formed from a sequence of events in which partial and full debonding at the interface is followed by bending of the hook knee to raise the force to its maximum. A loss of peak force occurs with the reversed plasticity involved in a full straightening of the fibre that precedes the rapid sliding to its full removal under a falling force. The stages are assembled in the said order with a piecewise connection between linear segments and a curve of exponential decay. A power law can be introduced to describe the knee bending stage if preferred. The normalised co-ordinates were adopted for the simple mathematical discontinuous function of the full pull-out process. Normalising force and displacement for hooked fibre is based upon the maximum values found for straight fibre pull out. This would apply to an overall embedded length of unity and a unit peak force for a full debonding of straight fibre in similar materials. For hooked fibre the normalised co-ordinates given refer to the initiation and duration of each event to be tabulated at fractions of the embedded length with multiples of that force. Such predictions are seen to be in good agreement with average pull-out response curves.展开更多
We demonstrate that,in a simple linearly-polarized plane wave,the optical pulling forces on nanoparticle clusters with gain can be induced by the Fano-like resonance.The numerical results based on the full-wave calcul...We demonstrate that,in a simple linearly-polarized plane wave,the optical pulling forces on nanoparticle clusters with gain can be induced by the Fano-like resonance.The numerical results based on the full-wave calculation show that the optical pulling forces can be attributed to the recoil forces for the nanoparticle clusters composed of dipolar nanoparticles with three different configurations.Interestingly,the recoil forces giving rise to optical pulling forces are exactly dominated by the coupling term between the electric and magnetic dipoles excited in the nanoparticle clusters,while other higherorder terms have a negligible contribution.In addition,the optical pulling force can be tailored by modulating the Fano-like resonance via either the particle size or the gain magnitude,offering an alternative freedom degree for optical manipulations of particle clusters.展开更多
A rockbolt acting in the rock mass is subjected to the combined action of the pull-out load and confining pressure, and the bond quality of the rockbolt directly affects the stability of the roadway and cavern. Theref...A rockbolt acting in the rock mass is subjected to the combined action of the pull-out load and confining pressure, and the bond quality of the rockbolt directly affects the stability of the roadway and cavern. Therefore, in this study, confining pressure and pull-out load are applied to grouted rockbolt systems with bond defects by a numerical simulation method, and the rockbolt is detected by ultrasonic guided waves to study the propagation law of ultrasonic guided waves in defective rockbolt systems and the bond quality of rockbolts under the combined action of pull-out load and confining pressure. The numerical simulation results show that the length and location of bond defects can be detected by ultrasonic guided waves under the combined action of pull-out load and confining pressure. Under no pull-out load, with increasing confining pressure, the low-frequency part of the guided wave frequency in the rockbolt increases, the high-frequency part decreases, the weakening effect of the confining pressure on the guided wave propagation law increases, and the bond quality of the rockbolt increases. The existence of defects cannot change the strengthening effect of the confining pressure on the guided wave propagation law under the same pull-out load or the weakening effect of the pull-out load on the guided wave propagation law under the same confining pressure.展开更多
基金supported by the National Natural Science Foundation of China ( 31670957)
文摘Objective To investigate the effectiveness of the micro-dynamic pedicle screw for the prevention of loosening between the screw and bone surface in lumbar spinal fusion.For this evaluation,the peek pull-out force(PPF)after fatigue resistance testing at different cycles and semidiameter of screw insertion area of micro-CT image was compared between the micro-dynamic and traditional pedicle screws.Methods Forty lumbar vertebrae received a traditional pedicle screw on one side and a micro-dynamic pedicle screw on the other side as follows:15 vertebrae underwent instant pull-out testing(group A,traditional vs.group B,micro-dynamic);15 vertebrae underwent pull-out test after 5000-cyclic fatigue loading(group C,traditional vs.group D,micro-dynamic);and 10 vertebrae underwent pull-out test after 10000-cyclic fatigue loading(group E,traditional vs.group F,micro-dynamic).All vertebrae that after fatigue loading were scanned by using micro-ct to check the semidiameter of screw insertion area.The PPF,normalized PPF(PPFn),bone mineral density(BMD)and diameter of screw insertion area were compared between all groups.Results The BMD showed a weak significant correlation with PPF(r=0.252,P=0.024).The PPF in groups A and B(P=0.485),and groups C and D(P=0.184)did not show significant difference.However,the PPF in group F was significantly greater than that measured in group E(P=0.005).The PPFn of groups A,C,and E significantly decreased as the number of cycles increased(P=0.015).Meanwhile,the PPFn of groups B,D,and F remained consistent regardless of the number of cycles(P=0.367). The semidiameter of traditional pedicle screw insertion area was significantly larger than that of micro-dynamic pedicle screw insertion area(P<0.001).Conclusions This study compared the performance of a micro-dynamic pedicle screw versus that of a traditional pedicle screw using pull-out testing and micro-CT.The results showed that the micro-dynamic pedicle screw provides similar resistance in lowcycle fatigue testing and favorable resistance in high-cycle fatigue testing versus the traditional pedicle screw.The micro-dynamic pedicle screw provides stronger fixation stability versus the traditional pedicle screw,especially in high-cyclic fatigue loading condition versus the traditional pedicle screws.
基金supported by the European Research Fund for Coal and Steel in the AMSSTED Programme RFCR-CT-2013-00001
文摘Laboratory pull-out tests were conducted on the following rock bolts and cable bolts:steel rebars,smooth steel bars,fiberglass reinforced polymer threaded bolts,flexible cable bolts,IR5/IN special cable bolts and Mini-cage cable bolts.The diameter of the tested bolts was between 16 mm and 26 mm.The bolts were grouted in a sandstone sample using resin or cement grouts.The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample.In most tests,the rate of displacement was about 0.02 mm/s.The tests were performed using a pull-out bench that allows testing a wide range of parameters.This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response(rock bolts and cable bolts).It also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole,which cannot be neglected when the test results are used to assess the bolt-grout or the grouterock interface.
文摘Suction caissons have been widely used as anchors and foundations for floating and fixed offshore platforms. The pull-out performance of conventional suction caissons (with upright walls) has been investigated by a number of researchers. However, no attention has been paid to tapered suction caissons. This paper deals with the performance of tapered suction caissons under vertical pull-out loads. A numerical approach is used for this purpose. The numerical model is first verified against test data available for common upright caissons. The verified model is then used to study the pullout performance of tapered suction caissons. It is noticed that the pull-out capacities exhibited by tapered suction caissons are in general considerably higher than those from their corresponding traditional upright caissons. To obtain an insight into this superior behaviour, effects from certain soil/caisson/drainage parameters on the pull-out capacity of tapered suction caissons are studied. Soil cohesion is noticed to have a linear improving effect on the capacity of both upright and ta- pered suction caissons. The soil internal friction angle is noticed to have an exponential increasing effect on the pull-out capacity. With a constant caisson diameter, an increase in the aspect ratio is seen to particularly influence the pull-out capacity. With a constant caisson length, an increase in the aspect ratio is discovered to result in non-linear decrease in the pull-out capacity. Under undrained conditions, tapered models generally show less sensitivity to above mentioned soil/caisson parameters as compared with those under drained conditions.
文摘An elastic analysis of an internal central crack with bridging fibers parallel to the free surface in an infinite orthotropic anisotropic elastic plane was performed. A dynamic model of bridging fiber pull-out of composite materials was presented. Resultingly the fiber failure is governed by maximum tensile stress, the fiber breaks and hence the crack extension should occur in self-similar fashion. By the methods of complex functions, the problem studied can be transformed into the dynamic model to the Reimann-Hilbert mixed boundary value problem, and a straightforward and easy analytical solution is presented. Analytical study on the crack propagation subjected to a ladder load and an instantaneous pulse loading is obtained respectively for orthotropic anisotropic body. By utilizing the solution, the concrete solutions of this model are attained by ways of superposition.
文摘Fibre-matrix interface is known to have contribution to the mechanical performance of fibre-reinforced composite by its potential for load transfer between the fibre and the matrix. Such load transfer is of great importance in dentistry when a post is used for fixing a ceramic crown on the tooth. In this study, a pull-out test was carried out to analyse the interfacial properties of a steel fibre embedded in a polyester and epoxy matrices. It was found that the fibre-matrix interface is debonded on the whole embedded length when the fibre stress reached the debonding stress. Then, the fibre stress fell down to the initial extraction stress required to pulling out the debonded fibre from the matrix. Both debonding stress and initial extraction stress initiated a linear increase with the implantation length after the debonding stress reached horizontal asymptotes. To analyse the fibre-matrix load transfer before debonding, an analytical shear-lag model was adopted to in this test conditions. Fitting the experimental results with the analytical model provided the interfacial shear strength. By considering the Coulomb friction at the fibre-matrix interface during the fibre extraction process, an analytical model which considers Poisson's effects on both fibre and matrix, was developed. In this model, knowledge of the initial extraction stress of the fibre provides the residual normal stress at the fibre-matrix interface.
文摘The reaction of earth to pull-out process of frictional rock bolts was here modeled by the distinct element method (DEM). Ten frictional bolts were prepared;the expanding shells of five bolts included convex edges and the others had the shells with concave bits. The strength of bolts was measured by applying a standard pull-out test;the results confirmed that the strength of shells with convex edges was remarkably more than the strength of other shells. Furthermore, a two-dimensional DEM model of the test was developed by a particle flow code;the obtained results showed that the reaction of rock particles to the contacts occurring between the convex edges and earth was considerably more than those of the concave bits. In the other words, the convex edges transferred the pull-out force into a large area of the surrounded rock, causing these bolts to have the highest resistance against earth movements.
基金Funded by the National Natural Science Foundation of China(Nos.11172012 and 11472020)
文摘The nature of the pull-out system of carbon nanorope/polyethylene(CNRP/PE) composite is studied by using molecular dynamics approach. The deformation of the CNRP/PE composites in pull-out process is exhibited. The influence of twisting deformation on the interfacial interaction of the composites is investigated. The results show that the energy of the pull-out system is conserved; and the interfacial bonding is weak resulting in a sliding failure of the CNRP inside PE matrix.
文摘The effective utilisation of steel fibre reinforced concrete (SFRC) requires in-depth and detailed understanding of bonding mechanisms governing the tensile behaviour. In response to this demand, this study presents an empirical description of the axial force required to pull out a hooked end steel fibre from a cementitious matrix. It is based upon consistent experimental tests that show the force versus displacement plot is formed from a sequence of events in which partial and full debonding at the interface is followed by bending of the hook knee to raise the force to its maximum. A loss of peak force occurs with the reversed plasticity involved in a full straightening of the fibre that precedes the rapid sliding to its full removal under a falling force. The stages are assembled in the said order with a piecewise connection between linear segments and a curve of exponential decay. A power law can be introduced to describe the knee bending stage if preferred. The normalised co-ordinates were adopted for the simple mathematical discontinuous function of the full pull-out process. Normalising force and displacement for hooked fibre is based upon the maximum values found for straight fibre pull out. This would apply to an overall embedded length of unity and a unit peak force for a full debonding of straight fibre in similar materials. For hooked fibre the normalised co-ordinates given refer to the initiation and duration of each event to be tabulated at fractions of the embedded length with multiples of that force. Such predictions are seen to be in good agreement with average pull-out response curves.
基金Project supported by the Natural Science Foundation of Guangxi Province of China (Grant No.2021GXNSFDA196001)the National Natural Science Foundation of China (Grant Nos.12174076,12074084,and 12204117)+1 种基金Guangxi Science and Technology Project (Grant Nos.AD22080042 and AB21220052)Open Project of State Key Laboratory of Surface Physics in Fudan University (Grant No.KF2022_15)。
文摘We demonstrate that,in a simple linearly-polarized plane wave,the optical pulling forces on nanoparticle clusters with gain can be induced by the Fano-like resonance.The numerical results based on the full-wave calculation show that the optical pulling forces can be attributed to the recoil forces for the nanoparticle clusters composed of dipolar nanoparticles with three different configurations.Interestingly,the recoil forces giving rise to optical pulling forces are exactly dominated by the coupling term between the electric and magnetic dipoles excited in the nanoparticle clusters,while other higherorder terms have a negligible contribution.In addition,the optical pulling force can be tailored by modulating the Fano-like resonance via either the particle size or the gain magnitude,offering an alternative freedom degree for optical manipulations of particle clusters.
文摘A rockbolt acting in the rock mass is subjected to the combined action of the pull-out load and confining pressure, and the bond quality of the rockbolt directly affects the stability of the roadway and cavern. Therefore, in this study, confining pressure and pull-out load are applied to grouted rockbolt systems with bond defects by a numerical simulation method, and the rockbolt is detected by ultrasonic guided waves to study the propagation law of ultrasonic guided waves in defective rockbolt systems and the bond quality of rockbolts under the combined action of pull-out load and confining pressure. The numerical simulation results show that the length and location of bond defects can be detected by ultrasonic guided waves under the combined action of pull-out load and confining pressure. Under no pull-out load, with increasing confining pressure, the low-frequency part of the guided wave frequency in the rockbolt increases, the high-frequency part decreases, the weakening effect of the confining pressure on the guided wave propagation law increases, and the bond quality of the rockbolt increases. The existence of defects cannot change the strengthening effect of the confining pressure on the guided wave propagation law under the same pull-out load or the weakening effect of the pull-out load on the guided wave propagation law under the same confining pressure.