A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculatio...A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculation and validation of the response matrix, are presented. The PFNS for ^235U in the energy range 1–12 MeV, induced by thermal neutrons, was obtained. The measured spectrum in the low-energy region was in good agreement with previous work and the ENDF/B-VII library, except for minor differences. In the high-energy region, however, the relative height of the measured spectrum was greater, and an analysis of the experiment indicated uncertainties of 13% at 10 MeV and 24% at 12 MeV. Experimental results showed that the recoil proton method could be used to measure prompt fission neutron spectra. Some directions for future work are included.展开更多
A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to th...A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to the neutron energy spectrum is investigated. The response matrices R of the polyethylene film at angles of 0o and45o were obtained by simulating the recoil proton energy spectra from mono-energetic neutrons using the MCNPX code. With an assumed D-T neutron spectrum, the recoil proton spectra from the polyethylene film at angles of 0oand 45owere also simulated using the MCNPX code. Based on the response matrices R and the simulated recoil proton spectra at 0oand 45o, the respective unfolded neutron spectra were obtained using the iteration algorithm,and compared with the assumed neutron spectrum. The results show that the iteration algorithm method can be applied to unfold the recoil proton energy spectrum to the neutron energy spectrum for D-T neutron energy spectra measurement using the recoil proton method.展开更多
The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the respon...The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.展开更多
基金supported by the National Natural Science Foundation of China(No.11775196)the Chinese Special Project for ITER(No.2015GB108006)
文摘A measurement of the ^235U prompt fission neutron spectrum (PFNS) by the recoil proton method was performed at the Institute of Nuclear Physics and Chemistry, China. Details of the method, which include the calculation and validation of the response matrix, are presented. The PFNS for ^235U in the energy range 1–12 MeV, induced by thermal neutrons, was obtained. The measured spectrum in the low-energy region was in good agreement with previous work and the ENDF/B-VII library, except for minor differences. In the high-energy region, however, the relative height of the measured spectrum was greater, and an analysis of the experiment indicated uncertainties of 13% at 10 MeV and 24% at 12 MeV. Experimental results showed that the recoil proton method could be used to measure prompt fission neutron spectra. Some directions for future work are included.
基金Supported by National Natural Science Foundations of China(11375077,21327801)National Key Scientific Instrument And Equipment Development Project(2013YQ40861)
文摘A proton recoil method for measuring D-T neutron energy spectra using polyethylene film and a Si(Au)surface barrier detector is presented. An iteration algorithm for unfolding the recoil proton energy spectrum to the neutron energy spectrum is investigated. The response matrices R of the polyethylene film at angles of 0o and45o were obtained by simulating the recoil proton energy spectra from mono-energetic neutrons using the MCNPX code. With an assumed D-T neutron spectrum, the recoil proton spectra from the polyethylene film at angles of 0oand 45owere also simulated using the MCNPX code. Based on the response matrices R and the simulated recoil proton spectra at 0oand 45o, the respective unfolded neutron spectra were obtained using the iteration algorithm,and compared with the assumed neutron spectrum. The results show that the iteration algorithm method can be applied to unfold the recoil proton energy spectrum to the neutron energy spectrum for D-T neutron energy spectra measurement using the recoil proton method.
文摘The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.