The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the stu...The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.展开更多
In the building with many transparent envelopes,solar radiation can irradiate on the local surface of floor and cause overheating.The local thermal comfort in the room will be dissatisfactory and the thermal performan...In the building with many transparent envelopes,solar radiation can irradiate on the local surface of floor and cause overheating.The local thermal comfort in the room will be dissatisfactory and the thermal performance of radiant floor will be strongly affected.However,in many current calculation models,solar radiation on the floor surface is assumed to be uniformly distributed,resulting in the inaccurate evaluation of the thermal performance of the radiant floor.In this paper,a calculation model based on the theory of discretization and the RC thermal network is proposed to calculate the dynamic thermal performance of radiant floor with the consideration of unevenly distributed solar radiation.Then,the discretization model is experimentally validated and is used to simulate a radiant floor heating system of an office room in Lhasa.It is found that with the unevenly distributed solar radiation,the maximum surface temperature near the south exterior window can reach up to 35.6℃,which exceeds the comfort temperature limit and is nearly 8.5℃higher than that in the north zone.Meanwhile,the heating capacity of the radiant floor in the irradiated zone can reach up to 171 W/m^(2),while that in the shaded zone is only 79 W/m^(2).The model with the assumption of uniformly distributed solar radiation ignores the differences between the south and north zones and fails to describe local overheating in the irradiated zones.By contrast,the discretization model can more accurately evaluate the thermal performance of radiant floor with the influence of real solar radiation.Based on this discretization model,novel design and control schemes of radiant floor heating system can be proposed to alleviate local overheating and reduce heating capacity in the irradiated zone.展开更多
This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established ...This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established and verified by experiments.The temperature distribution and heat transfer process of each part are comprehensively obtained,and the structure is optimized.The results show that the cement-tile floor has the better heat transfer performance of the two.When under the same inlet water temperature and flow rate,the keel-wood floor's surface temperature distribution is about 2℃ lower than that of the cement-tile floor.The inlet water temperature of cement-tile floor is about 10℃ lower than that of keel-wood structure when the floor surface temperature is the same.During a longitudinal heat transfer above MHPA,the floor surface temperature decreases by 0.5℃ for every 10 mm filling layer increase.In order to reduce the non-uniformity of the floor's surface temperature and improve the thermal comfort of the heated room,the optimal structure for a floor is given,with the maximum surface temperature difference reduced by 3.35℃.We used research focusing on new radiant floor heating,with advantages including high efficiency heat transfer,low water supply temperature,simple waterway structure,low resistance and leakage risk,to provide theory and data to support the application of an effective radiant floor heating based on MHPA.展开更多
Due to the wide application of floor heating systems, the radiant floor cooling systems has developed rapidly in recent years. In this paper, TRNSYS numerical simulation methods are used to study the influence of chil...Due to the wide application of floor heating systems, the radiant floor cooling systems has developed rapidly in recent years. In this paper, TRNSYS numerical simulation methods are used to study the influence of chilled water supply temperature and flow rate on the cold storage characteristics of a standard floor structure for office buildings in northern China. The results are verified by experimental measurements. The functional relationship between the saturated cold storage time and the chilled water flow rate is quadratic polynomial, while the changes of supply-water temperature have no effect on the saturation time;the supply-water temperature has a linear relationship with the saturated cold storage volume, while the chilled water flow rate has almost no effect on the saturation cold storage volume. The accumulated cold volume of floor changes with time in an exponential distribution with four coefficients, and the floor has the characteristics of rapid cold storage. This paper is instructive for the design, application and promotion of radiant floor cooling systems.展开更多
A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the s...A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.展开更多
Pre-dehumidification time(τ_(pre))and pre-dehumidification energy consumption(E_(pre))play important roles in preventing the condensation of moisture on the floors of rooms that use a radiant floor cooling(RFC)system...Pre-dehumidification time(τ_(pre))and pre-dehumidification energy consumption(E_(pre))play important roles in preventing the condensation of moisture on the floors of rooms that use a radiant floor cooling(RFC)system.However,there are few theoretical or experimental studies that focus on these two important quantities.In this study,an artificial neural network(ANN)was used to predict condensation risk for the integration of RFC systems with mixed ventilation(MV),stratum ventilation(SV),and displacement ventilation(DV)systems.A genetic algorithm-back-propagation(GA-BP)neural network model was established to predict τ_(pre) and E_(pre).Both training data and validation data were obtained from tests in a computational fluid dynamics(CFD)simulation.The results show that the established GA-BP model can predict τ_(pre) and E_(pre) well.The coefficient of determination(R^(2))of τ_(pre) and of E_(pre) were,respectively,0.973 and 0.956.For an RFC system integrated with an MV,SV,or DV system,the lowest values of τ_(pre) and E_(pre) were with the DV system,23.1 s and 0.237 kWh,respectively,for a 67.5 m^(3) room.Therefore,the best pre-dehumidification effect was with integration of the DV and RFC systems.This study showed that an ANN-based method can be used for predictive control for condensation prevention in RFC systems.It also provides a novel and effective method by which to assess the pre-dehumidification control of radiant floor surfaces.展开更多
A radiant floor cooling system(RFCS)is a high-comfort and low energy consumption system suitable for residential buildings.Radiant floor systems usually work with fresh air,and their operating performance is affected ...A radiant floor cooling system(RFCS)is a high-comfort and low energy consumption system suitable for residential buildings.Radiant floor systems usually work with fresh air,and their operating performance is affected by climatic conditions.Indoor and outdoor environmental disturbances and the system’s control strategy affect the indoor thermal comfort and energy efficiency of the system.Firstly,a multi-story residential building model was established in this study.Transient system simulation program was used to study the operation dynamics of three control strategies of the RFCS based on the calibrated model.Then,the performance of the control strategies in five climate zones in China were compared using multi-criteria decision-making in combination.The results show that control strategy has a negligible effect on condensation risk,but the thermal comfort and economic performance differ for different control strategies.The adaptability of different control strategies varies in different climate zones based on the consideration of multiple factors.The performance of the direct-ground cooling source system is better in Hot summer and warm winter zone.The variable air volume control strategy scores higher in Serve cold and Temperate zones,and the hours exceeding thermal comfort account for less than 3%of the total simulation period.Therefore,it is suggested to choose the RFCS control strategy for residential buildings according to the climate zone characteristics,to increase the energy savings.Our results provide a reliable reference for implementing RFCSs in residential buildings.展开更多
The main features of top-floor rooms with natural ventilation are identified by investigating indoor thermal environment in summer season. One is high indoor air temperature, for this reason the indoor climate is far ...The main features of top-floor rooms with natural ventilation are identified by investigating indoor thermal environment in summer season. One is high indoor air temperature, for this reason the indoor climate is far beyond the thermal comfort standard; the other is the inhomogeneous temperature distribution of the inner wall surfaces, and high temperature of the inner surface of the roof causes much scorching to the head of occupant. This is the characteristic of such rooms.Both features mentioned above should be considered comprehensively for thc evaluation of indoor thermal environment of the top-floor rooms with asymmetric radiant field. In order to characterize the indoor thermal environment of the rooms, the heat stress index, HSI and radiant heat flux reaching human head, QR should be introduced simultaneously as thermal indexes for the indoor climate evaluation. The application of the indexes to a topfloor room is presented and analyzed.展开更多
基金Supported by Key Scientific Research Projects of Sichuan Provincial Department of Technology (2010JY0165)Key Special Scientific Research Projects of Mianyang City of Sichuan Province (09Y003-13)Key Scientific Research Projects of Sichuan Provincial Department of Education (2003A112)
文摘The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.
基金This research work was financially supported by the Natural Science Foundation of Sichuan Province(No.2022NSFSC1944)the National Natural Science Foundation of China(No.51708453).
文摘In the building with many transparent envelopes,solar radiation can irradiate on the local surface of floor and cause overheating.The local thermal comfort in the room will be dissatisfactory and the thermal performance of radiant floor will be strongly affected.However,in many current calculation models,solar radiation on the floor surface is assumed to be uniformly distributed,resulting in the inaccurate evaluation of the thermal performance of the radiant floor.In this paper,a calculation model based on the theory of discretization and the RC thermal network is proposed to calculate the dynamic thermal performance of radiant floor with the consideration of unevenly distributed solar radiation.Then,the discretization model is experimentally validated and is used to simulate a radiant floor heating system of an office room in Lhasa.It is found that with the unevenly distributed solar radiation,the maximum surface temperature near the south exterior window can reach up to 35.6℃,which exceeds the comfort temperature limit and is nearly 8.5℃higher than that in the north zone.Meanwhile,the heating capacity of the radiant floor in the irradiated zone can reach up to 171 W/m^(2),while that in the shaded zone is only 79 W/m^(2).The model with the assumption of uniformly distributed solar radiation ignores the differences between the south and north zones and fails to describe local overheating in the irradiated zones.By contrast,the discretization model can more accurately evaluate the thermal performance of radiant floor with the influence of real solar radiation.Based on this discretization model,novel design and control schemes of radiant floor heating system can be proposed to alleviate local overheating and reduce heating capacity in the irradiated zone.
基金The authors gratefully acknowledge the financial support provided by the National Natural Science Foundation of China(No.51778010),“Optimization design method of BIPV/T and solar heat pump coupled energy supply system”.
文摘This paper proposes two new radiant floor heating structures based on micro heat pipe array(MHPA),namely cement-tile floor and keel-wood floor.The numerical models for these different floor structures are established and verified by experiments.The temperature distribution and heat transfer process of each part are comprehensively obtained,and the structure is optimized.The results show that the cement-tile floor has the better heat transfer performance of the two.When under the same inlet water temperature and flow rate,the keel-wood floor's surface temperature distribution is about 2℃ lower than that of the cement-tile floor.The inlet water temperature of cement-tile floor is about 10℃ lower than that of keel-wood structure when the floor surface temperature is the same.During a longitudinal heat transfer above MHPA,the floor surface temperature decreases by 0.5℃ for every 10 mm filling layer increase.In order to reduce the non-uniformity of the floor's surface temperature and improve the thermal comfort of the heated room,the optimal structure for a floor is given,with the maximum surface temperature difference reduced by 3.35℃.We used research focusing on new radiant floor heating,with advantages including high efficiency heat transfer,low water supply temperature,simple waterway structure,low resistance and leakage risk,to provide theory and data to support the application of an effective radiant floor heating based on MHPA.
基金financially supported by the Plan of Guidance and Cultivation for Young Innovative Talents of Shandong Provincial Colleges and Universitiesfinancially supported by the National Natural Science Foundation of China(Grant No.51808321)。
文摘Due to the wide application of floor heating systems, the radiant floor cooling systems has developed rapidly in recent years. In this paper, TRNSYS numerical simulation methods are used to study the influence of chilled water supply temperature and flow rate on the cold storage characteristics of a standard floor structure for office buildings in northern China. The results are verified by experimental measurements. The functional relationship between the saturated cold storage time and the chilled water flow rate is quadratic polynomial, while the changes of supply-water temperature have no effect on the saturation time;the supply-water temperature has a linear relationship with the saturated cold storage volume, while the chilled water flow rate has almost no effect on the saturation cold storage volume. The accumulated cold volume of floor changes with time in an exponential distribution with four coefficients, and the floor has the characteristics of rapid cold storage. This paper is instructive for the design, application and promotion of radiant floor cooling systems.
文摘A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.
基金funded by the Natural Science Foundation of Shan-dong Province(ZR2021ME199,ZR2020ME211)the Support Plan for Outstanding Youth Innovation Team in Colleges and Universities of Shandong Province(2019KJG005)supported by the Plan of Introduction and Cultivation for Young Innovative Talents in Colleges and Universities of Shandong Province.
文摘Pre-dehumidification time(τ_(pre))and pre-dehumidification energy consumption(E_(pre))play important roles in preventing the condensation of moisture on the floors of rooms that use a radiant floor cooling(RFC)system.However,there are few theoretical or experimental studies that focus on these two important quantities.In this study,an artificial neural network(ANN)was used to predict condensation risk for the integration of RFC systems with mixed ventilation(MV),stratum ventilation(SV),and displacement ventilation(DV)systems.A genetic algorithm-back-propagation(GA-BP)neural network model was established to predict τ_(pre) and E_(pre).Both training data and validation data were obtained from tests in a computational fluid dynamics(CFD)simulation.The results show that the established GA-BP model can predict τ_(pre) and E_(pre) well.The coefficient of determination(R^(2))of τ_(pre) and of E_(pre) were,respectively,0.973 and 0.956.For an RFC system integrated with an MV,SV,or DV system,the lowest values of τ_(pre) and E_(pre) were with the DV system,23.1 s and 0.237 kWh,respectively,for a 67.5 m^(3) room.Therefore,the best pre-dehumidification effect was with integration of the DV and RFC systems.This study showed that an ANN-based method can be used for predictive control for condensation prevention in RFC systems.It also provides a novel and effective method by which to assess the pre-dehumidification control of radiant floor surfaces.
基金This work was funded by the Natural Science Foundation of Shandong Province(ZR2021ME199,ZR2021ME237)the Support Plan for Outstanding Youth Innovation Team in Colleges and Universities of Shandong Province(2019KJG005).This work was also supported by the Plan of Introduction and Cultivation for Young Innovative Talents in Colleges and Universities of Shandong Province,and Funding for Domestic Visiting Scholars at Shandong Jianzhu University.
文摘A radiant floor cooling system(RFCS)is a high-comfort and low energy consumption system suitable for residential buildings.Radiant floor systems usually work with fresh air,and their operating performance is affected by climatic conditions.Indoor and outdoor environmental disturbances and the system’s control strategy affect the indoor thermal comfort and energy efficiency of the system.Firstly,a multi-story residential building model was established in this study.Transient system simulation program was used to study the operation dynamics of three control strategies of the RFCS based on the calibrated model.Then,the performance of the control strategies in five climate zones in China were compared using multi-criteria decision-making in combination.The results show that control strategy has a negligible effect on condensation risk,but the thermal comfort and economic performance differ for different control strategies.The adaptability of different control strategies varies in different climate zones based on the consideration of multiple factors.The performance of the direct-ground cooling source system is better in Hot summer and warm winter zone.The variable air volume control strategy scores higher in Serve cold and Temperate zones,and the hours exceeding thermal comfort account for less than 3%of the total simulation period.Therefore,it is suggested to choose the RFCS control strategy for residential buildings according to the climate zone characteristics,to increase the energy savings.Our results provide a reliable reference for implementing RFCSs in residential buildings.
基金This work was supported by the National Natural Science Foundation for Distinguished Young Scholars (Grant No. 50125821)
文摘The main features of top-floor rooms with natural ventilation are identified by investigating indoor thermal environment in summer season. One is high indoor air temperature, for this reason the indoor climate is far beyond the thermal comfort standard; the other is the inhomogeneous temperature distribution of the inner wall surfaces, and high temperature of the inner surface of the roof causes much scorching to the head of occupant. This is the characteristic of such rooms.Both features mentioned above should be considered comprehensively for thc evaluation of indoor thermal environment of the top-floor rooms with asymmetric radiant field. In order to characterize the indoor thermal environment of the rooms, the heat stress index, HSI and radiant heat flux reaching human head, QR should be introduced simultaneously as thermal indexes for the indoor climate evaluation. The application of the indexes to a topfloor room is presented and analyzed.