To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car...To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average.展开更多
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul...The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water.展开更多
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac...A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%.展开更多
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff...A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.展开更多
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of...A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.展开更多
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o...In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking.展开更多
A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre...A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.展开更多
Intenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of v...Intenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of valve's characteristic on ICP's total performance will found the base for its optimum design. Based on the theoretical and testing fruits of single cylinder prototype, the performance of the valves and complete appliance of the latest is simulated. When the natural frequency of valves is approximately to the round number times of the working frequency, volumetric efficiency is seriously low. The nominal rotational speed of the prototype is nearly to the speed where the volumetric efficiency is lowest, which is harmful to the normal work of ICP, so further structure optimization of valves should be carried out. The change of volumetric efficiency has great influence on the fuel consumption rate, output flow, effective thermal efficiency, effective power, and so on, but little on output pressure.展开更多
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul...In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.展开更多
The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase s...The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase step when outlet valve or inlet valve opens, but is more gently in other time; The volume efficiency is influenced by the output pressure slightly, and decreases as the working rotational speed increases; When the inherent frequency of the valves is integer multiple of the working frequency, the volume efficiency of system will decrease evidently.展开更多
During Jan.1995 to Dec.1996, monthly investigations on the zoobenthic communities of West Lake, samples were collected from six sampling stations. A total of 26 species of macrozoobenthos were identified. The seasonal...During Jan.1995 to Dec.1996, monthly investigations on the zoobenthic communities of West Lake, samples were collected from six sampling stations. A total of 26 species of macrozoobenthos were identified. The seasonal changes in density and biomass of zoobenthos in this lake were analyzed. The annual mean densities were 980~2751 ind/m\+2 and mean biomass was 19.69-122.80 g/m\+2. The densities in winter and early spring were higher than those in summer and autumn. Comparative study of theprevious data (1982 to 1983) collected by the authors, showed that the succession of zoobenthic communities, dominated by \%Procludius choreus\% in density and \%Bellamya purificata\% in biomass, had been occurred in Xiaonan sub\|lake after Qiantang River water was drawn into it; and that the species and biomass of zoobenthos were then increased and the density was decreased. In other sub\|lakes, the dominant species were \%Limnodrilus hoffmeisteri\% and \%Tokunagayusurika akamusi \%in density and \%Branchiura sowerbyi\% and \%Tokunagayusurika akamusi \%in biomass. The water quality was bad in these sub\|lakes because these dominant species are indicators of eutrophication. According to the Margalef index and Goodnight index, West Lake is still an eutrophic lake. Only the water quality of Xiaonan sub\|lake was improved after water drawn from the Qiantang River was introduced into it.展开更多
As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introd...As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified.展开更多
Large water pump motor,whose operation decides the reliability of the whole production line,plays a very important role.Therefore,its online condition monitoring can help companies better know its operation,process fa...Large water pump motor,whose operation decides the reliability of the whole production line,plays a very important role.Therefore,its online condition monitoring can help companies better know its operation,process fault analysis and protection.The essay mainly studies and designs large water pump motor′s real time vibration monitoring and fault diagnosis system.The essay completes the systems project design,the establishment of the system and performance test.Eddy-currentsensor,XM-120 vibration module,XM-320 axial translation module,XM-362 temperature module,XM-360 process amount module and XM-500 gateway module are used to measure the axial vibration and displacement of main motors.Laboratory tests prove that the system can meet the requirements of motor vibration monitoring.展开更多
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T...Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value.展开更多
In the present work,an assessment of the rural water supply potential by mechanical wind pumping around the floodplains of Lake Chad has been considered.Inside the floodplains around Lake Chad,available surface water ...In the present work,an assessment of the rural water supply potential by mechanical wind pumping around the floodplains of Lake Chad has been considered.Inside the floodplains around Lake Chad,available surface water is largely contaminated and represents health hazards to populations.Access to underground and clean water has increasingly become rare.Moreover,clean water scarcity has led to conflict and territorial pressures,which are contributing factors to poverty in the considered area.Four localities,Baga,Baga-Sola,Makari and Nguigmi,respectively,in Nigeria,Chad,Cameroon and Niger have been selected inside the floodplains around Lake Chad,to evaluate the potential of wind power and prospects of windmills development to provide safe drinking-water supply,livestock watering and small-scale irrigation.Long-term satellite-derived data,obtained through the Prediction of Worldwide renewable Energy Resources have been considered suitable and viable alternative to missing site-specific data from ground stations.Windmill of Multi-blade driven piston pump is the preferred water pumping option for this study because of its higher overall system efficiency.The results of this study indicate that mean wind speeds,at 10 m height above ground level,are 4.64 m/s for Baga,4.76 m/s for Baga-Sola,4.32 m/s for Makari and 4.44 m/s for Nguigmi.In addition,wind speeds for Baga,for instance,are in the range of 2.5–10 m(working range of a wind pump),at 10,15,20 and 25 m height agl,for 79.64,82.80,84.79,and 86.19 per cent of the time.Corresponding values for Baga-Sola,Makari and Nguigmi are in the range of 80.50–87.76 per cent,76.86–85,58 per cent,77.92–86.21 per cent,respectively.For a Windmill with a 2 m-blade,a 25 m-height tower and considering a total dynamic head of 30 m,average monthly discharges for the dry season are 1,330,1,374,1,200 and 1,199 m3,respectively for Baga,Baga-Sola,Makari and Nguigmi.Furthermore,corresponding costs of water are 9.53,9.23,10.56 and 10.57 XAF/m3,for Baga,Baga-Sola,Makari and Nguigmi,in that order.展开更多
For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surf...For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surface defect detection,a lightweight detection method based on an improved YOLOv5s method is proposed to replace the traditional manual detection methods.In this method,the MobileNetV3 module replaces the backbone network of YOLOv5s,depth-separable convolution is introduced,the parameters and calculations are reduced,and CIoU_Loss is used as the loss function of the boundary box regression to improve its detection accuracy.A dataset of electronic pump shell defects is established,and the performance of the improved method is evaluated by comparing it with that of the original method.The results show that the parameters and FLOPs are reduced by 49.83%and 61.59%,respectively,compared with the original YOLOv5s model,and the detection accuracy is improved by 1.74%,which is an indication of the superiority of the improved method.To further verify the universality of the improved method,it is compared with the results using the original method on the PASCALVOC2007 dataset,which verifies that it yields better performance.In summary,the improved lightweight method can be used for the real-time detection of electronic water pump shell defects.展开更多
The energy efficient product can be operated with longer duration.They offer wonderful solutions compared to other conventional water pumping system as it needs less maintenance,simple in installation,zero fuel cost,l...The energy efficient product can be operated with longer duration.They offer wonderful solutions compared to other conventional water pumping system as it needs less maintenance,simple in installation,zero fuel cost,longer operating life,highly reliable and free from production of greenhouse gases.In this paper we analyzed the different topologies of DC–DC converter in terms of their operating region of MPPT,quality of input and output currents.We discussed the MPPT algorithms to address partial shading effects in SPV array,present state of the technology,factors affecting the performance of the system,efficiency improvements and identified the research gaps.Also,the economic feasibility analysis has been done for the real time scenario using the Homer Pro software.The estimation of total dynamic head and horse power calculation has been done to decide the total load capacity.The economic analysis results such as cumulative cash flow over project lifetime of 25 years are presented.It is observed that the capital investment requirement is$7,425 for installing Fronius PV system that has a nominal capacity of 2.47 kW and annualized savings will be$134.93.In the long-term perspective,the return on investment is−2.18%as per the present tariff plan.展开更多
This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakis...This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakistan. The design, sizing, cost analysis and steady state analysis of the proposed systems were done in HOMER and dynamic analysis of the designed system with battery bank was performed in MATLAB/Simulink. The simulations performed in HOMER involved proper mapping of the loads which helped to evaluate the PV panel requirement, inverter rating, batteries (in case of battery based solution), modeling of water tank as a deferrable load (in case of solution based of water tank) and detailed cost analysis for a life time of 25 years. To verify the design of the solar water pumping system with battery bank, a simulation in MATLAB/Simulink for study of dynamic behavior of the overall system was performed which involved mathematical modeling of a PV panel, buckboost converter, inverter, battery bank and motor/pump, a perturb and observe maximum power point tracking algorithm based control system. Analysis was conducted based on the economic results that indicate designed solar water pumping system with water tank would be a cheaper solution as compared to solar water pumping system with a battery bank. This work can be taken as a case study for the understanding and optimized designs of solar water pumping system with battery bank and with cylindrical tank in Pakistani conditions.展开更多
With radical socio-economic development and strengthening of regulation of agricultural industrial structure in Hainan Province,fresh water resource becomes increasingly insufficient.Existing water-saving facilities a...With radical socio-economic development and strengthening of regulation of agricultural industrial structure in Hainan Province,fresh water resource becomes increasingly insufficient.Existing water-saving facilities and measures are unable to promote sustainable and stable development of local economy.This needs modern irrigation method.Solar photovoltaic water pumping system is necessary and feasible in Hainan agriculture,and will have directive significance for Hainan Province developing photovoltaic agriculture.展开更多
Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper,our pumping station is being used for water...Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper,our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.展开更多
基金The National Natural Science Foundation of China(No.50676059)
文摘To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average.
基金Supported by Scientific Research Fund of Ningxia University [(E) ndzr09-23]
文摘The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water.
文摘A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%.
基金Supported by Hunan Science and Technology Office(06wk3023)National High Technology Research and Development Program of China(2006AA05Z229)Project-sponsored by SRFfor ROCS,SEM
文摘A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.
基金the National Natural Science Foundation of China(No.51776117)。
文摘A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.
文摘In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking.
基金supported by the National Natural Science Foundation of China (Grant No. 51076147)
文摘A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.
基金supported by National Natural Science Foundation of China (Grant No. 50575107)
文摘Intenal combustion pump (ICP) is a new type power device turning the thermal energy from fuel combustion into fluid pressure energy. Three cylinders prototype has just been developed. The study on the influence of valve's characteristic on ICP's total performance will found the base for its optimum design. Based on the theoretical and testing fruits of single cylinder prototype, the performance of the valves and complete appliance of the latest is simulated. When the natural frequency of valves is approximately to the round number times of the working frequency, volumetric efficiency is seriously low. The nominal rotational speed of the prototype is nearly to the speed where the volumetric efficiency is lowest, which is harmful to the normal work of ICP, so further structure optimization of valves should be carried out. The change of volumetric efficiency has great influence on the fuel consumption rate, output flow, effective thermal efficiency, effective power, and so on, but little on output pressure.
基金Project supported by the Priority Academic Development Program of Jiangsu Higher Education Institutions, ChinaProject(CXZZ12_0680) supported by Postgraduate Innovation Foundation of Jiangsu Province, ChinaProject(12JDG082) supported by the Advanced Talent Foundation of Jiangsu University, China
文摘In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.
基金This project is supported by National Natural Science Foundation of China(No.10342003).
文摘The dynamics differential equations are constructed, and the initial conditions are also given. Simulation shows the following conclusions: The water pressure in cylinder has great instantaneous pulsation and phase step when outlet valve or inlet valve opens, but is more gently in other time; The volume efficiency is influenced by the output pressure slightly, and decreases as the working rotational speed increases; When the inherent frequency of the valves is integer multiple of the working frequency, the volume efficiency of system will decrease evidently.
文摘During Jan.1995 to Dec.1996, monthly investigations on the zoobenthic communities of West Lake, samples were collected from six sampling stations. A total of 26 species of macrozoobenthos were identified. The seasonal changes in density and biomass of zoobenthos in this lake were analyzed. The annual mean densities were 980~2751 ind/m\+2 and mean biomass was 19.69-122.80 g/m\+2. The densities in winter and early spring were higher than those in summer and autumn. Comparative study of theprevious data (1982 to 1983) collected by the authors, showed that the succession of zoobenthic communities, dominated by \%Procludius choreus\% in density and \%Bellamya purificata\% in biomass, had been occurred in Xiaonan sub\|lake after Qiantang River water was drawn into it; and that the species and biomass of zoobenthos were then increased and the density was decreased. In other sub\|lakes, the dominant species were \%Limnodrilus hoffmeisteri\% and \%Tokunagayusurika akamusi \%in density and \%Branchiura sowerbyi\% and \%Tokunagayusurika akamusi \%in biomass. The water quality was bad in these sub\|lakes because these dominant species are indicators of eutrophication. According to the Margalef index and Goodnight index, West Lake is still an eutrophic lake. Only the water quality of Xiaonan sub\|lake was improved after water drawn from the Qiantang River was introduced into it.
文摘As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified.
文摘Large water pump motor,whose operation decides the reliability of the whole production line,plays a very important role.Therefore,its online condition monitoring can help companies better know its operation,process fault analysis and protection.The essay mainly studies and designs large water pump motor′s real time vibration monitoring and fault diagnosis system.The essay completes the systems project design,the establishment of the system and performance test.Eddy-currentsensor,XM-120 vibration module,XM-320 axial translation module,XM-362 temperature module,XM-360 process amount module and XM-500 gateway module are used to measure the axial vibration and displacement of main motors.Laboratory tests prove that the system can meet the requirements of motor vibration monitoring.
基金supported by the China Postdoctoral Science Foundation(20080430747)foundation of Chongqing University Young Talents for Promoting the Innovative Force(qnjj2008-7)
文摘Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value.
文摘In the present work,an assessment of the rural water supply potential by mechanical wind pumping around the floodplains of Lake Chad has been considered.Inside the floodplains around Lake Chad,available surface water is largely contaminated and represents health hazards to populations.Access to underground and clean water has increasingly become rare.Moreover,clean water scarcity has led to conflict and territorial pressures,which are contributing factors to poverty in the considered area.Four localities,Baga,Baga-Sola,Makari and Nguigmi,respectively,in Nigeria,Chad,Cameroon and Niger have been selected inside the floodplains around Lake Chad,to evaluate the potential of wind power and prospects of windmills development to provide safe drinking-water supply,livestock watering and small-scale irrigation.Long-term satellite-derived data,obtained through the Prediction of Worldwide renewable Energy Resources have been considered suitable and viable alternative to missing site-specific data from ground stations.Windmill of Multi-blade driven piston pump is the preferred water pumping option for this study because of its higher overall system efficiency.The results of this study indicate that mean wind speeds,at 10 m height above ground level,are 4.64 m/s for Baga,4.76 m/s for Baga-Sola,4.32 m/s for Makari and 4.44 m/s for Nguigmi.In addition,wind speeds for Baga,for instance,are in the range of 2.5–10 m(working range of a wind pump),at 10,15,20 and 25 m height agl,for 79.64,82.80,84.79,and 86.19 per cent of the time.Corresponding values for Baga-Sola,Makari and Nguigmi are in the range of 80.50–87.76 per cent,76.86–85,58 per cent,77.92–86.21 per cent,respectively.For a Windmill with a 2 m-blade,a 25 m-height tower and considering a total dynamic head of 30 m,average monthly discharges for the dry season are 1,330,1,374,1,200 and 1,199 m3,respectively for Baga,Baga-Sola,Makari and Nguigmi.Furthermore,corresponding costs of water are 9.53,9.23,10.56 and 10.57 XAF/m3,for Baga,Baga-Sola,Makari and Nguigmi,in that order.
基金This work is supported by the Qing Lan Project of the Higher Education Institutions of Jiangsu Province,the 2022 Jiangsu Science and Technology Plan Special Fund(International Science and Technology Cooperation)(BZ2022029).
文摘For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surface defect detection,a lightweight detection method based on an improved YOLOv5s method is proposed to replace the traditional manual detection methods.In this method,the MobileNetV3 module replaces the backbone network of YOLOv5s,depth-separable convolution is introduced,the parameters and calculations are reduced,and CIoU_Loss is used as the loss function of the boundary box regression to improve its detection accuracy.A dataset of electronic pump shell defects is established,and the performance of the improved method is evaluated by comparing it with that of the original method.The results show that the parameters and FLOPs are reduced by 49.83%and 61.59%,respectively,compared with the original YOLOv5s model,and the detection accuracy is improved by 1.74%,which is an indication of the superiority of the improved method.To further verify the universality of the improved method,it is compared with the results using the original method on the PASCALVOC2007 dataset,which verifies that it yields better performance.In summary,the improved lightweight method can be used for the real-time detection of electronic water pump shell defects.
文摘The energy efficient product can be operated with longer duration.They offer wonderful solutions compared to other conventional water pumping system as it needs less maintenance,simple in installation,zero fuel cost,longer operating life,highly reliable and free from production of greenhouse gases.In this paper we analyzed the different topologies of DC–DC converter in terms of their operating region of MPPT,quality of input and output currents.We discussed the MPPT algorithms to address partial shading effects in SPV array,present state of the technology,factors affecting the performance of the system,efficiency improvements and identified the research gaps.Also,the economic feasibility analysis has been done for the real time scenario using the Homer Pro software.The estimation of total dynamic head and horse power calculation has been done to decide the total load capacity.The economic analysis results such as cumulative cash flow over project lifetime of 25 years are presented.It is observed that the capital investment requirement is$7,425 for installing Fronius PV system that has a nominal capacity of 2.47 kW and annualized savings will be$134.93.In the long-term perspective,the return on investment is−2.18%as per the present tariff plan.
文摘This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakistan. The design, sizing, cost analysis and steady state analysis of the proposed systems were done in HOMER and dynamic analysis of the designed system with battery bank was performed in MATLAB/Simulink. The simulations performed in HOMER involved proper mapping of the loads which helped to evaluate the PV panel requirement, inverter rating, batteries (in case of battery based solution), modeling of water tank as a deferrable load (in case of solution based of water tank) and detailed cost analysis for a life time of 25 years. To verify the design of the solar water pumping system with battery bank, a simulation in MATLAB/Simulink for study of dynamic behavior of the overall system was performed which involved mathematical modeling of a PV panel, buckboost converter, inverter, battery bank and motor/pump, a perturb and observe maximum power point tracking algorithm based control system. Analysis was conducted based on the economic results that indicate designed solar water pumping system with water tank would be a cheaper solution as compared to solar water pumping system with a battery bank. This work can be taken as a case study for the understanding and optimized designs of solar water pumping system with battery bank and with cylindrical tank in Pakistani conditions.
基金Education and Teaching Research Project of Hainan University in 2012(hdjy1201)Scientific Research Project of Higher Learning Institu-tions in Hainan Province(Hjjg2013-08)
文摘With radical socio-economic development and strengthening of regulation of agricultural industrial structure in Hainan Province,fresh water resource becomes increasingly insufficient.Existing water-saving facilities and measures are unable to promote sustainable and stable development of local economy.This needs modern irrigation method.Solar photovoltaic water pumping system is necessary and feasible in Hainan agriculture,and will have directive significance for Hainan Province developing photovoltaic agriculture.
文摘Automatic Control of pumps is an interesting proposal to operate water pumping stations among many kinds of water pumping stations according to their functions.In this paper,our pumping station is being used for water supply system. This paper is to introduce the idea of pump controller and the important factors that must be considering when we want to design automatic control system of water pumping stations. Then the automatic control circuit with the function of all components will be introduced.