期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Effects of Span Length and Additional Structure on Flow-Induced Transverse Vibration Characteristic of a Cantilevered Rectangular Prism
1
作者 La Ode Ahmad Barata Takahiro Kiwata +1 位作者 Takaaki Kono Toshiyuki Ueno 《Journal of Flow Control, Measurement & Visualization》 2020年第3期102-120,共19页
We consider the effects of the aspect ratio L/H (where<em> L</em> is the length of a prism, and <em>H</em> is the height of a prism normal to the flow direction) and the size of additional stru... We consider the effects of the aspect ratio L/H (where<em> L</em> is the length of a prism, and <em>H</em> is the height of a prism normal to the flow direction) and the size of additional structures (which are a plate and a fin on the surface of a prism) on a vibration characteristic of a cantilevered rectangular prism. The present research is intended to support the analysis of energy harvesting research on the flow-induced vibration in water flow using a magnetostrictive phenomenon. The prisms are constructed from stainless steel and mounted elastically to a plate spring attached to the ceiling wall of the water tunnel. The prisms with aspect ratios of<em> L/H</em> ≥ 5 have reasonably identical vibration characteristics. However, the difference in the vibration characteristic appears distinctly on a rectangular prism with an aspect ratio of <em>L/H </em>= 2.5. The rectangular prism with an aspect ratio of <em>L/H</em> = 10 and a side ratio of <em>D/H</em> = 0.2 has a stable and large response amplitude and oscillates with a lower velocity. The length of the added plate and the size of the added fin influence the velocity of vibration onset. If the length of the added plate and fin size on the rectangular prism with <em>D/H</em> = 0.2 becomes large, the curve of the response amplitude shifts to that of the rectangular prism with <em>D/H</em>= 0.5. The response amplitude of the rectangular prism with/without plate or fin is found to be related to the second moment of area of the prism. 展开更多
关键词 Flow-Induced Vibration Cantilevered Rectangular Prism Aspect Ratio Stepped Prism Finned Prism Response Amplitude Resonant Reduced Velocity
下载PDF
Reduced thermal sensitivity of hybrid air-core photonic band-gap fiber ring resonator
2
作者 冯丽爽 王锴 +3 位作者 焦洪臣 王俊杰 刘丹妮 杨照华 《Optoelectronics Letters》 EI 2018年第1期17-20,共4页
A novel hybrid air-core photonic band-gap fiber(PBF) ring resonator with twin 90° polarization-axis rotated splices is proposed and demonstrated. Frist, we measure the temperature dependent birefringence coeffici... A novel hybrid air-core photonic band-gap fiber(PBF) ring resonator with twin 90° polarization-axis rotated splices is proposed and demonstrated. Frist, we measure the temperature dependent birefringence coefficient of air-core PBF and Panda fiber. Experimental results show that the relative temperature dependent birefringence coefficient of air-core PBF is 1.42×10^(-8)/℃, which is typically ~16 times less than that of Panda fiber. Then, we extract the geometry profile of air-core PBF from scanning electron microscope(SEM) images. Numerical modal is built to distinguish the fast axis and slow axis in the fiber. By precisely setting the length difference in air-core PBF and Panda fiber between two 90° polarization-axis rotated splicing points, the hybrid air-core PBF ring resonator is constructed, and the finesse of the resonator is 8.4. Environmental birefringence variation induced by temperature change can be well compensated, and experimental results show an 18-fold reduction in thermal sensitivity, compared with resonator with twin 0° polarization-axis rotated splices. 展开更多
关键词 Reduced thermal sensitivity of hybrid air-core photonic band-gap fiber ring resonator PBF
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部