In 1981 Taiwan entered a period of intense construction, meaning that today many buildings are more than 30 years old. Lack of maintenance has led to frequent safety incidents involving external walls. This study focu...In 1981 Taiwan entered a period of intense construction, meaning that today many buildings are more than 30 years old. Lack of maintenance has led to frequent safety incidents involving external walls. This study focuses on a deterioration diagnostic model for external wall tiles of aged buildings, using both stage 1 and stage 2 diagnostic methods. The visual test results are categorized based on impact on public safety, and renovation strategies are proposed. Stage 1 diagnosis mainly adopted the DER visual inspection deterioration assessment method. For enhance the accuracy, this research adopted the Infrared Thermal Imaging detection method to double confirm the visual inspection results. After producing an external wall tile Condition Indicator (CI). For stage 1 diagnostic results that fall in a gray area, stage 2 diagnosis was carried out using a tap tone test, followed by fast Fourier transform and pattern recognition to analyze the tapping results. Finally, the study provides a deterioration evaluation criteria for external wall tiles replacement recommendations and a standard operating procedure for deterioration diagnosis. The study also recommends directions for future amendment of regulations, and provides a basis of reference for the government in determining urban renewal, renovation and maintenance strategies.展开更多
The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures...The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions.展开更多
文摘In 1981 Taiwan entered a period of intense construction, meaning that today many buildings are more than 30 years old. Lack of maintenance has led to frequent safety incidents involving external walls. This study focuses on a deterioration diagnostic model for external wall tiles of aged buildings, using both stage 1 and stage 2 diagnostic methods. The visual test results are categorized based on impact on public safety, and renovation strategies are proposed. Stage 1 diagnosis mainly adopted the DER visual inspection deterioration assessment method. For enhance the accuracy, this research adopted the Infrared Thermal Imaging detection method to double confirm the visual inspection results. After producing an external wall tile Condition Indicator (CI). For stage 1 diagnostic results that fall in a gray area, stage 2 diagnosis was carried out using a tap tone test, followed by fast Fourier transform and pattern recognition to analyze the tapping results. Finally, the study provides a deterioration evaluation criteria for external wall tiles replacement recommendations and a standard operating procedure for deterioration diagnosis. The study also recommends directions for future amendment of regulations, and provides a basis of reference for the government in determining urban renewal, renovation and maintenance strategies.
基金financial support from the Housing Research Center of UPMNAEIM Company
文摘The Industrialized Building System (IBS) was recently introduced to minimize the time and cost of project construction. Accordingly, ensuring the integration of the connection of precast components in IBS structures is an important factor that ensures stability of buildings subjected to dynamic loads from earthquakes, vehicles, and machineries. However, structural engineers still lack knowledge on the proper connection and detailed joints o fiBS structure construction. Therefore, this study proposes a special precast concrete wall-to-wall connection system for dynamic loads that resists multidirectional imposed loads and reduces vibration effects (PI2014701723). This system is designed to connect two adjacent precast wall panels by using two steel U-shaped channels (i.e., male and female joints). During casting, each joint is adapted for incorporation into a respective wall panel after considering the following conditions: one side of the steel channel opens into the thickness face of the panel; a U-shaped rubber is implemented between the two channels to dissipate the vibration effect; and bolts and nuts are used to create an extension between the two U-shaped male and female steel channels. The developed finite element model of the precast wall is subjected to cyclic loads to evaluate the performance of the proposed connection during an imposed dynamic load. Connection performance is then compared with conventional connections based on the energy dissipation, stress, deformation, and concrete damage in the plastic range. The proposed precast connection is capable of exceeding the energy absorption of precast walls subjected to dynamic load, thereby improving its resistance behavior in all principal directions.