期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Determination of Vitamin B12 Using Differential Pulse Polarography
1
作者 Sukru Kalayci Ulku Unal Guler Somer 《American Journal of Analytical Chemistry》 2020年第5期187-196,共10页
Vitamin B12 is a type of vitamin also known by the name cobalamin. B12 is involved in many metabolism activities, including DNA synthesis, nervous system, red blood formation and immune system. Therefore, we chose the... Vitamin B12 is a type of vitamin also known by the name cobalamin. B12 is involved in many metabolism activities, including DNA synthesis, nervous system, red blood formation and immune system. Therefore, we chose the Differential Pulse Polarography (DPP) method is that has a high sensitivity for the determination of vitamin B12. This determination was possible with cobalt present in vitamin B12 structure. Since Co(III) is formed from the oxidation of the vitamin, its polarographic behavior had to be determined in various electrolytes such as acetate, borate, phosphate and ammonia. The polarograms of Co(III) were taken in these electrolytes in which 1.0 M NH3/ (pH = 9.8) and 1.0 M AcOH/AcO- (pH = 4.0) were found as the most suitable electrolytes. This method was successfully applied vitamin of B12 determination in a 1 mL ampoule with high precision. The LOD was found as 3.7 × 10-7 for instead of (S/N = 3). Besides Co(III), interference effects of Zn(II), Ni(II), Cr(III), Fe(III), Cu(II), Cd(II) and Se(IV) were also studied. It was found that only Zn(II) peak had an overlap Co(III) peak in ammonium buffer. This problem could be solved by working in 1.0 M AcOH/AcO- (pH = 4.0) buffer. B12, which is 1000 μg in 1 mL vitamin ampoule, was found for 4 measurements as 999 ± 15 μg as a result of 95% confidence interval. 展开更多
关键词 Vitamin B12 DETERMINATION COBALT Differential pulse polarography Interferences Studies
下载PDF
Determination of Consuming Rate for Pb-Ag-Ca Anode in Preparation of Electrolytic MnO_2 by Differential Pulse Polarography
2
作者 俞征 杨生恕 《Rare Metals》 SCIE EI CAS CSCD 1995年第2期144-149,共6页
The determination of trace element Pb in electrolyte MnSO_4H_2SO_4 was studied with differential pulse po-larography. The trace Pb was originated from new type Pb-Ag-Ca alloy anode being used in preduction processof e... The determination of trace element Pb in electrolyte MnSO_4H_2SO_4 was studied with differential pulse po-larography. The trace Pb was originated from new type Pb-Ag-Ca alloy anode being used in preduction processof electrolytic MnO_2 (EMD). The KCl was added as background of electrolyte. The differential pulse polarco-gram obtained for Pb(Ⅱ) is well in peak contour and is easy to determination. The peak potential is -0. 44 V(vs Ag-AgCl potential , experimental valuel). The Pb content may be determined by standard addition methodwhich is simple , reliable and fast. This study presents some foundamental data for Pb-Ag-Ca anode (abbreviated to PAC anede). The consuming rate for PAC anode is evaluated as 4. 82% annually. 展开更多
关键词 Electrolyte MnSO_4H_2SO_4 Trace lead Differential pulse polarography Pb-Ag-Ca anode Consuming rate
下载PDF
Study on the determination of trace rhenium(Ⅶ)by the adsorption differential pulse polarography
3
作者 Rolf Neeb 《Acta Chimica Sinica English Edition》 SCIE CAS CSCD 1989年第5期412-421,共1页
The determination of trace rhenium(Ⅶ)by differential pulse polarography in the system of H_2SO_4-(NH_2OH)_2·H_2SO_4-TeO_4^(2-) is markedly improved by the addition of Nitron,which is adsorbed on the surface of m... The determination of trace rhenium(Ⅶ)by differential pulse polarography in the system of H_2SO_4-(NH_2OH)_2·H_2SO_4-TeO_4^(2-) is markedly improved by the addition of Nitron,which is adsorbed on the surface of mercury electrode.The limit of detection is down to 2×10^(-10) M.The adsorptive peak potential is -0.80V(vs.SCE).In the ranges of 5×10^(-10)-10^(-8),1×10^(-8)-10^(-7) and 1× 10^(-7)-10^(-6)M,there are good linear relationships between the peak current increment and the concentration,of which the relative standard deviations are 9.5,6.6,1.8% respectively with the correlation coefficients of linear regression of 0.995—0.999.The results relating to this polarographic wave show that it is an adsorption-catalytic wave.The mechanism of the electrode reaction is dis- cussed. 展开更多
关键词 Study on the determination of trace rhenium by the adsorption differential pulse polarography
全文增补中
上一页 1 下一页 到第
使用帮助 返回顶部