It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent. In this paper, the appro...It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent. In this paper, the appropriate purge and trap conditions of PCP are determined: the trapped sorbent is TenaxGC; the purge gas is pure nitrogen and purge flow is 40ml/min; the purge time is 30min. A series of standard PCP water samples 5, 10, 50, 100, 200, 400, 800, 1000ppb are analyzed in order to obtain standard curve, and the linear regressive equation obtained is Y=109.65X-687.72, which correlation coefficient r is 0.9949. The precision of the method is determined with 0.5ppb PCP water sample, and the standard deviation measured is 3%. The detection limit for PCP is 0.2ppb.展开更多
Trimethylamine in environment air is concentrated to deactivated SUMMA canister by three-grade cold trap,then analysed by GC-MS.The operation of the method is easy,and no pre-procession.The maximal injection-volume is...Trimethylamine in environment air is concentrated to deactivated SUMMA canister by three-grade cold trap,then analysed by GC-MS.The operation of the method is easy,and no pre-procession.The maximal injection-volume is up to 2L.The analysis method is adopted to the SIM method of GC-MS.The precision、sensitivity and accuracy of the method is good,the MDL of the method is 1.6×10-2mg/m3.展开更多
文摘It is convenient and time saving to analyze pentachlorophenol (PCP) in water by purge and trap concentrator coupled to gas chromatography that avoids employing a great deal of organic solvent. In this paper, the appropriate purge and trap conditions of PCP are determined: the trapped sorbent is TenaxGC; the purge gas is pure nitrogen and purge flow is 40ml/min; the purge time is 30min. A series of standard PCP water samples 5, 10, 50, 100, 200, 400, 800, 1000ppb are analyzed in order to obtain standard curve, and the linear regressive equation obtained is Y=109.65X-687.72, which correlation coefficient r is 0.9949. The precision of the method is determined with 0.5ppb PCP water sample, and the standard deviation measured is 3%. The detection limit for PCP is 0.2ppb.
文摘Trimethylamine in environment air is concentrated to deactivated SUMMA canister by three-grade cold trap,then analysed by GC-MS.The operation of the method is easy,and no pre-procession.The maximal injection-volume is up to 2L.The analysis method is adopted to the SIM method of GC-MS.The precision、sensitivity and accuracy of the method is good,the MDL of the method is 1.6×10-2mg/m3.