MP-RAID: Mirroring and parity protected disk array 被引量:1
1
作者 毛波 冯丹 吴素贞 《Journal of Shanghai University(English Edition)》 CAS 2009年第6期444-449,共6页
Redundant array of inexpensive disk (RAID)10 is known as the most reliable disk array architecture to tolerate up to half of total disk failures, but failure of two disks in the same mirror set still results in data... Redundant array of inexpensive disk (RAID)10 is known as the most reliable disk array architecture to tolerate up to half of total disk failures, but failure of two disks in the same mirror set still results in data loss. In this paper, we propose a new disk array architecture, mirroring and parity protected RAID (MP-RAID), which combines both mirroring and parity techniques to further improve reliability of disk arrays. The main idea behind MP-RAID is to protect the data by both mirroring and parity techniques: keep two copies of data in the same mirror set and update the parity block in the log disk within the same parity groups. Reliability analysis shows that the reliability of MP-RAID, in terms of mean time to data loss (MTTDL), is much better than RAID10 and RAID5. 展开更多
关键词 storage systems redundant array of inexpensive disk (raid reliability analysis mean time to data loss (MTTDL)
下载PDF
A CASCADING LATIN SCHEME TO TOLERATE DOUBLE DISK FAILURES IN RAID ARCHITECTURES 被引量:1
2
作者 Lin Sheng Wang Gang Liu Xiaoguang Liu Jing 《Journal of Electronics(China)》 2010年第2期243-249,共7页
In recent years,a lot of XOR-based coding schemes have been developed to tolerate double disk failures in Redundant Array of Independent Disks (RAID) architectures,such as EVENODD-code,X-code,B-code and BG-HEDP. Despi... In recent years,a lot of XOR-based coding schemes have been developed to tolerate double disk failures in Redundant Array of Independent Disks (RAID) architectures,such as EVENODD-code,X-code,B-code and BG-HEDP. Despite those researches,the decades-old strategy of Reed-Solomon (RS) code remains the only popular space-optimal Maximum Distance Separable (MDS) code for all but the smallest storage systems. The reason is that all those XOR-based schemes are too difficult to be implemented,it mainly because the coding-circle of those codes vary with the number of disks. By contrast,the coding-circle of RS code is a constant. In order to solve this problem,we develop a new MDS code named Latin code and a cascading scheme based on Latin code. The cascading Latin scheme is a nearly MDS code (with only one or two more parity disks compared with the MDS ones). Nev-ertheless,it keeps the coding-circle of the basic Latin code (i.e. a constant) and the low encod-ing/decoding complexity similar to other parity array codes. 展开更多
关键词 2-erasure code redundant array of Independent disks (raid) Latin square
下载PDF
磁盘阵列RAID可靠性分析 被引量:24
3
作者 陈华英 《电子科技大学学报》 EI CAS CSCD 北大核心 2006年第3期403-405,共3页
介绍了磁盘阵列的基本概念和常用的磁盘阵列种类,分析了RAID0、RAID3和RAID10三种磁盘阵列的可靠性值,同时与实验数据进行了比较。结果表明,磁盘阵列的可靠性值基于标准模型在一定程度上可以进行量化,能进行科学的计算,得出RAID10比相... 介绍了磁盘阵列的基本概念和常用的磁盘阵列种类,分析了RAID0、RAID3和RAID10三种磁盘阵列的可靠性值,同时与实验数据进行了比较。结果表明,磁盘阵列的可靠性值基于标准模型在一定程度上可以进行量化,能进行科学的计算,得出RAID10比相应其他的RAID的容量更大,可靠性更佳。该文的可靠性分析对磁盘阵列的进一步研究和生产能起到现实的指导作用。 展开更多
关键词 磁盘阵列 可靠性 镜像 磁盘阵列控制器
下载PDF
基于双容错编码的DP-RAID数据布局研究 被引量:1
4
作者 刘卫平 蔡皖东 任建奇 《西北工业大学学报》 EI CAS CSCD 北大核心 2006年第2期219-223,共5页
基于单容错编码的数据布局已经不能满足存储系统对可靠性越来越高的要求,而现有的基于多容错编码的数据布局普遍存在编码解码复杂,计算负载大等缺点。文中设计了一种基于双奇偶校验的双容错数据布局DP-RA ID。该布局只需要在磁盘数量为... 基于单容错编码的数据布局已经不能满足存储系统对可靠性越来越高的要求,而现有的基于多容错编码的数据布局普遍存在编码解码复杂,计算负载大等缺点。文中设计了一种基于双奇偶校验的双容错数据布局DP-RA ID。该布局只需要在磁盘数量为素数的RA ID 5阵列系统中增加1个校验磁盘,通过水平和对角方向的双重奇偶校验实现双容错。该布局的双重校验条纹长度相同,结构简单,易于实现。而且该布局的编码解码算法简单,计算负载小。研究表明该布局与RA ID 5相比,写操作性能会有少许的下降,读操作性能不变,而可靠性大幅度提高。 展开更多
关键词 raid 奇偶校验 双容错编码 可靠性
下载PDF
自适应存储海量系统中的一种文件级可调整RAID 被引量:2
5
作者 赵振 谢长生 蒋思宇 《计算机工程与科学》 CSCD 2007年第9期150-152,F0003,共4页
如何在保证数据完整性和可用性的同时充分利用各存储结点的能力,并依据外部访问特征调整数据组织结构,是自适应海量存储系统的关键技术之一。针对该问题,本文提出一种文件级可调整RAID(RFRAID)结构。该结构在不中断服务的同时综合考虑... 如何在保证数据完整性和可用性的同时充分利用各存储结点的能力,并依据外部访问特征调整数据组织结构,是自适应海量存储系统的关键技术之一。针对该问题,本文提出一种文件级可调整RAID(RFRAID)结构。该结构在不中断服务的同时综合考虑各结点负载特征,以较少的数据迁移量进行平滑不间断的动态调整,使系统能够较好地适应外部访问特征。实验表明,该结构能够有效提高系统整体性能。 展开更多
关键词 自适应 可调整 海量存储系统 raid
下载PDF
基于单磁盘的RAID系统可靠性分析 被引量:2
6
作者 张都乐 祝怀杰 何淼 《计算机系统应用》 2014年第1期33-37,共5页
RAID系统具有高可靠性、高可扩展性和高性价比的特性,是当前解决信息系统外部存储的一种主要技术.随着该技术应用的普及以及系统规模的扩大,系统实效事件日益频繁,因此RAID系统的可靠性研究成为一个热点.简单介绍了RAID系统工作原理及... RAID系统具有高可靠性、高可扩展性和高性价比的特性,是当前解决信息系统外部存储的一种主要技术.随着该技术应用的普及以及系统规模的扩大,系统实效事件日益频繁,因此RAID系统的可靠性研究成为一个热点.简单介绍了RAID系统工作原理及其硬盘组合方式,从单个硬盘的可靠性出发,推导出RAID系统的可靠性数学模型,并进行了分析. 展开更多
关键词 独立磁盘冗余阵列 冗余技术 可靠性 数学模型
下载PDF
高速光纤通道技术在RAID系统中的应用 被引量:1
7
作者 韩德志 《微型电脑应用》 2000年第5期52-55,共4页
本文根据磁盘阵列的特点 ,提出了一种在磁盘阵列中使用高速光纤通道技术的新方法。
关键词 raid系统 磁盘阵列 光纤通道 硬盘驱动器
下载PDF
一种自适应的RAID系统的设计 被引量:5
8
作者 宗祥宇 李冀 +2 位作者 魏明亮 茅兵 谢立 《计算机工程与应用》 CSCD 北大核心 2002年第4期112-114,179,共4页
许多系统同时有处理多媒体数据和事务处理数据的需求,而单一的文件存储方式无法为二者同时提供高质量的服务。针对这一问题,文章提出了一种自适应的混合RAID体系结构:ARAID。在ARAID中,采用了一种自适应性算法动态地决定文件的存储方式... 许多系统同时有处理多媒体数据和事务处理数据的需求,而单一的文件存储方式无法为二者同时提供高质量的服务。针对这一问题,文章提出了一种自适应的混合RAID体系结构:ARAID。在ARAID中,采用了一种自适应性算法动态地决定文件的存储方式,将不同类型的文件分别存储在不同的RAID中,从而提高系统的性能,提供更高的事务处理率与更高的数据传输率。 展开更多
关键词 事务处理数据 多媒体数据 自适应 raid系统 存储器 磁盘阵列 计算机
下载PDF
BW-RAID系统的重构技术及优化研究 被引量:1
9
作者 韩超 那文武 +1 位作者 刘振军 许鲁 《计算机工程与应用》 CSCD 2012年第1期60-63,97,共5页
高效的重构技术可以有效地提高系统数据恢复时的性能,减少数据的恢复时间。针对BW-RAID系统的结构特点,提出了系统数据卷数据优先重构的机制和对已重构数据请求重定向的方法,有效地提高了系统数据恢复时的对外服务性能。基于上面的机制... 高效的重构技术可以有效地提高系统数据恢复时的性能,减少数据的恢复时间。针对BW-RAID系统的结构特点,提出了系统数据卷数据优先重构的机制和对已重构数据请求重定向的方法,有效地提高了系统数据恢复时的对外服务性能。基于上面的机制和方法,同时利用数据恢复时的用户负载特点,采用热点和缓存数据指导数据重构以及用户请求辅助数据重构两种策略,进一步地提高了数据恢复时的性能和重构效率。 展开更多
关键词 网络存储 冗余磁盘阵列(raid) 重构策略 性能优化
下载PDF
廉价磁盘冗余阵列RAID的技术策略 被引量:6
10
作者 王宇 《哈尔滨商业大学学报(自然科学版)》 CAS 2002年第3期307-310,324,共5页
对廉价磁盘冗余阵列技术的分析 ,利用其可以提高存储设备速度和容错等能力 ,提出的不同情况下的决策方案 ,以提高网络服务器的性能。
关键词 廉价磁盘冗余阵列raid 容错 决策
下载PDF
RAID 4SMR:RAID Array with Shingled Magnetic Recording Disk for Mass Storage Systems 被引量:2
11
作者 Quoc Le Ahmed Amer JoAnne Holliday 《Journal of Computer Science & Technology》 SCIE EI CSCD 2019年第4期854-868,共15页
One way to increase storage density is using a shingled magnetic recording(SMR)disk.We propose a novel use of SMR disks with RAID(redundant array of independent disks)arrays,specifically building upon and compared wit... One way to increase storage density is using a shingled magnetic recording(SMR)disk.We propose a novel use of SMR disks with RAID(redundant array of independent disks)arrays,specifically building upon and compared with a basic RAID 4 arrangement.The proposed scheme(called RAID 4SMR)has the potential to improve the performance of a traditional RAID 4 array with SMR disks.Our evaluation shows that compared with the standard RAID 4,when using update in-place in RAID arrays,RAID 4SMR with garbage collection not just can allow the adoption of SMR disks with a reduced performance penalty,but offers a performance improvement of up to 56%. 展开更多
关键词 disk array redundant array of independent disks(raid) shingled magnetic recording(SMR) shingled WRITE
原文传递
一种用磁盘备份SSD的高性能可靠存储系统 被引量:11
12
作者 陈志广 肖侬 +1 位作者 刘芳 杜溢墨 《计算机研究与发展》 EI CSCD 北大核心 2013年第1期80-89,共10页
固态盘(solid state drive,SSD)因为其优越的性能已被大量部署于当前的存储系统中.但是,由于寿命有限,SSD的可靠性受到广泛的质疑.磁盘阵列(redundant arrays of inexpensive disk,RAID)是一种传统的用来提高可靠性的手段,但并不适用于S... 固态盘(solid state drive,SSD)因为其优越的性能已被大量部署于当前的存储系统中.但是,由于寿命有限,SSD的可靠性受到广泛的质疑.磁盘阵列(redundant arrays of inexpensive disk,RAID)是一种传统的用来提高可靠性的手段,但并不适用于SSD.这项工作提出一种基于SSD和磁盘的混合存储系统,构建该系统的主要思想是SSD响应所有I/O请求,从而获得较高的性能;磁盘备份所有数据,从而保证系统的可靠性.但是,磁盘的I/O性能显著低于SSD,构建该系统的问题在于磁盘能否及时地备份SSD上的数据.为了解决这一问题,从两方面提出优化:在延迟方面,采用非易失主存弥补磁盘与SSD的延迟差距;在带宽方面,采用两种措施:1)在单块磁盘内部重组I/O请求,使磁盘尽可能的顺序读写;2)采用多块磁盘备份多块SSD,通过将一块SSD上的写请求分散到多块磁盘上,有效应对单块SSD上出现的突发写请求.通过原型系统实现表明,该混合系统是可行的:磁盘能够为SSD提供实时的数据备份;与其他系统相比,该混合系统取得较高的性价比. 展开更多
关键词 闪存 固态盘 磁盘阵列 混合存储系统 可靠性
下载PDF
基于Ethernet多节点网络存储系统的研究 被引量:1
13
作者 刘晓光 王刚 +1 位作者 王颖 刘璟 《计算机工程与应用》 CSCD 北大核心 2002年第19期159-161,共3页
Internet的发展,要求一些计算机服务能够提供不间断的数据访问服务。传统的第二级存储设备的特点决定了它不适合于实现不间断数据访问。现有的解决方法如:SAN和NAS等,往往代价高昂。利用网络软RAID技术,基于Ethernet实现的网络存储器,... Internet的发展,要求一些计算机服务能够提供不间断的数据访问服务。传统的第二级存储设备的特点决定了它不适合于实现不间断数据访问。现有的解决方法如:SAN和NAS等,往往代价高昂。利用网络软RAID技术,基于Ethernet实现的网络存储器,具有第二级存储设备的性质和网络存储的优点,单位存储成本低,而且可以执行第三级存储器的数据备份功能,可以较好地满足对性能和价格的要求。 展开更多
关键词 ETHERNET 多节点网络存储系统 大容量存储 raid 存储网络 数据存储 计算机 存储器
下载PDF
磁盘阵列cache数据一致性的研究与实现 被引量:2
14
作者 冯丹 熊建刚 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2005年第10期70-72,共3页
为了实现磁盘阵列cache数据一致性,采用非易失存储设备NVRAM实现磁盘阵列cache,断电后保持数据不丢失.同时以写事务对cache进行修改,使cache写操作要么全部提交,要么完全撤销,保持cache数据一致性.为了撤销对cache的不完整修改,需要对ca... 为了实现磁盘阵列cache数据一致性,采用非易失存储设备NVRAM实现磁盘阵列cache,断电后保持数据不丢失.同时以写事务对cache进行修改,使cache写操作要么全部提交,要么完全撤销,保持cache数据一致性.为了撤销对cache的不完整修改,需要对cache进行备份,使cache能够还原到失败写操作执行之前的状态.若将数据写入cache的空闲块,那么仅需要对cache映射表进行备份;因为当撤销对cache的不完整修改时,将cache映射表的备份对cache映射表赋值,写入部分数据的空闲块还是被cache映射表记为空闲块,cache回到失败的写操作执行之前的状态.试验结果表明:在突然断电或死机情况下,都能确保cache数据的一致性. 展开更多
关键词 磁盘阵列 高速缓存 备份 事务机制
下载PDF
磁盘阵列多终端配置管理模块设计与实现 被引量:1
15
作者 谭志虎 万继光 贺黎 《计算机应用研究》 CSCD 北大核心 2008年第4期1268-1270,共3页
配置管理模块为用户提供多种灵活的配置方式,供用户对磁盘阵列的具体参数进行设置。单一的配置方式无法适应用户多样性需求。详细介绍了一种可同时支持多种终端配置的配置管理模块的功能、设计与实现。
关键词 磁盘阵列 配置终端 配置管理模块
下载PDF
图书馆随书光盘资源保存与应用研究 被引量:3
16
作者 刘昊 《科技情报开发与经济》 2011年第19期98-100,共3页
随书光盘的大量涌现,为图书馆带来了新的非书资源,但是也带来了新的管理难题。对目前随书光盘资源的保存手段进行深入分析与研究,剖析两种保存手段中客观存在的问题。针对两种保存手段的不足,提出交互式管理方式以解决问题。
关键词 随书光盘 光盘镜像 管理模式 磁盘阵列
下载PDF
IBM xSerier345 SCSI硬盘磁盘阵列的实现 被引量:1
17
作者 谢胡林 夏伟锋 《电脑知识与技术》 2007年第1期258-259,275,共3页
本文简要介绍了磁盘陈列技术原理和实践运用价值,并详细介绍如何在IBM xSerier345 SCSI硬盘上实现磁盘陈列的过程和方-击。说明利用RAID技术能提高磁盘存取速度、提高系统的客错能力。对那些网络管理员或系统维护员在存储设备的建设和... 本文简要介绍了磁盘陈列技术原理和实践运用价值,并详细介绍如何在IBM xSerier345 SCSI硬盘上实现磁盘陈列的过程和方-击。说明利用RAID技术能提高磁盘存取速度、提高系统的客错能力。对那些网络管理员或系统维护员在存储设备的建设和维护过程中有很好的实践参考价值。 展开更多
关键词 raid 磁盘陈列 存取速度 磁盘镜像
下载PDF
TSHOVER:A Novel Coding Scheme for Tolerating Triple Disk Failures in RAID/DRAID
18
作者 那宝玉 张毓森 +1 位作者 刘丽丽 刘鹏 《Tsinghua Science and Technology》 SCIE EI CAS 2007年第S1期39-44,共6页
This paper presents a novel method, called TSHOVER, for tolerating up to triple disk failures in RAID/DRAID architectures or others reliable storage systems. TSHOVER is two-dimensional code, which employs horizontal c... This paper presents a novel method, called TSHOVER, for tolerating up to triple disk failures in RAID/DRAID architectures or others reliable storage systems. TSHOVER is two-dimensional code, which employs horizontal code and vertical code at the same time with simple exclusive-OR (XOR) computations. This paper shows the new step ascending concepts used in encoding, and it has the capability of realizing fault tolerance. TSHOVER has better data recovery ability to those disk network storage systems with relatively more dynamic changes in the number of disks. Compared with RS and STAR code, TSHOVER has better encoding performance. When updating a data strip, only 6 XOR operations are needed. Both experimental results and theoretical analyses show that TSHOVER has better performance and higher efficiency than other algorithms. 展开更多
关键词 redundant array of independent disk (raid) Draid MDS codes fault tolerance
原文传递
Extending and analysis of X-Code
19
作者 金超 冯丹 刘景宁 《Journal of Shanghai University(English Edition)》 CAS 2011年第3期194-200,共7页
X-Code is one of the most important redundant array of independent disk (RAID)-6 codes which are capable of tolerating double disk failures. However, the code length of X-Code is restricted to be a prime number, and... X-Code is one of the most important redundant array of independent disk (RAID)-6 codes which are capable of tolerating double disk failures. However, the code length of X-Code is restricted to be a prime number, and such code length restriction of X-Code limits its usage in the real storage systems. Moreover, as a vertical RAID-6 code, X-Code can not be extended easily to an arbitrary code length like horizontal RAID-6 codes. In this paper, a novel and efficient code shortening algorithm for X-Code is proposed to extend X-Code to an arbitrary length. It can be further proved that the code shortening algorithm maintains the maximum-distance-separable (MDS) property of X-Code, and namely, the shortened X-Code is still MDS code with the optimal space efficiency. In the context of the shortening algorithm for X-Code, an in-depth performance analysis on X-Code at consecutive code lengths is conducted, and the impacts of the code shortening algorithm on the performance of X-Code in various performance metrics are revealed. 展开更多
关键词 redundant array of independent disk (raid)-6 X-Code vertical code code shortening performance analysis
下载PDF
如何提高计算机磁盘子系统的速度和可靠性
20
作者 薛健 于开年 《山东电子》 1996年第1期22-25,共4页
RAID是廉价冗余磁盘阵列的简称,它把多磁盘驱动器连接到一起协同工作,提供并行的数据传输和容错功能。本文将介绍RAID技术,探讨如何利用RAID技术提高磁盘子系统的速度和可靠性。
关键词 磁盘阵列 磁盘子系统 容错 可靠性 计算机
下载PDF