期刊文献+
共找到2,897篇文章
< 1 2 145 >
每页显示 20 50 100
Improvement of circuit oscillation generated by underwater high voltage pulse discharges based on pulse power thyristor
1
作者 于营波 康忠健 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第3期150-160,共11页
High voltage fracturing technology was widely used in the field of reservoir reconstruction due to its advantages of being clean, pollution-free, and high-efficiency. However, high-frequency circuit oscillation occurs... High voltage fracturing technology was widely used in the field of reservoir reconstruction due to its advantages of being clean, pollution-free, and high-efficiency. However, high-frequency circuit oscillation occurs during the underwater high voltage pulse discharge process, which brings security risks to the stability of the pulse fracturing system. In order to solve this problem, an underwater pulse power discharge system was established, the circuit oscillation generation conditions were analyzed and the circuit oscillation suppression method was proposed. Firstly, the system structure was introduced and the charging model of the energy storage capacitor was established by the state space average method. Next, the electrode high-voltage breakdown model was established through COMSOL software, the electrode breakdown process was analyzed according to the electron density distribution image, and the plasma channel impedance was estimated based on the conductivity simulation results. Then the underwater pulse power discharge process and the circuit oscillation generation condition were analyzed, and the circuit oscillation suppression strategy of using the thyristor to replace the gas spark switch was proposed. Finally, laboratory experiments were carried out to verify the precision of the theoretical model and the suppression effect of circuit oscillation. The experimental results show that the voltage variation of the energy storage capacitor, the impedance change of the pulse power discharge process, and the equivalent circuit in each discharge stage were consistent with the theoretical model. The proposed oscillation suppression strategy cannot only prevent the damage caused by circuit oscillation but also reduce the damping oscillation time by77.1%, which can greatly improve the stability of the system. This research has potential application value in the field of underwater pulse power discharge for reservoir reconstruction. 展开更多
关键词 underwater high voltage pulse discharge circuit oscillation suppression state space average method pulse power thyristor
下载PDF
A Pulse Width Modulation Scheme With Zero-sequence Voltage Injection for Single Phase Three-level NPC Rectifiers 被引量:9
2
作者 宋文胜 冯晓云 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0003-I0003,共1页
直流侧中点电位电压偏移是多电平中性点钳位型变流器的主要缺点。以单相三电平NPC整流器为研究对象,以实现直流侧中点电位无漂移为控制目标,以传统的单相三电平单极性载波脉宽调制方法为基础,首先提出一种基于零序电压分量注入的载... 直流侧中点电位电压偏移是多电平中性点钳位型变流器的主要缺点。以单相三电平NPC整流器为研究对象,以实现直流侧中点电位无漂移为控制目标,以传统的单相三电平单极性载波脉宽调制方法为基础,首先提出一种基于零序电压分量注入的载波脉宽调制算法;然后在此基础上给出基于零序电压分量极限值注入的载波脉宽调制算法;并给出这2种方法的零序电压分量的设计方案;最后,对这2种方法进行了详细的理论分析、计算机仿真和1kW样机实验对比验证。研究结果表明:所提出的2种算法都能有效实现直流侧中点电位平衡控制,其中基于零序电压分量极限值注入的载波调制算法的中点电位控制具有更快动态响应速度,且其网侧电流的高次谐波主要分布在开关频率附近;而基于零序电压分量注入的载波调制算法的网侧电流高次谐波主要分布在2倍开关频率附近。但是在一个调制信号周期内,基于零序电压分量极限值注入的载波调制算法的开关切换次数比基于零序电压分量注入的载波调制算法低25%左右。 展开更多
关键词 三电平 脉冲宽度 零序电压 单相 整流器 中性点电压 调制 直流母线
下载PDF
THE EFFECTS OF PULSE BIAS VOLTAGE AND N_2 PARTIAL PRESSURE ON TiAlN FILMS OF ARC ION PLATING (AIP) 被引量:4
3
作者 M.S. Li, S.L. Zhu, Fuhui Wang, C. Sun and L.S. Wen (Institute of Metal Research, The Chinese Academy of Sciences, Shenyang l10016, China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2001年第6期520-524,共5页
Owing to the characteristics of arc ion plating(AIP) technique, the structure and composition of TiAlN films can be tailored by controlling of various parameters such as compositions of target materials, N2 partial pr... Owing to the characteristics of arc ion plating(AIP) technique, the structure and composition of TiAlN films can be tailored by controlling of various parameters such as compositions of target materials, N2 partial pressure, substrate bias and so on. In this study, several titanium aluminum nitride films were deposited on 1Cr11Ni2W2MoV steel for compressor blade of areo-engine under different d.c pulse bias voltage and nitrogen partial pressure. The effects of substrate pulse bias and nitrogen partial pressure on the deposition rate, droplet formation, microstruture and elemental component of the films were investigated. 展开更多
关键词 TiAlN film pulse bias voltage nitrogen partial pressure arc ion plating
下载PDF
Study on Evaluation Method of Aluminum alloy Pulse MIG Welding Stability Based on Arc Voltage Probability Density 被引量:5
4
作者 Jing Nie Xiao-Feng Meng Yu Shi 《Journal of Signal and Information Processing》 2011年第3期159-164,共6页
Bring forward a new analytical method in order to evaluate the stability of the process of aluminum alloy pulsed MIG welding. The ratio of the first and the second peak in arc voltage signal probability density was se... Bring forward a new analytical method in order to evaluate the stability of the process of aluminum alloy pulsed MIG welding. The ratio of the first and the second peak in arc voltage signal probability density was selected to evaluate aluminum alloy pulse MIG welding stability. By calculating the arc voltage signal probability density from 80 sets of welding experiments, the ratio of the two peaks in arc voltage probability in every set was captured. And the evaluation system of aluminum alloy pulse MIG welding stability was established. The smaller the ratio of peaks in arc voltage signal probability density is, the better the stability of the welding will be;the bigger the ratio of peaks in arc voltage signal probability density is, the poorer the stability of the welding will be. 展开更多
关键词 Aluminum Alloy pulse MIG Welding STABILITY Probability-Density ARC voltage
下载PDF
A Novel Square-wave Pulse Rotation Modulation Strategy for Modular Multilevel Converters 被引量:9
5
作者 YANG Xiaofeng LIN Zhiqin ZHENG Trillion Q YOU Xiaojie 《中国电机工程学报》 EI CSCD 北大核心 2013年第9期I0006-I0006,共1页
悬浮直流电容电压的均衡问题是模块组合多电平变换器(modular multilevel converter,MMC)的关键问题之一。提出一种可实现MMC直流电容电压平衡的方波脉冲循环调制(square-wave pulse rotation modulation,SWPRM)策略,在保证合成的... 悬浮直流电容电压的均衡问题是模块组合多电平变换器(modular multilevel converter,MMC)的关键问题之一。提出一种可实现MMC直流电容电压平衡的方波脉冲循环调制(square-wave pulse rotation modulation,SWPRM)策略,在保证合成的阶梯波输出波形不变的前提下,根据MMC的拓扑结构和工作原理,对传统方波脉冲列进行脉冲优化,并按照一定的次序和切换周期进行循环和判断反相调整,获得的循环方波脉冲列作为最终驱动脉冲用于实现对MMC的控制。实验结果表明,采用提出的方波脉冲循环调制策略无需任何电容电压控制措施,在较低开关频率下,实现了MMC各功率单元间有功能量的平均分配和直流电容电压的均衡。 展开更多
关键词 调制策略 方波脉冲 多电平变流器 模块化 旋转 直流电容器 多电平变换器 平衡控制
下载PDF
Numerical simulation of high voltage electric pulse comminution of phosphate ore 被引量:4
6
作者 Razavian Seyed Mohammad Rezai Bahram +1 位作者 Irannajad Mehdi Ravanji Mohammad Hasan 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第3期473-478,共6页
Numerical simulation of the electrical field distribution helps in-depth understanding of the mechanisms behind the responses and the benefits of the high voltage pulse comminution. The COMSOL Multiphysics package was... Numerical simulation of the electrical field distribution helps in-depth understanding of the mechanisms behind the responses and the benefits of the high voltage pulse comminution. The COMSOL Multiphysics package was used to numerically simulate the effect of ore compositions in this study. Regarding phosphate ore particles shape and composition, the effects of mineral composition, particle size, particle shape and electrodes distance were investigated on the electrical field intensity and distribution. The results show that the induced electrical field is significantly dependent on the electrical properties of minerals,the feed particle size and the location of conductive minerals in ores. The angle of material contact surface with the discharge electrode is also an important factor in the intensity of electrical field. Moreover,it is found that the specific liberation effect at the disintegration of phosphate ore by electrical pulses is due to the locality of the electrical field at the interface of mineral components of the phosphate ore aggregates with different permittivities. However, the intensity of the electrical field increases with sharpening the contact angle. Besides, the electrical discharge in the samples is converted to the electrohydraulic discharge across the surrounding water by changing the distance between the discharge electrode and sample surface. 展开更多
关键词 高压电脉冲 磷酸盐矿 数值模拟 粉碎 放电电极 电场分布 矿物成分 电场强度
下载PDF
Effects of High-voltage Pulse Electric Field Treatment on the Structure Stability of Konjac Glucomannan 被引量:3
7
作者 姚闽娜 范琳琳 +4 位作者 刘雅楠 陈清爱 曾援 简文杰 庞杰 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2011年第12期1833-1837,共5页
Structures of KGM treated in two high-voltage pulse electric fields were characterized by infrared spectroscopy,Raman spectroscopy,X-ray diffraction and so on.The results showed that intermolecular hydrogen bonding in... Structures of KGM treated in two high-voltage pulse electric fields were characterized by infrared spectroscopy,Raman spectroscopy,X-ray diffraction and so on.The results showed that intermolecular hydrogen bonding interactions of KGM were reduced after being treated with high-voltage pulse electric field,but there was no significant effect on its fiber chain form and thermal characteristics.Results of the study can provide a useful reference for further study on the structure and property of KGM,and especially can provide theoretical basis for the effect of physical field on the foodstuff deep processing related to KGM. 展开更多
关键词 KGM structural characterization high-voltage pulse electric field STABILITY
下载PDF
Removal of Volatile Organic Compounds (VOCs) Mixture by Multi-Pin-Mesh Corona Discharge Combined with Pulsed High-Voltage 被引量:4
8
作者 张玥 李锻 王洪昌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第6期702-707,共6页
Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate ... Removal of single component and binary mixtures of benzene and m-xylene using a multi-pin-mesh reactor was studied to find the decomposition characteristics, carbon balance and CO2 selectivity. The decomposition rate of benzene in mixture was approximately 16% lower than that of single component benzene. However, the decomposition rate of m-xylene in mixture was slightly higher than that of single component m-xylene. Carbon balance of the mixture decomposition process achieved a lower level than that of single component benzene/m-xylene. Increase in the specific input energy was helpful to improve CO2 selectivity in the single component decomposition process, while the specific input energy had a negligible effect on CO2 selectivity in the mixture decomposition process. By changing the oxygen content in background gas, we found that different types of radicals showed different reaction activities toward benzene and m-xylene. Benzene was more likely to react with nitrogen-containing radicals, while m-xylene was more likely to react with oxygen-containing radicals. 展开更多
关键词 multi-pin-mesh corona discharge pulsed high-voltage mixed VOCs
下载PDF
Nonlinear Response Analysis for Insulation Diagnosis of Water-tree Aged 10 kV XLPE Cable Using Pulse Voltage 被引量:3
9
作者 DU Boxue WANG Li 《高电压技术》 EI CAS CSCD 北大核心 2013年第8期1852-1857,共6页
The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged ... The diagnosis of water trees of cable insulation is of great importance as the water-treeing is a primary cause of aging breakdown for the middle voltage cables. In this paper, it is described how the water-tree-aged 10 kV XLPE cables were diagnosed. The cables were subjected to electrical stress of 5.9 kV/mm and a thermal load cycle in a curved water-filled tube for 3, 6 and 12 months of aging in accor- dance with the accelerated water-tree test method. The aged cables were used as the samples for water-tree diagnosis. First, the water-tree degraded cable, was charged by a DC voltage, and then the cable was grounded while a pulse voltage was applied to it for releasing the space charge trapped in the water trees. The amount of the space charge, which corresponds to the deterioration degree of the water trees, was calculated. The effects of DC voltage amplitude, pulse voltage repetition rate and aging conditions on the amount of the space charge were studied. Obtained results show that the amount of the space charge has a positive correlation with the applied DC voltage and the ag- ing time of the cables, and that a peak value of space charge appears with the increase of the pulse voltage repetition rate. An optimum pulse voltage repetition rate under which the space charge can be released rapidly is obtained. Furthermore, the releasing mechanism of space charge by the pulse voltage is discussed. Accumulated results show that the presented method has a high resolution for the diagnosis of water tree degradation degree and is expected to be applied in practice in future. 展开更多
关键词 交联聚乙烯电缆 脉冲电压 绝缘诊断 非线性响应 水树 交联聚乙烯绝缘电缆 空间电荷 电缆老化
下载PDF
Removal of phenol by activated alumina bed in pulsed high-voltage electric field 被引量:7
10
作者 ZHU Li-nan MA Jun YANG Shi-dong 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第4期409-415,共7页
A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results... A new process for removing the pollutants in aqueous solution-activated alumina bed in pulsed high-voltage electric field was investigated for the removal of phenol under different conditions. The experimental results indicated the increase in removal rate with increasing applied voltage, increasing pH value of the solution, aeration, and adding Fe^2+. The removal rate of phenol could reach 72.1% when air aeration flow rate was 1200 ml/min, and 88.2% when 0.05 mmol/L Fe^2+ was added into the solution under the conditions of applied voltage 25 kV, initial phenol concentration of 5 mg/L, and initial pH value 5.5. The addition of sodium carbonate reduced the phenol removal rate. In the pulsed high-voltage electric field, local discharge occurred at the surface of activated alumina, which promoted phenol degradation in the thin water film. At the same time, the space-time distribution of gas-liquid phases was more uniform and the contact areas of the activated species generated from the discharge and the pollutant molecules were much wider due to the effect of the activated alumina bed. The synthetical effects of the pulsed high-voltage electric field and the activated alumina particles accelerated phenol degradation. 展开更多
关键词 pulsed high-voltage electric field hybrid gas-liquid electrical discharge activated alumina PHENOL Fenton's reaction water treatment
下载PDF
The Influence of Electrode Surface Mercury Film Deformation on the Breakdown Voltage of a Sub-Nanosecond Pulse Discharge Tube
11
作者 翁明 徐伟军 王瑞 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第11期1024-1029,共6页
A sub-nanosecond pulse discharge tube is a gas discharge tube which can generate a rapid high-voltage pulse of kilo-volts in amplitude and sub-nanoseconds in width. In this paper, the sub-nanosecond pulse discharge tu... A sub-nanosecond pulse discharge tube is a gas discharge tube which can generate a rapid high-voltage pulse of kilo-volts in amplitude and sub-nanoseconds in width. In this paper, the sub-nanosecond pulse discharge tube and its working principles are described. Because of the phenomenon that the deformation process of the mercury film on the electrode surface lags behind the charging process, the mercury film deformation process affects the dynamic breakdown voltage of the tube directly. The deformation of the mercury film is observed microscopically, and the dynamic breakdown voltage of the tube is messured using an oscillograph. The results show that all the parameters in the charging process, such as charging resistance, charging capacitance and DC power supply, affect the dynamic breakdown voltage of the tube. Based on these studies, the output pulse amplitude can be controlled continuously and individually by adjusting the power supply voltage. When the DC power supply is adjusted from 7 kV to 10 kV, the dynamic breakdown voltage ranges from 6.5 kV to 10 kV. According to our research, a kind of sub-nanosecond pulse generator is made, with a pulse width ranging from 0.5 ns to 2.5 ns, a rise time from 0.32 ns to 0.58 ns, and a pulse amplitude that is adjustable from 1.5 kV to 5 kV. 展开更多
关键词 sub-nanosecond pulse generator mercury film deformation gas discharge breakdown voltage pulse parameter
下载PDF
Correction factor based double model fuzzy logic control strategy of arc voltage in pulsed MIG welding
12
作者 吴开源 黄石生 蒙永民 《China Welding》 EI CAS 2005年第1期63-67,共5页
According to the feature of arc voltage control in welding steel using pulsed MIG welding, a correction factor based double model fuzzy logic controller (FLC) was developed to realize the arc voltage control by means ... According to the feature of arc voltage control in welding steel using pulsed MIG welding, a correction factor based double model fuzzy logic controller (FLC) was developed to realize the arc voltage control by means of arc voltage feedback. When the error of peak arc voltage was great, a coarse adjusting fuzzy logic control rules with correction factor was designed, in the controller, the peak arc voltage was controlled by the wire feeding speed by means of arc voltage feedback. When the error of peak arc voltage was small, a fine adjusting fuzzy logic control rules with correction factor was designed, in this controller, the peak arc voltage was controlled by the background time by means of arc voltage feedback. The FLC was realized in a Look-Up Table (LUT) method. Experiments had been carried out aiming at implementing the control strategy to control the arc length change in welding process. Experimental results show that the controller proposed enables the consistency of arc length and the stability of arc voltage and welding process to be achieved in pulsed MIG welding process. 展开更多
关键词 pulsed MIG welding arc voltage adjustment fuzzy logic control
下载PDF
Fabrication of Micro Structures by Ultrashort Voltage Pulse Electrical Discharge Machining
13
作者 Chenxue Wang Weiyu He Yan Xiao 《Journal of Minerals and Materials Characterization and Engineering》 2018年第2期235-243,共9页
The machining of small holes and array holes has been a difficult problem in machining field. Tiny hole is widely used in mechanical field, for instance, fuel injection nozzles, spinneret holes for synthetic fibers an... The machining of small holes and array holes has been a difficult problem in machining field. Tiny hole is widely used in mechanical field, for instance, fuel injection nozzles, spinneret holes for synthetic fibers and wire drawing dies. This paper investigated the application of EDM (electrical discharge machining) to the fabrication of micro structures. There are obvious limitations in the process of micro-electrical discharge machining, such as electrode wear, unstable discharge condition and low machining efficiency. The effects of EDM parameters were investigated, such as voltage, pulse frequency, and frequency of ultrasonic vibration applied to electrode. Micro holes were machined with Pt electrode made by focused-ion-beam chemical vapor deposition (FIB-CVD) and Cu electrode made by wire-electrode cutting. The comparison experiments between EDM and ECM (electrochemical machining) indicated that the processing of ECM has serious stray current corrosion and poor machining precision. Moreover, the workpiece vibration was firstly proposed to be utilized in the micro-electrical discharge machining. It can be concluded that maximum machine could be obtained under the amplitude ratio of 76%, which was an appropriate parameter. 展开更多
关键词 MICRO-EDM (Electrical DISCHARGE Machining) Micro-Holes ULTRASHORT voltage pulse
下载PDF
High-voltage Nanosecond Pulse Generators of the "PROTEUS" Line for Discharge with Runaway Electrons Applications
14
作者 Anatoly N. Maltsev Maxim V. Martynov +3 位作者 Alexey V. Mikov Viktor G. Podkovyrov Leonid L. Zhukov Alexander Yu. Ivanov 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2506-2513,共8页
关键词 PROTEUS 纳秒脉冲发生器 电子应用 气体放电 高压 失控 输出电压 脉冲重复频率
下载PDF
Photographic Study on Spark Discharge Generated by a Nanosecond High-Voltage Pulse over a Water Surface
15
作者 李文琴 温小琼 张家良 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第10期1020-1024,共5页
Spark discharge generated by a nanosecond positive high-voltage pulse over a water surface at atmospheric pressure in air was studied using a high speed camera system. Faint streamers form near the pin electrode and p... Spark discharge generated by a nanosecond positive high-voltage pulse over a water surface at atmospheric pressure in air was studied using a high speed camera system. Faint streamers form near the pin electrode and propagate towards the water surface. The time for the streamer propagating across the air gap was estimated to be about 50 ns to 60 ns with a propagation velocity of ~1.3 × 10^5 m/s. It was found that the water conductivity and the gap distance have no significant effect on the propagation velocity of the streamer. After the streamers touch the water surface a brilliant spark channel forms across the air gap. The maximum diameter at the middle of the spark channel is about 1 mm, and approximately contracts with a radical velocity of about 2.0× 10^3 m/s. No significant dependence of the maximum diameter and decay velocity of the spark channel on the water conductivity and the gap distance were recognized in the present work. The maximum conduction current for a gap distance of 5 mm is significantly larger than that for a gap distance of 10 mm at the same water conductivity, and shows an increasing tendency with increasing water conductivity for a fixed gap distance. Based on the maximum conduction current, the effect of water conductivity and gap distance on the electron density of the spark discharge plasma at the peak current was investigated. Within the range studied, the electron density in the spark channel is about 10^15 cm^-3 and increases with water conductivity at a fixed gap distance. 展开更多
关键词 spark discharge water surface nanosecond high-voltage pulse high speedphotography
下载PDF
Characteristics of fulvic acid by high voltage pulse discharge plasma
16
作者 ZHANG Sheng-hua ZHANG Kui WU Chun-du 《Journal of Chemistry and Chemical Engineering》 2009年第1期13-17,60,共6页
关键词 脉冲放电等离子体 高压脉冲电场 黄腐酸 氧化还原电位 TOC去除率 高电压脉冲 特性 等离子体处理
下载PDF
Oxidation of S(Ⅳ)in Seawater by Pulsed High Voltage Discharge Plasma with TiO_2/Ti Electrode as Catalyst~
17
作者 巩建英 张兴旺 +1 位作者 王小平 雷乐成 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第12期1209-1214,共6页
Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) sys- tem is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation proces... Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) sys- tem is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation process combined with a TiO2 photocatalyst to convert S(IV) to S(VI) in artificial seawater. Experimental results show that the oxidation of S(IV) in artificial seawater is enhanced in the pulsed discharge plasma process through the application of TiO2 coating electrodes. The oxidation rate of S(IV) using Ti metal as a ground electrode is about 2.0x10-4 mol. L 1. min-1, the oxidation rate using TiO2/Ti electrode prepared by annealing at 500 ~C in air is 4.5x 10-4 tool. L-a ~ min-1, an increase with a factor 2.25. The annealing temper- ature for preparing TiO2/Ti electrode has a strong effect on the oxidation of S(IV) in artificial seawater. The results of in-situ emission spectroscopic analysis show that chemically active species (i.e. hydroxyl radicals and oxygen radicals) are produced in the pulsed discharge plasma process. Compared with the traditional air oxidation process and the sole plasma-induced oxidation process, the combined application of TiO2 photocatalysts and a pulsed high-voltage electrical discharge process is useful in enhancing the energy and conversion efficiency of S(IV) for the seawater FGD system. 展开更多
关键词 pulsed high-voltage electrical discharge titanium dioxide energy efficiency oxidative species sulfite oxidation
下载PDF
Effects of the Liquid Conductivity on Pulsed High-voltage Discharge Modes in Water
18
作者 BinYANG LeChengLEI MingHuaZHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2004年第10期1215-1218,共4页
关键词 pulsed high-voltage discharge spark discharge corona discharge quantum yields.
下载PDF
Verification of Drainage Sterilization System Uses Low-Voltage Pulsed Electric Field in a Prawn Farm
19
作者 Hirotaka Naitou Yukinori Tani Shingo Nishi 《Journal of Agricultural Science and Technology(A)》 2014年第3期189-196,共8页
关键词 系统验证 脉冲电场 低电压 虾场 灭菌 排水 白斑综合症病毒 WSSV感染
下载PDF
The Design of TZ-2 High Voltage Pulse Modulator
20
作者 WANG Mingwei KANG Zihua LI Xiujuan ZHENG Tieliu WANG Xuehua LI Bo FENG Kun 《Southwestern Institute of Physics Annual Report》 2005年第1期69-70,共2页
关键词 高压脉冲 调制器 辅助加热 电子回旋加速器
下载PDF
上一页 1 2 145 下一页 到第
使用帮助 返回顶部