期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
Isomeric fluorescence sensors for wide range detection of ionizing radiations
1
作者 Jimin Han Tianyu Yang +1 位作者 Li Yang Yuanjian Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期247-257,共11页
In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduce... In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduced electron transfer(PET)effect.Two perylene diimide isomers PDI-P and PDI-B were designed and synthesized,and their molecular structures were characterized by high-resolution Fourier transform mass spectrometry(HRMS),nuclear magnetic resonance hydrogen and carbon spectroscopy(~1H and~(13)C NMR).The interaction between ionizing radiation and fluorescent molecules was simulated by HCl titration.The results show that combining PDIs and HCl can improve fluorescence through the retro-PET process.Despite the similarities in chemical structures,the fluorescent enhancement multiple of PDI-B with aromatic amine as electron donor is much higher than that of PDI-P with alkyl amine.In the direct irradiation experiments of ionizing radiation,the emission enhancement multiples of PDI-P and PDI-B are 2.01 and 45.4,respectively.Furthermore,density functional theory(DFT)and time-dependent density functional theory(TDDFT)calculations indicate that the HOMO and HOMO-1 energy ranges of PDI-P and PDI-B are 0.54 e V and 1.13 e V,respectively.A wider energy range has a stronger driving force on electrons,which is conducive to fluorescence quenching.Both femtosecond transient absorption spectroscopy(fs-TAS)and transient fluorescence spectroscopy(TFS)tests show that PDI-B has shorter charge separation lifetime and higher electron transfer rate constant.Although both isomers can significantly reduce LOD during PET process,PDI-B with aromatic amine has a wider detection range of 0.118—240 Gy due to its larger emission enhancement,which is a leap of three orders of magnitude.It breaks through the detection range of gamma radiation reported in existing studies,and provides theoretical support for the further study of sensitive and effective new materials for ionizing radiation detection. 展开更多
关键词 Perylene imide Intramolecular PET Ionizing radiation detection Fluorescence sensor ISOMERS
下载PDF
Application of Optical Fiber in Radiation Detection Systems 被引量:1
2
作者 Francisco Antonio Brandao Junior Antonella Lombardi Costa Amo Heeren de Oliveira 《Journal of Chemistry and Chemical Engineering》 2016年第3期120-127,共8页
In the last years, the production of optical fibers cables has made possible the development of a range of spectroscopic probes for in situ analysis performing beyond nondestructive tests, environmental monitoring, se... In the last years, the production of optical fibers cables has made possible the development of a range of spectroscopic probes for in situ analysis performing beyond nondestructive tests, environmental monitoring, security investigation, application in radiotherapy for dose monitoring, verification and validation. In this work, a system using an optical fiber cable to electromagnetic signal transmission from a NaI(TI) radiation detector is presented. The innovative device takes advantage mainly of the optical fibers large passband, small signal attenuation and immunity to electromagnetic interference to application for radiation detection systems. The main aim was to simplify the detection system making it to reach areas where the conventional device cannot access due to its lack of mobility and external dimensions. Some tests with this innovative system are presented and the results stimulate the continuity of the researches. 展开更多
关键词 NaI(T1) optical fiber radiation detection scintillator
下载PDF
Atmosphere Transmission Performance for 0.4 μm~0.8 μm Ray Radiation in Middle Latitude of China
3
作者 WU Jian-hui YANG Kun-tao XIANG Qiao-lian ZHANG Nan-yang 《Semiconductor Photonics and Technology》 CAS 2009年第1期34-40,共7页
This paper researched on the atmospheric transmission performance of 0.4 μm~0.8 μm ray radiation based on the characteristic of the middle latitude atmosphere in China.By analysis of the characteristic of the actua... This paper researched on the atmospheric transmission performance of 0.4 μm~0.8 μm ray radiation based on the characteristic of the middle latitude atmosphere in China.By analysis of the characteristic of the actual atmosphere,the absorption of molecular and the scattering of the steam and ozone,as well as the aerosol scattering(big granule scattering) are play a leading role to the 0.4 μm~0.8 μm ray radiation.Then a better atmospheric transmission formula in horizontal path has been deducted.The result of computer simulation indicates that this equation can best calculate the transmission performance of 0.4 μm~0.8 μm visible radiation in the middle latitude area of China.This computing result was applied to the nuclear explosion parameter detection system based on 0.4 μm~0.8 μm visible radiation.Through nuclear explosion simulator to produce ray radiation,the tested result indicates that this method has the better measuring precision than the traditional method with the software of LOWTRAN.The calculation result of this formula not only can apply directly to each kind of optoelectronics detecting system,but also to the optical wireless communication system based on the 0.4 μm~0.8 μm ray radiation. 展开更多
关键词 middle latitude atmosphere atmospheric transmission radiation detection ABSORPTION SCATTERING
下载PDF
闪烁晶体——辐射探测用单晶
4
作者 殷之文 李培俊 《人工晶体学报》 EI CAS CSCD 北大核心 2000年第S1期2-,共1页
Phosphor converts excitation energy into light,resulting in lumminescence.The luminescence caused by radiation is called scintillation.Since the discovery of the scintillation in NaI∶Tl crystal in 1948,a series of ma... Phosphor converts excitation energy into light,resulting in lumminescence.The luminescence caused by radiation is called scintillation.Since the discovery of the scintillation in NaI∶Tl crystal in 1948,a series of materials with profound scintillating characteristics have been developed and have found wide applications for radiation detection in different fields such as nuclear physics,high energy physics,medical diagnostic imaging,geophysics exploration,clandestine explosive finding and many industrial measuring systems. Inorganic scintillating crystals have superior characteristics over their organic counterparts and some kinds of ceramics,glasses and powders that do have their scintillation effects.We will confine ourselves mainly to inorganic scintillating crystals in this presentation.. 展开更多
关键词 scintillation crystal radiation detection NaI:Tl BGO crystal PWO crystal BaF 2 C sI:Tl
下载PDF
Development of gated fiber detectors for laser-induced strong electromagnetic pulse environments 被引量:8
5
作者 Po Hu Zhi-Guo Ma +5 位作者 Kai Zhao Guo-Qiang Zhang De-Qing Fang Bao-Ren Wei Chang-Bo Fu Yu-Gang Ma 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期36-44,共9页
With the development of laser technologies,nuclear reactions can happen in high-temperature plasma environments induced by lasers and have attracted a lot of attention from different physical disciplines.However,studi... With the development of laser technologies,nuclear reactions can happen in high-temperature plasma environments induced by lasers and have attracted a lot of attention from different physical disciplines.However,studies on nuclear reactions in plasma are still limited by detecting technologies.This is mainly due to the fact that extremely high electromagnetic pulses(EMPs)can also be induced when high-intensity lasers hit targets to induce plasma,and then cause dysfunction of many types of traditional detectors.Therefore,new particle detecting technologies are highly needed.In this paper,we report a recently developed gated fiber detector which can be used in harsh EMP environments.In this prototype detector,scintillating photons are coupled by fiber and then transferred to a gated photomultiplier tube which is located far away from the EMP source and shielded well.With those measures,the EMPs can be avoided which may result that the device has the capability to identify a single event of nuclear reaction products generated in laser-induced plasma from noise EMP backgrounds.This new type of detector can be widely used as a time-of-flight(TOF)detector in high-intensity laser nuclear physics experiments for detecting neutrons,photons,and other charged particles. 展开更多
关键词 Gated fiber detector radiation detection High-intensity laser Strong electromagnetic pulses
下载PDF
Effect of dimensional expansion on carrier transport behaviors of the hexagonal Bi-based perovskite crystals 被引量:1
6
作者 Qihao Sun Bao Xiao +7 位作者 Leilei Ji Dou Zhao Jinjin Liu Wei Zhang Menghua Zhu Wanqi Jie Bin-Bin Zhang Yadong Xu 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第3期459-465,I0013,共8页
All-inorganic Cs_(3)Bi_(2)I_(9)(CBI)halide perovskites are sought to be candidate for photoelectrical materials because of their low toxicity and satisfactory stability.Unfortunately,the discrete molecular[Bi2I9]3−clu... All-inorganic Cs_(3)Bi_(2)I_(9)(CBI)halide perovskites are sought to be candidate for photoelectrical materials because of their low toxicity and satisfactory stability.Unfortunately,the discrete molecular[Bi2I9]3−clusters limit the charge-transport behaviors.Herein,the defect halide perovskite based on trivalent Bi^(3+)is expanded to Cs_(3)Bi_(2)I_(6)Br_(3)(CBIB).Centimeter-size CBIB single crystal(Φ15×70 mm^(3))was grown by the vertical Bridgeman method.The powder X-ray diffraction analysis shows that CBIB has structure with lattice parameters of a=b=8.223Å,c=10.024Å,α=β=90°andγ=120°.The density functional theory(DFT)calculations demonstrate that the charge density distribution was enhanced after the dimensional expansion.The enhancement of carrier transport ability of(00l)in-plane is characterized before and after dimensional improvement.The obtained CBIB(001)exhibited an electron mobility up to 40.03 cm^(2)V^(−1)s^(−1)by time-of-flight(TOF)technique,higher than 26.46 cm^(2)V^(−1)s^(−1)of CBI(001).Furthermore,the X-ray sensitivity increases from 707.81μC Gy^(−1)cm^(−2)for CBI(001)to 3194.59μC Gy−1 cm^(−2)for CBIB(001).This research will deepen our understanding of Bi-based perovskite materials and afford more promising strategies for lead-free perovskite optoelectronic devices modification. 展开更多
关键词 Bi-based perovskite Dimensional expansion Carrier transport Bridgeman method radiation detection
下载PDF
Super‑elastic Scintillating Fibers and Fabrics for Efficient and Visual Radiation Detection
7
作者 Minghui Du Jin Wang +7 位作者 Sijia Xu Hongwei Li Zhihao Zhang Yankun Qi Shichao Lv Jianrong Qiu Yurong Yan Shifeng Zhou 《Advanced Fiber Materials》 SCIE EI CAS 2023年第4期1493-1504,共12页
The fabrication of advanced radiation detectors is an important subject due to the wide use of radiation sources in scientific instruments,medical services,security check,non-destructive inspection,and nuclear industr... The fabrication of advanced radiation detectors is an important subject due to the wide use of radiation sources in scientific instruments,medical services,security check,non-destructive inspection,and nuclear industries.However,the manufacture of flexible and stretchable radiation detectors remains a challenge.Here,we report the scalable fabrication of super-elastic scintillating fibers and fabrics for visual radiation detection by thermal drawing and melt-spinning methods using styrene-b-(ethylene-co-butylene)-b-styrene,and scintillating Gd_(2)O_(2)S:Tb(GOS).Microstructure evolution,rheological properties,and radiation-composite interaction are studied to reveal the excellent processability,elasticity,and radiation detection ability of the fabricated fibers.Benefiting from the physical crosslinking structural features of the polymer matrix and the excellent radiation absorption capacities of GOS,the resulting fiber can sustain high strains of 765%with a high content of GOS dopants(2 wt.%)and has excellent X-ray detection performance with the limit down to 53 nGy_(air)s^(-1).Furthermore,stretchable fabrics are constructed,and their applications in various fields,such as radiation warning,and X-ray imaging,are demonstrated.Our work not only provides a new type of super-elastic scintillating fibers and fabrics for smart textiles but also demonstrates their potential applications in the nuclear field. 展开更多
关键词 Elastic fiber radiation detection Optical materials X-ray imaging
原文传递
Organic–inorganic hybrid perovskite scintillators for mixed field radiation detection 被引量:3
8
作者 Mengling Xia Guangda Niu +17 位作者 Linyue Liu Runlong Gao Tong Jin Pengying Wan Weicheng Pan Xianpeng Zhang Zuoxiang Xie Sam Teale Zenghua Cai Jiajun Luo Shan Zhao Haodi Wu Shiyou Chen Zhiping Zheng Qingguo Xie Xiaoping Ouyang Edward HSargent Jiang Tang 《InfoMat》 SCIE CAS 2022年第9期97-108,共12页
Sensitive and fast detection of neutrons and gamma rays is vital for homeland security,high-energy physics,and proton therapy.Fast-neutron detectors rely on light organic scintillators,andγ-ray detectors use heavy in... Sensitive and fast detection of neutrons and gamma rays is vital for homeland security,high-energy physics,and proton therapy.Fast-neutron detectors rely on light organic scintillators,andγ-ray detectors use heavy inorganic scintillators and semiconductors.Efficient mixed-field detection using a single material is highly challenging due to their contradictory requirements.Here we report hybrid perovskites(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)that combine light organic cations and heavy inorganic skeletons at a molecular level to achieve unprecedented performance for mixed-field radiation detection.High neutron absorption due to a high density of hydrogen,strong radiative recombination within the highly confined[PbX_(6)]^(4-)layer,and sub-nanometer distance between absorption sites and radiative centers,enable a light yield of 41000 photons/MeV,detection pulse width of 2.97 ns and extraordinary linearity response toward both fast neutrons andγ-rays,outperforming commonly used fast-neutron scintillators.Neutron energy spectrum,time-of-flight based fast-neutron/γ-ray discrimination and neutron yield monitoring were all successfully achieved using(C_(8)H_(12)N)_(2)Pb(Br_(0.95)Cl_(0.05))_(4)detectors.We further demonstrate the monitoring of reaction kinetics and total power of a nuclear fusion reaction.We envision that molecular hybridized scintillators open a new avenue for mixed-field radiation detection and imaging. 展开更多
关键词 fast neutron mixed-field radiation detection organic-inorganic hybrid PEROVSKITE
原文传递
Properties study of ZnO:Ga crystal on pulsed radiation detections
9
作者 马彦良 欧阳晓平 +4 位作者 张景文 张忠兵 潘洪波 陈亮 刘林月 《Chinese Physics C》 SCIE CAS CSCD 2010年第3期354-358,共5页
In this paper, properties on pulsed radiation detections of ZnO:Ga crystal grew by a magnetron sputtering method were studied. The time response to pulsed laser, pulsed hard X rays and single α particles, the energy... In this paper, properties on pulsed radiation detections of ZnO:Ga crystal grew by a magnetron sputtering method were studied. The time response to pulsed laser, pulsed hard X rays and single α particles, the energy response to pulsed hard X ray, the scintillation efficiency to γ rays, the response to pulsed proton, and the relations of the light intensity varied with the proton energy were measured and analyzed in detail. Results show that the ZnO:Ga crystal has potential applications in the regime of pulse radiation detection. 展开更多
关键词 ZnO:Ga inorganic scintillator radiation detection time response energy response luminescence efficiency
原文传递
A uranyl based coordination polymer showing response to low-dosage ionizing radiations down to 10^(−5) Gy
10
作者 Jian Xie Yaxing Wang +6 位作者 Wei Liu Chengyu Liang Yugang Zhang Lanhua Chen Daopeng Sheng Zhifang Chai Shuao Wang 《Science China Chemistry》 SCIE EI CAS CSCD 2020年第11期1608-1612,共5页
Radiation detection material is a central component of nuclear technology finding applications in many critical fields.Developing a highly radiation-sensitive material that shows a facilely detectable response to ultr... Radiation detection material is a central component of nuclear technology finding applications in many critical fields.Developing a highly radiation-sensitive material that shows a facilely detectable response to ultra-low dosage of radiation is a long-term research target and remains to be a challenge.Previously reported most optimal chemical radiation dosimeter can detect low-dosage X-andγ-ray radiations down to 10^(−4) Gy.We document here a new photoresponsive coordination polymer showing upgraded radiation detection capabilities with the detection limit on the radiation dose one order of magnitude lower than the previous record.The radiation induced photoluminescence quenching process was elucidated by multiple spectroscopic characterizations. 展开更多
关键词 URANIUM photoluniinescence radiation detection DOSIMETER
原文传递
An evaluation method for nuclear radiation detection performance of glass scintillator
11
作者 Zhehao Hua Sen Qian +20 位作者 Hua Cai Dejing Du Ruirui Fan Jifeng Han Chen Hu Peng Hu Shan Liu Yong Liu Lishuang Ma Laishun Qin Jing Ren Ruiqiang Song Zexuan Sui Xilei Sun Xinyuan Sun Gao Tang Zhigang Wang Qi Wu Dong Yang Lirong Zheng Yao Zhu 《Radiation Detection Technology and Methods》 2024年第2期1107-1119,共13页
Purpose Glass is a potential choice for the scintillator in Hadronic calorimetry(HCAL)of the CEPC.It requires sophisticated instruments and suitable methods to obtain scintillation properties of the glasses in the fir... Purpose Glass is a potential choice for the scintillator in Hadronic calorimetry(HCAL)of the CEPC.It requires sophisticated instruments and suitable methods to obtain scintillation properties of the glasses in the first time.It is necessary to establish an evaluation method for nuclear radiation detection performance of glass scintillator.Methods The spectroscopy research of the glass includes transmission/absorption spectrum and emission spectrum.The time characteristics include rise time,scintillation decay time and afterglow.The scintillation properties include light yield,energy resolution and minimum ionizing particle(MIP)response.And a new method for measuring the low light yield of glass scintillators is proposed.Results We have built a complete performance test system and evaluation method,which can evaluate the nuclear radiation detection performance of different glass scintillators.Conclusion By continuously improving the composition and preparation process of the glass,it can provide potential possibilities for the application in the high-energy physics experiment and nuclear radiation detection fields. 展开更多
关键词 CEPC Calorimeter Glass scintillator Scintillation Nuclear radiation detection
原文传递
Realization of an integrated seeding and compensating potato planter based on one-way clutch 被引量:5
12
作者 Guanping Wang Wei Sun +5 位作者 Lea-Der Chen Hua Zhang Xiaolong Liu Hongling Li Xiaoping Yang Hao Yang 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第3期79-87,共9页
The yield reduction caused by miss-seeding in potato mechanized sowing is astonishing.The existing research always needs to install a spare compensator on the original seed-metering device.Therefore,problems of comple... The yield reduction caused by miss-seeding in potato mechanized sowing is astonishing.The existing research always needs to install a spare compensator on the original seed-metering device.Therefore,problems of complex planter structure and compensated potato seed poor landing accuracy need to be solved urgently.Consequently,a scheme of integrated seeding and compensating potato planter based on one-way clutch is proposed in this paper.Based on a basic‘improved one raw potato planter’and the working principle of one-way clutch,power of seed-metering system is provided through main power transmission one-way clutch by land wheels when the system works properly.However,when miss-seeding detection system with infrared radiation deciding that a miss-seeding incident has happened,the seed-metering power will be replaced by a compensatory motor through compensating one-way clutch at a higher speed.Thus,the idea of catching-up compensation can be realized.After compensation is completed,the system controller disconnects the compensatory motor,and the seed-metering power will naturally switch to the land wheels again.A prototype based on this idea was built.Field tests showed that the accuracy of seed monitoring system is more than 99.9%;the adoption of catching-up compensation scheme does not bring about empty spoon rate rise significantly.Within the range of 0.2-0.8 m/s of the seed-metering chain speed,although the average success compensation rate decreases evidently with the increase of the chain speed,the success compensation rate is still near 70%even at 0.8 m/s,the vast majority of missed seeds can be compensated effectively. 展开更多
关键词 potato planter infrared radiation miss-seeding detection one-way clutch catching-up compensation
原文传递
Thermal experiment of silicon PIN detector
13
作者 陈鸿飞 邹积清 +3 位作者 施伟红 邹鸿 胡然生 田大宇 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第10期820-824,共5页
The experiment of this paper is the thermal test of the leakage current of silicon PIN detector. Raising temperature may cause the detector to increase leakage current, decrease depletion and increase noise. Three sam... The experiment of this paper is the thermal test of the leakage current of silicon PIN detector. Raising temperature may cause the detector to increase leakage current, decrease depletion and increase noise. Three samples are used in the experiment. One (called △E) is the sample of 100 μm in thickness. The other two (called E1 and E2) are stacks of five detectors of 1000 μm in thickness. All of them are 12 mm in diameter. The experiment has been done for 21 hours and with power on continuously. The samples have undergone more than 60 ℃ for about one hour. They are not degenerated when back to the room temperature. The depletion rate is temperature and bias voltage related. With the circuit of the experiment and temperature at 35 ℃, △E is still depleted while E1 and E2 are 94.9% and 99.7% depleted respectively. The noises of the samples can be derived from the values at room temperature and the thermal dependence of the leakage currents. With the addition of the noise of the pre-amplifier, the noises of E1, E2 and △E at 24 ℃ are 16.4, 16.3, and 10.5 keV (FWHM) respectively while at 35 ℃ are about 33.6, 33.1, and 20.6 keV (FWHM) respectively. 展开更多
关键词 thermal effects PIN detector radiation detection energetic particle space environment
原文传递
Anomalous self-optimization of sulfate ions for boosted oxygen evolution reaction 被引量:1
14
作者 Dengfeng Cao Oyawale Adetunji Moses +16 位作者 Beibei Sheng Shuangming Chen Haibin Pan Lihui Wu Hongwei Shou Wenjie Xu Dongdong Li Lirong Zheng Shengqi Chu Chuansheng Hu Daobin Liu Shiqiang Wei Xusheng Zheng Zeming Qi Xiaojun Wu Jing Zhang Li Song 《Science Bulletin》 SCIE EI CSCD 2021年第6期553-561,M0003,共10页
Broadly,the oxygen evolution reaction(OER)has been deeply understood as a significant part of energy conversion and storage.Nevertheless,the anions in the OER catalysts have been neglected for various reasons such as ... Broadly,the oxygen evolution reaction(OER)has been deeply understood as a significant part of energy conversion and storage.Nevertheless,the anions in the OER catalysts have been neglected for various reasons such as inactive sites,dissolution,and oxidation,amongst others.Herein,we applied a model catalyst s-Ni(OH)2 to track the anionic behavior in the catalyst during the electrochemical process to fill this gap.The advanced operando synchrotron radiation Fourier transform infrared(SR-FTIR)spectroscopy,synchrotron radiation photoelectron spectroscopy(SRPES)depth detection and differential X-ray absorption fine structure(D-XAFS)spectrum jointly point out that some oxidized sulfur species(SO_(4)^(2-))will selfoptimize new Ni–S bonds during OER process.Such amazing anionic self-optimization(ASO)behavior has never been observed in the OER process.Subsequently,the optimization-derived component shows a significantly improved electrocatalytic performance(activity,stability,etc.)compared to reference catalyst Ni(OH)_(2).Theoretical calculation further suggests that the ASO process indeed derives a thermodynamically stable structure of the OER catalyst,and then gives its superb catalytic performance by optimizing the thermodynamic and kinetic processes in the OER,respectively.This work demonstrates the vital role of anions in the electrochemical process,which will open up new perspectives for understanding OER and provide some new ideas in related fields(especially catalysis and chemistry). 展开更多
关键词 Oxygen evolution reaction(OER) Operando synchrotron radiation Fourier transform infrared(SR-FTIR)spectroscopy Synchrotron radiation photoelectron spectroscopy(SRPES)depth detection Differential X-ray absorption fine structure(D-XAFS)spectrum Anionic self-optimization(ASO)
原文传递
Correcting for spatially dependent intrinsic efficiency on a germanium double-sided strip detector to improve nuclear forensics response
15
作者 Timothy Jacomb-Hood James Fast Craig 《Radiation Detection Technology and Methods》 CSCD 2022年第1期78-87,共10页
Purpose The Germanium Gamma-ray Imager(GeGI)is a planar high-purity germanium(HPGe)imaging detector developed by PHDS Co for far-field imaging.This research investigates the detector’s ability for measuring heterogen... Purpose The Germanium Gamma-ray Imager(GeGI)is a planar high-purity germanium(HPGe)imaging detector developed by PHDS Co for far-field imaging.This research investigates the detector’s ability for measuring heterogeneous sources in the near field,placed directly on the detector’s faceplate,to perform isotopic mapping for nuclear forensic missions.Methods The intrinsic efficiency is strongly dependent on where the photons interact within the germanium.The efficiency varies by up to 20%within the sensitive volume of the detector.The efficiency was mapped using eight different photons from 123 to 1274 keV emitted from a collimated 154Eu photons.These were measured at 108 locations to interpolate the efficiency at any point on the detector’s face.Results The position and energy dependence are uncorrelated,and thus,the absolute efficiency at any position and for any gamma-ray energy can be calculated by the convolution of the spatial and energy efficiencies.Conclusion The results on this research show that detection efficiency for a planar two-sided strip HPGe is spatially dependent and shows typical energy dependence.The spatial dependence,which does not have any additional energy dependence,can be corrected.A 154Eu source was used in this research and was able to spatially calibrate for photon energies ranging from 100 to 1300 keV.This method is applicable for sources with higher gamma energies.The advantages of the method demonstrated that after initial in-laboratory calibration,a single measurement in the field can be used to efficiently calibrate the HPGe as a function of photon interaction on the crystal. 展开更多
关键词 Nuclear forensics radiation detection Gamma-ray imaging
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部