Cardiac output(CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractili...Cardiac output(CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractility and afterload. Moreover it gives important information about tissue perfusion and oxygen delivery. CO can be measured by various methods and thermodilution method using pulmonary artery catheter(PAC) is till date considered as gold standard method. Complications associated with PAC led to development of newer methods which are minimally or non-invasive. Newer methods fulfil other properties like continuous and reproducible reading, cost effective, reliable during various physiological states and have fast response time. These methods are validated against the gold standard with good level agreement. In this review we have discussed various newer methods of CO monitoring and their effectiveness in clinical use.展开更多
Background Respiratory failure is the main cause of death in acute organophosphorus pesticide poisoning. In this study, a pulse-induced contour cardiac output monitor was used to evaluate the respiratory status in a p...Background Respiratory failure is the main cause of death in acute organophosphorus pesticide poisoning. In this study, a pulse-induced contour cardiac output monitor was used to evaluate the respiratory status in a pig model of acute dichlorvos poisoning. Methods Twenty female pigs were randomly allocated to dichlorvos (n=7), atropine (n=7), and control (n=6) groups. In the dichlorvos group, pigs were administered 80% emulsifiable dichlorvos (100 mg/kg) via a gastric tube. In the atropine group, pigs were similarly administered dichlorvos, and 0.5 hours later, atropine was injected to attain and maintain atropinization. The control group was administered saline solution. Arterial blood gas was measured at 0, 0.5, 1, 2, 4, and 6 hours post-injection. The extravascular lung water index and pulmonary vascular permeability index were recorded by the pulse-induced contour cardiac output monitor. At termination of the study, the animals were euthanized, the lung wet-to-dry weight ratio was determined, and histopathology was observed. Results In the dichlorvos group, the extravascular lung water index and pulmonary vascular permeability index were substantially increased from 0.5 hours and were particularly high within 1 hour. In the atropine group, these indices increased initially, but decreased from the 1-hour mark. The control group exhibited no obvious changes. In both the dichlorvos and atropine groups, the extravascular lung water index was negatively correlated with partial pressure of oxygen/fraction of inspiration oxygen (POz/FiO2) and positively correlated with the pulmonary vascular permeability index. Compared with the control group, the lung wet-to-dry weight ratio markedly increased and the histopathological findings obviously changed in the dichlorvos group, but only mildly increased and changed, respectively, in the atropine group. Conclusion The extravascular lung water index is an appropriate and valuable parameter for assessment of respiratory function in acute dichlorvos poisoning.展开更多
文摘Cardiac output(CO) is the volume of blood ejected by each ventricle per minute and is the product of stroke volume and heart rate. CO can thus be manipulated by alteration in heart rate or rhythm, preload, contractility and afterload. Moreover it gives important information about tissue perfusion and oxygen delivery. CO can be measured by various methods and thermodilution method using pulmonary artery catheter(PAC) is till date considered as gold standard method. Complications associated with PAC led to development of newer methods which are minimally or non-invasive. Newer methods fulfil other properties like continuous and reproducible reading, cost effective, reliable during various physiological states and have fast response time. These methods are validated against the gold standard with good level agreement. In this review we have discussed various newer methods of CO monitoring and their effectiveness in clinical use.
文摘Background Respiratory failure is the main cause of death in acute organophosphorus pesticide poisoning. In this study, a pulse-induced contour cardiac output monitor was used to evaluate the respiratory status in a pig model of acute dichlorvos poisoning. Methods Twenty female pigs were randomly allocated to dichlorvos (n=7), atropine (n=7), and control (n=6) groups. In the dichlorvos group, pigs were administered 80% emulsifiable dichlorvos (100 mg/kg) via a gastric tube. In the atropine group, pigs were similarly administered dichlorvos, and 0.5 hours later, atropine was injected to attain and maintain atropinization. The control group was administered saline solution. Arterial blood gas was measured at 0, 0.5, 1, 2, 4, and 6 hours post-injection. The extravascular lung water index and pulmonary vascular permeability index were recorded by the pulse-induced contour cardiac output monitor. At termination of the study, the animals were euthanized, the lung wet-to-dry weight ratio was determined, and histopathology was observed. Results In the dichlorvos group, the extravascular lung water index and pulmonary vascular permeability index were substantially increased from 0.5 hours and were particularly high within 1 hour. In the atropine group, these indices increased initially, but decreased from the 1-hour mark. The control group exhibited no obvious changes. In both the dichlorvos and atropine groups, the extravascular lung water index was negatively correlated with partial pressure of oxygen/fraction of inspiration oxygen (POz/FiO2) and positively correlated with the pulmonary vascular permeability index. Compared with the control group, the lung wet-to-dry weight ratio markedly increased and the histopathological findings obviously changed in the dichlorvos group, but only mildly increased and changed, respectively, in the atropine group. Conclusion The extravascular lung water index is an appropriate and valuable parameter for assessment of respiratory function in acute dichlorvos poisoning.