期刊文献+
共找到94篇文章
< 1 2 5 >
每页显示 20 50 100
Real-time and high-transmission middle-infrared optical imaging system based on a pixel-wise metasurface micro-polarization array
1
作者 马丽凤 杜杉 +6 位作者 常军 陈蔚霖 武楚晗 石鑫鑫 黄翼 钟乐 穆全全 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期304-309,共6页
Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following pro... Real-time polarization medium-wave infrared(MIR)optical imaging systems enable the acquisition of infrared and polarization information for a target.At present,real-time polarization MIR devices face the following problems:poor real-time performance,low transmission and high requirements for fabrication and integration.Herein,we aim to improve the performance of real-time polarization imaging systems in the MIR waveband and solve the above-mentioned defects.Therefore,we propose a MIR polarization imaging system to achieve real-time polarization-modulated imaging with high transmission as well as improved performance based on a pixel-wise metasurface micro-polarization array(PMMPA).The PMMPA element comprises several linear polarization(LP)filters with different polarization angles.The optimization results demonstrate that the transmittance of the center field of view for the LP filters is up to 77%at a wavelength of4.0μm and an extinction ratio of 88 d B.In addition,a near-diffraction-limited real-time MIR imaging optical system is designed with a field of view of 5°and an F-number of 2.The simulation results show that an MIR polarization imaging system with excellent real-time performance and high transmission is achieved by using the optimized PMMPA element.Therefore,the method is compatible with the available optical system design technologies and provides a way to realize real-time polarization imaging in MIR wavebands. 展开更多
关键词 real-time middle infrared optical imaging system metasurface polarization array
下载PDF
A fast and adaptive method for automatic weld defect detection in various real-time X-ray imaging systems 被引量:10
2
作者 邵家鑫 都东 +2 位作者 石涵 常保华 郭桂林 《China Welding》 EI CAS 2012年第1期8-12,共5页
A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of me... A first and effective method is proposed to detect weld deject adaptively in various Dypes of real-time X-ray images obtained in different conditions. After weld extraction and noise reduction, a proper template of median filter is used to estimate the weld background. After the weld background is subtracted from the original image, an adaptite threshold segmentation algorithm is proposed to obtain the binary image, and then the morphological close and open operation, labeling algorithm and fids'e alarm eliminating algorithm are applied to pracess the binary image to obtain the defect, ct detection result. At last, a fast realization procedure jbr proposed method is developed. The proposed method is tested in real-time X-ray image,s obtairted in different X-ray imaging sutems. Experiment results show that the proposed method is effective to detect low contrast weld dejects with few .false alarms and is adaptive to various types of real-time X-ray imaging systems. 展开更多
关键词 non-destructive testing real-time X-ray imaging weld defect automatie detection
下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
3
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color Doppler flow imaging aortic regurgitation
下载PDF
Feasibility of real-time magnetic resonance imaging-guided endomyocardial biopsies:An in-vitro study
4
作者 Dirk Lossnitzer Sebastian A Seitz +5 位作者 Birgit Krautz Bernhard Schnackenburg Florian André Grigorios Korosoglou Hugo A Katus Henning Steen 《World Journal of Cardiology》 CAS 2015年第7期415-422,共8页
AIM: To investigate if magnetic resonance(MR)-guided biopsy can improve the performance and safety of such procedures. METHODS: A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5... AIM: To investigate if magnetic resonance(MR)-guided biopsy can improve the performance and safety of such procedures. METHODS: A novel MR-compatible bioptome was evaluated in a series of in-vitro experiments in a 1.5T magnetic resonance imaging(MRI) system. The bioptome was inserted into explanted porcine and bovine hearts under real-time MR-guidance employing a steady state free precession sequence. The artifact produced by the metal element at the tip and the signal voids caused by the bioptome were visually tracked for navigation and allowed its constant and precise localization. RESULTS: Cardiac structural elements and the target regions for the biopsy were clearly visible. Our method allowed a significantly better spatial visualization of the bioptoms tip compared to conventional X-ray guidance. The specific device design of the bioptome avoided inducible currents and therefore subsequent heating. The novel MR-compatible bioptome provided a superior cardiovascular magnetic resonance(imaging) soft-tissue visualization for MR-guided myocardial biopsies. Not at least the use of MRI guidance for endomyocardial biopsies completely avoided radiation exposure for both patients and interventionalists.CONCLUSION: MRI-guided endomyocardial biopsies provide a better than conventional X-ray guided navigation and could therefore improve the specificity and reproducibility of cardiac biopsies in future studies. 展开更多
关键词 Endomyocardial biopsy Cardiovascular MAGNETIC resonance(imaging) MAGNETIC RESONANCE imaging-guided interventions real-time imaging
下载PDF
DEVELOPMENT OF AN AIRBORNE SAR REAL-TIME DIGITAL IMAGING PROCESSOR
5
作者 Zhu Xixing Jin Lingjiao Huang Ling(institute of Electronics, Academia Sinica, Beijing 100080) 《Journal of Electronics(China)》 1996年第2期116-121,共6页
An airborne SAR real-time digital imaging processor is presented, and its realtime digital imaging principle and main technical parameters are analyzed briefly. The system configuration and logical structure are descr... An airborne SAR real-time digital imaging processor is presented, and its realtime digital imaging principle and main technical parameters are analyzed briefly. The system configuration and logical structure are described in detail. Finally the main features of this system and examples of imagery obtained with the system are also presented. 展开更多
关键词 SAR real-time imaging PROCESSOR MULTIPROCESSOR operation system
下载PDF
Real-time image processing and display in object size detection based on VC++ 被引量:2
6
作者 翟亚宇 潘晋孝 +1 位作者 刘宾 陈平 《Journal of Measurement Science and Instrumentation》 CAS 2014年第4期40-45,共6页
Real-time detection for object size has now become a hot topic in the testing field and image processing is the core algorithm. This paper focuses on the processing and display of the collected dynamic images to achie... Real-time detection for object size has now become a hot topic in the testing field and image processing is the core algorithm. This paper focuses on the processing and display of the collected dynamic images to achieve a real-time image pro- cessing for the moving objects. Firstly, the median filtering, gain calibration, image segmentation, image binarization, cor- ner detection and edge fitting are employed to process the images of the moving objects to make the image close to the real object. Then, the processed images are simultaneously displayed on a real-time basis to make it easier to analyze, understand and identify them, and thus it reduces the computation complexity. Finally, human-computer interaction (HCI)-friendly in- terface based on VC ++ is designed to accomplish the digital logic transform, image processing and real-time display of the objects. The experiment shows that the proposed algorithm and software design have better real-time performance and accu- racy which can meet the industrial needs. 展开更多
关键词 size detection real-time image processing and display gain calibration edge fitting
下载PDF
A new imaging mode based on X-ray CT as prior image and sparsely sampled projections for rapid clinical proton CT 被引量:1
7
作者 Yu-Qing Yang Wen-Cheng Fang +4 位作者 Xiao-Xia Huang Qiang Du Ming Li Jian Zheng Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期64-74,共11页
Proton computed tomography(CT)has a distinct practical significance in clinical applications.It eliminates 3–5%errors caused by the transformation of Hounsfield unit(HU)to relative stopping power(RSP)values when usin... Proton computed tomography(CT)has a distinct practical significance in clinical applications.It eliminates 3–5%errors caused by the transformation of Hounsfield unit(HU)to relative stopping power(RSP)values when using X-ray CT for positioning and treatment planning systems(TPSs).Following the development of FLASH proton therapy,there are increased requirements for accurate and rapid positioning in TPSs.Thus,a new rapid proton CT imaging mode is proposed based on sparsely sampled projections.The proton beam was boosted to 350 MeV by a compact proton linear accelerator(LINAC).In this study,the comparisons of the proton scattering with the energy of 350 MeV and 230 MeV are conducted based on GEANT4 simulations.As the sparsely sampled information associated with beam acquisitions at 12 angles is not enough for reconstruction,X-ray CT is used as a prior image.The RSP map generated by converting the X-ray CT was constructed based on Monte Carlo simulations.Considering the estimation of the most likely path(MLP),the prior image-constrained compressed sensing(PICCS)algorithm is used to reconstruct images from two different phantoms using sparse proton projections of 350 MeV parallel proton beam.The results show that it is feasible to realize the proton image reconstruction with the rapid proton CT imaging proposed in this paper.It can produce RSP maps with much higher accuracy for TPSs and fast positioning to achieve ultra-fast imaging for real-time image-guided radiotherapy(IGRT)in clinical proton therapy applications. 展开更多
关键词 Proton CT real-time image guidance image reconstruction Proton therapy
下载PDF
A Flexible DSP-Based Network forReal-Time Image-Processing 被引量:5
8
作者 MAOHai-cen ZHANGTian-xu JIANGHao-yang WANGYue-huan 《Wuhan University Journal of Natural Sciences》 CAS 2004年第6期921-926,共6页
This paper proposed a general purpose real-time image processing system based on a flexible DSP-based Network, which is implemented by a high bandwidth communication channel, links. The links is realized using FPGA an... This paper proposed a general purpose real-time image processing system based on a flexible DSP-based Network, which is implemented by a high bandwidth communication channel, links. The links is realized using FPGA and provides a bandwidth of 12. 8 Gbit/s. Using the links, The topologic of multi-DSP system can be changed online to meet the variabilities of the parallel algorithm of image processing. The system can be assembled with utmost tens of boards and maintain the high communication speed. Analysis of the system adaptivity to image processing is testified followed by actual results. Key words real-time image processing - multi-DSP - flexible - scalable - FPGA - links CLC number TP 303 Foundation item: Supported by the National Natural Science Foundation of China (60135020)Biography: MAO Hai-cen(1973-), male, Ph.D. candidate, research direction: artificial intelligence, expert system, pattern recognition and image processing 展开更多
关键词 real-time image processing MULTI-DSP FLEXIBLE SCALABLE FPGA LINKS
下载PDF
New multi-DSP parallel computing architecture for real-time image processing 被引量:4
9
作者 Hu Junhong Zhang Tianxu Jiang Haoyang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2006年第4期883-889,共7页
The flexibility of traditional image processing system is limited because those system are designed for specific applications. In this paper, a new TMS320C64x-based multi-DSP parallel computing architecture is present... The flexibility of traditional image processing system is limited because those system are designed for specific applications. In this paper, a new TMS320C64x-based multi-DSP parallel computing architecture is presented. It has many promising characteristics such as powerful computing capability, broad I/O bandwidth, topology flexibility, and expansibility. The parallel system performance is evaluated by practical experiment. 展开更多
关键词 parallel computing image processing real-time computer architecture
下载PDF
Heterogeneity induced strain localization in block-in-matrix-soils subjected to uniaxial loading using real-time CT scanning
10
作者 Yanfang Wu Xiao Li +5 位作者 Luqing Zhang Shengwen Qi Jian Zhou Jianming He Zhaobin Zhang Xiukuo Sun 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第8期1951-1959,共9页
Block-in-matrix-soils(bimsoils)are geological mixtures that have distinct structures consisting of relatively strong rock blocks and weak matrix soils.It is still a challenge to evaluate the mechanical behaviors of bi... Block-in-matrix-soils(bimsoils)are geological mixtures that have distinct structures consisting of relatively strong rock blocks and weak matrix soils.It is still a challenge to evaluate the mechanical behaviors of bimsoils because of the heterogeneity,chaotic structure,and lithological variability.As a result,only very limited laboratory studies have been reported on the evolution of their internal deformation.In this study,the deformation evolution of bimsoils under uniaxial loading is investigated using real-time X-ray computed tomography(CT)and image correlation algorithm(with a rock block percentage(RBP)of 40%).Three parameters,i.e.heterogeneity coefficient(K),correlation coefficient(CC),and standard deviation(STD)of displacement fields,are proposed to quantify the heterogeneity of the motion of the rock blocks and the progressive deformation of the bimsoils.Experimental results show that the rock blocks in bimsoils are prone to forming clusters with increasing loading,and the sliding surface goes around only one side of a cluster.Based on the movement of the rock blocks recorded by STD and CC,the progressive deformation of the bimsoils is quantitatively divided into three stages:initialization of the rotation of rock blocks,formation of rock block clusters,and formation of a shear band by rock blocks with significant rotation.Moreover,the experimental results demonstrate that the meso-motion of rock blocks controls the macroscopic mechanical properties of the samples. 展开更多
关键词 image correlation algorithm Damage processing real-time computed tomography(CT) imaging Rock block motion Uniaxial compression
下载PDF
A Practical Study of Intelligent Image-Based Mobile Robot for Tracking Colored Objects
11
作者 Mofadal Alymani Mohamed Esmail Karar Hazem Ibrahim Shehata 《Computers, Materials & Continua》 SCIE EI 2024年第8期2181-2197,共17页
Object tracking is one of the major tasks for mobile robots in many real-world applications.Also,artificial intelligence and automatic control techniques play an important role in enhancing the performance of mobile r... Object tracking is one of the major tasks for mobile robots in many real-world applications.Also,artificial intelligence and automatic control techniques play an important role in enhancing the performance of mobile robot navigation.In contrast to previous simulation studies,this paper presents a new intelligent mobile robot for accomplishing multi-tasks by tracking red-green-blue(RGB)colored objects in a real experimental field.Moreover,a practical smart controller is developed based on adaptive fuzzy logic and custom proportional-integral-derivative(PID)schemes to achieve accurate tracking results,considering robot command delay and tolerance errors.The design of developed controllers implies some motion rules to mimic the knowledge of experienced operators.Twelve scenarios of three colored object combinations have been successfully tested and evaluated by using the developed controlled image-based robot tracker.Classical PID control failed to handle some tracking scenarios in this study.The proposed adaptive fuzzy PID control achieved the best accurate results with the minimum average final error of 13.8 cm to reach the colored targets,while our designed custom PID control is efficient in saving both average time and traveling distance of 6.6 s and 14.3 cm,respectively.These promising results demonstrate the feasibility of applying our developed image-based robotic system in a colored object-tracking environment to reduce human workloads. 展开更多
关键词 Mobile robot autonomous systems fuzzy logic control real-time image processing
下载PDF
High performance reconfigurable hardware system for real-time image processing
12
作者 赵广州 张天序 +2 位作者 王岳环 曹治国 左峥嵘 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2005年第3期502-509,共8页
A novel reconfigurable hardware system which uses both muhi-DSP and FPGA to attain high performance and real-time image processing are presented. The system structure and working principle of mainly processing multi-B... A novel reconfigurable hardware system which uses both muhi-DSP and FPGA to attain high performance and real-time image processing are presented. The system structure and working principle of mainly processing multi-BSP board, extended multi-DSP board are analysed. The outstanding advantage is that the communication among different board components of this system is supported by high speed link ports & serial ports for increasing the system performance and computational power. Then the implementation of embedded real-time operating systems (RTOS) by us is discussed in detail. In this system, we adopt two kinds of parallel structures controlled by RTOS for parallel processing of algorithms. The experimental results show that exploitive period of the system is short, and maintenance convenient. Thus it is suitable for real-time image processing and can get satisfactory effect of image recognition. 展开更多
关键词 MULTI-DSP fidd programmable gate arrays real-time image processing real time operating systems parallel structure.
下载PDF
Real-time parameters monitoring system for underground equipment based on panoramic images
13
作者 Chen-guang ZHAO Bo-qiang SHI Zhi-jun HAO Ming-chong XU Chen-tong BIAN 《Journal of Coal Science & Engineering(China)》 2013年第1期109-112,共4页
Complex terrain and working equipment in coal mine underground need a way to ensure coal mine safety. In this paper, the way to monitor the real-time status of underground equipment was put forward, and it was proved ... Complex terrain and working equipment in coal mine underground need a way to ensure coal mine safety. In this paper, the way to monitor the real-time status of underground equipment was put forward, and it was proved to be effective as commanding and dispatching system. Monitoring system for underground equipment based on panoramic images was effectively combined with real-time sensor data and static panoramic images of underground surrounding, which not only realizes real-time status monitoring for underground equipment, but also gets a direct scene for underground surrounding. B/S mode was applied in the monitoring system and this is convenient for users to monitor the equipment. Meantime, it can reduce the waste of the data resource. 展开更多
关键词 panoramic images underground equipment real-time parameters MONITOR B/S mode
下载PDF
An FPGA-based real-time image processing system
14
作者 ZONG Dexiang HE Yonghui 《Baosteel Technical Research》 CAS 2013年第4期8-10,共3页
This paper analyzes the current difficulties encountered in on-line inspection systems of strip surface quality, specifically relating to problems with real-time processing of huge amounts of data. To address this nee... This paper analyzes the current difficulties encountered in on-line inspection systems of strip surface quality, specifically relating to problems with real-time processing of huge amounts of data. To address this need, this paper describes an FPGA-based high-speed image processing module with both hardware and software aspects. Improving these two aspects together will help the system achieve real-time processing of massive image data, and simplifies the architecture of the strip surface quality on-line inspection system. 展开更多
关键词 real-time image processing FPGA strip surface quality on-line inspection system
下载PDF
Image Fusion Real-time System Based on FPGA and Multi-DSP
15
作者 Feng Qu Bochao Liu +1 位作者 Jian Zhao Qiang Sun 《Optics and Photonics Journal》 2013年第2期76-78,共3页
In order to solve complex algorithm that is difficult to achieve real-time processing of Multiband image fusion within large amount of data, a real-time image fusion system based on FPGA and multi-DSP is designed. Fiv... In order to solve complex algorithm that is difficult to achieve real-time processing of Multiband image fusion within large amount of data, a real-time image fusion system based on FPGA and multi-DSP is designed. Five-band image acquisition, image registration, image fusion and display output can be done within the system which uses FPGA as the main processor and the other three DSP as an algorithm processor. Making full use of Flexible and high-speed characteristics of FPGA, while an image fusion algorithm based on multi-wavelet transform is optimized and applied to the system. The final experimental results show that the frame rate of 15 Hz, with a resolution of 1392 × 1040 of the five-band image can be used by the system to complete processing within 41ms. 展开更多
关键词 MULTI-BAND real-time imagE Fusion Multi-wavelet TRANSFORM imagE REGISTRATION
下载PDF
Emotionally Resonant Branding: The Role of AI in Synthesising Dynamic Brand Images for Artists in the Music Industry
16
作者 Kaveen Prabodhya Thivanka Liyanage Weliweriya Liyanage Himendra Balalle 《Open Journal of Applied Sciences》 2024年第9期2661-2678,共18页
Artificial Intelligence (AI) expands its recognition rapidly through the past few years in the context of generating content dynamically, remarkably challenging the human creativity. This study aims to evaluate the ef... Artificial Intelligence (AI) expands its recognition rapidly through the past few years in the context of generating content dynamically, remarkably challenging the human creativity. This study aims to evaluate the efficacy of AI in enhancing personal branding for musicians, particularly in crafting brand images based on emotions received from the artist’s music will improve the audience perceptions regarding the artist’s brand. Study used a quantitative approach for the research, gathering primary data from the survey of 191 people—music lovers, musicians and music producers. The survey focuses on preferences, perceptions, and behaviours related to music consumption and artist branding. The study results demonstrate the awareness and understanding of AI’s role in personal branding within the music industry. Also, results indicate that such an adaptive approach enhances audience perceptions of the artist and strengthens emotional connections. Furthermore, over 50% of the participants indicated a desire to attend live events where an artist’s brand image adapts dynamically to their emotions. The study focuses on novel approaches in personal branding based on the interaction of AI-driven emotional data. In contrast to traditional branding concepts, this study indicates that AI can suggest dynamic and emotionally resonant brand identities for artists. The real time audience response gives proper guidance for the decision-making. This study enriches the knowledge of AI’s applicability to branding processes in the context of the music industry and opens the possibilities for additional advancements in building emotionally appealing brand identities. 展开更多
关键词 Artificial Intelligence Emotional Branding Personal Branding Music Industry Dynamic Brand image Audience Perception Machine Learning real-time Emotional Responses
下载PDF
Application of A* Algorithm for Real-time Path Re-planning of an Unmanned Surface Vehicle Avoiding Underwater Obstacles 被引量:8
17
作者 Thanapong Phanthong Toshihiro Maki +2 位作者 Tamaki Ura Takashi Sakamaki Pattara Aiyarak 《Journal of Marine Science and Application》 2014年第1期105-116,共12页
This paper describes path re-planning techniques and underwater obstacle avoidance for unmanned surface vehicle(USV) based on multi-beam forward looking sonar(FLS). Near-optimal paths in static and dynamic environment... This paper describes path re-planning techniques and underwater obstacle avoidance for unmanned surface vehicle(USV) based on multi-beam forward looking sonar(FLS). Near-optimal paths in static and dynamic environments with underwater obstacles are computed using a numerical solution procedure based on an A* algorithm. The USV is modeled with a circular shape in 2 degrees of freedom(surge and yaw). In this paper, two-dimensional(2-D) underwater obstacle avoidance and the robust real-time path re-planning technique for actual USV using multi-beam FLS are developed. Our real-time path re-planning algorithm has been tested to regenerate the optimal path for several updated frames in the field of view of the sonar with a proper update frequency of the FLS. The performance of the proposed method was verified through simulations, and sea experiments. For simulations, the USV model can avoid both a single stationary obstacle, multiple stationary obstacles and moving obstacles with the near-optimal trajectory that are performed both in the vehicle and the world reference frame. For sea experiments, the proposed method for an underwater obstacle avoidance system is implemented with a USV test platform. The actual USV is automatically controlled and succeeded in its real-time avoidance against the stationary undersea obstacle in the field of view of the FLS together with the Global Positioning System(GPS) of the USV. 展开更多
关键词 UNDERWATER OBSTACLE AVOIDANCE real-time pathre-planning A* ALGORITHM SONAR image unmanned surface vehicle
下载PDF
State-of-the-art imaging techniques in endoscopic ultrasound 被引量:5
18
作者 Adrian Sftoiu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第6期691-696,共6页
Endoscopic ultrasound (EUS) has recently evolved through technological improvement of equipment,with a major clinical impact in digestive and mediastinal diseases.State-of-the-art EUS equipment now includes real-time ... Endoscopic ultrasound (EUS) has recently evolved through technological improvement of equipment,with a major clinical impact in digestive and mediastinal diseases.State-of-the-art EUS equipment now includes real-time sono-elastography,which might be useful for a better characterization of lesions and increased accuracy of differential diagnosis (for e.g.lymph nodes or focal pancreatic lesions).Contrast-enhanced EUS imaging is also available,and is already being used for the differential diagnosis of focal pancreatic masses.The recent development of low mechanical index contrast harmonic EUS imaging offers hope for improved diagnosis,staging and monitoring of anti-angiogenic treatment.Tridimensional EUS (3D-EUS) techniques can be applied to enhance the spatial understanding of EUS anatomy,especially for improved staging of tumors,obtained through a better assessment of the relationship with major surrounding vessels.Despite the progress gained through all these imaging techniques,they cannot replace cytological or histological diagnosis.However,real-time optical histological diagnosis can be achieved through the use of single-fiber confocal laser endomicroscopy techniques placed under real-time EUS-guidance through a 22G needle.Last,but not least,EUS-assisted natural orifice transluminal endoscopic surgery (NOTES) procedures offer a whole new area of imaging applications,used either for combination of NOTES peritoneoscopy and intraperitoneal EUS,but also for access of retroperitoneal organs through posterior EUS guidance. 展开更多
关键词 Endoscopic ultrasound real-time sono-elastography CONTRAST-ENHANCEMENT Tridimensional (3D) Hybrid imaging Endoscopic ultrasound-guided fine needle aspiration
下载PDF
Real-time histology with the endocytoscope 被引量:3
19
作者 Rajvinder Singh Swee Lin Chen Yi Mei +2 位作者 William Tam Devinder Raju Andrew Ruszkiewicz 《World Journal of Gastroenterology》 SCIE CAS CSCD 2010年第40期5016-5019,共4页
Endoscopic Imaging has progressed tremendously over the last few decades. Novel imaging technologies such as high-resolution and high-magnification white light endoscopy, narrow band imaging, optimal band imaging, aut... Endoscopic Imaging has progressed tremendously over the last few decades. Novel imaging technologies such as high-resolution and high-magnification white light endoscopy, narrow band imaging, optimal band imaging, auto? ourescence imaging and optical coherence tomography not only aid the endoscopist in detecting malignant or pre-malignant lesions but also assist in predicting histology. Recently, the introduction of Endocytoscopy (EC) and Confocal Endomicroscopy has taken us into a new realm of diagnostic endoscopy. With the ability to magnify up to 1000 ×, cellular structures can be visualized in real-time. This advance in technology could potentially lead to a paradigm shift negating the need to obtain biopsies. EC is, however, still in the early stages of development and further research needs to be carried out before it can be accepted as standard practice. This review will focus on the diagnostic utility of the Endocytoscope. 展开更多
关键词 ENDOCYTOSCOPY Advanced endoscopy imaging Magnification endoscopy real-time histology
下载PDF
Real-time virtual sonography visualization and its clinical application in biliopancreatic disease 被引量:1
20
作者 Atsushi Sofuni Takao Itoi +11 位作者 Fumihide Itokawa Takayoshi Tsuchiya Toshio Kurihara Kentaro Ishii Syujiro Tsuji Nobuhito Ikeuchi Reina Tanaka Junko Umeda Ryosuke Tonozuka Mitsuyoshi Honjo Shuntaro Mukai Fuminori Moriyasu 《World Journal of Gastroenterology》 SCIE CAS 2013年第42期7419-7425,共7页
AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasou... AIM:To evaluate the usefulness of real-time virtual sonography(RVS)in biliary and pancreatic diseases.METHODS:This study included 15 patients with biliary and pancreatic diseases.RVS can be used to observe an ultrasound image in real time by merging the ultrasound image with a multiplanar reconstruction computed tomography(CT)image,using pre-scanned CT volume data.The ultrasound used was EUB-8500with a convex probe EUP-C514.The RVS images were evaluated based on 3 levels,namely,excellent,good and poor,by the displacement in position.RESULTS:By combining the objectivity of CT with free scanning using RVS,it was possible to easily interpret the relationship between lesions and the surrounding organs as well as the position of vascular structures.The resulting evaluation levels of the RVS images were12 excellent(pancreatic cancer,bile duct cancer,cholecystolithiasis and cholangiocellular carcinoma)and 3 good(pancreatic cancer and gallbladder cancer).Compared with conventional B-mode ultrasonography and CT,RVS images achieved a rate of 80%superior visualization and 20%better visualization.CONCLUSION:RVS has potential usefulness in objective visualization and diagnosis in the field of biliary and pancreatic diseases. 展开更多
关键词 BILIARY and pancreatic disease COMPUTED tomography-multiplanar reconstruction imagE Navigation real-time ultrasound imagE real-time VIRTUAL SONOGRAPHY
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部