期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Enhanced resistance switching stability of transparent ITO/TiO_2/ITO sandwiches 被引量:1
1
作者 孟洋 张培健 +5 位作者 刘紫玉 廖昭亮 潘新宇 梁学锦 赵宏武 陈东敏 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第3期503-507,共5页
We report that fully transparent resistive random access memory (TRRAM) devices based on ITO/TiO2/ITO sandwich structure, which are prepared by the method of RF magnetron sputtering, exhibit excellent switching stab... We report that fully transparent resistive random access memory (TRRAM) devices based on ITO/TiO2/ITO sandwich structure, which are prepared by the method of RF magnetron sputtering, exhibit excellent switching stability. In the visible region (400 800 nm in wavelength) the TRRAM device has a transmittance of more than 80%. The fabricated TRRAM device shows a bipolar resistance switching behaviour at low voltage, while the retention test and rewrite cycles of more than 300,000 indicate the enhancement of switching capability. The mechanism of resistance switching is further explained by the forming and rupture processes of the filament in the TiO2 layer with the help of more oxygen vacancies which are provided by the transparent ITO electrodes. 展开更多
关键词 colossal electroresistance effect electrical pulse induced resistance switching (EPIR) transparent resistance random access memory (TRRAM)
下载PDF
A pulsed switching peroxi-coagulation process to control hydroxyl radical production and to enhance 2,4-Dichlorophenoxyacetic acid degradation 被引量:3
2
作者 Yaobin Lu Songli He +5 位作者 Dantong Wang Siyuan Luo Aiping Liu Haiping Luo Guangli Liu Renduo Zhang 《Frontiers of Environmental Science & Engineering》 SCIE EI CSCD 2018年第5期86-90,共5页
The aim of this study was to develop a new pulsed switching peroxi-coagulation system to control hydroxyl radical(∙OH)production and to enhance 2,4-Dichlorophenoxyacetic acid(2,4-D)degradation.The system was construct... The aim of this study was to develop a new pulsed switching peroxi-coagulation system to control hydroxyl radical(∙OH)production and to enhance 2,4-Dichlorophenoxyacetic acid(2,4-D)degradation.The system was constructed with a sacrifice iron anode,a Pt anode,and a gas diffusion cathode.Production of H_(2)O_(2) and Fe^(2+)was controlled separately by time delayers with different pulsed switching frequencies.Under current densities of 5.0 mA/cm^(2)(H_(2)O_(2))and 0.5 mA/cm^(2)(Fe^(2+)),the∙OH production was optimized with the pulsed switching frequency of 1.0 s(H_(2)O_(2)):0.3 s(Fe^(2+))and the ratio of H_(2)O_(2) to Fe^(2+)molar concentrations of 6.6.Under the optimal condition,2,4-D with an initial concentration of 500 mg/L was completely removed in the system within 240 min.The energy consumption for the 2,4-D removal in the system was much lower than that in the electro-Fenton process(686 vs.13610 kWh/kg TOC).The iron consumption in the system was~20 times as low as that in the peroxi-coagulation process(19620 vs.3940400 mg/L)within 240 min.The system should be a promising peroxi-coagulation method for organic pollutants removal in wastewater. 展开更多
关键词 pulsed switching peroxi-coagulation system Energy consumption Hydroxyl radical production 2 4-Dichlorophenoxyacetic acid
原文传递
Three-dimension micro magnetic detector based on GMI effect
3
作者 魏双成 邓甲昊 +1 位作者 韩超 杨雨迎 《Journal of Beijing Institute of Technology》 EI CAS 2014年第2期143-146,共4页
The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to pro... The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction. 展开更多
关键词 giant magneto-impedance(GMI)effect amorphous wire three dimension detector pulse generator analog switch
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部