期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
The effect of pulse voltage rise rate on the polypropylene surface hydrophilic modification by ns pulsed nitrogen DBD
1
作者 刘峰 李舒豪 +3 位作者 赵昱雷 Shakeel AKRAM 张丽 方志 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第10期6-14,共9页
The nanosecond(ns) pulsed nitrogen dielectric barrier discharge(DBD) is employed to enhance the hydrophilicity of polypropylene(PP) surface and improve its application effect.The discharge characteristics of the ns pu... The nanosecond(ns) pulsed nitrogen dielectric barrier discharge(DBD) is employed to enhance the hydrophilicity of polypropylene(PP) surface and improve its application effect.The discharge characteristics of the ns pulsed nitrogen DBD with different pulse rise times(from 50to 500 ns) are investigated by electrical and optical diagnostic methods and the discharge uniformity is quantitatively analyzed by image processing method.To characterize the surface hydrophilicity,the water contact angle(WCA) is measured,and the physical morphology and chemical composition of PP before and after modification are analyzed to explore the effect of plasma on PP surface.It is found that with increasing pulse rise time from 50 to 500 ns,DBD uniformity becomes worse,energy efficiency decreases from 20% to 10.8%,and electron density decrease from 6.6 × 10^(11)to 5.5 × 10^(11)cm^(-3).The tendency of electron temperature is characterized with the intensity ratio of N_(2)/N_(2)^(+)emission spectrum,which decreases from 17.4 to15.9 indicating the decreasing of T_(e) with increasing pulse rise time from 50 to 500 ns.The PP surface treated with 50 ns pulse rise time DBD has a lower WCA(~47°),while the WCA of PP treated with 100 to 500 ns pulse rise time DBD expands gradually(~50°–57°).According to the study of the fixed-point WCA values,the DBD-treated PP surface has superior uniformity under50 ns pulse rise time(3° variation) than under 300 ns pulse rise time(8° variation).After DBD treatment,the increased surface roughness from 2.0 to 9.8 nm and hydrophilic oxygencontaining groups on the surface,i.e.hydroxyl(-OH) and carbonyl(C=O) have played the significant role to improve the sample’s surface hydrophilicity.The short pulse voltage rise time enhances the reduced electric field strength(E/n) in the discharge space and improves the discharge uniformity,which makes relatively sufficient physical and chemical reactions have taken place on the PP surface,resulting in better treatment uniformity. 展开更多
关键词 dielectric barrier discharge pulse rise time material surface modification POLYPROPYLENE UNIFORMITY
下载PDF
Mechanism of Magnetic Pulse Wave Signal for Blood Pressure Measurement
2
作者 Yang Zhang Yibin Li +1 位作者 Xiaomeng Chen Ning Deng 《Journal of Biomedical Science and Engineering》 2016年第10期29-36,共9页
Continuous non-invasive blood pressure (BP) measurement can be realized by using pulse transit time (PTT) based on electrocardiogram (ECG) and pulse wave signal. Modulated magnetic signature of blood (MMSB) is a promi... Continuous non-invasive blood pressure (BP) measurement can be realized by using pulse transit time (PTT) based on electrocardiogram (ECG) and pulse wave signal. Modulated magnetic signature of blood (MMSB) is a promising approach to obtain PTT. The origin of MMSB is critical to establish the relationship between MMSB and BP. In this paper, two possible origins of MMSB, blood disturbance mechanism and angular variation mechanism, are analyzed and verified through three control experi-ments under different conditions. The influence of blood velocity alteration and blood volume alteration on magnetic field is investigated though blood flow simulation sys-tem. It is found that MMSB comes mainly from the periodic blood flow while the per-turbation caused by angular variation between sensitive axis of the magnetic sensor and geomagnetic field can be neglected. As to blood disturbance mechanism, the change of blood volume plays a decisive role while the effect of blood velocity altera-tion is negligible. 展开更多
关键词 Blood Pressure (BP) Modulated Magnetic Signature of Blood (MMSB) pulse Transit time (PTT)
下载PDF
Machine Learning for Detecting Blood Transfusion Needs Using Biosignals
3
作者 Hoon Ko Chul Park +3 位作者 Wu Seong Kang Yunyoung Nam Dukyong Yoon Jinseok Lee 《Computer Systems Science & Engineering》 SCIE EI 2023年第8期2369-2381,共13页
Adequate oxygen in red blood cells carrying through the body to the heart and brain is important to maintain life.For those patients requiring blood,blood transfusion is a common procedure in which donated blood or bl... Adequate oxygen in red blood cells carrying through the body to the heart and brain is important to maintain life.For those patients requiring blood,blood transfusion is a common procedure in which donated blood or blood components are given through an intravenous line.However,detecting the need for blood transfusion is time-consuming and sometimes not easily diagnosed,such as internal bleeding.This study considered physiological signals such as electrocardiogram(ECG),photoplethysmogram(PPG),blood pressure,oxygen saturation(SpO2),and respiration,and proposed the machine learning model to detect the need for blood transfusion accurately.For the model,this study extracted 14 features from the physiological signals and used an ensemble approach combining extreme gradient boosting and random forest.The model was evaluated by a stratified five-fold crossvalidation:the detection accuracy and area under the receiver operating characteristics were 92.7%and 0.977,respectively. 展开更多
关键词 Blood transfusion ECG PPG pulse transit time blood pressure machine learning
下载PDF
SNR improvement in self-heterodyne detection Brillouin optical time domain reflectometer using Golay pulse codes 被引量:5
4
作者 李永倩 李晓娟 +2 位作者 范寒柏 安琪 张立欣 《Optoelectronics Letters》 EI 2017年第6期414-418,共5页
The application of Golay pulse coding technique in spontaneous Brillouin-based distributed temperature sensor based on self-heterodyne detection of Rayleigh and Brillouin scattering is theoretically and experimentally... The application of Golay pulse coding technique in spontaneous Brillouin-based distributed temperature sensor based on self-heterodyne detection of Rayleigh and Brillouin scattering is theoretically and experimentally analyzed. The enhancement of system signal to noise ratio(SNR) and reduction of temperature measurement error provided by coding are characterized. By using 16-bit Golay coding, SNR can be improved by about 2.77 d B, and temperature measurement error of the 100 m heated fiber is reduced from 1.4 °C to 0.5 °C with a spatial resolution of 13 m. The results are believed to be beneficial for the performance improvement of self-heterodyne detection Brillouin optical time domain reflectometer. 展开更多
关键词 SNR improvement in self-heterodyne detection Brillouin optical time domain reflectometer using Golay pulse codes BOTDR
原文传递
Non-Contact Blood Pressure Measurement Based on IPPG
5
作者 Jiancheng Zou Shouyu Zhou +1 位作者 Bailin Ge Xin Yang 《Journal of New Media》 2021年第2期41-51,共11页
Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding o... Blood pressure is an important physiological parameter to reflect human vital signs.In order to achieve the non-contact dynamic blood pressure acquisition based on ordinary optical camera,a theoretical understanding of the functional relationship between blood pressure and pulse wave signal conduction time.And through imaging photoelectric plethysmography(IPPG),pulse wave signal conduction time of forehead and hand was obtained with ordinary optical camera.First,the pulse wave conduction time was obtained by recording the video with an ordinary optical camera.Second,real-time blood pressure values were collected.Finally,based on the relationship between blood pressure and pulse wave conduction time,a non-contact blood pressure measurement prediction model was obtained through neural network fitting.So that non-contact blood pressure measurement with optical camera could be completed.The method in this paper has several advantages,such as low requirements on measuring equipment,low cost,and simple operation.It can let people get rid of the discomfort caused by measuring equipment such as cuff and can measure blood pressure at any time.The predicted blood pressure results were compared with an Omron wrist electronic sphygmomanometer.The calculated error of systolic blood pressure is-9.28%~3.16%,and the error of diastolic blood pressure is-9.84~4.35%. 展开更多
关键词 Non contact blood pressure measurement imaging photoelectric plethysmography(IPPG) pulse wave conduction time
下载PDF
Research and implementation of 100 A pulsed current source pulse edge compression 被引量:4
6
作者 Tian Xiaojian Zhang Dapeng +1 位作者 Mudare Joseph Gao Fubin 《The Journal of China Universities of Posts and Telecommunications》 EI CSCD 2016年第2期73-78,共6页
In order to increase the usefulness of pulsed current source in engineering practice, research and study was carried out on how to increase the pulse current amplitude, reduce the rise /fall time of output pulse and M... In order to increase the usefulness of pulsed current source in engineering practice, research and study was carried out on how to increase the pulse current amplitude, reduce the rise /fall time of output pulse and MOSFET switching losses, etc. Through the analysis of the pulsed current source works theory and the mathematical derivation of the circuit model, the deduction and calculation of the pulse edge compression control methods, and improve the overall circuit structure and optimize the manufacturing process according to the theory. The following indicators was realized: the output pulse current amplitude can be up to 100 A, the shortest pulse rise / fall time was 18.8 ns and 16.1 ns respectively when the maximum amplitude output, the pulse width could be narrowest to 40 ns, repetition frequency could achieve 10 Hz to 10 k Hz, MOSFET switching losses decreased by 30.9 %. This pulsed current source can be used, not only as the power supply for the ordinary high speed narrow pulse width laser diode, but also as an ideal drive power for the high energy, narrow width pulse laser diode. 展开更多
关键词 optoelectronics high-power narrow-width pulse driver 100 A pulse current short rise/fall time
原文传递
Review of X-ray pulsar spacecraft autonomous navigation 被引量:1
7
作者 Yidi WANG Wei ZHENG +7 位作者 Shuangnan ZHANG Minyu GE Liansheng LI Kun JIANG Xiaoqian CHEN Xiang ZHANG Shijie ZHENG Fangjun LU 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2023年第10期44-63,共20页
This article provides a review on X-ray pulsar-based navigation(XNAV).The review starts with the basic concept of XNAV,and briefly introduces the past,present and future projects concerning XNAV.This paper focuses on ... This article provides a review on X-ray pulsar-based navigation(XNAV).The review starts with the basic concept of XNAV,and briefly introduces the past,present and future projects concerning XNAV.This paper focuses on the advances of the key techniques supporting XNAV,including the navigation pulsar database,the X-ray detection system,and the pulse time of arrival estimation.Moreover,the methods to improve the estimation performance of XNAV are reviewed.Finally,some remarks on the future development of XNAV are provided. 展开更多
关键词 Estimation of pulse time of arrival Spacecraft autonomous navigation X-ray detection X-ray pulsar-based navigation X-ray pulsar signal processing
原文传递
衬底对单脉冲激光烧蚀下环境密度恢复时间的影响
8
作者 邓泽超 褚立志 +4 位作者 丁学成 李艳丽 梁伟华 傅广生 王英龙 《中国激光》 EI CAS CSCD 北大核心 2009年第11期3045-3049,共5页
假定烧蚀粒子与环境气体原子均为刚性硬球,采用蒙特卡罗(Monte Carlo)方法,对单脉冲激光烧蚀产生的硅(Si)粒子在1000Pa环境氦(He)气中的传输过程进行了数值模拟,研究了衬底对环境密度恢复时间的影响。结果发现,衬底对粒子完全反弹和完... 假定烧蚀粒子与环境气体原子均为刚性硬球,采用蒙特卡罗(Monte Carlo)方法,对单脉冲激光烧蚀产生的硅(Si)粒子在1000Pa环境氦(He)气中的传输过程进行了数值模拟,研究了衬底对环境密度恢复时间的影响。结果发现,衬底对粒子完全反弹和完全吸附的情况下对应的环境密度恢复时间分别为1713.2μs和1663.2μs,并且随着衬底对粒子临界吸附速度的增大,环境密度恢复时间先增大后减小。 展开更多
关键词 薄膜 密度恢复时间 脉冲激光烧蚀 蒙特卡罗模拟
原文传递